Faiz Husnayain
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Faiz Husnayain has a total of 97 co-authors. Here are the top co-authors by number of shared publications:
Amien Rahardjo
Universitas Indonesia
13 shared publications- Fauzan Hanif Jufri
Universitas Indonesia
9 shared publications Dwi Riana Aryani
Departemen Teknik Elektro, Fakultas Teknik, Universitas Indonesia, Indonesia
3 shared publications- Feri Yusivar
Universitas Indonesia
3 shared publications A Rahardjo
Lecturer, Department of Electrical Engineering Universitas Indonesia, Depok, Indonesia
2 shared publicationsA Setiawan
Engineer, Operation System Department PT. PLN (Persero) P2B, Depok, Indonesia
2 shared publications
Latest Publications
- Open Access
- 23 October 2026
- Published by Tanjungpura University in ELKHA
- p. 105-112
Comparison of Volt–VAR Control and Power Factor Control of PV Inverters on the Voltage Profile of Low Voltage Distribution Networks
The rapid increase of photovoltaic generation in low-voltage distribution networks can trigger voltage rise and overvoltage, particularly on feeders with a high resistance-to-reactance ratio. This study compares two smart-inverter voltage regulation strategies—volt–var control and power-factor control—to mitigate overvoltage and to increase the voltage-constrained photovoltaic penetration limit. A detailed low-voltage feeder model was developed, and steady-state power-flow simulations were performed in PowerFactory under two operating scenarios representing overvoltage and undervoltage conditions. Performance was evaluated using maximum bus voltage and network power losses while the photovoltaic penetration level was increased gradually. Without inverter control, the voltage limit was exceeded at a higher penetration level, limiting acceptable penetration to 125%. With volt–var control, reactive power is exchanged only when the local voltage deviates from a normal-voltage band, so overvoltage is mitigated effectively with a smaller increase in losses, extending the acceptable penetration to 140%. Power-factor control provides stronger voltage reduction because many inverters respond simultaneously following active power output, enabling the highest acceptable penetration of 150%, but it tends to drive larger reactive power flow and higher losses. Overall, both strategies improve voltage compliance and hosting capacity, but the trade-off between voltage reduction and increased losses indicates that the preferred method should be selected based on feeder operating conditions and the utility objective.
- 23 October 2026
- Published by Tanjungpura University in ELKHA
- p. 105-112
Open AccessComparison of Volt–VAR Control and Power Factor Control of PV Inverters on the Voltage Profile of Low Voltage Distribution Networks
The rapid increase of photovoltaic generation in low-voltage distribution networks can trigger voltage rise and overvoltage, particularly on feeders with a high resistance-to-reactance ratio. This study compares two smart-inverter voltage regulation strategies—volt–var control and power-factor control—to mitigate overvoltage and to increase the voltage-constrained photovoltaic penetration limit. A detailed low-voltage feeder model was developed, and steady-state power-flow simulations were performed in PowerFactory under two operating scenarios representing overvoltage and undervoltage conditions. Performance was evaluated using maximum bus voltage and network power losses while the photovoltaic penetration level was increased gradually. Without inverter control, the voltage limit was exceeded at a higher penetration level, limiting acceptable penetration to 125%. With volt–var control, reactive power is exchanged only when the local voltage deviates from a normal-voltage band, so overvoltage is mitigated effectively with a smaller increase in losses, extending the acceptable penetration to 140%. Power-factor control provides stronger voltage reduction because many inverters respond simultaneously following active power output, enabling the highest acceptable penetration of 150%, but it tends to drive larger reactive power flow and higher losses. Overall, both strategies improve voltage compliance and hosting capacity, but the trade-off between voltage reduction and increased losses indicates that the preferred method should be selected based on feeder operating conditions and the utility objective.
- Open Access
- 12 August 2026
- Published by MDPI AG in Technologies
- Vol. 14 (8) , 503
A Multi-Physics Continuous Integral State-Space Model for Battery Health Prognosis Under Dynamic Tropical Environments
Tracking capacity fade and predicting the lifespan of Lithium Iron Phosphate (LiFePO4) batteries under calendar aging are crucial for the reliability of Battery Energy Storage Systems (BESSs) in tropical regions. Conventional empirical models often rely on static environmental averages and neglect coupled thermal–hygroscopic dynamics. To address these limitations, this paper introduces a multi-physics coupled state-space-based continuous integral model for battery degradation under dynamic tropical boundary conditions. The primary novelty of this research lies in the development of a continuous-time multi-physics state-space degradation model that explicitly captures the interconnected interactions between temperature, humidity, and State of Charge (SoC) under dynamically varying tropical microclimates. Calendar aging tests were conducted for 180 days inside an environmental test chamber under tropical microclimate conditions (average of 29.91 °C, RH of 77.26%), with reference performance tests executed at a low C-rate of C/20 to extract static electrochemical capacity. Parameter identification using an Ordinary Least Squares (OLS) solver demonstrates high model fitting, with R-squared values ranging from 0.8229 to 0.9429. Extrapolation results provide realistic end-of-life projections between 8.9 and 59.8 years and successfully identify the critical physical transition points P1 and P2 at the Solid Electrolyte Interphase (SEI) layer. Overall, this research provides a prognostic instrument for optimizing the operational management of utility-scale BESS in tropical climates.
- 12 August 2026
- Published by MDPI AG in Technologies
- Vol. 14 (8) , 503
Open AccessA Multi-Physics Continuous Integral State-Space Model for Battery Health Prognosis Under Dynamic Tropical Environments
Tracking capacity fade and predicting the lifespan of Lithium Iron Phosphate (LiFePO4) batteries under calendar aging are crucial for the reliability of Battery Energy Storage Systems (BESSs) in tropical regions. Conventional empirical models often rely on static environmental averages and neglect coupled thermal–hygroscopic dynamics. To address these limitations, this paper introduces a multi-physics coupled state-space-based continuous integral model for battery degradation under dynamic tropical boundary conditions. The primary novelty of this research lies in the development of a continuous-time multi-physics state-space degradation model that explicitly captures the interconnected interactions between temperature, humidity, and State of Charge (SoC) under dynamically varying tropical microclimates. Calendar aging tests were conducted for 180 days inside an environmental test chamber under tropical microclimate conditions (average of 29.91 °C, RH of 77.26%), with reference performance tests executed at a low C-rate of C/20 to extract static electrochemical capacity. Parameter identification using an Ordinary Least Squares (OLS) solver demonstrates high model fitting, with R-squared values ranging from 0.8229 to 0.9429. Extrapolation results provide realistic end-of-life projections between 8.9 and 59.8 years and successfully identify the critical physical transition points P1 and P2 at the Solid Electrolyte Interphase (SEI) layer. Overall, this research provides a prognostic instrument for optimizing the operational management of utility-scale BESS in tropical climates.
- Open Access
- 10 August 2026
- Published by Politeknik Sci in Journal of Business, Social and Technology
- Vol. 7 (4) , 1951-1959
Integrated SCADA Framework for Acid Deposition Monitoring with Occupational Safety Management
Background: Acid deposition is a transboundary environmental problem that demands a reliable and safe measurement system. Previous studies on the same chamber progressed from manual measurement to real-time IoT monitoring; however, they still lacked centralized supervision, automated safety mechanisms, and early detection of sensor faults. Objective: This study aimed to develop and evaluate an integrated supervisory system that combines Occupational Health and Safety (OHS) management with condition-based maintenance for acid deposition monitoring. Methods: The system was designed using a Software-in-the-Loop (SiL) architecture within the Siemens ecosystem, following the ISA-95 framework, and was subsequently evaluated through fault-injection scenarios. Results: The system monitored pH, temperature, water level, and actuator status at 1-second intervals without communication failures or data loss. The safety module detected all three tested hazardous pH conditions below 5.6, resulting in a Probability of Detection (POD) of 100%. The maintenance module detected out-of-range values and triggered an emergency shutdown after three faults occurred within 60 seconds. Availability varied from 66% to 93%, depending on failure frequency and repair time, indicating that faster recovery and fewer repeated failures improved system reliability. Conclusion: The findings indicate that integrating supervision, OHS management, and condition-based maintenance can strengthen the safety, traceability, and reliability of acid deposition monitoring. The main novelty lies in integrating these functions within a single SCADA architecture validated through Software-in-the-Loop simulation, providing a practical basis for safer environmental monitoring stations and subsequent field implementation.
- 10 August 2026
- Published by Politeknik Sci in Journal of Business, Social and Technology
- Vol. 7 (4) , 1951-1959
Open AccessIntegrated SCADA Framework for Acid Deposition Monitoring with Occupational Safety Management
Background: Acid deposition is a transboundary environmental problem that demands a reliable and safe measurement system. Previous studies on the same chamber progressed from manual measurement to real-time IoT monitoring; however, they still lacked centralized supervision, automated safety mechanisms, and early detection of sensor faults. Objective: This study aimed to develop and evaluate an integrated supervisory system that combines Occupational Health and Safety (OHS) management with condition-based maintenance for acid deposition monitoring. Methods: The system was designed using a Software-in-the-Loop (SiL) architecture within the Siemens ecosystem, following the ISA-95 framework, and was subsequently evaluated through fault-injection scenarios. Results: The system monitored pH, temperature, water level, and actuator status at 1-second intervals without communication failures or data loss. The safety module detected all three tested hazardous pH conditions below 5.6, resulting in a Probability of Detection (POD) of 100%. The maintenance module detected out-of-range values and triggered an emergency shutdown after three faults occurred within 60 seconds. Availability varied from 66% to 93%, depending on failure frequency and repair time, indicating that faster recovery and fewer repeated failures improved system reliability. Conclusion: The findings indicate that integrating supervision, OHS management, and condition-based maintenance can strengthen the safety, traceability, and reliability of acid deposition monitoring. The main novelty lies in integrating these functions within a single SCADA architecture validated through Software-in-the-Loop simulation, providing a practical basis for safer environmental monitoring stations and subsequent field implementation.
- 2 July 2026
- Published by Springer Nature
- p. 245-265
Speed Control of PMSM Using Diode-Clamped Multilevel Inverter with Single-Neuron PI Controller
- 2 July 2026
- Published by Springer Nature
- p. 245-265
Speed Control of PMSM Using Diode-Clamped Multilevel Inverter with Single-Neuron PI Controller
- Open Access
- 15 June 2026
- Published by Politeknik Sci in Journal of Business, Social and Technology
- Vol. 7 (3) , 1333-1349
Maintenance Cost Optimization Model for Rooftop PV Based on a Seasonal Soiling Model and Economic Cleaning Threshold to Improve the Performance Ratio
Background: The Performance Ratio (PR) of photovoltaic (PV) systems in tropical monsoon regions decreases due to soiling accumulation on module surfaces, yet techno-economically optimal cleaning strategies remain unavailable specifically for the Indonesian context. Objective: This study aims to evaluate the investment feasibility of a 400 kWp rooftop PV system in the Cikarang industrial estate, determine the optimal cleaning strategy, and quantify the system's contribution to carbon emission reduction. Methods: The research employs a quantitative approach based on 1,503 days of operational data (2022–2025), using an integrated framework combining a Seasonal Soiling Model (SSM) with rain-reset parameters, an Economic Cleaning Threshold (ECT) with three lookback versions, two-layer risk analysis (OAT and Monte Carlo simulation, 10,000 iterations), and carbon emission analysis. Results: The investment is feasible with NPV of IDR 2.48 billion, IRR of 16.73%, payback of 9 years, and LCOE of IDR 828.77/kWh (25.7% below PLN tariff), with 100% probability of positive NPV. The optimal strategy is annual cleaning in August (S1), yielding NPV IDR 99.2 million higher than existing practice. The system reduces 9,258 tons CO₂ over 25 years with negative abatement cost of USD −21.21/ton CO₂. Conclusion: The integrated TEA-ECT framework advances rooftop PV asset management by demonstrating that value-based, seasonally adaptive cleaning optimization simultaneously enhances economic returns and environmental performance, providing a replicable methodology for tropical monsoon regions.
- 15 June 2026
- Published by Politeknik Sci in Journal of Business, Social and Technology
- Vol. 7 (3) , 1333-1349
Open AccessMaintenance Cost Optimization Model for Rooftop PV Based on a Seasonal Soiling Model and Economic Cleaning Threshold to Improve the Performance Ratio
Background: The Performance Ratio (PR) of photovoltaic (PV) systems in tropical monsoon regions decreases due to soiling accumulation on module surfaces, yet techno-economically optimal cleaning strategies remain unavailable specifically for the Indonesian context. Objective: This study aims to evaluate the investment feasibility of a 400 kWp rooftop PV system in the Cikarang industrial estate, determine the optimal cleaning strategy, and quantify the system's contribution to carbon emission reduction. Methods: The research employs a quantitative approach based on 1,503 days of operational data (2022–2025), using an integrated framework combining a Seasonal Soiling Model (SSM) with rain-reset parameters, an Economic Cleaning Threshold (ECT) with three lookback versions, two-layer risk analysis (OAT and Monte Carlo simulation, 10,000 iterations), and carbon emission analysis. Results: The investment is feasible with NPV of IDR 2.48 billion, IRR of 16.73%, payback of 9 years, and LCOE of IDR 828.77/kWh (25.7% below PLN tariff), with 100% probability of positive NPV. The optimal strategy is annual cleaning in August (S1), yielding NPV IDR 99.2 million higher than existing practice. The system reduces 9,258 tons CO₂ over 25 years with negative abatement cost of USD −21.21/ton CO₂. Conclusion: The integrated TEA-ECT framework advances rooftop PV asset management by demonstrating that value-based, seasonally adaptive cleaning optimization simultaneously enhances economic returns and environmental performance, providing a replicable methodology for tropical monsoon regions.
- Open Access
- 15 June 2026
- Published by Politeknik Sci in Journal of Business, Social and Technology
- Vol. 7 (3) , 1270-1282
A Transparent BESS Sizing Framework for Ramp-Rate Control of a 100 MW Solar PV Plant Using SoDa Synthetic Power Profiles
Background: The integration of utility-scale solar photovoltaic power plants requires attention to short-term power fluctuations because photovoltaic output can change rapidly due to variations in irradiance, temperature, atmospheric conditions, and cloud movement. Objective: This study aims to evaluate a SoDa-based synthetic photovoltaic power profile and optimize Battery Energy Storage System capacity for ramp-rate control of a 100 MW solar photovoltaic power plant. Methods: A quantitative simulation and optimization approach was applied. A one-minute synthetic photovoltaic power profile was generated using SoDa, evaluated for monthly consistency against NASA POWER, and analyzed under multiple ramp-rate limit scenarios. The optimum BESS power and energy capacities were determined using deterministic grid search and benchmarked against Particle Swarm Optimization (PSO). Results: The synthetic profile demonstrated adequate monthly consistency with NASA POWER (Pearson r = 0.860, rRMSE = 5.99%), confirming its suitability for pre-feasibility ramp-rate analysis. Stricter ramp-rate limits produced markedly more violations and required higher BESS capacities, ranging from 10 MW/10 MWh for moderate limits up to 20.5 MW/20.5 MWh for the most stringent scenario, with 100% compliance achieved in all cases. This framework demonstrates the practical value of synthetic data-driven BESS sizing for early-stage solar project planning in data-scarce environments. Conclusion: Stricter ramp-rate limits increase BESS capacity requirements once the minimum capacity constraint is no longer sufficient. This study contributes an auditable, transparent pre-feasibility framework that integrates synthetic data generation, and advancing the literature on data-driven energy storage sizing for utility-scale solar PV projects.
- 15 June 2026
- Published by Politeknik Sci in Journal of Business, Social and Technology
- Vol. 7 (3) , 1270-1282
Open AccessA Transparent BESS Sizing Framework for Ramp-Rate Control of a 100 MW Solar PV Plant Using SoDa Synthetic Power Profiles
Background: The integration of utility-scale solar photovoltaic power plants requires attention to short-term power fluctuations because photovoltaic output can change rapidly due to variations in irradiance, temperature, atmospheric conditions, and cloud movement. Objective: This study aims to evaluate a SoDa-based synthetic photovoltaic power profile and optimize Battery Energy Storage System capacity for ramp-rate control of a 100 MW solar photovoltaic power plant. Methods: A quantitative simulation and optimization approach was applied. A one-minute synthetic photovoltaic power profile was generated using SoDa, evaluated for monthly consistency against NASA POWER, and analyzed under multiple ramp-rate limit scenarios. The optimum BESS power and energy capacities were determined using deterministic grid search and benchmarked against Particle Swarm Optimization (PSO). Results: The synthetic profile demonstrated adequate monthly consistency with NASA POWER (Pearson r = 0.860, rRMSE = 5.99%), confirming its suitability for pre-feasibility ramp-rate analysis. Stricter ramp-rate limits produced markedly more violations and required higher BESS capacities, ranging from 10 MW/10 MWh for moderate limits up to 20.5 MW/20.5 MWh for the most stringent scenario, with 100% compliance achieved in all cases. This framework demonstrates the practical value of synthetic data-driven BESS sizing for early-stage solar project planning in data-scarce environments. Conclusion: Stricter ramp-rate limits increase BESS capacity requirements once the minimum capacity constraint is no longer sufficient. This study contributes an auditable, transparent pre-feasibility framework that integrates synthetic data generation, and advancing the literature on data-driven energy storage sizing for utility-scale solar PV projects.
- Open Access
- 12 May 2026
- Published by MDPI AG in Technologies
- Vol. 14 (5) , 298
Low-Cost Active Cell Balancing Battery Management System for Electric Vehicles with Cell Charger as Cell Balancer
Cell imbalance in battery packs can cause premature termination during battery discharge and recharge processes. This condition can decrease the usable energy of the battery. The cost of batteries can reach 30–40% of the price of an electric vehicle, so battery cell balancing in a battery management system (BMS) and a battery thermal management system (BTMS) is very important to maximize battery capacity, safety, and life. In conventional active balancing studies, the cell-balancing process draws energy from the cells or battery pack, resulting in a reduction in battery pack energy due to power losses during the balancing process. This condition can reduce the range of electric vehicles. In this paper, a battery balancing system with a reduced number of switches and low cost, as well as the use of a cell charger, is proposed. The cell charger will draw energy from the electrical grid so that it can maximize the energy in the battery pack. A balancing current of 3 A from the cell charger is used in the balancing process. A 23S1P 100 Ah LiFePO4 battery pack, consisting of 23 cells, is used for validation. Test results show that the proposed battery balancing system can balance the voltage of 23 battery cells for 40 minutes from the highest and lowest voltage difference of 116.7 mV to 11.8 mV.
- 12 May 2026
- Published by MDPI AG in Technologies
- Vol. 14 (5) , 298
Open AccessLow-Cost Active Cell Balancing Battery Management System for Electric Vehicles with Cell Charger as Cell Balancer
Cell imbalance in battery packs can cause premature termination during battery discharge and recharge processes. This condition can decrease the usable energy of the battery. The cost of batteries can reach 30–40% of the price of an electric vehicle, so battery cell balancing in a battery management system (BMS) and a battery thermal management system (BTMS) is very important to maximize battery capacity, safety, and life. In conventional active balancing studies, the cell-balancing process draws energy from the cells or battery pack, resulting in a reduction in battery pack energy due to power losses during the balancing process. This condition can reduce the range of electric vehicles. In this paper, a battery balancing system with a reduced number of switches and low cost, as well as the use of a cell charger, is proposed. The cell charger will draw energy from the electrical grid so that it can maximize the energy in the battery pack. A balancing current of 3 A from the cell charger is used in the balancing process. A 23S1P 100 Ah LiFePO4 battery pack, consisting of 23 cells, is used for validation. Test results show that the proposed battery balancing system can balance the voltage of 23 battery cells for 40 minutes from the highest and lowest voltage difference of 116.7 mV to 11.8 mV.
- Open Access
- 20 October 2025
- Published by Tanjungpura University in ELKHA
- Vol. 17 (2) , 101-108
Optimal Hybrid Renewable Energy Integration for Reliable and Cost Efficient of Isolated System
Nusmapi Island is one of Indonesia's isolated islands that rely on Diesel Power Plant (PLTD) with a capacity of 20 kW to meet the electricity needs of its 50 customers. However, this PLTD only operates 12 hours a day due to high operational costs, reaching IDR 215,240,980/year with fuel consumption of 20,889 liters of diesel, equivalent to 17.56 tons with a COE of IDR 7,132/kWh in 2023. The reliance on diesel generators exacerbates ecological harm by releasing COâ‚‚ emissions"”a critical contradiction to Indonesia"™s nationally determined contribution (NDC) under the Paris Agreement, which mandates carbon neutrality by 2060. This research seeks to determine the most effective hybrid energy system design and configuration for Nusmapi Island, evaluating both technical feasibility and economic viability. The technical feasibility was assessed based on the unmet electric load, while the economic feasibility was evaluated using operational costs and the Cost of Energy (COE). The analysis indicates that the optimal system configuration comprises a 8,1-kW solar photovoltaic array, a 20-kW diesel generator, a 12-kW inverter, and five battery units housed within a single compartment. This configuration in real implementation will be able to produce 61,193 kWh/year, thereby increasing the power hours to 24 hours and reducing the unmet electric load to 0%. It will have a COE of IDR 3,280/kWh and will result in a fuel consumption reduction of 3,661 liters/year and operational costs of IDR 30,692,119/year. In addition, this configuration has environmental advantages with a renewable fraction reaching 18.3%
- 20 October 2025
- Published by Tanjungpura University in ELKHA
- Vol. 17 (2) , 101-108
Open AccessOptimal Hybrid Renewable Energy Integration for Reliable and Cost Efficient of Isolated System
Nusmapi Island is one of Indonesia's isolated islands that rely on Diesel Power Plant (PLTD) with a capacity of 20 kW to meet the electricity needs of its 50 customers. However, this PLTD only operates 12 hours a day due to high operational costs, reaching IDR 215,240,980/year with fuel consumption of 20,889 liters of diesel, equivalent to 17.56 tons with a COE of IDR 7,132/kWh in 2023. The reliance on diesel generators exacerbates ecological harm by releasing COâ‚‚ emissions"”a critical contradiction to Indonesia"™s nationally determined contribution (NDC) under the Paris Agreement, which mandates carbon neutrality by 2060. This research seeks to determine the most effective hybrid energy system design and configuration for Nusmapi Island, evaluating both technical feasibility and economic viability. The technical feasibility was assessed based on the unmet electric load, while the economic feasibility was evaluated using operational costs and the Cost of Energy (COE). The analysis indicates that the optimal system configuration comprises a 8,1-kW solar photovoltaic array, a 20-kW diesel generator, a 12-kW inverter, and five battery units housed within a single compartment. This configuration in real implementation will be able to produce 61,193 kWh/year, thereby increasing the power hours to 24 hours and reducing the unmet electric load to 0%. It will have a COE of IDR 3,280/kWh and will result in a fuel consumption reduction of 3,661 liters/year and operational costs of IDR 30,692,119/year. In addition, this configuration has environmental advantages with a renewable fraction reaching 18.3%
- Open Access
- 30 September 2025
- Published by Electrical Engineering Department, Faculty of Engineering, Universitas Indonesia in International Journal of Electrical, Computer, and Biomedical Engineering
- Vol. 3 (3) , 486–506
Analysis of Single Phase to Ground Faults Caused by Animals on Energy Not Served (ENS) in the Sumatera System
Animal disturbances on the High Voltage / Extra High Transmission Air Lines (SUTT / SUTET) in the work area of PT PLN (Persero) Sumatra Load Regulation and Distribution Center Main Unit (UIP3B Sumatra) during the period 2020-2024 have caused 208 animal disturbances on transmission lines and 35 animal disturbances on power transformers. This study provides information on mitigating animal interference, analyzing trends or patterns of animal habits that cause interference, and providing information on Energy Not Served (ENS). The data covers the period from 2020 to 2024, with a focus on evaluating the types of animals causing interference, the frequency and duration of outages, load data at the time of interference and the effectiveness of mitigation implemented, including recording the date, location, animal species, event classification, causal factors and response actions taken. This approach aims to improve understanding of the impact and behavior of wildlife on energy supply and to improve reliability and reduce the number of ENS. The results showed that the behavior of each animal was consistent with the fault data analysis, and the largest amount of undelivered power was monkeys 629.15 MWh, followed by birds 391.167 MWh and 358.04 MWh. Reducing the number of disturbances is done by preventive maintenance in animal-prone areas, with regular monitoring and evaluation so that ENS can be minimized
- 30 September 2025
- Published by Electrical Engineering Department, Faculty of Engineering, Universitas Indonesia in International Journal of Electrical, Computer, and Biomedical Engineering
- Vol. 3 (3) , 486–506
Open AccessAnalysis of Single Phase to Ground Faults Caused by Animals on Energy Not Served (ENS) in the Sumatera System
Animal disturbances on the High Voltage / Extra High Transmission Air Lines (SUTT / SUTET) in the work area of PT PLN (Persero) Sumatra Load Regulation and Distribution Center Main Unit (UIP3B Sumatra) during the period 2020-2024 have caused 208 animal disturbances on transmission lines and 35 animal disturbances on power transformers. This study provides information on mitigating animal interference, analyzing trends or patterns of animal habits that cause interference, and providing information on Energy Not Served (ENS). The data covers the period from 2020 to 2024, with a focus on evaluating the types of animals causing interference, the frequency and duration of outages, load data at the time of interference and the effectiveness of mitigation implemented, including recording the date, location, animal species, event classification, causal factors and response actions taken. This approach aims to improve understanding of the impact and behavior of wildlife on energy supply and to improve reliability and reduce the number of ENS. The results showed that the behavior of each animal was consistent with the fault data analysis, and the largest amount of undelivered power was monkeys 629.15 MWh, followed by birds 391.167 MWh and 358.04 MWh. Reducing the number of disturbances is done by preventive maintenance in animal-prone areas, with regular monitoring and evaluation so that ENS can be minimized
- Open Access
- 30 September 2025
- Published by Electrical Engineering Department, Faculty of Engineering, Universitas Indonesia in International Journal of Electrical, Computer, and Biomedical Engineering
- Vol. 3 (3) , 507–518
Grid Impact of Battery Swapping Station for Electric Two-Wheelers in Indonesia
Indonesia is rapidly advancing toward electric transportation, with electric two-wheelers playing a crucial role, driven by widespread use and cost-effectiveness. While battery swapping stations (BSS) offer a practical and gap solution over charging station scenario through the stop-go schema, knockdown units and lessen upfront investment, however their unpredictable nature—stemming from random user swaps and varying battery state-of-charge (SoC)—creates dependency operational challenges, particularly for low-voltage distribution grid feeders (DGF). Hence, this article thoroughly evaluates grid impacts using a modified IEEE 9-bus system, focusing on future urban multi-source feeders in Indonesia. A stochastic simulation process for BSS operates every minute over 1440 periods, effectively capturing the near-realistic dynamics of BSS operational behavior and assessing the effects on voltage stability, lines, and transformer loadings concerning BSS integration in quasi-dynamic power flow analysis through DIgSILENT PowerFactory. The findings reveal that even a minor deployment of BSS can cause a voltage drop of up to 1.1%, a 30% increase in transformer loading, and a 100% rise in line loading, especially during peak exchangeable periods. These results highlight the need for proactive infrastructure planning and grid readiness strategies toward Indonesia’s future vision to decarbonize the transport sector into a scalable electric vehicle (EV) ecosystem.
- 30 September 2025
- Published by Electrical Engineering Department, Faculty of Engineering, Universitas Indonesia in International Journal of Electrical, Computer, and Biomedical Engineering
- Vol. 3 (3) , 507–518
Open AccessGrid Impact of Battery Swapping Station for Electric Two-Wheelers in Indonesia
Indonesia is rapidly advancing toward electric transportation, with electric two-wheelers playing a crucial role, driven by widespread use and cost-effectiveness. While battery swapping stations (BSS) offer a practical and gap solution over charging station scenario through the stop-go schema, knockdown units and lessen upfront investment, however their unpredictable nature—stemming from random user swaps and varying battery state-of-charge (SoC)—creates dependency operational challenges, particularly for low-voltage distribution grid feeders (DGF). Hence, this article thoroughly evaluates grid impacts using a modified IEEE 9-bus system, focusing on future urban multi-source feeders in Indonesia. A stochastic simulation process for BSS operates every minute over 1440 periods, effectively capturing the near-realistic dynamics of BSS operational behavior and assessing the effects on voltage stability, lines, and transformer loadings concerning BSS integration in quasi-dynamic power flow analysis through DIgSILENT PowerFactory. The findings reveal that even a minor deployment of BSS can cause a voltage drop of up to 1.1%, a 30% increase in transformer loading, and a 100% rise in line loading, especially during peak exchangeable periods. These results highlight the need for proactive infrastructure planning and grid readiness strategies toward Indonesia’s future vision to decarbonize the transport sector into a scalable electric vehicle (EV) ecosystem.