Huayan Xu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Huayan Xu has a total of 164 co-authors. Here are the top co-authors by number of shared publications:
- Ying-Kun Guo
Department of Radiology, Key Laboratory of Obstetric & Gynecologic and Pediatric Diseases and Birth Defects of Ministry of Education, West China Second University Hospital, Sichuan University, Chengdu, China
22 shared publications - Zhi-Gang Yang
Department of Radiology, West China Hospital, Sichuan University, Chengdu, China
14 shared publications - Rong Xu
Department of Radiology, Key Laboratory of Birth Defects and Related Diseases of Women and Children of Ministry of Education, West China Second University Hospital, Sichuan University, Chengdu, China
6 shared publications - Zhenlin Li
Department of Radiology, West China Hospital of Sichuan University, Chengdu, China
6 shared publications - Ke Shi
Department of Radiology, West China Hospital, Sichuan University, Chengdu, China
5 shared publications Ke Xu
Department of Radiology, Medical Imaging Center, West China Second Hospital of Sichuan University
5 shared publications
Latest Publications
- Open Access
- 2 July 2026
- Published by Frontiers Media SA in Frontiers in Medicine
- Vol. 13
Construction of a virtual simulation teaching system for medical imaging education: a single-center experience
Virtual simulation constitutes a multidisciplinary field that integrates computer graphics, dynamic simulation modeling, human–computer interaction, and artificial intelligence. It has evolved from an auxiliary tool into a core teaching methodology, becoming indispensable to modern medical education. Through the establishment of a high-fidelity digital ecosystem, this technology achieves the accurate reproduction of real clinical scenarios. It provides a reliable support platform for evidence-based teaching and practical clinical competency training. Medical imaging education is a critical component of clinical training, and the integration of virtual simulation technology has emerged as a key strategic approach to optimizing clinical teaching outcomes, bridging the gap between theoretical knowledge and clinical practice. Furthermore, medical imaging education aims to cultivate competent clinical imaging professionals with comprehensive practical capabilities. This descriptive single-center study focuses on the development, implementation, and evaluation of a specialty-oriented virtual simulation teaching system for medical imaging technology. The effectiveness of the system was evaluated by comparing pre- and post-training outcomes among participants with three different levels of technical experience. The key components of an effective virtual simulation teaching system include clear identification of user needs, selection of appropriate technological approaches, sufficient granularity in system design, and implementation of engaging interaction modalities. For the training assessment of the magnetic resonance imaging (MRI) section, the comprehensive skills related to fetal scanning improved in all subjects (54.19 ± 18.03 vs. 66.62 ± 12.41, p < 0.001) after virtual simulation training. Among technicians with different experiences, residents (42.38 ± 15.41 vs. 59.95 ± 12.63) and junior technicians (63.4 ± 12.13 vs. 73.07 ± 8.34, all p < 0.05) showed the most significant improvement after retraining. In contrast, the improvement among senior technicians (72.50 ± 7.89 vs. 73.83 ± 7.41, p = 0.117) was not significant. These findings suggest the potential application of virtual simulation in fetal prenatal screening training.
- 2 July 2026
- Published by Frontiers Media SA in Frontiers in Medicine
- Vol. 13
Open AccessConstruction of a virtual simulation teaching system for medical imaging education: a single-center experience
Virtual simulation constitutes a multidisciplinary field that integrates computer graphics, dynamic simulation modeling, human–computer interaction, and artificial intelligence. It has evolved from an auxiliary tool into a core teaching methodology, becoming indispensable to modern medical education. Through the establishment of a high-fidelity digital ecosystem, this technology achieves the accurate reproduction of real clinical scenarios. It provides a reliable support platform for evidence-based teaching and practical clinical competency training. Medical imaging education is a critical component of clinical training, and the integration of virtual simulation technology has emerged as a key strategic approach to optimizing clinical teaching outcomes, bridging the gap between theoretical knowledge and clinical practice. Furthermore, medical imaging education aims to cultivate competent clinical imaging professionals with comprehensive practical capabilities. This descriptive single-center study focuses on the development, implementation, and evaluation of a specialty-oriented virtual simulation teaching system for medical imaging technology. The effectiveness of the system was evaluated by comparing pre- and post-training outcomes among participants with three different levels of technical experience. The key components of an effective virtual simulation teaching system include clear identification of user needs, selection of appropriate technological approaches, sufficient granularity in system design, and implementation of engaging interaction modalities. For the training assessment of the magnetic resonance imaging (MRI) section, the comprehensive skills related to fetal scanning improved in all subjects (54.19 ± 18.03 vs. 66.62 ± 12.41, p < 0.001) after virtual simulation training. Among technicians with different experiences, residents (42.38 ± 15.41 vs. 59.95 ± 12.63) and junior technicians (63.4 ± 12.13 vs. 73.07 ± 8.34, all p < 0.05) showed the most significant improvement after retraining. In contrast, the improvement among senior technicians (72.50 ± 7.89 vs. 73.83 ± 7.41, p = 0.117) was not significant. These findings suggest the potential application of virtual simulation in fetal prenatal screening training.
- 13 May 2026
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 64 (3) , 768-784
Relationship Between Dp140 Genotype and Cortical Similarity Network Phenotype in Duchenne Muscular Dystrophy: Preliminary T1 Weighted Study
Background: Dp140‐related mutations associate with neurodevelopmental impairments in Duchenne muscular dystrophy (DMD), their effects on cortical similarity network organization remain unclear. Purpose: To characterize alterations in morphometric similarity networks (MSN) in DMD with different Dp140 genotypes, assess their associations with clinical phenotypes and gene expression. Study Type: Prospective. Population: One hundred and fifteen boys with DMD (75 Dp140−: 9.63 ± 2.25 years; 40 Dp140+: 10.99 ± 2.25 years) and 69 healthy controls (all male, 10.65 ± 2.43 years). Field Strength/Sequence: Gradient echo at 3 T. Assessment: MRI were processed using FreeSurfer and GRETNA. Behavior data were based on Wechsler Intelligence Scale for children‐Fourth edition while transcriptional profiles were from the Allen Human Brain Atlas. Statistical Tests: Independent T ‐tests, chi‐square tests, general linear models, permutation testing, multivariable linear regression, mediation analyses, partial least squares regression, spatial permutation tests (Spin test), Gene Ontology enrichment analysis and cell‐type analysis. FDR‐corrected p < 0.05 and p spin < 0.05 were considered significant. Results: Dp140− subgroup had lower working memory index (WMI) than Dp140+ DMD (81.63 ± 15.48 vs. 90.78 ± 15.31; p = 0.01, Cohen's d = 0.179). Dp140− DMD showed reduced cortical similarity in bilateral lateral prefrontal cortex and parietal cortex regions, increased modular segregation (Hedge's g = −0.298, 95% CI [−0.408, −0.187]), and more hubs loss within frontal parietal network (FPN). The indirect effect of Dp140 genotype on WMI through mean FPN cortical similarity was significant ( β = −0.121, p = 0.03, 95% CI [−0.282, −0.001]). The Dp140‐specific MSN changes were spatially associated with transcriptional profile, which are enriched in neuronal projection development pathways of excitatory neurons ( p spin < 0.05). Data Conclusion: By linking genotype, neuroimaging, and transcriptional data, these findings offer further insight into mechanisms possibly involved in working memory deficits among Dp140− DMD. Evidence Level: 2. Technical Efficacy: Stage 2.
- 13 May 2026
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 64 (3) , 768-784
Relationship Between Dp140 Genotype and Cortical Similarity Network Phenotype in Duchenne Muscular Dystrophy: Preliminary T1 Weighted Study
Background: Dp140‐related mutations associate with neurodevelopmental impairments in Duchenne muscular dystrophy (DMD), their effects on cortical similarity network organization remain unclear. Purpose: To characterize alterations in morphometric similarity networks (MSN) in DMD with different Dp140 genotypes, assess their associations with clinical phenotypes and gene expression. Study Type: Prospective. Population: One hundred and fifteen boys with DMD (75 Dp140−: 9.63 ± 2.25 years; 40 Dp140+: 10.99 ± 2.25 years) and 69 healthy controls (all male, 10.65 ± 2.43 years). Field Strength/Sequence: Gradient echo at 3 T. Assessment: MRI were processed using FreeSurfer and GRETNA. Behavior data were based on Wechsler Intelligence Scale for children‐Fourth edition while transcriptional profiles were from the Allen Human Brain Atlas. Statistical Tests: Independent T ‐tests, chi‐square tests, general linear models, permutation testing, multivariable linear regression, mediation analyses, partial least squares regression, spatial permutation tests (Spin test), Gene Ontology enrichment analysis and cell‐type analysis. FDR‐corrected p < 0.05 and p spin < 0.05 were considered significant. Results: Dp140− subgroup had lower working memory index (WMI) than Dp140+ DMD (81.63 ± 15.48 vs. 90.78 ± 15.31; p = 0.01, Cohen's d = 0.179). Dp140− DMD showed reduced cortical similarity in bilateral lateral prefrontal cortex and parietal cortex regions, increased modular segregation (Hedge's g = −0.298, 95% CI [−0.408, −0.187]), and more hubs loss within frontal parietal network (FPN). The indirect effect of Dp140 genotype on WMI through mean FPN cortical similarity was significant ( β = −0.121, p = 0.03, 95% CI [−0.282, −0.001]). The Dp140‐specific MSN changes were spatially associated with transcriptional profile, which are enriched in neuronal projection development pathways of excitatory neurons ( p spin < 0.05). Data Conclusion: By linking genotype, neuroimaging, and transcriptional data, these findings offer further insight into mechanisms possibly involved in working memory deficits among Dp140− DMD. Evidence Level: 2. Technical Efficacy: Stage 2.
- Open Access
- 27 March 2026
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 21 (3) , e0345077
Prognostic value of cardiac magnetic resonance–derived global longitudinal strain in LGE-negative dilated cardiomyopathy
Background: Dilated cardiomyopathy (DCM) is a major cause of heart failure and sudden cardiac death (SCD), with a 5-year survival rate of approximately 45%–50%. Current risk stratification is predominantly dependent on left ventricular ejection fraction (LVEF), which has limited sensitivity and specificity. Hence, more effective biomarkers should be used in late gadolinium enhancement (LGE)-negative patients. Methods: A total of 378 consecutive patients with LGE-negative DCM were enrolled from four hospitals between December 2016 and December 2022. Cardiac magnetic resonance imaging-derived strain parameters (global radial strain, global circumferential strain, and global longitudinal strain [GLS]) were assessed against the primary (SCD and related events) and secondary (heart failure, appropriate implantable cardioverter-defibrillator therapy) endpoints. Internal validation was performed using stratified bootstrap resampling with Harrell’s optimism correction to report the optimism-corrected C-index. Data were accessed for research purposes from 15/06/2023–30/12/2023, and all records were de-identified prior to analysis. Results: Over a median follow-up of 59.78 months, 35 (9.26%) and 72 (19.0%) patients presented with the primary and secondary endpoints, respectively. Based on the multivariate Cox analysis, GLS, LVEF, and age were independent prognostic factors. However, only GLS (HR = 1.37; P = 0.041) remained significant in the LVEF P < 0.001). This advantage persisted after bootstrap internal validation (B = 1000; optimism-corrected C-index 0.754 vs 0.711, Holm adjusted P = 0.048). Further inclusion of age and New York Heart Association (NYHA) classification enhanced the model’s performance (model 4): apparent C-index 0.801; optimism-corrected C-index 0.785). Conclusion: GLS is an independent predictor of SCD-related events in LGE-negative DCM. Incorporating GLS with conventional indicators such as age, NYHA classification, and LVEF significantly enhances prognostic discrimination and model robustness, indicating potential value for future clinical risk stratification.
- 27 March 2026
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 21 (3) , e0345077
Open AccessPrognostic value of cardiac magnetic resonance–derived global longitudinal strain in LGE-negative dilated cardiomyopathy
Background: Dilated cardiomyopathy (DCM) is a major cause of heart failure and sudden cardiac death (SCD), with a 5-year survival rate of approximately 45%–50%. Current risk stratification is predominantly dependent on left ventricular ejection fraction (LVEF), which has limited sensitivity and specificity. Hence, more effective biomarkers should be used in late gadolinium enhancement (LGE)-negative patients. Methods: A total of 378 consecutive patients with LGE-negative DCM were enrolled from four hospitals between December 2016 and December 2022. Cardiac magnetic resonance imaging-derived strain parameters (global radial strain, global circumferential strain, and global longitudinal strain [GLS]) were assessed against the primary (SCD and related events) and secondary (heart failure, appropriate implantable cardioverter-defibrillator therapy) endpoints. Internal validation was performed using stratified bootstrap resampling with Harrell’s optimism correction to report the optimism-corrected C-index. Data were accessed for research purposes from 15/06/2023–30/12/2023, and all records were de-identified prior to analysis. Results: Over a median follow-up of 59.78 months, 35 (9.26%) and 72 (19.0%) patients presented with the primary and secondary endpoints, respectively. Based on the multivariate Cox analysis, GLS, LVEF, and age were independent prognostic factors. However, only GLS (HR = 1.37; P = 0.041) remained significant in the LVEF P < 0.001). This advantage persisted after bootstrap internal validation (B = 1000; optimism-corrected C-index 0.754 vs 0.711, Holm adjusted P = 0.048). Further inclusion of age and New York Heart Association (NYHA) classification enhanced the model’s performance (model 4): apparent C-index 0.801; optimism-corrected C-index 0.785). Conclusion: GLS is an independent predictor of SCD-related events in LGE-negative DCM. Incorporating GLS with conventional indicators such as age, NYHA classification, and LVEF significantly enhances prognostic discrimination and model robustness, indicating potential value for future clinical risk stratification.
- 1 April 2025
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 315 (1) , e251012
CT Myocardial Perfusion Imaging with Automated Postprocessing and Analysis Improves the Risk Evaluation of Coronary Artery Disease
- 1 April 2025
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 315 (1) , e251012
CT Myocardial Perfusion Imaging with Automated Postprocessing and Analysis Improves the Risk Evaluation of Coronary Artery Disease
- Open Access
- 22 March 2025
- Published by Elsevier in Journal of Cardiovascular Magnetic Resonance
- Vol. 27 (1) , 101885
Age-, body surface area-, and sex-specific reference values for cardiovascular magnetic resonance imaging derived ventricular and atrial size and function for Chinese healthy children
- 22 March 2025
- Published by Elsevier in Journal of Cardiovascular Magnetic Resonance
- Vol. 27 (1) , 101885
Open AccessAge-, body surface area-, and sex-specific reference values for cardiovascular magnetic resonance imaging derived ventricular and atrial size and function for Chinese healthy children
- 4 March 2025
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 62 (2) , 457-467
Multi‐Parametric Quantitative MRI in the Early Differential Diagnosis of Ambulatory Children With Duchenne Muscular Dystrophy and Becker Muscular Dystrophy
Background: Duchenne muscular dystrophy (DMD) and Becker muscular dystrophy (BMD), the most common dystrophinopathies, require distinct treatments. Corticosteroids are effective for DMD but less so for BMD. Early diagnosis can improve DMD outcomes and prevent BMD overtreatment. However, differentiating them in younger children with mild symptoms is challenging due to overlapping features.Purpose: To evaluate the performance of multi‐parametric quantitative MRI (qMRI) in early differentiation between BMD and DMD, particularly among younger patients in the mild disease stage.Study Type: Prospective.Subjects: 121 DMD males (mean age 8.5 ± 1.6 years), 28 BMD males (9.7 ± 3.3 years), and 26 male healthy controls (HCs) (9.4 ± 2.7 years).Field Strength/Sequence: 3.0T/3‐point Dixon (fast‐spin‐echo), T1‐mapping (modified‐Look‐Locker‐inversion‐recovery), and T2‐mapping (balance‐steady‐state‐free‐precession).Assessment: qMRI measurements (fat fraction [FF], T1, and T2) in 18 pelvic and thigh muscles were conducted. A linearized NorthStar ambulatory assessment (NSAA) score was used to evaluate the function status, with a mild functional decline stage defined as a score of 76–100.Statistical Tests: Mann–Whitney test, Kruskal–Wallis test, and Receiver operating characteristic curves. A P‐value < 0.05 was considered statistically significant.Results: In all subject groups, DMD exhibits significantly higher FF and T2 and lower T1 compared to BMD. The max differences in mean FF, T1, and T2 was 45.29%, 543 ms, and 31.0 ms, respectively. Overall, the area under curve (AUC) values for FF surpassed those for T2 and T1 in the majority of muscles. In the mild subgroup below 10 years old, DMD had significantly higher FF and T1 than BMD. The combination of FF and T1 in gluteus medius, rectus femoris, vastus lateralis, vastus intermedius, vastus medialis, and adductor magnus achieved higher AUCs (0.816–0.957) than FF (0.773–0.862) or T1 (0.701–0.819) in differentiating the two subgroups.Data Conclusion: Multi‐parametric qMRI demonstrates potential as an effective tool for early differentiation between DMD and BMD.Evidence Level: 2Technical Efficacy: Stage 3
- 4 March 2025
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 62 (2) , 457-467
Multi‐Parametric Quantitative MRI in the Early Differential Diagnosis of Ambulatory Children With Duchenne Muscular Dystrophy and Becker Muscular Dystrophy
Background: Duchenne muscular dystrophy (DMD) and Becker muscular dystrophy (BMD), the most common dystrophinopathies, require distinct treatments. Corticosteroids are effective for DMD but less so for BMD. Early diagnosis can improve DMD outcomes and prevent BMD overtreatment. However, differentiating them in younger children with mild symptoms is challenging due to overlapping features.Purpose: To evaluate the performance of multi‐parametric quantitative MRI (qMRI) in early differentiation between BMD and DMD, particularly among younger patients in the mild disease stage.Study Type: Prospective.Subjects: 121 DMD males (mean age 8.5 ± 1.6 years), 28 BMD males (9.7 ± 3.3 years), and 26 male healthy controls (HCs) (9.4 ± 2.7 years).Field Strength/Sequence: 3.0T/3‐point Dixon (fast‐spin‐echo), T1‐mapping (modified‐Look‐Locker‐inversion‐recovery), and T2‐mapping (balance‐steady‐state‐free‐precession).Assessment: qMRI measurements (fat fraction [FF], T1, and T2) in 18 pelvic and thigh muscles were conducted. A linearized NorthStar ambulatory assessment (NSAA) score was used to evaluate the function status, with a mild functional decline stage defined as a score of 76–100.Statistical Tests: Mann–Whitney test, Kruskal–Wallis test, and Receiver operating characteristic curves. A P‐value < 0.05 was considered statistically significant.Results: In all subject groups, DMD exhibits significantly higher FF and T2 and lower T1 compared to BMD. The max differences in mean FF, T1, and T2 was 45.29%, 543 ms, and 31.0 ms, respectively. Overall, the area under curve (AUC) values for FF surpassed those for T2 and T1 in the majority of muscles. In the mild subgroup below 10 years old, DMD had significantly higher FF and T1 than BMD. The combination of FF and T1 in gluteus medius, rectus femoris, vastus lateralis, vastus intermedius, vastus medialis, and adductor magnus achieved higher AUCs (0.816–0.957) than FF (0.773–0.862) or T1 (0.701–0.819) in differentiating the two subgroups.Data Conclusion: Multi‐parametric qMRI demonstrates potential as an effective tool for early differentiation between DMD and BMD.Evidence Level: 2Technical Efficacy: Stage 3
- 2 December 2024
- Published by Springer Nature in Pediatric Radiology
- Vol. 55 (1) , 136-150
Multi-parameter quantitative magnetic resonance imaging for early detecting skeletal muscle involvement and predicting functional decline in children with Becker muscular dystrophy
Background The extreme clinical heterogeneity of children with Becker muscular dystrophy significantly poses a great challenge to accurately assess their disease status. Objective To detect skeletal muscle involvement in children with Becker muscular dystrophy using multiple-parameter quantitative magnetic resonance imaging (qMRI), and to determine the preferred muscle site and qMRI biomarker. Materials and methods Fat fraction, T1, and T2 measurements were conducted in Becker muscular dystrophy (n=29) and healthy controls (n=23). North Star Ambulatory Assessment (NSAA) was performed in Becker muscular dystrophy. Group differences were compared by using the Mann–Whitney or Kruskal–Wallis test or a linear mixed-effect model. Receiver operating characteristic analysis with area under curve (AUC) was used to compare the diagnostic performance. Logistic regression was used to identify the predictor of functional decline. Results Both fat fraction and T2 were effective in detecting muscle involvement across different functional stages that were categorized by NSAA, with fat fraction in gluteus maximus demonstrating the most superior diagnostic performance (AUC range, 0.85–0.98). The combination of T2 and T1 enables a good diagnosis of no abnormal fat–infiltrated muscles (AUC=0.82). Overall, fat fraction in gluteus maximus exhibited the strongest negative correlation with the NSAA score (r=-0.69, PP=0.02). Conclusion Multi-parametric qMRI demonstrate effective capabilities for early detection of muscle involvement, with gluteus maximus being the preferred muscle site. Fat fraction in gluteus maximus may serve as a potential biomarker for predicting functional decline. Graphical Abstract
- 2 December 2024
- Published by Springer Nature in Pediatric Radiology
- Vol. 55 (1) , 136-150
Multi-parameter quantitative magnetic resonance imaging for early detecting skeletal muscle involvement and predicting functional decline in children with Becker muscular dystrophy
Background The extreme clinical heterogeneity of children with Becker muscular dystrophy significantly poses a great challenge to accurately assess their disease status. Objective To detect skeletal muscle involvement in children with Becker muscular dystrophy using multiple-parameter quantitative magnetic resonance imaging (qMRI), and to determine the preferred muscle site and qMRI biomarker. Materials and methods Fat fraction, T1, and T2 measurements were conducted in Becker muscular dystrophy (n=29) and healthy controls (n=23). North Star Ambulatory Assessment (NSAA) was performed in Becker muscular dystrophy. Group differences were compared by using the Mann–Whitney or Kruskal–Wallis test or a linear mixed-effect model. Receiver operating characteristic analysis with area under curve (AUC) was used to compare the diagnostic performance. Logistic regression was used to identify the predictor of functional decline. Results Both fat fraction and T2 were effective in detecting muscle involvement across different functional stages that were categorized by NSAA, with fat fraction in gluteus maximus demonstrating the most superior diagnostic performance (AUC range, 0.85–0.98). The combination of T2 and T1 enables a good diagnosis of no abnormal fat–infiltrated muscles (AUC=0.82). Overall, fat fraction in gluteus maximus exhibited the strongest negative correlation with the NSAA score (r=-0.69, PP=0.02). Conclusion Multi-parametric qMRI demonstrate effective capabilities for early detection of muscle involvement, with gluteus maximus being the preferred muscle site. Fat fraction in gluteus maximus may serve as a potential biomarker for predicting functional decline. Graphical Abstract
- Open Access
- 15 November 2024
- Published by Wolters Kluwer Health in Medicine
- Vol. 103 (46) , e39724
Myocardial involvement in end-stage renal disease patients with anemia as assessed by cardiovascular magnetic resonance native T1 mapping: An observational study
Cardiovascular disease has become to the main cause of death in the patients with end-stage renal disease (ESRD), and anemia is associated with increased cardiovascular morbidity and mortality in these patients. This study aimed to explore the impact of anemia on myocardial fibrosis using T1 mapping technique in patients with ESRD. A total of 128 subjects including 98 ESRD patients (65 with anemia, 33 without anemia) and 30 normal controls were enrolled. All subjects were underwent cardiovascular magnetic resonance to obtain cardiac cine and T1 mapping images. As potential markers of fibrosis, native T1 values and global longitudinal strain derived by feature-tracking technique were compared. Differences between 3 groups were analyzed using one-way analysis of variance. Associations between variables were assessed by Pearson and Spearman correlation coefficient appropriately. An independent association was identified by the multiple stepwise linear regression analysis. Intraclass correlation was applied to assess observer variability. In all ESRD patients, native T1 values were significantly longer than those of normal controls (global T1, 1357 ± 42 ms vs 1275 ± 48 ms, P < .001). Global T1 value in ESRD patients with anemia was significantly higher (1375 ± 36 ms) compared to that in ESRD patients without anemia (1322 ± 25 ms) and normal controls (1275 ± 48 ms), respectively (all P < .001). Global T1 correlated with hemoglobin negatively (R= −0.499, P < .001). Multiple stepwise linear regression analysis presented the anemia is independently associated with global T1 (R = 0.607, P < .001). Global longitudinal strain was remarkably reduced in ESRD patients with anemia in comparison to those without anemia (P < .001). Diffuse myocardial fibrosis could be detected by native T1 mapping in ESRD patients with long-term anemia. Anemia is an important factor in myocardial fibrosis in ESRD patients, and the evaluation of myocardial involvement is worth considering for clinical management.
- 15 November 2024
- Published by Wolters Kluwer Health in Medicine
- Vol. 103 (46) , e39724
Open AccessMyocardial involvement in end-stage renal disease patients with anemia as assessed by cardiovascular magnetic resonance native T1 mapping: An observational study
Cardiovascular disease has become to the main cause of death in the patients with end-stage renal disease (ESRD), and anemia is associated with increased cardiovascular morbidity and mortality in these patients. This study aimed to explore the impact of anemia on myocardial fibrosis using T1 mapping technique in patients with ESRD. A total of 128 subjects including 98 ESRD patients (65 with anemia, 33 without anemia) and 30 normal controls were enrolled. All subjects were underwent cardiovascular magnetic resonance to obtain cardiac cine and T1 mapping images. As potential markers of fibrosis, native T1 values and global longitudinal strain derived by feature-tracking technique were compared. Differences between 3 groups were analyzed using one-way analysis of variance. Associations between variables were assessed by Pearson and Spearman correlation coefficient appropriately. An independent association was identified by the multiple stepwise linear regression analysis. Intraclass correlation was applied to assess observer variability. In all ESRD patients, native T1 values were significantly longer than those of normal controls (global T1, 1357 ± 42 ms vs 1275 ± 48 ms, P < .001). Global T1 value in ESRD patients with anemia was significantly higher (1375 ± 36 ms) compared to that in ESRD patients without anemia (1322 ± 25 ms) and normal controls (1275 ± 48 ms), respectively (all P < .001). Global T1 correlated with hemoglobin negatively (R= −0.499, P < .001). Multiple stepwise linear regression analysis presented the anemia is independently associated with global T1 (R = 0.607, P < .001). Global longitudinal strain was remarkably reduced in ESRD patients with anemia in comparison to those without anemia (P < .001). Diffuse myocardial fibrosis could be detected by native T1 mapping in ESRD patients with long-term anemia. Anemia is an important factor in myocardial fibrosis in ESRD patients, and the evaluation of myocardial involvement is worth considering for clinical management.
- 23 May 2024
- Published by Elsevier in International Journal of Cardiology
- Vol. 409, 132194
More attention needs to focus on the diabetic cardiomyopathy without coronary artery disease
- 23 May 2024
- Published by Elsevier in International Journal of Cardiology
- Vol. 409, 132194
More attention needs to focus on the diabetic cardiomyopathy without coronary artery disease
- Open Access
- 15 April 2024
- Published by BMJ in Journal of Medical Genetics
- Vol. 61 (8) , 741-749
Novel mutation leading to splice donor loss in a conserved site of DMD gene causes Duchenne muscular dystrophy with cryptorchidism
Background: As one of the most common congenital abnormalities in male births, cryptorchidism has been found to have a polygenic aetiology according to previous studies of common variants. However, little is known about genetic predisposition of rare variants for cryptorchidism, since rare variants have larger effective size on diseases than common variants. Methods: In this study, a cohort of 115 Chinese probands with cryptorchidism was analysed using whole-genome sequencing, alongside 19 parental controls and 2136 unaffected men. Additionally, CRISPR-Cas9 editing of a conserved variant was performed in a mouse model, with MRI screening used to observe the phenotype. Results: In 30 of 115 patients (26.1%), we identified four novel genes (ARSH, DMD, MAGEA4 and SHROOM2) affecting at least five unrelated patients and four known genes (USP9Y, UBA1, BCORL1 and KDM6A) with the candidate rare pathogenic variants affecting at least two cases. Burden tests of rare variants revealed the genome-wide significances for newly identified genes (pG), which resides in a conserved site across vertebrates, replicated bilateral cryptorchidism phenotypes, confirmed by MRI at 4 and 10 weeks. The movement tests further revealed symptoms of Duchenne muscular dystrophy (DMD) in transgenic mice. Conclusion: Our results revealed the role of the DMD gene mutation in causing cryptorchidism. The results also suggest that maternal-X inheritance of pathogenic defects could have a predominant role in the development of cryptorchidism.
- 15 April 2024
- Published by BMJ in Journal of Medical Genetics
- Vol. 61 (8) , 741-749
Open AccessNovel mutation leading to splice donor loss in a conserved site of DMD gene causes Duchenne muscular dystrophy with cryptorchidism
Background: As one of the most common congenital abnormalities in male births, cryptorchidism has been found to have a polygenic aetiology according to previous studies of common variants. However, little is known about genetic predisposition of rare variants for cryptorchidism, since rare variants have larger effective size on diseases than common variants. Methods: In this study, a cohort of 115 Chinese probands with cryptorchidism was analysed using whole-genome sequencing, alongside 19 parental controls and 2136 unaffected men. Additionally, CRISPR-Cas9 editing of a conserved variant was performed in a mouse model, with MRI screening used to observe the phenotype. Results: In 30 of 115 patients (26.1%), we identified four novel genes (ARSH, DMD, MAGEA4 and SHROOM2) affecting at least five unrelated patients and four known genes (USP9Y, UBA1, BCORL1 and KDM6A) with the candidate rare pathogenic variants affecting at least two cases. Burden tests of rare variants revealed the genome-wide significances for newly identified genes (pG), which resides in a conserved site across vertebrates, replicated bilateral cryptorchidism phenotypes, confirmed by MRI at 4 and 10 weeks. The movement tests further revealed symptoms of Duchenne muscular dystrophy (DMD) in transgenic mice. Conclusion: Our results revealed the role of the DMD gene mutation in causing cryptorchidism. The results also suggest that maternal-X inheritance of pathogenic defects could have a predominant role in the development of cryptorchidism.