CMChuang-Chuang Mu

Chuang-Chuang Mu

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Chuang-Chuang Mu has a total of 20 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    The tooth movement efficiency of different orthodontic thermoplastics for clear aligners: study protocol for a randomized controlled clinical trial

    by Chuangchuang Mu, Bingjing Sun, Zhicheng Gong, Yuanyuan Wei, Li Chen, Wei Zhang, Haimiao Wu, Bingjiao Zhao

    Introduction: With regard to the esthetics and comfort of orthodontic treatment, the requirement for removable clear aligners (CAs) is increasing. Unlike conventional fixed orthodontic appliances, CAs were made of thermoplastic film by thermoforming on the personalized dental models. The construction of orthodontic thermoplastic is a critical factor for orthodontic tooth movement (OTM). Polyethylene terephthalate glycol-modified (PETG) and thermoplastic polyurethane (TPU) are the most commonly orthodontic thermoplastics, however, the evidence of the differences between different orthodontic thermoplastic are limited to vitro environment and the evidence in vivo environment is not available. Therefore, this trial aims to provide reliable evidence for orthodontists’ personalized treatment plans whether the two most commonly used orthodontic thermoplastics of PETG and TPU have differences in the efficiency of OTM. Methods and analysis: This randomized controlled clinical study will recruit 44 orthodontic patients for orthodontic treatment. All the subjects will be randomized into two groups (PETG and TPU, n = 22 for each group). In the first stage (M0 to M1), clear aligners will be made of two orthodontic thermoplastics and move the maxillary first or second premolars 2mm. In the second stage, patients will take the standard orthodontic treatments. The primary outcome will be the efficiency of clear aligners made of different materials on the digital models. The secondary outcome will be the efficiency of clear aligners made of different materials on the cone-beam computed tomography (CBCT). The efficiency will be calculated through the superimposition of the digital models and CBCT. Discussion: The results from this trial will serve as evidence for orthodontists and manufacturers and clarify whether the difference in orthodontic thermoplastics significantly impacts the efficiency of OTM. Trial registration number: ChiCTR2300070980. Registered on 27 April 2023. https://www.chictr.org.cn/showproj.html?proj=186253

  • Open Access

    Detection of vertical root fractures by cone-beam computed tomography based on deep learning

    by Pan Yang, Xiaolong Guo, Chuangchuang Mu, Senrong Qi, Gang Li

    Objectives: This study aims to evaluate the performance of ResNet models in the detection of in vitro and in vivo vertical root fractures (VRF) in Cone-beam Computed Tomography (CBCT) images. Methods: A CBCT image dataset consisting of 28 teeth (14 intact and 14 teeth with VRF, 1641 slices) from 14 patients, and another dataset containing 60 teeth (30 intact and 30 teeth with VRF, 3665 slices) from an in vitro model were used for the establishment of VRFconvolutional neural network (CNN) models. The most popular CNN architecture ResNet with different layers was fine-tuned for the detection of VRF. Sensitivity, specificity, accuracy, PPV (positive predictive value), NPV (negative predictive value), and AUC (the area under the receiver operating characteristic curve) of the VRF slices classified by the CNN in the test set were compared. Two oral and maxillofacial radiologists independently reviewed all the CBCT images of the test set, and intraclass correlation coefficients (ICCs) were calculated to assess the interobserver agreement for the oral maxillofacial radiologists. Results: The AUC of the models on the patient data were: 0.827(ResNet-18), 0.929(ResNet-50), and 0.882(ResNet-101). The AUC of the models on the mixed data get improved as:0.927(ResNet-18), 0.936(ResNet-50), and 0.893(ResNet-101). The maximum AUC were: 0.929 (0.908–0.950, 95% CI) and 0.936 (0.924–0.948, 95% CI) for the patient data and mixed data from ResNet-50, which is comparable to the AUC (0.937 and 0.950) for patient data and (0.915 and 0.935) for the mixed data obtained from the two oral and maxillofacial radiologists, respectively. Conclusions: Deep-learning models showed high accuracy in the detection of VRF using CBCT images. The data obtained from the in vitro VRF model increases the data scale, which is beneficial to the training of deep-learning models.


  • Diagnostic efficacy of CBCT, MRI and CBCT–MRI fused images in determining anterior disc displacement and bone changes of temporomandibular joint

    by Ying-Hui Wang, Ruo-Han Ma, Jia-Jun Li, Chuang-Chuang Mu, Yan-Ping Zhao, Juan-Hong Meng, Gang Li

    Objectives: To evaluate the diagnostic efficacy of CBCT–MRI fused image for anterior disc displacement and bone changes of temporomandibular joint (TMJ), which are the main imaging manifestations of temporomandibular disorders (TMD). Methods: Two hundred and thirty-one TMJs of 120 patients who were diagnosed with TMD were selected for the study. The anterior disc displacement, bone defect and bone hyperplasia evaluated by three experts were used as a reference standard. Three residents individually evaluated all the three sets of images, which were CBCT images, MRI images and CBCT-MRI fused images from individual CBCT and MRI images in a random order for the above-mentioned three imaging manifestations with a five-point scale. Each set of images was observed at least 1 week apart. A second evaluation was performed 4 weeks later. Intra- and interobserver agreements were assessed using the intraclass correlation coefficient (ICC). The areas under the ROC curves (AUCs) of the three image sets were compared with a Z test, and p < 0.05 was considered statistically significant. Results: One hundred and forty-five cases were determined as anterior disc displacement, 84 cases as bone defect and 40 cases as bone hyperplasia. The intra- and interobserver agreements in the CBCT-MRI fused image set (0.76–0.91) were good to excellent, and the diagnostic accuracy for bone changes was significantly higher than that of MRI image set (p<0.05). Conclusions: CBCT-MRI fused images can display the disc and surrounding bone structures simultaneously and significantly improve the observers’ reliability and diagnostic accuracy, especially for inexperienced residents.


  • Diagnostic efficacy of CBCT, MRI, and CBCT-MRI fused images in distinguishing articular disc calcification from loose body of temporomandibular joint

    by Ying-Hui Wang, Gang Li, Ruo-Han Ma, Yan-Ping Zhao, Hao Zhang, Juan-Hong Meng, Chuang-Chuang Mu, Chong-Ke Sun, Xu-Chen Ma

    Objectives To evaluate the diagnostic efficacy of CBCT-MRI fused images for articular disc calcification of temporomandibular joint (TMJ). Materials and methods Twenty patients (24 TMJs) whose image examinations showed dense bodies in the TMJ space were included in the study. The locations of dense bodies evaluated by the three experts were used as a reference standard. Three oral and maxillofacial radiology residents evaluated whether the dense bodies were disc calcification or not, with a five-point scale for four sets of images (CBCT alone, MRI alone, both CBCT and MRI observed at a time, and CBCT-MRI fused images) randomly and independently. Each set of images was observed at least 1 week apart. A second evaluation was performed after 4 weeks. Intraclass correlation coefficients were calculated to assess the intra- and inter-observer agreement. The areas under the ROC curves (AUCs) were compared between the four image sets using Z test. Results Ten cases were determined as articular disc calcifications, and fourteen cases were recognized as loose bodies in the TMJ spaces. The average AUC index for the CBCT-MRI fused images was 0.95 and significantly higher than the other sets (p < 0.01). The intra- and inter-observer agreement in the CBCT-MRI fused images (0.90–0.91, 0.93) was excellent and higher than those in the other images. Conclusions CBCT-MRI fused images can significantly improve the observers’ reliability and accuracy in determining articular disc calcification of the TMJ. Clinical relevance The multimodality image fusion is feasible in detecting articular disc calcification of the TMJ which are hard to define by CBCT or MRI alone. It can be utilized especially for inexperienced residents to shorten the learning curve and improve diagnostic accuracy.