Abdalla M. Omar
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Abdalla M. Omar has a total of 55 co-authors. Here are the top co-authors by number of shared publications:
- Paulo Bartolo
Singapore Centre for 3D Printing, Nanyang Technological University, Singapore, Singapore
11 shared publications - Mohamed Hassan
University of Manchester
9 shared publications - Evangelos Daskalakis
School of Mechanical, Aerospace and Civil Engineering, University of Manchester, Manchester M13 9PL, UK
7 shared publications - Bruce Grieve
Department of Electrical and Electronic Engineering, The University of Manchester, Manchester, U.K.
3 shared publications - Glen Cooper
University of Manchester
2 shared publications - Wajira Mirihanage
The University of Manchester, Manchester, UK
2 shared publications
Latest Publications
- Open Access
- 15 October 2026
- Published by Elsevier in Composites Part C: Open Access
- Vol. 21
Additively manufactured conductive heating elements for Joule welding of LMPAEK and its fibre-reinforced composites
- 15 October 2026
- Published by Elsevier in Composites Part C: Open Access
- Vol. 21
Open AccessAdditively manufactured conductive heating elements for Joule welding of LMPAEK and its fibre-reinforced composites
- Open Access
- 8 October 2026
- Published by Elsevier in SSRN Electronic Journal
Suppressing Oozing during Filament-Based Melt Electrowriting
Melt electrowriting (MEW) is an additive manufacturing technique capable of producing highly ordered microscale fibres with precise spatial control. In filament-based MEW systems, however, unintended melt extrusion, which is technically termed ‘oozing’, can occur before or during printing because continuous filament feeding generates internal nozzle pressure. At the same time, low-viscosity molten polymer readily flows at typical processing temperatures. This study investigated oozing in a polycaprolactone (PCL)-based MEW system and evaluated two practical mitigation strategies: (i) cleaning the nozzle by a Polylactic Acid (PLA) filament followed by loading fresh PCL filament, and (ii) active cooling of the filament above the heater block to suppress premature melting. Both strategies prevented oozing in ten repeated trials while providing a stable Taylor cone and continuous jet formation, which was evidenced by the measured fibre diameter along the printing path. The recommended methods improve process stability, print quality and reproducibility in any filament-based MEW system.
- 8 October 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessSuppressing Oozing during Filament-Based Melt Electrowriting
Melt electrowriting (MEW) is an additive manufacturing technique capable of producing highly ordered microscale fibres with precise spatial control. In filament-based MEW systems, however, unintended melt extrusion, which is technically termed ‘oozing’, can occur before or during printing because continuous filament feeding generates internal nozzle pressure. At the same time, low-viscosity molten polymer readily flows at typical processing temperatures. This study investigated oozing in a polycaprolactone (PCL)-based MEW system and evaluated two practical mitigation strategies: (i) cleaning the nozzle by a Polylactic Acid (PLA) filament followed by loading fresh PCL filament, and (ii) active cooling of the filament above the heater block to suppress premature melting. Both strategies prevented oozing in ten repeated trials while providing a stable Taylor cone and continuous jet formation, which was evidenced by the measured fibre diameter along the printing path. The recommended methods improve process stability, print quality and reproducibility in any filament-based MEW system.
- Open Access
- 15 June 2025
- Published by Elsevier in Materials Letters
- Vol. 398
Drapeable and elastic 3D printed Polylactic Acid (PLA) textiles
- 15 June 2025
- Published by Elsevier in Materials Letters
- Vol. 398
Open AccessDrapeable and elastic 3D printed Polylactic Acid (PLA) textiles
- Open Access
- 11 December 2024
- Published by Elsevier in Journal of Cleaner Production
- Vol. 486
Demonstrating a biobased concept for the production of sustainable bacterial cellulose from mixed textile, agricultural and municipal wastes
- 11 December 2024
- Published by Elsevier in Journal of Cleaner Production
- Vol. 486
Open AccessDemonstrating a biobased concept for the production of sustainable bacterial cellulose from mixed textile, agricultural and municipal wastes
- Open Access
- 21 June 2023
- Published by AccScience Publishing in International Journal of Bioprinting
- Vol. 9 (6) , 0024-10
Electrospinning polyethylene terephthalate glycol
AccScience Publishing is a publishing company based in Singapore. We have in our portfolio a range of high-quality, open-access, peer-reviewed journals and books from a broad spectrum of science, technology, biomedicine, engineering, education, social sciences and many more.
- 21 June 2023
- Published by AccScience Publishing in International Journal of Bioprinting
- Vol. 9 (6) , 0024-10
Open AccessElectrospinning polyethylene terephthalate glycol
AccScience Publishing is a publishing company based in Singapore. We have in our portfolio a range of high-quality, open-access, peer-reviewed journals and books from a broad spectrum of science, technology, biomedicine, engineering, education, social sciences and many more.
- 15 June 2023
- Published by Springer Nature
- p. 399-405
Morphological Investigation of Electrospun PVDF (HFP)-Carbon Black Nanocomposites
- 15 June 2023
- Published by Springer Nature
- p. 399-405
Morphological Investigation of Electrospun PVDF (HFP)-Carbon Black Nanocomposites
- Open Access
Accelerated Degradation of Poly-ε-caprolactone Composite Scaffolds for Large Bone Defects
This research investigates the accelerated hydrolytic degradation process of both anatomically designed bone scaffolds with a pore size gradient and a rectangular shape (biomimetically designed scaffolds or bone bricks). The effect of material composition is investigated considering poly-ε-caprolactone (PCL) as the main scaffold material, reinforced with ceramics such as hydroxyapatite (HA), β-tricalcium phosphate (TCP) and bioglass at a concentration of 20 wt%. In the case of rectangular scaffolds, the effect of pore size (200 μm, 300 μm and 500 μm) is also investigated. The degradation process (accelerated degradation) was investigated during a period of 5 days in a sodium hydroxide (NaOH) medium. Degraded bone bricks and rectangular scaffolds were measured each day to evaluate the weight loss of the samples, which were also morphologically, thermally, chemically and mechanically assessed. The results show that the PCL/bioglass bone brick scaffolds exhibited faster degradation kinetics in comparison with the PCL, PCL/HA and PCL/TCP bone bricks. Furthermore, the degradation kinetics of rectangular scaffolds increased by increasing the pore size from 500 μm to 200 μm. The results also indicate that, for the same material composition, bone bricks degrade slower compared with rectangular scaffolds. The scanning electron microscopy (SEM) images show that the degradation process was faster on the external regions of the bone brick scaffolds (600 μm pore size) compared with the internal regions (200 μm pore size). The thermal gravimetric analysis (TGA) results show that the ceramic concentration remained constant throughout the degradation process, while differential scanning calorimetry (DSC) results show that all scaffolds exhibited a reduction in crystallinity (Xc), enthalpy (Δm) and melting temperature (Tm) throughout the degradation process, while the glass transition temperature (Tg) slightly increased. Finally, the compression results show that the mechanical properties decreased during the degradation process, with PCL/bioglass bone bricks and rectangular scaffolds presenting higher mechanical properties with the same design in comparison with the other materials.
Open AccessAccelerated Degradation of Poly-ε-caprolactone Composite Scaffolds for Large Bone Defects
This research investigates the accelerated hydrolytic degradation process of both anatomically designed bone scaffolds with a pore size gradient and a rectangular shape (biomimetically designed scaffolds or bone bricks). The effect of material composition is investigated considering poly-ε-caprolactone (PCL) as the main scaffold material, reinforced with ceramics such as hydroxyapatite (HA), β-tricalcium phosphate (TCP) and bioglass at a concentration of 20 wt%. In the case of rectangular scaffolds, the effect of pore size (200 μm, 300 μm and 500 μm) is also investigated. The degradation process (accelerated degradation) was investigated during a period of 5 days in a sodium hydroxide (NaOH) medium. Degraded bone bricks and rectangular scaffolds were measured each day to evaluate the weight loss of the samples, which were also morphologically, thermally, chemically and mechanically assessed. The results show that the PCL/bioglass bone brick scaffolds exhibited faster degradation kinetics in comparison with the PCL, PCL/HA and PCL/TCP bone bricks. Furthermore, the degradation kinetics of rectangular scaffolds increased by increasing the pore size from 500 μm to 200 μm. The results also indicate that, for the same material composition, bone bricks degrade slower compared with rectangular scaffolds. The scanning electron microscopy (SEM) images show that the degradation process was faster on the external regions of the bone brick scaffolds (600 μm pore size) compared with the internal regions (200 μm pore size). The thermal gravimetric analysis (TGA) results show that the ceramic concentration remained constant throughout the degradation process, while differential scanning calorimetry (DSC) results show that all scaffolds exhibited a reduction in crystallinity (Xc), enthalpy (Δm) and melting temperature (Tm) throughout the degradation process, while the glass transition temperature (Tg) slightly increased. Finally, the compression results show that the mechanical properties decreased during the degradation process, with PCL/bioglass bone bricks and rectangular scaffolds presenting higher mechanical properties with the same design in comparison with the other materials.
- Open Access
- 6 October 2022
- Published by MDPI AG in Biosensors
- Vol. 12 (10) , 829
Multi-Layer Biosensor for Pre-Symptomatic Detection of Puccinia strifformis, the Causal Agent of Yellow Rust
The yellow rust of wheat (caused by Puccinia striiformis f. sp. tritici) is a devastating fungal infection that is responsible for significant wheat yield losses. The main challenge with the detection of this disease is that it can only be visually detected on the leaf surface between 7 and 10 days after infection, and by this point, counter measures such as the use of fungicides are generally less effective. The hypothesis of this study is to develop and use a compact electrochemical-based biosensor for the early detection of P. striiformis, thus enabling fast countermeasures to be taken. The biosensor that was developed consists of three layers. The first layer mimics the wheat leaf surface morphology. The second layer consists of a sucrose/agar mixture that acts as a substrate and contains a wheat-derived terpene volatile organic compound that stimulates the germination and growth of the spores of the yellow rust pathogen P. s. f. sp. tritici. The third layer consists of a nonenzymatic glucose sensor that produces a signal once invertase is produced by P. striiformis, which comes into contact with the second layer, thereby converting sucrose to glucose. The results show the proof that this innovative biosensor can enable the detection of yellow rust spores in 72 h.
- 6 October 2022
- Published by MDPI AG in Biosensors
- Vol. 12 (10) , 829
Open AccessMulti-Layer Biosensor for Pre-Symptomatic Detection of Puccinia strifformis, the Causal Agent of Yellow Rust
The yellow rust of wheat (caused by Puccinia striiformis f. sp. tritici) is a devastating fungal infection that is responsible for significant wheat yield losses. The main challenge with the detection of this disease is that it can only be visually detected on the leaf surface between 7 and 10 days after infection, and by this point, counter measures such as the use of fungicides are generally less effective. The hypothesis of this study is to develop and use a compact electrochemical-based biosensor for the early detection of P. striiformis, thus enabling fast countermeasures to be taken. The biosensor that was developed consists of three layers. The first layer mimics the wheat leaf surface morphology. The second layer consists of a sucrose/agar mixture that acts as a substrate and contains a wheat-derived terpene volatile organic compound that stimulates the germination and growth of the spores of the yellow rust pathogen P. s. f. sp. tritici. The third layer consists of a nonenzymatic glucose sensor that produces a signal once invertase is produced by P. striiformis, which comes into contact with the second layer, thereby converting sucrose to glucose. The results show the proof that this innovative biosensor can enable the detection of yellow rust spores in 72 h.
- Open Access
- 27 July 2022
- Published by MDPI AG in Journal of Functional Biomaterials
- Vol. 13 (3) , 104
Geometry-Based Computational Fluid Dynamic Model for Predicting the Biological Behavior of Bone Tissue Engineering Scaffolds
The use of biocompatible and biodegradable porous scaffolds produced via additive manufacturing is one of the most common approaches in tissue engineering. The geometric design of tissue engineering scaffolds (e.g., pore size, pore shape, and pore distribution) has a significant impact on their biological behavior. Fluid flow dynamics are important for understanding blood flow through a porous structure, as they determine the transport of nutrients and oxygen to cells and the flushing of toxic waste. The aim of this study is to investigate the impact of the scaffold architecture, pore size and distribution on its biological performance using Computational Fluid Dynamics (CFD). Different blood flow velocities (BFV) induce wall shear stresses (WSS) on cells. WSS values above 30 mPa are detrimental to their growth. In this study, two scaffold designs were considered: rectangular scaffolds with uniform square pores (300, 350, and 450 µm), and anatomically designed circular scaffolds with a bone-like structure and pore size gradient (476–979 µm). The anatomically designed scaffolds provided the best fluid flow conditions, suggesting a 24.21% improvement in the biological performance compared to the rectangular scaffolds. The numerical observations are aligned with those of previously reported biological studies.
- 27 July 2022
- Published by MDPI AG in Journal of Functional Biomaterials
- Vol. 13 (3) , 104
Open AccessGeometry-Based Computational Fluid Dynamic Model for Predicting the Biological Behavior of Bone Tissue Engineering Scaffolds
The use of biocompatible and biodegradable porous scaffolds produced via additive manufacturing is one of the most common approaches in tissue engineering. The geometric design of tissue engineering scaffolds (e.g., pore size, pore shape, and pore distribution) has a significant impact on their biological behavior. Fluid flow dynamics are important for understanding blood flow through a porous structure, as they determine the transport of nutrients and oxygen to cells and the flushing of toxic waste. The aim of this study is to investigate the impact of the scaffold architecture, pore size and distribution on its biological performance using Computational Fluid Dynamics (CFD). Different blood flow velocities (BFV) induce wall shear stresses (WSS) on cells. WSS values above 30 mPa are detrimental to their growth. In this study, two scaffold designs were considered: rectangular scaffolds with uniform square pores (300, 350, and 450 µm), and anatomically designed circular scaffolds with a bone-like structure and pore size gradient (476–979 µm). The anatomically designed scaffolds provided the best fluid flow conditions, suggesting a 24.21% improvement in the biological performance compared to the rectangular scaffolds. The numerical observations are aligned with those of previously reported biological studies.
- Open Access
Experimental and Numerical Simulations of 3D-Printed Polycaprolactone Scaffolds for Bone Tissue Engineering Applications
Ideal bone scaffolds for tissue engineering should be highly porous allowing cell attachment, spreading, and differentiation and presenting appropriate biomechanical properties. These antagonistic characteristics usually require extensive experimental work to achieve optimised balanced properties. This paper presents a simulation approach to determine the mechanical behaviour of bone scaffolds allowing the compressive modulus and the deformation mechanisms to be predicted. Polycaprolactone scaffolds with regular square pores and different porosities were considered. Scaffolds were also printed using an extrusion-based additive manufacturing and assessed under compressive loads. Similar designs were used for both simulation and fabrication steps. A good correlation between numerical and experimental results was obtained, highlighting the suitability of the simulation tool for the mechanical design of 3D-printed bone scaffolds.
Open AccessExperimental and Numerical Simulations of 3D-Printed Polycaprolactone Scaffolds for Bone Tissue Engineering Applications
Ideal bone scaffolds for tissue engineering should be highly porous allowing cell attachment, spreading, and differentiation and presenting appropriate biomechanical properties. These antagonistic characteristics usually require extensive experimental work to achieve optimised balanced properties. This paper presents a simulation approach to determine the mechanical behaviour of bone scaffolds allowing the compressive modulus and the deformation mechanisms to be predicted. Polycaprolactone scaffolds with regular square pores and different porosities were considered. Scaffolds were also printed using an extrusion-based additive manufacturing and assessed under compressive loads. Similar designs were used for both simulation and fabrication steps. A good correlation between numerical and experimental results was obtained, highlighting the suitability of the simulation tool for the mechanical design of 3D-printed bone scaffolds.