Laura Carlosena
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Laura Carlosena has a total of 47 co-authors. Here are the top co-authors by number of shared publications:
Mattheos Santamouris
5 shared publicationsRupali Khatun
School of Environmental Studies, Jadavpur University, Kolkata, India
3 shared publicationsAnsar Khan
Department of Geography, Lalbaba College, University of Calcutta, Kolkata, India
2 shared publications- Ansar Khan
Department of Geography, Lalbaba College, University of Calcutta, Kolkata, India
2 shared publications Jie Feng
2 shared publications- Matthaios Santamouris
School of Built Environment, University of New South Wales, Sydney, Australia
2 shared publications
Latest Publications
- Open Access
- 19 March 2026
- Published by Elsevier in SSRN Electronic Journal
Radiative Cooling for Enhanced Geothermal Energy Storage Performance
Ground-coupled heat pumps (GCHPs) are highly efficient systems; however, in cooling-dominated operation their performance can degrade as heat accumulates in the ground, increasing entering water temperatures and borefield size requirements. Hybrid ground-coupled heat pump (HGCHP) configurations incorporating nocturnal cooling radiators (NCRs) have been proposed to mitigate this imbalance in climates with pronounced seasonal cooling demand. Nevertheless, existing solutions remain limited in their applicability to persistently hot climates, where year-round cooling loads prevent effective thermal recovery. In this context, we propose a cement-based continuous cooling radiator (CCR) fabricated from daytime radiative-cooling concrete and integrated into an HGCHP loop. A transient computational model was developed to evaluate system performance and long-term techno-economic viability. Performance was assessed across three representative climates: Hong Kong (highly seasonal cooling), Phoenix (high radiative-cooling potential), and Singapore (year-round cooling demand). System sizing was constrained by a temperature cap (EWT ≤ 40 °C over 10 years) and evaluated within a 10-year life-cycle cost (LCC) framework. Despite the strong climatic contrasts, CCR integration substantially reduces required borefield length (58–81% relative to a baseline GCHP) and delivers the lowest 10-year cost in all climates (23–42% reduction). Under a constrained roof area (105 m²), operational CO₂ reductions are modest; however, a near-full-roof sensitivity case (240 m²) yields clear electricity and emissions savings (up to ~11%). A screening comparison with conventional HVAC (fixed COP = 3) indicates a cumulative cost crossover within the first year for the CCR-based hybrid system in all three climates. These findings demonstrate that low-cost, cement-based continuous radiators can meaningfully reduce drilling-driven capital expenditure barriers and support both new-build and retrofit deployment of hybrid GCHP systems in cooling-dominated cities.
- 19 March 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessRadiative Cooling for Enhanced Geothermal Energy Storage Performance
Ground-coupled heat pumps (GCHPs) are highly efficient systems; however, in cooling-dominated operation their performance can degrade as heat accumulates in the ground, increasing entering water temperatures and borefield size requirements. Hybrid ground-coupled heat pump (HGCHP) configurations incorporating nocturnal cooling radiators (NCRs) have been proposed to mitigate this imbalance in climates with pronounced seasonal cooling demand. Nevertheless, existing solutions remain limited in their applicability to persistently hot climates, where year-round cooling loads prevent effective thermal recovery. In this context, we propose a cement-based continuous cooling radiator (CCR) fabricated from daytime radiative-cooling concrete and integrated into an HGCHP loop. A transient computational model was developed to evaluate system performance and long-term techno-economic viability. Performance was assessed across three representative climates: Hong Kong (highly seasonal cooling), Phoenix (high radiative-cooling potential), and Singapore (year-round cooling demand). System sizing was constrained by a temperature cap (EWT ≤ 40 °C over 10 years) and evaluated within a 10-year life-cycle cost (LCC) framework. Despite the strong climatic contrasts, CCR integration substantially reduces required borefield length (58–81% relative to a baseline GCHP) and delivers the lowest 10-year cost in all climates (23–42% reduction). Under a constrained roof area (105 m²), operational CO₂ reductions are modest; however, a near-full-roof sensitivity case (240 m²) yields clear electricity and emissions savings (up to ~11%). A screening comparison with conventional HVAC (fixed COP = 3) indicates a cumulative cost crossover within the first year for the CCR-based hybrid system in all three climates. These findings demonstrate that low-cost, cement-based continuous radiators can meaningfully reduce drilling-driven capital expenditure barriers and support both new-build and retrofit deployment of hybrid GCHP systems in cooling-dominated cities.
- Open Access
- 11 January 2025
- Published by Elsevier in Applied Thermal Engineering
- Vol. 265
Towards cooling concrete: Evaluation of cement and cement composites under realistic climatic conditions
- 11 January 2025
- Published by Elsevier in Applied Thermal Engineering
- Vol. 265
Open AccessTowards cooling concrete: Evaluation of cement and cement composites under realistic climatic conditions
- Open Access
- 9 August 2024
- Published by Elsevier in Solar Energy Materials and Solar Cells
- Vol. 277
Harnessing the potential of radiative cooling for the built environment: A new comprehensive protocol for materials’ characterization
- 9 August 2024
- Published by Elsevier in Solar Energy Materials and Solar Cells
- Vol. 277
Open AccessHarnessing the potential of radiative cooling for the built environment: A new comprehensive protocol for materials’ characterization
- Open Access
- 5 August 2023
- Published by Elsevier in Building and Environment
- Vol. 243
Worldwide potential of emissive materials based radiative cooling technologies to mitigate urban overheating
- 5 August 2023
- Published by Elsevier in Building and Environment
- Vol. 243
Open AccessWorldwide potential of emissive materials based radiative cooling technologies to mitigate urban overheating
- Open Access
- 4 August 2023
- Published by Springer Nature in Computational Urban Science
- Vol. 3 (1) , 1-31
Urban cooling potential and cost comparison of heat mitigation techniques for their impact on the lower atmosphere
Cool materials and rooftop vegetation help achieve urban heating mitigation as they can reduce building cooling demands. This study assesses the cooling potential of different mitigation technologies using Weather Research and Forecasting (WRF)- taking case of a tropical coastal climate in the Kolkata Metropolitan Area. The model was validated using data from six meteorological sites. The cooling potential of eight mitigation scenarios was evaluated for: three cool roofs, four green roofs, and their combination (cool-city). The sensible heat, latent heat, heat storage, 2-m ambient temperature, surface temperature, air temperature, roof temperature, and urban canopy temperature was calculated. The effects on the urban boundary layer were also investigated.The different scenarios reduced the daytime temperature of various urban components, and the effect varied nearly linearly with increasing albedo and green roof fractions. For example, the maximum ambient temperature decreased by 3.6 °C, 0.9 °C, and 1.4 °C for a cool roof with 85% albedo, 100% rooftop vegetation, and their combination.The cost of different mitigation scenarios was assumed to depend on the construction options, location, and market prices. The potential for price per square meter and corresponding temperature decreased was related to one another. Recognizing the complex relationship between scenarios and construction options, the reduction in the maximum and minimum temperature across different cool and green roof cases were used for developing the cost estimates. This estimate thus attempted a summary of the price per degree of cooling for the different potential technologies.Higher green fraction, cool materials, and their combination generally reduced winds and enhanced buoyancy. The surface changes alter the lower atmospheric dynamics such as low-level vertical mixing and a shallower boundary layer and weakened horizontal convective rolls during afternoon hours. Although cool materials offer the highest temperature reductions, the cooling resulting from its combination and a green roof strategy could mitigate or reverse the summertime heat island effect. The results highlight the possibilities for heat mitigation and offer insight into the different strategies and costs for mitigating the urban heating and cooling demands.
- 4 August 2023
- Published by Springer Nature in Computational Urban Science
- Vol. 3 (1) , 1-31
Open AccessUrban cooling potential and cost comparison of heat mitigation techniques for their impact on the lower atmosphere
Cool materials and rooftop vegetation help achieve urban heating mitigation as they can reduce building cooling demands. This study assesses the cooling potential of different mitigation technologies using Weather Research and Forecasting (WRF)- taking case of a tropical coastal climate in the Kolkata Metropolitan Area. The model was validated using data from six meteorological sites. The cooling potential of eight mitigation scenarios was evaluated for: three cool roofs, four green roofs, and their combination (cool-city). The sensible heat, latent heat, heat storage, 2-m ambient temperature, surface temperature, air temperature, roof temperature, and urban canopy temperature was calculated. The effects on the urban boundary layer were also investigated.The different scenarios reduced the daytime temperature of various urban components, and the effect varied nearly linearly with increasing albedo and green roof fractions. For example, the maximum ambient temperature decreased by 3.6 °C, 0.9 °C, and 1.4 °C for a cool roof with 85% albedo, 100% rooftop vegetation, and their combination.The cost of different mitigation scenarios was assumed to depend on the construction options, location, and market prices. The potential for price per square meter and corresponding temperature decreased was related to one another. Recognizing the complex relationship between scenarios and construction options, the reduction in the maximum and minimum temperature across different cool and green roof cases were used for developing the cost estimates. This estimate thus attempted a summary of the price per degree of cooling for the different potential technologies.Higher green fraction, cool materials, and their combination generally reduced winds and enhanced buoyancy. The surface changes alter the lower atmospheric dynamics such as low-level vertical mixing and a shallower boundary layer and weakened horizontal convective rolls during afternoon hours. Although cool materials offer the highest temperature reductions, the cooling resulting from its combination and a green roof strategy could mitigate or reverse the summertime heat island effect. The results highlight the possibilities for heat mitigation and offer insight into the different strategies and costs for mitigating the urban heating and cooling demands.
- Open Access
- 15 April 2023
- Published by American Geophysical Union (AGU) in Journal of Geophysical Research: Atmospheres
- Vol. 128 (8)
Exploring the Meteorological Impacts of Surface and Rooftop Heat Mitigation Strategies Over a Tropical City
Different heat mitigation technologies have been developed to improve the thermal environment in cities. However, the regional impacts of such technologies, especially in the context of a tropical city, remain unclear. The deployment of heat mitigation technologies at city‐scale can change the radiation balance, advective flow, and energy balance between urban areas and the overlying atmosphere. We used the mesoscale Weather Research and Forecasting model coupled with a physically based single‐layer urban canopy model to assess the impacts of five different heat mitigation technologies on surface energy balance, standard surface meteorological fields, and planetary boundary layer (PBL) dynamics for premonsoon typical hot summer days over a tropical coastal city in the month of April in 2018, 2019, and 2020. Results indicate that the regional impacts of cool materials (CMs), super‐cool broadband radiative coolers, green roofs (GRs), vegetation fraction change, and a combination of CMs and GRs (i.e., “Cool city (CC)”) on the lower atmosphere are different at diurnal scale. Results showed that super‐cool materials have the maximum potential of ambient temperature reduction of 1.6°C during peak hour (14:00 LT) compared to other technologies in the study. During the daytime hours, the PBL height was considerably lower than the reference scenario with no implementation of strategies by 700 m for super‐cool materials and 500 m for both CMs and CC cases; however, the green roofing system underwent nominal changes over the urban area. During the nighttime hours, the PBL height increased by CMs and the CC strategies compared to the reference scenario, but minimal changes were evident for super‐cool materials. The changes of temperature on the vertical profile of the heat mitigation implemented city reveal a stable PBL over the urban domain and a reduction of the vertical mixing associated with a pollution dome. This would lead to crossover phenomena above the PBL due to the decrease in vertical wind speed. Therefore, assessing the coupled regional impact of urban heat mitigation over the lower atmosphere at city‐scale is urgent for sustainable urban planning.
- 15 April 2023
- Published by American Geophysical Union (AGU) in Journal of Geophysical Research: Atmospheres
- Vol. 128 (8)
Open AccessExploring the Meteorological Impacts of Surface and Rooftop Heat Mitigation Strategies Over a Tropical City
Different heat mitigation technologies have been developed to improve the thermal environment in cities. However, the regional impacts of such technologies, especially in the context of a tropical city, remain unclear. The deployment of heat mitigation technologies at city‐scale can change the radiation balance, advective flow, and energy balance between urban areas and the overlying atmosphere. We used the mesoscale Weather Research and Forecasting model coupled with a physically based single‐layer urban canopy model to assess the impacts of five different heat mitigation technologies on surface energy balance, standard surface meteorological fields, and planetary boundary layer (PBL) dynamics for premonsoon typical hot summer days over a tropical coastal city in the month of April in 2018, 2019, and 2020. Results indicate that the regional impacts of cool materials (CMs), super‐cool broadband radiative coolers, green roofs (GRs), vegetation fraction change, and a combination of CMs and GRs (i.e., “Cool city (CC)”) on the lower atmosphere are different at diurnal scale. Results showed that super‐cool materials have the maximum potential of ambient temperature reduction of 1.6°C during peak hour (14:00 LT) compared to other technologies in the study. During the daytime hours, the PBL height was considerably lower than the reference scenario with no implementation of strategies by 700 m for super‐cool materials and 500 m for both CMs and CC cases; however, the green roofing system underwent nominal changes over the urban area. During the nighttime hours, the PBL height increased by CMs and the CC strategies compared to the reference scenario, but minimal changes were evident for super‐cool materials. The changes of temperature on the vertical profile of the heat mitigation implemented city reveal a stable PBL over the urban domain and a reduction of the vertical mixing associated with a pollution dome. This would lead to crossover phenomena above the PBL due to the decrease in vertical wind speed. Therefore, assessing the coupled regional impact of urban heat mitigation over the lower atmosphere at city‐scale is urgent for sustainable urban planning.
- 6 October 2022
- Published by Springer Nature
- p. 321-341
The Trend of Heat-Related Mortality in Spain
- Open Access
- 19 January 2022
- Published by MDPI AG in Sustainability
- Vol. 14 (3) , 1110
Optically Modulated Passive Broadband Daytime Radiative Cooling Materials Can Cool Cities in Summer and Heat Cities in Winter
Broadband passive daytime radiative cooling (PDRC) materials exhibit sub-ambient surface temperatures and contribute highly to mitigating extreme urban heat during the warm period. However, their application may cause undesired overcooling problems in winter. This study aims to assess, on a city scale, different solutions to overcome the winter overcooling penalty derived from using PDRC materials. Furthermore, a mesoscale urban modeling system assesses the potential of the optical modulation of reflectance (ρ) and emissivity (ε) to reduce, minimize, or reverse the overcooling penalty. The alteration of heat flux components, air temperature modification, ground and roof surface temperature, and the urban canopy temperature are assessed. The maximum decrease of the winter ambient temperature using standard PDRC materials is 1.1 °C and 0.8 °C for daytime and nighttime, respectively, while the ρ+ε-modulation can increase the ambient temperature up to 0.4 °C and 1.4 °C, respectively, compared to the use of conventional materials. Compared with the control case, the maximum decrease of net radiation inflow occurred at the peak hour, reducing by 192.7 Wm−2 for the PDRC materials, 5.4 Wm−2 for ρ-modulated PDRC materials, and 173.7 Wm−2 for ε-PDRC materials; nevertheless, the ρ+ε-modulated PDRC materials increased the maximum net radiation inflow by 51.5 Wm−2, leading to heating of the cities during the winter.
- 19 January 2022
- Published by MDPI AG in Sustainability
- Vol. 14 (3) , 1110
Open AccessOptically Modulated Passive Broadband Daytime Radiative Cooling Materials Can Cool Cities in Summer and Heat Cities in Winter
Broadband passive daytime radiative cooling (PDRC) materials exhibit sub-ambient surface temperatures and contribute highly to mitigating extreme urban heat during the warm period. However, their application may cause undesired overcooling problems in winter. This study aims to assess, on a city scale, different solutions to overcome the winter overcooling penalty derived from using PDRC materials. Furthermore, a mesoscale urban modeling system assesses the potential of the optical modulation of reflectance (ρ) and emissivity (ε) to reduce, minimize, or reverse the overcooling penalty. The alteration of heat flux components, air temperature modification, ground and roof surface temperature, and the urban canopy temperature are assessed. The maximum decrease of the winter ambient temperature using standard PDRC materials is 1.1 °C and 0.8 °C for daytime and nighttime, respectively, while the ρ+ε-modulation can increase the ambient temperature up to 0.4 °C and 1.4 °C, respectively, compared to the use of conventional materials. Compared with the control case, the maximum decrease of net radiation inflow occurred at the peak hour, reducing by 192.7 Wm−2 for the PDRC materials, 5.4 Wm−2 for ρ-modulated PDRC materials, and 173.7 Wm−2 for ε-PDRC materials; nevertheless, the ρ+ε-modulated PDRC materials increased the maximum net radiation inflow by 51.5 Wm−2, leading to heating of the cities during the winter.
- Open Access
- 1 September 2021
- Published by Elsevier in Solar Energy Materials and Solar Cells
- Vol. 230
Experimental development and testing of low-cost scalable radiative cooling materials for building applications
- 1 September 2021
- Published by Elsevier in Solar Energy Materials and Solar Cells
- Vol. 230
Open AccessExperimental development and testing of low-cost scalable radiative cooling materials for building applications
- Open Access
- 1 January 2021
- Published by Elsevier in Solar Energy Advances
- Vol. 1
On the winter overcooling penalty of super cool photonic materials in cities
- 1 January 2021
- Published by Elsevier in Solar Energy Advances
- Vol. 1
Open AccessOn the winter overcooling penalty of super cool photonic materials in cities