Zhitao Zhou
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Zhitao Zhou has a total of 80 co-authors. Here are the top co-authors by number of shared publications:
- Tiger H. Tao
State Key Laboratory of Transducer Technology, Shanghai Institute of Microsystem and Information Technology, Chinese Academy of Sciences, Shanghai 200050, China
10 shared publications - Liuyang Sun
State Key Laboratory of Transducer Technology, Shanghai Institute of Microsystem and Information Technology, Chinese Academy of Sciences, Shanghai 200050, China
9 shared publications - Xiaoling Wei
State Key Laboratory of Transducer Technology, Shanghai Institute of Microsystem and Information Technology, Chinese Academy of Sciences, Shanghai 200050, China
9 shared publications Xiner Wang
2020 X-Lab, Shanghai Institute of Microsystem and Information Technology, Chinese Academy of Sciences, Shanghai, China
6 shared publicationsJizhi Liang
2020 X‐Lab Shanghai Institute of Microsystem and Information Technology Chinese Academy of Sciences Shanghai 200050 China
4 shared publicationsZhaohan Chen
Neuroxess Co., Ltd, Shanghai, China
4 shared publications
Latest Publications
- Open Access
- 13 November 2026
- Published by MDPI AG in Micromachines
- Vol. 17 (11) , 1320
Correction: Wang et al. Ultraflexible PEDOT:PSS/IrOx-Modified Electrodes: Applications in Behavioral Modulation and Neural Signal Recording in Mice. Micromachines 2024, 15, 447
- 13 November 2026
- Published by MDPI AG in Micromachines
- Vol. 17 (11) , 1320
Open AccessCorrection: Wang et al. Ultraflexible PEDOT:PSS/IrOx-Modified Electrodes: Applications in Behavioral Modulation and Neural Signal Recording in Mice. Micromachines 2024, 15, 447
- Open Access
- 17 April 2026
- Published by Association for Computing Machinery (ACM)
- p. 368-375
Assessing the Relationship between Cross-Frequency Coupling and Movement Decoding Performance Using High-Density ECoG
- 17 April 2026
- Published by Association for Computing Machinery (ACM)
- p. 368-375
Open AccessAssessing the Relationship between Cross-Frequency Coupling and Movement Decoding Performance Using High-Density ECoG
- Open Access
- 7 November 2025
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 11 (45) , eadz9968
Real-time decoding of full-spectrum Chinese using brain-computer interface
Speech brain-computer interfaces (BCIs) offer a promising means to provide functional communication capacity for patients with anarthria caused by neurological conditions such as amyotrophic lateral sclerosis (ALS) or brainstem stroke. Current speech decoding research has predominantly focused on English using phoneme-driven architectures, whereas real-time decoding of tonal monosyllabic languages such as Mandarin Chinese remains a major challenge. This study demonstrates a real-time Mandarin speech BCI that decodes monosyllabic units directly from neural signals. Using the 256-channel microelectrocorticographic BCI, we achieved robust decoding of a comprehensive set of 394 distinct syllables based purely on neural signals, yielding median syllable identification accuracy of 71.2% in a single-character reading task. Leveraging this high-performing syllable decoder, we further demonstrated real-time sentence decoding. Our findings demonstrate the efficacy of a tonally integrated, direct syllable neural decoding approach for Mandarin Chinese, paving the way for full-coverage systems in tonal monosyllabic languages.
- 7 November 2025
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 11 (45) , eadz9968
Open AccessReal-time decoding of full-spectrum Chinese using brain-computer interface
Speech brain-computer interfaces (BCIs) offer a promising means to provide functional communication capacity for patients with anarthria caused by neurological conditions such as amyotrophic lateral sclerosis (ALS) or brainstem stroke. Current speech decoding research has predominantly focused on English using phoneme-driven architectures, whereas real-time decoding of tonal monosyllabic languages such as Mandarin Chinese remains a major challenge. This study demonstrates a real-time Mandarin speech BCI that decodes monosyllabic units directly from neural signals. Using the 256-channel microelectrocorticographic BCI, we achieved robust decoding of a comprehensive set of 394 distinct syllables based purely on neural signals, yielding median syllable identification accuracy of 71.2% in a single-character reading task. Leveraging this high-performing syllable decoder, we further demonstrated real-time sentence decoding. Our findings demonstrate the efficacy of a tonally integrated, direct syllable neural decoding approach for Mandarin Chinese, paving the way for full-coverage systems in tonal monosyllabic languages.
- Open Access
- 23 October 2025
- Published by Springer Nature in Nature Communications
- Vol. 16 (1) , 1-14
Silk-enabled conformal intraventricular interfaces for minimally invasive neural recordings
Flexible neural interfaces capable of monitoring subcortical neuronal activity facilitate the study of deep brain neural circuits and their interactions with the cortex. However, there exists a paucity of translational tools for interfacing subcortical nuclei surfaces within the intraventricular cerebrospinal fluid. Here, we developed a flexible and conformal intraventricular interface (IVI) featuring a deformable microelectrode array paired with a silk scaffold. The IVI can be minimally invasively implanted into the lateral ventricles with the assistance of commonly used clinical catheters, self-unfolding in the cerebrospinal fluid environment to conformally attach to the surfaces of periventricular neural structures, and capturing high-quality signals by virtue of the microelectrode’s in-plane shielding. In parkinsonian ewes, the IVI detects deep brain abnormalities and achieves stable, biocompatible in vivo recordings for four weeks. This platform enables chronic monitoring and circuit analysis of healthy and diseased deep brain regions, facilitating studies of neural circuits between periventricular surface neurons and distant brain areas.
- 23 October 2025
- Published by Springer Nature in Nature Communications
- Vol. 16 (1) , 1-14
Open AccessSilk-enabled conformal intraventricular interfaces for minimally invasive neural recordings
Flexible neural interfaces capable of monitoring subcortical neuronal activity facilitate the study of deep brain neural circuits and their interactions with the cortex. However, there exists a paucity of translational tools for interfacing subcortical nuclei surfaces within the intraventricular cerebrospinal fluid. Here, we developed a flexible and conformal intraventricular interface (IVI) featuring a deformable microelectrode array paired with a silk scaffold. The IVI can be minimally invasively implanted into the lateral ventricles with the assistance of commonly used clinical catheters, self-unfolding in the cerebrospinal fluid environment to conformally attach to the surfaces of periventricular neural structures, and capturing high-quality signals by virtue of the microelectrode’s in-plane shielding. In parkinsonian ewes, the IVI detects deep brain abnormalities and achieves stable, biocompatible in vivo recordings for four weeks. This platform enables chronic monitoring and circuit analysis of healthy and diseased deep brain regions, facilitating studies of neural circuits between periventricular surface neurons and distant brain areas.
- Open Access
- 14 October 2025
- Published by Springer Nature in Nature Communications
- Vol. 16 (1) , 1-12
Bioadhesive and conformable bioelectronic interfaces for vasomotoricity monitoring and regulation
The autonomic nervous system (ANS) dynamically regulates vasomotor function to maintain vascular homeostasis, yet current clinical tools lack the capacity to capture its electrophysiological basis, particularly following stent implantation. Herin, we report a bioadhesive and conformable bioelectronic (BACE) interface engineered for effective monitoring and modulation of vasomotoricity. Incorporating silk fibroin-based adhesives, the interface adheres robustly to cylindrical surfaces in aqueous conditions for up to two months. It exhibits low interfacial impedance (6.77 ± 2.13 kΩ at 1 kHz) and background noises (2.63 ± 0.52 μV) in vivo, enabling precise recording of varying vasomotor states. In a stent model, the interface identifies alterations in bioelectrical activity associated with vasomotor dysfunction, validated against ultrasound-derived arterial stiffness as clinical gold standards. Furthermore, we demonstrate a bidirectional system for the detection and modulation of dysfunction to restore vasomotor activity and elasticity. These findings provide insights into vasomotor electrophysiology mechanisms and underscore the therapeutic potential of bioelectronic modulation in vascular disease.
- 14 October 2025
- Published by Springer Nature in Nature Communications
- Vol. 16 (1) , 1-12
Open AccessBioadhesive and conformable bioelectronic interfaces for vasomotoricity monitoring and regulation
The autonomic nervous system (ANS) dynamically regulates vasomotor function to maintain vascular homeostasis, yet current clinical tools lack the capacity to capture its electrophysiological basis, particularly following stent implantation. Herin, we report a bioadhesive and conformable bioelectronic (BACE) interface engineered for effective monitoring and modulation of vasomotoricity. Incorporating silk fibroin-based adhesives, the interface adheres robustly to cylindrical surfaces in aqueous conditions for up to two months. It exhibits low interfacial impedance (6.77 ± 2.13 kΩ at 1 kHz) and background noises (2.63 ± 0.52 μV) in vivo, enabling precise recording of varying vasomotor states. In a stent model, the interface identifies alterations in bioelectrical activity associated with vasomotor dysfunction, validated against ultrasound-derived arterial stiffness as clinical gold standards. Furthermore, we demonstrate a bidirectional system for the detection and modulation of dysfunction to restore vasomotor activity and elasticity. These findings provide insights into vasomotor electrophysiology mechanisms and underscore the therapeutic potential of bioelectronic modulation in vascular disease.
- Open Access
- 6 September 2025
- Published by Wiley in Advanced Science
- Vol. 12 (45) , e06663
Chronically Stable, High‐Resolution Micro‐Electrocorticographic Brain‐Computer Interfaces for Real‐Time Motor Decoding
Brain‐computer interfaces (BCIs) enable communication between individuals and computers or other assistive devices by decoding brain activity, thereby reconstructing speech and motor functions for patients with neurological disorders. This study presents a high‐resolution micro‐electrocorticography (µECoG) BCI based on a flexible, high‐density µECoG electrode array, capable of chronically stable and real‐time motor decoding. Leveraging micro‐nano manufacturing technology, the µECoG BCI achieves a 64‐fold increase in electrode density compared to conventional clinical electrode arrays, enhancing spatial resolution while featuring scalability. Over a 203‐day in vivo experiment, high‐resolution µECoG carrying fine spatial specificity information demonstrated the potential to improve decoding performance while reduce implanted devices size. These advancements provide a pathway to overcome the limitations of conventional ECoG BCIs. During awake surgery, the µECoG BCI enabled game control after 7 min of model training. Furthermore, during practice of 19.87 h, the participant achieved cursor control with a bit rate of 1.13 bits per second (BPS) under full volitional control, and the bit rate reached up to 4.15 BPS with enhanced user interface. These results show that the µECoG BCI achieves comparable performance to intracortical electroencephalographic (iEEG) BCIs without intracortical invasiveness, marking a breakthrough in the clinical feasibility of flexible BCIs.
- 6 September 2025
- Published by Wiley in Advanced Science
- Vol. 12 (45) , e06663
Open AccessChronically Stable, High‐Resolution Micro‐Electrocorticographic Brain‐Computer Interfaces for Real‐Time Motor Decoding
Brain‐computer interfaces (BCIs) enable communication between individuals and computers or other assistive devices by decoding brain activity, thereby reconstructing speech and motor functions for patients with neurological disorders. This study presents a high‐resolution micro‐electrocorticography (µECoG) BCI based on a flexible, high‐density µECoG electrode array, capable of chronically stable and real‐time motor decoding. Leveraging micro‐nano manufacturing technology, the µECoG BCI achieves a 64‐fold increase in electrode density compared to conventional clinical electrode arrays, enhancing spatial resolution while featuring scalability. Over a 203‐day in vivo experiment, high‐resolution µECoG carrying fine spatial specificity information demonstrated the potential to improve decoding performance while reduce implanted devices size. These advancements provide a pathway to overcome the limitations of conventional ECoG BCIs. During awake surgery, the µECoG BCI enabled game control after 7 min of model training. Furthermore, during practice of 19.87 h, the participant achieved cursor control with a bit rate of 1.13 bits per second (BPS) under full volitional control, and the bit rate reached up to 4.15 BPS with enhanced user interface. These results show that the µECoG BCI achieves comparable performance to intracortical electroencephalographic (iEEG) BCIs without intracortical invasiveness, marking a breakthrough in the clinical feasibility of flexible BCIs.
- Open Access
- 30 May 2025
- Published by MDPI AG in Micromachines
- Vol. 16 (6) , 661
Flexible Deep-Brain Probe for High-Fidelity Multi-Scale Recording of Epileptic Network Dynamics
Epilepsy is a complex neurological disorder characterized by abnormal neural synchronization and interactions between local foci and global brain networks during seizures. Understanding seizure mechanisms across multiple scales is essential for advancing our understanding of epileptic network dynamics and guiding personalized treatment strategies. However, neural recording technologies are limited by insufficient spatial resolution, signal fidelity, and the inability to simultaneously capture network- and cellular-level dynamics. To address these limitations, we developed a high-density, flexible deep-brain probe with excellent mechanical compliance and wideband recording capabilities, enabling high-fidelity recordings of high-frequency oscillations (HFOs, 80–500 Hz) and action potentials (APs). Using a pentylenetetrazol (PTZ)-induced epilepsy model, we identified distinct spatiotemporal dynamics of HFOs and APs across epileptic stages, indicating that CA3 plays a key role in seizure onset, while CA1 is crucial for propagation. AP-HFO coupling analysis further uncovered neuronal heterogeneity, offering insights into the diverse roles of neurons in epileptic networks. This study highlights the potential of a flexible deep-brain probe for advancing epilepsy research and guiding personalized therapeutic interventions.
- 30 May 2025
- Published by MDPI AG in Micromachines
- Vol. 16 (6) , 661
Open AccessFlexible Deep-Brain Probe for High-Fidelity Multi-Scale Recording of Epileptic Network Dynamics
Epilepsy is a complex neurological disorder characterized by abnormal neural synchronization and interactions between local foci and global brain networks during seizures. Understanding seizure mechanisms across multiple scales is essential for advancing our understanding of epileptic network dynamics and guiding personalized treatment strategies. However, neural recording technologies are limited by insufficient spatial resolution, signal fidelity, and the inability to simultaneously capture network- and cellular-level dynamics. To address these limitations, we developed a high-density, flexible deep-brain probe with excellent mechanical compliance and wideband recording capabilities, enabling high-fidelity recordings of high-frequency oscillations (HFOs, 80–500 Hz) and action potentials (APs). Using a pentylenetetrazol (PTZ)-induced epilepsy model, we identified distinct spatiotemporal dynamics of HFOs and APs across epileptic stages, indicating that CA3 plays a key role in seizure onset, while CA1 is crucial for propagation. AP-HFO coupling analysis further uncovered neuronal heterogeneity, offering insights into the diverse roles of neurons in epileptic networks. This study highlights the potential of a flexible deep-brain probe for advancing epilepsy research and guiding personalized therapeutic interventions.
- Open Access
- 22 October 2024
- Published by MDPI AG in Micromachines
- Vol. 15 (11) , 1283
A Wireless Bi-Directional Brain–Computer Interface Supporting Both Bluetooth and Wi-Fi Transmission
Wireless neural signal transmission is essential for both neuroscience research and neural disorder therapies. However, conventional wireless systems are often constrained by low sampling rates, limited channel counts, and their support of only a single transmission mode. Here, we developed a wireless bi-directional brain–computer interface system featuring dual transmission modes. This system supports both low-power Bluetooth transmission and high-sampling-rate Wi-Fi transmission, providing flexibility for various application scenarios. The Bluetooth mode, with a maximum sampling rate of 14.4 kS/s, is well suited for detecting low-frequency signals, as demonstrated by both in vitro recordings of signals from 10 to 50 Hz and in vivo recordings of 16-channel local field potentials in mice. More importantly, the Wi-Fi mode, offering a maximum sampling rate of 56.8 kS/s, is optimized for recording high-frequency signals. This capability was validated through in vitro recordings of signals from 500 to 2000 Hz and in vivo recordings of single-neuron spike firings with amplitudes reaching hundreds of microvolts and high signal-to-noise ratios. Additionally, the system incorporates a wireless stimulation function capable of delivering current pulses up to 2.55 mA, with adjustable pulse width and polarity. Overall, this dual-mode system provides an efficient and flexible solution for both neural recording and stimulation applications.
- 22 October 2024
- Published by MDPI AG in Micromachines
- Vol. 15 (11) , 1283
Open AccessA Wireless Bi-Directional Brain–Computer Interface Supporting Both Bluetooth and Wi-Fi Transmission
Wireless neural signal transmission is essential for both neuroscience research and neural disorder therapies. However, conventional wireless systems are often constrained by low sampling rates, limited channel counts, and their support of only a single transmission mode. Here, we developed a wireless bi-directional brain–computer interface system featuring dual transmission modes. This system supports both low-power Bluetooth transmission and high-sampling-rate Wi-Fi transmission, providing flexibility for various application scenarios. The Bluetooth mode, with a maximum sampling rate of 14.4 kS/s, is well suited for detecting low-frequency signals, as demonstrated by both in vitro recordings of signals from 10 to 50 Hz and in vivo recordings of 16-channel local field potentials in mice. More importantly, the Wi-Fi mode, offering a maximum sampling rate of 56.8 kS/s, is optimized for recording high-frequency signals. This capability was validated through in vitro recordings of signals from 500 to 2000 Hz and in vivo recordings of single-neuron spike firings with amplitudes reaching hundreds of microvolts and high signal-to-noise ratios. Additionally, the system incorporates a wireless stimulation function capable of delivering current pulses up to 2.55 mA, with adjustable pulse width and polarity. Overall, this dual-mode system provides an efficient and flexible solution for both neural recording and stimulation applications.
- Open Access
- 17 October 2024
- Published by Springer Nature in Nature Communications
- Vol. 15 (1) , 1-10
Gustatory interface for operative assessment and taste decoding in patients with tongue cancer
Taste, a pivotal sense modality, plays a fundamental role in discerning flavors and evaluating the potential harm of food, thereby contributing to human survival, physical and mental health. Patients with tongue cancer may experience a loss of taste following extensive surgical resection with flap reconstruction. Here, we designed a gustatory interface that enables the non-invasive detection of tongue electrical activities for a comprehensive operative assessment. Moreover, it decodes gustatory information from the reconstructed tongue without taste buds. Our gustatory interface facilitates the recording and analysis of electrical activities on the tongue, yielding an electrical mapping across the entire tongue surface, which delineates the safe margin for surgical management and assesses flap viability for postoperative structure monitoring and prompt intervention. Furthermore, the gustatory interface helps patients discern tastes with an accuracy of 97.8%. Our invention offers a promising approach to clinical assessment and management and holds potential for improving the quality of life for individuals with tongue cancer.
- 17 October 2024
- Published by Springer Nature in Nature Communications
- Vol. 15 (1) , 1-10
Open AccessGustatory interface for operative assessment and taste decoding in patients with tongue cancer
Taste, a pivotal sense modality, plays a fundamental role in discerning flavors and evaluating the potential harm of food, thereby contributing to human survival, physical and mental health. Patients with tongue cancer may experience a loss of taste following extensive surgical resection with flap reconstruction. Here, we designed a gustatory interface that enables the non-invasive detection of tongue electrical activities for a comprehensive operative assessment. Moreover, it decodes gustatory information from the reconstructed tongue without taste buds. Our gustatory interface facilitates the recording and analysis of electrical activities on the tongue, yielding an electrical mapping across the entire tongue surface, which delineates the safe margin for surgical management and assesses flap viability for postoperative structure monitoring and prompt intervention. Furthermore, the gustatory interface helps patients discern tastes with an accuracy of 97.8%. Our invention offers a promising approach to clinical assessment and management and holds potential for improving the quality of life for individuals with tongue cancer.
- Open Access
- 27 March 2024
- Published by MDPI AG in Micromachines
- Vol. 15 (4) , 447
Ultraflexible PEDOT:PSS/IrOx-Modified Electrodes: Applications in Behavioral Modulation and Neural Signal Recording in Mice
Recent advancements in neural probe technology have become pivotal in both neuroscience research and the clinical management of neurological disorders. State-of-the-art developments have led to the advent of multichannel, high-density bidirectional neural interfaces that are adept at both recording and modulating neuronal activity within the central nervous system. Despite this progress, extant bidirectional probes designed for simultaneous recording and stimulation are beset with limitations, including elicitation of inflammatory responses and insufficient charge injection capacity. In this paper, we delineate the design and application of an innovative ultraflexible bidirectional neural probe engineered from polyimide. This probe is distinguished by its ability to facilitate high-resolution recordings and precise stimulation control in deep brain regions. Electrodes enhanced with a PEDOT:PSS/IrOx composite exhibit a substantial increase in charge storage capacity, escalating from 0.14 ± 0.01 mC/cm2 to an impressive 24.75 ± 0.18 mC/cm2. This augmentation significantly bolsters the electrodes’ charge transfer efficacy. In tandem, we observed a notable reduction in electrode impedance, from 3.47 ± 1.77 MΩ to a mere 41.88 ± 4.04 kΩ, while the phase angle exhibited a positive shift from −72.61 ± 1.84° to −34.17 ± 0.42°. To substantiate the electrodes’ functional prowess, we conducted in vivo experiments, where the probes were surgically implanted into the bilateral motor cortex of mice. These experiments involved the synchronous recording and meticulous analysis of neural signal fluctuations during stimulation and an assessment of the probes’ proficiency in modulating directional turning behaviors in the subjects. The empirical evidence corroborates that targeted stimulation within the bilateral motor cortex of mice can modulate the intensity of neural signals in the stimulated locale, enabling the directional control of the mice’s turning behavior to the contralateral side of the stimulation site.
- 27 March 2024
- Published by MDPI AG in Micromachines
- Vol. 15 (4) , 447
Open AccessUltraflexible PEDOT:PSS/IrOx-Modified Electrodes: Applications in Behavioral Modulation and Neural Signal Recording in Mice
Recent advancements in neural probe technology have become pivotal in both neuroscience research and the clinical management of neurological disorders. State-of-the-art developments have led to the advent of multichannel, high-density bidirectional neural interfaces that are adept at both recording and modulating neuronal activity within the central nervous system. Despite this progress, extant bidirectional probes designed for simultaneous recording and stimulation are beset with limitations, including elicitation of inflammatory responses and insufficient charge injection capacity. In this paper, we delineate the design and application of an innovative ultraflexible bidirectional neural probe engineered from polyimide. This probe is distinguished by its ability to facilitate high-resolution recordings and precise stimulation control in deep brain regions. Electrodes enhanced with a PEDOT:PSS/IrOx composite exhibit a substantial increase in charge storage capacity, escalating from 0.14 ± 0.01 mC/cm2 to an impressive 24.75 ± 0.18 mC/cm2. This augmentation significantly bolsters the electrodes’ charge transfer efficacy. In tandem, we observed a notable reduction in electrode impedance, from 3.47 ± 1.77 MΩ to a mere 41.88 ± 4.04 kΩ, while the phase angle exhibited a positive shift from −72.61 ± 1.84° to −34.17 ± 0.42°. To substantiate the electrodes’ functional prowess, we conducted in vivo experiments, where the probes were surgically implanted into the bilateral motor cortex of mice. These experiments involved the synchronous recording and meticulous analysis of neural signal fluctuations during stimulation and an assessment of the probes’ proficiency in modulating directional turning behaviors in the subjects. The empirical evidence corroborates that targeted stimulation within the bilateral motor cortex of mice can modulate the intensity of neural signals in the stimulated locale, enabling the directional control of the mice’s turning behavior to the contralateral side of the stimulation site.