Oleg P. Tolbanov
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Oleg P. Tolbanov has a total of 57 co-authors. Here are the top co-authors by number of shared publications:
- Anton V. Tyazhev
National Research Tomsk State University, Tomsk, Russian Federation
12 shared publications - Andrei Zarubin
National Research Tomsk State University, Tomsk, Russian Federation
8 shared publications - A. V. Shemeryankina
National Research Tomsk State University, Tomsk, Russian Federation
5 shared publications - Pavel. V. Kosmachev
Microelectronics of Multispectral Quantum Introscopy Laboratory of the R&D Center “Advanced Electronic Technologies”, National Research Tomsk State University, 634050 Tomsk, Russia
5 shared publications - Ilya A. Prudaev
National Research Tomsk State University, Tomsk, Russia
4 shared publications - M. S. Skakunov
National Research Tomsk State University, Tomsk, Russian Federation
4 shared publications
Latest Publications
- 1 November 2025
- Published by Springer Nature in Russian Physics Journal
- Vol. 68 (11) , 1975-1983
Steady-state current-voltage characteristics and electric field profiles in multi-element HR-GaAs:Cr X-ray sensors
- 1 November 2025
- Published by Springer Nature in Russian Physics Journal
- Vol. 68 (11) , 1975-1983
Steady-state current-voltage characteristics and electric field profiles in multi-element HR-GaAs:Cr X-ray sensors
- 1 October 2025
- Published by Springer Nature in Russian Physics Journal
- Vol. 68 (10) , 1525-1537
Photocurrent of X-ray sensors made of single crystal sapphire and undoped silicon carbide under irradiation by polychromatic X-ray
- 1 October 2025
- Published by Springer Nature in Russian Physics Journal
- Vol. 68 (10) , 1525-1537
Photocurrent of X-ray sensors made of single crystal sapphire and undoped silicon carbide under irradiation by polychromatic X-ray
- 1 May 2025
- Published by Springer Nature in Russian Physics Journal
- Vol. 68 (5) , 722-730
Simulation of lateral distribution of resistivity and charge carrier lifetime in chromium-compensated gallium arsenide wafers
- 1 May 2025
- Published by Springer Nature in Russian Physics Journal
- Vol. 68 (5) , 722-730
Simulation of lateral distribution of resistivity and charge carrier lifetime in chromium-compensated gallium arsenide wafers
- 1 March 2025
- Published by Springer Nature in Russian Physics Journal
- Vol. 68 (3) , 471-478
Fast SR beam position and intensity monitor for the experiments to study fast-flowing processes
- 1 March 2025
- Published by Springer Nature in Russian Physics Journal
- Vol. 68 (3) , 471-478
Fast SR beam position and intensity monitor for the experiments to study fast-flowing processes
- 1 March 2025
- Published by Springer Nature in Russian Physics Journal
- Vol. 68 (3) , 461-470
Sapphire dosimetric sensors for carbon ion beam radiation therapy
- 1 March 2025
- Published by Springer Nature in Russian Physics Journal
- Vol. 68 (3) , 461-470
Sapphire dosimetric sensors for carbon ion beam radiation therapy
- 1 February 2025
- Published by Springer Nature in Russian Physics Journal
- Vol. 68 (2) , 244-255
Development of detectors for 1–3 fast processes station of SKIF center for collective use
- 1 February 2025
- Published by Springer Nature in Russian Physics Journal
- Vol. 68 (2) , 244-255
Development of detectors for 1–3 fast processes station of SKIF center for collective use
- Open Access
Radiographic Inspection of Carbon Fiber-Reinforced Polymer Composites (Laminates) with Epoxy and PEEK Binders After Impact and Subsequent Compression Loading
An approach to detecting discontinuities in carbon fiber-reinforced polymers, caused by impact loading followed by compression testing, was developed. An X-ray sensor-based installation was used, while some algorithms were developed to improve the quality of the obtained low-contrast radiographic images with negligible signal-to-noise ratios. For epoxy/AF (#1) composite subjected to a “high-velocity” steel-ball impact with subsequent compression loading, it was not possible to detect discontinuities since the orientation of the extended zone of interlayer delamination was perpendicular to the irradiation axis. After drop-weight impacts with subsequent compression loading of epoxy/CF (#2) and PEEK/CF (#3) composites, the main cracks were formed in their central parts. This area was reliably detected through the improved radiographic images being more contrasted compared to that for composite #3, for which the damaged area was similar in shape but smaller. The phase variation and congruency methods were employed to highlight low-contrast objects in the radiographic images. The phase variation procedure showed higher efficiency in detecting small objects, while phase congruency is preferable for highlighting large objects. To assess the degree of image improvement, several metrics were implemented. In the analysis of the model images, the most indicative was the PSNR parameter (with a S-N ratio greater than the unit), confirming an increase in image contrast and a decrease in noise level. The NIQE and PIQE parameters enabled the correct assessment of image quality even with the S-N ratio being less than a unit.
Open AccessRadiographic Inspection of Carbon Fiber-Reinforced Polymer Composites (Laminates) with Epoxy and PEEK Binders After Impact and Subsequent Compression Loading
An approach to detecting discontinuities in carbon fiber-reinforced polymers, caused by impact loading followed by compression testing, was developed. An X-ray sensor-based installation was used, while some algorithms were developed to improve the quality of the obtained low-contrast radiographic images with negligible signal-to-noise ratios. For epoxy/AF (#1) composite subjected to a “high-velocity” steel-ball impact with subsequent compression loading, it was not possible to detect discontinuities since the orientation of the extended zone of interlayer delamination was perpendicular to the irradiation axis. After drop-weight impacts with subsequent compression loading of epoxy/CF (#2) and PEEK/CF (#3) composites, the main cracks were formed in their central parts. This area was reliably detected through the improved radiographic images being more contrasted compared to that for composite #3, for which the damaged area was similar in shape but smaller. The phase variation and congruency methods were employed to highlight low-contrast objects in the radiographic images. The phase variation procedure showed higher efficiency in detecting small objects, while phase congruency is preferable for highlighting large objects. To assess the degree of image improvement, several metrics were implemented. In the analysis of the model images, the most indicative was the PSNR parameter (with a S-N ratio greater than the unit), confirming an increase in image contrast and a decrease in noise level. The NIQE and PIQE parameters enabled the correct assessment of image quality even with the S-N ratio being less than a unit.
- 20 September 2024
- Published by Springer Nature in Russian Physics Journal
- Vol. 67 (9) , 1492-1499
Electronic Properties of Highly Compensated Semiconductors: The HR-GaAs:Cr Material
- 20 September 2024
- Published by Springer Nature in Russian Physics Journal
- Vol. 67 (9) , 1492-1499
Electronic Properties of Highly Compensated Semiconductors: The HR-GaAs:Cr Material
- 16 November 2023
- Published by Springer Nature in Russian Physics Journal
- Vol. 66 (7) , 771-778
Multi-Spectral X-Ray Detectors for Nondestructive Testing of 3D Printed Polymer Composites
- 16 November 2023
- Published by Springer Nature in Russian Physics Journal
- Vol. 66 (7) , 771-778
Multi-Spectral X-Ray Detectors for Nondestructive Testing of 3D Printed Polymer Composites
- 1 April 2022
- Published by Springer Nature in Russian Physics Journal
- Vol. 64 (12) , 2350-2356
Formation of Dislocations in the Process of Impurity Diffusion in GaAs
- 1 April 2022
- Published by Springer Nature in Russian Physics Journal
- Vol. 64 (12) , 2350-2356
Formation of Dislocations in the Process of Impurity Diffusion in GaAs