Theresa Haisch
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Theresa Haisch has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- Ulrike Krewer
Institute for Applied Materials – Electrochemical Technologies Karlsruhe Institute of Technology Adenauerring 20b 76137 Karlsruhe Germany
2 shared publications - Claudia Weidlich
Department of Chemical Technology DECHEMA‐Forschungsinstitut Theodor‐Heuss‐Allee 25 60486 Frankfurt am Main Germany
1 shared publication - De-Jun Chen
Environmental Metrology and Policy Program, Georgetown University, 37th & O Streets, NW, Washington, DC 20057, USA
1 shared publication Fabian Kubannek
Institute of Energy and Process Systems Engineering, TU Braunschweig, 38106 Braunschweig, Germany
1 shared publication- Fabian Kubannek
Institute of Energy and Process Systems Engineering (InES) Technische Universität Braunschweig Langer Kamp 19b 38106 Braunschweig Germany
1 shared publication - Hyunjoon Ji
DECHEMA Research Institute, Electrochemistry, Theodor-Heuss-Allee 25, 60486 Frankfurt am Main, Germany
1 shared publication
Latest Publications
- Open Access
Half-Cell State of Charge Monitoring for Determination of Crossover in VRFB—Considerations and Results Concerning Crossover Direction and Amount
Membranes play a crucial role in efficiency and longevity of flow batteries. Vanadium flow batteries suffer self-discharge and capacity fading due to crossover of electrolyte components through the membrane from one battery half-cell to the other. We consider the impact of vanadium species crossing ion exchange membranes on state of charge of the battery and we present a simple method to determine crossoverll open circuit potential measurements. State of s. State of charge for the negative and positive half-cell is simulated based on assumptions and simplifications for cation and anion exchange membranes and different crossover parameters. We introduce a crossover index “Ind” which enables the determination of crossover direction from state of charge data for the negative and positive half-cell and therewith identification of the half-cell in which predominant self-discharge occurs. Furthermore Ind allows statements on crossover amount in dependence on state of operation. Simulated case studies are compared to experimental state of charge values estimated from half-cell potential measurements. Our results reveal that half-cell potential monitoring respectively half-cell SOC estimation, is a simple and suitable tool for the identification of crossover direction and relative amount of crossover in VFB.Open AccessHalf-Cell State of Charge Monitoring for Determination of Crossover in VRFB—Considerations and Results Concerning Crossover Direction and Amount
Membranes play a crucial role in efficiency and longevity of flow batteries. Vanadium flow batteries suffer self-discharge and capacity fading due to crossover of electrolyte components through the membrane from one battery half-cell to the other. We consider the impact of vanadium species crossing ion exchange membranes on state of charge of the battery and we present a simple method to determine crossoverll open circuit potential measurements. State of s. State of charge for the negative and positive half-cell is simulated based on assumptions and simplifications for cation and anion exchange membranes and different crossover parameters. We introduce a crossover index “Ind” which enables the determination of crossover direction from state of charge data for the negative and positive half-cell and therewith identification of the half-cell in which predominant self-discharge occurs. Furthermore Ind allows statements on crossover amount in dependence on state of operation. Simulated case studies are compared to experimental state of charge values estimated from half-cell potential measurements. Our results reveal that half-cell potential monitoring respectively half-cell SOC estimation, is a simple and suitable tool for the identification of crossover direction and relative amount of crossover in VFB. - 4 September 2020
- Published by American Chemical Society (ACS) in ACS Applied Materials & Interfaces
- Vol. 12 (39) , 43535-43542
Origin of the Drastic Current Decay during Potentiostatic Alkaline Methanol Oxidation
The current production from the alkaline methanol electrooxidation reaction does not reach a steady-state on a smooth platinum catalyst under potentiostatic conditions. We investigated two possible explanations for this phenomenon: changes on the catalyst surface and changes in the solution near the electrode. In situ Fourier transform infrared spectroscopy experiments were conducted to evaluate the catalyst surface and a simulation model was set up to describe changes of concentrations inside the solution. Linear- and bridge-bonded carbon monoxide are the only organic compounds which can be detected by in situ spectroscopy at fixed potentials but their amount do not increase over time. The simulation shows that the consumption of hydroxide ions and production of carbonaceous species during alkaline oxidation causes a local pH-shift near the catalyst surface. Assuming a one-electron transfer as the limiting step, this pH-shift was found accountable for the observed current loss at a potential of 0.7 V.
- 4 September 2020
- Published by American Chemical Society (ACS) in ACS Applied Materials & Interfaces
- Vol. 12 (39) , 43535-43542
Origin of the Drastic Current Decay during Potentiostatic Alkaline Methanol Oxidation
The current production from the alkaline methanol electrooxidation reaction does not reach a steady-state on a smooth platinum catalyst under potentiostatic conditions. We investigated two possible explanations for this phenomenon: changes on the catalyst surface and changes in the solution near the electrode. In situ Fourier transform infrared spectroscopy experiments were conducted to evaluate the catalyst surface and a simulation model was set up to describe changes of concentrations inside the solution. Linear- and bridge-bonded carbon monoxide are the only organic compounds which can be detected by in situ spectroscopy at fixed potentials but their amount do not increase over time. The simulation shows that the consumption of hydroxide ions and production of carbonaceous species during alkaline oxidation causes a local pH-shift near the catalyst surface. Assuming a one-electron transfer as the limiting step, this pH-shift was found accountable for the observed current loss at a potential of 0.7 V.
- 1 July 2020
- Published by Royal Society of Chemistry (RSC) in Physical Chemistry Chemical Physics
- Vol. 22 (29) , 16648-16654
The origin of the hysteresis in cyclic voltammetric response of alkaline methanol electrooxidation
The origin of the hysteresis is investigated by electrochemical measurements,in situIR spectroscopy and simulations. It is concluded that the formation of platinum oxides rather than the formation of blocking intermediates causes the hysteresis.
- 1 July 2020
- Published by Royal Society of Chemistry (RSC) in Physical Chemistry Chemical Physics
- Vol. 22 (29) , 16648-16654
The origin of the hysteresis in cyclic voltammetric response of alkaline methanol electrooxidation
The origin of the hysteresis is investigated by electrochemical measurements,in situIR spectroscopy and simulations. It is concluded that the formation of platinum oxides rather than the formation of blocking intermediates causes the hysteresis.