Yiftach Barash
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Yiftach Barash has a total of 107 co-authors. Here are the top co-authors by number of shared publications:
- Eyal Klang
BRIDGE GenAI Lab, Beth Israel Deaconess Medical Center, Boston, MA, USA
32 shared publications - Alon Gorenshtein
Beth Israel Deaconess Medical Center
22 shared publications - Mahmud Omar
BRIDGE GenAI Lab, Beth Israel Deaconess Medical Center, Boston, MA, USA
19 shared publications - Yosef Adiniaev
BRIDGE GenAI Lab, Beth Israel Deaconess Medical Center, Boston, MA, USA
14 shared publications - Olga Rachel Brook
Department of Radiology, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, MA, USA
13 shared publications - Oved Daniel
Neurology Division, Tel Aviv Sourasky University Medical Center, Tel Aviv, Israel
10 shared publications
Latest Publications
- 1 February 2027
- Published by Wolters Kluwer Health in Neurology Clinical Practice
- Vol. 17 (1)
Large Language Models in Clinical Neurology
- 1 February 2027
- Published by Wolters Kluwer Health in Neurology Clinical Practice
- Vol. 17 (1)
Large Language Models in Clinical Neurology
- Open Access
False-Positive Calls of Reimplemented Published Analyses for Covert Command-Following on Electroencephalograms Recorded Without Study Commands
Objective: To measure how often published electroencephalographic analyses for covert command-following call patients positive without commands, and their detection of genuine responses. Methods: This cross-sectional study applied 11 reimplemented published analyses to electroencephalograms without commands: 974 clinical electroencephalography patients and, with rules fixed, 730 new patients; 38 with prolonged disorders of consciousness; and 544 comatose patients after cardiac arrest. Outcomes: false calls (share called positive) against a 5% benchmark, and genuine-response detection. Results: Three of 10 command-following analyses called significantly more than 5% of clinical electroencephalography patients positive, replicated in new patients: Goldfine 2011, a spectral test, 23.3% (95% CI, 20.2%-26.6%), above its stated 5%; du Bois 2026, a criterion for entry to brain-computer interface training, 22.2% (95% CI, 19.2%-25.5%); and Guger 2018, a P300 accuracy threshold, 13.8% (95% CI, 11.5%-16.3%), near its approximate 12% chance rate (24.5% over 2 runs). The other 7 called 0.0% to 6.9%. After cardiac arrest: 11.5% to 27.3%. All 3 detected genuine responses. Identified contributors: a variance ignoring within-command dependence (Goldfine 2011), selection over configurations and times (du Bois 2026) and a permissive threshold (Guger 2018). Goldfine 2011’s command-level correction, fixed before testing, called 0.8% of new patients and 2.4% after arrest, detecting 93.4% of stroke imagery-versus-rest sessions but few between imagery types. Interpretation: Reimplemented published analyses called up to 27% of patients positive without commands, more with repeated runs. A positive result needs its complete call rule’s false-call rate and detection at that rate; imagery-versus-rest detection may reflect task engagement, not imagery.
Open AccessFalse-Positive Calls of Reimplemented Published Analyses for Covert Command-Following on Electroencephalograms Recorded Without Study Commands
Objective: To measure how often published electroencephalographic analyses for covert command-following call patients positive without commands, and their detection of genuine responses. Methods: This cross-sectional study applied 11 reimplemented published analyses to electroencephalograms without commands: 974 clinical electroencephalography patients and, with rules fixed, 730 new patients; 38 with prolonged disorders of consciousness; and 544 comatose patients after cardiac arrest. Outcomes: false calls (share called positive) against a 5% benchmark, and genuine-response detection. Results: Three of 10 command-following analyses called significantly more than 5% of clinical electroencephalography patients positive, replicated in new patients: Goldfine 2011, a spectral test, 23.3% (95% CI, 20.2%-26.6%), above its stated 5%; du Bois 2026, a criterion for entry to brain-computer interface training, 22.2% (95% CI, 19.2%-25.5%); and Guger 2018, a P300 accuracy threshold, 13.8% (95% CI, 11.5%-16.3%), near its approximate 12% chance rate (24.5% over 2 runs). The other 7 called 0.0% to 6.9%. After cardiac arrest: 11.5% to 27.3%. All 3 detected genuine responses. Identified contributors: a variance ignoring within-command dependence (Goldfine 2011), selection over configurations and times (du Bois 2026) and a permissive threshold (Guger 2018). Goldfine 2011’s command-level correction, fixed before testing, called 0.8% of new patients and 2.4% after arrest, detecting 93.4% of stroke imagery-versus-rest sessions but few between imagery types. Interpretation: Reimplemented published analyses called up to 27% of patients positive without commands, more with repeated runs. A positive result needs its complete call rule’s false-call rate and detection at that rate; imagery-versus-rest detection may reflect task engagement, not imagery.
- 11 October 2026
- Published by SAGE Publications in Vascular and Endovascular Surgery
Retrograde Tibialis Anterior Artery Access as an Alternative Route for Stent-Based Endovascular Repair of Femoral Access-Site Complications
Background: Femoral arterial access can lead to complications, including bleeding, pseudoaneurysms, arteriovenous fistulas (AVFs), and dissections. When utilizing endovascular methods, the treatment of these complications is typically performed via contralateral femoral access. For appropriate patients, the tibialis anterior (TA) approach offers a promising alternative, providing distal access with minimal risk of complications. This study evaluates the single retrograde TA approach for managing femoral artery access complications. Patients and Methods: A single-center retrospective analysis was conducted, including 11 patients who underwent endovascular treatment for femoral access complications via a single ipsilateral TA approach. Baseline demographics, procedural characteristics, and outcomes were collected from hospital records. Technical success was defined as the ability to obtain retrograde tibialis anterior access, advance a catheter to the target site, and deliver the intended therapy. Procedural success was defined as effective treatment of the vascular injury with preservation of patency in both the treated vessel and the tibialis anterior artery used for access. Results: Eleven patients (median age, 73 years; 55% male) underwent stent-based endovascular treatment. The most common vascular injuries were pseudoaneurysms (45%) and arteriovenous fistulas (45%), most often involving the superficial femoral artery (82%). All procedures achieved 100% technical and procedural success. The median procedure time was 50 minutes (IQR: 37-73), and the median fluoroscopy time was 4.4 min (IQR: 2.4-7.3). During 30-day follow-up, one Class B adverse event (vasovagal reaction) and one Class D adverse event (intracranial hemorrhage, unrelated) were observed. No reinterventions, permanent sequelae, or deaths occurred. Conclusion: The single retrograde TA artery approach demonstrates high technical and procedural success, providing an effective alternative for managing femoral access complications. Further multicenter studies are needed to validate these findings and explore long-term outcomes.
- 11 October 2026
- Published by SAGE Publications in Vascular and Endovascular Surgery
Retrograde Tibialis Anterior Artery Access as an Alternative Route for Stent-Based Endovascular Repair of Femoral Access-Site Complications
Background: Femoral arterial access can lead to complications, including bleeding, pseudoaneurysms, arteriovenous fistulas (AVFs), and dissections. When utilizing endovascular methods, the treatment of these complications is typically performed via contralateral femoral access. For appropriate patients, the tibialis anterior (TA) approach offers a promising alternative, providing distal access with minimal risk of complications. This study evaluates the single retrograde TA approach for managing femoral artery access complications. Patients and Methods: A single-center retrospective analysis was conducted, including 11 patients who underwent endovascular treatment for femoral access complications via a single ipsilateral TA approach. Baseline demographics, procedural characteristics, and outcomes were collected from hospital records. Technical success was defined as the ability to obtain retrograde tibialis anterior access, advance a catheter to the target site, and deliver the intended therapy. Procedural success was defined as effective treatment of the vascular injury with preservation of patency in both the treated vessel and the tibialis anterior artery used for access. Results: Eleven patients (median age, 73 years; 55% male) underwent stent-based endovascular treatment. The most common vascular injuries were pseudoaneurysms (45%) and arteriovenous fistulas (45%), most often involving the superficial femoral artery (82%). All procedures achieved 100% technical and procedural success. The median procedure time was 50 minutes (IQR: 37-73), and the median fluoroscopy time was 4.4 min (IQR: 2.4-7.3). During 30-day follow-up, one Class B adverse event (vasovagal reaction) and one Class D adverse event (intracranial hemorrhage, unrelated) were observed. No reinterventions, permanent sequelae, or deaths occurred. Conclusion: The single retrograde TA artery approach demonstrates high technical and procedural success, providing an effective alternative for managing femoral access complications. Further multicenter studies are needed to validate these findings and explore long-term outcomes.
- Open Access
- 7 October 2026
- Published by JMIR Publications Inc. in JMIR AI
- Vol. 5, e104856
Safety-Filter Fallback on Consumer Health Questions During the Initial Claude Fable 5 Deployment: Observational Study
Background: Independent audits of medical large language models have concentrated on models that answer unsafely rather than those that decline safe questions. In June 2026, Anthropic released Claude Fable 5 with a safeguard that detects requests related to cybersecurity, biology, or chemistry and reroutes them to a fallback model, Claude Opus 4.8. The developer states that this safeguard is deliberately conservative and affects fewer than 5% of sessions. Whether that figure holds for consumer health questions, many containing dense biomedical vocabulary, was unknown. Objective: This study measured how often Claude Fable 5 routed consumer health questions to its fallback model and whether routing varied by clinical domain and framing. Methods: In this observational, point-in-time audit, the first 500 unique prompts in alphabetical order from the HealthSearchQA benchmark (3173 prompts) were each entered once into Claude Fable 5 through the web interface, in a new session with no system prompt and default settings, from June 9 to 12, 2026. Two reviewers independently coded each response as routed to fallback upfront or not routed upfront, with a third adjudicating disagreements. Midgeneration truncation due to a safety interruption was recorded separately. Prompts were labeled by clinical domain, question type, and sensitivity. Rates were reported with Wilson 95% CIs and compared using chi-square tests. Gemini 2.5 Flash served as an independent comparator. Results: Reviewers agreed on 474 of 500 responses (94.8%; Cohen κ=0.90; 95% CI 0.86-0.94). Fable 5 routed 243 (48.6%; 95% CI 44.2%-53.0%) prompts to the fallback. Of the 257 not routed upfront, 236 (91.8%; 95% CI 87.8%-94.6%) were fully answered and 21 (8.2%; 95% CI 5.4%-12.2%) were truncated midgeneration. Fallback routing varied by clinical domain ( χ 2 10 =59.5; P <.001), from 88.9% (32/36; 95% CI 74.7%-95.6%) for oncology and 79.3% (23/29; 95% CI 61.6%-90.2%) for reproductive and obstetric prompts to 26.3% (5/19; 95% CI 11.8%-48.8%) for mental and behavioral health. It also varied by question type ( χ 2 3 =61.9; P <.001): 63.1% (101/160; 95% CI 55.4%-70.2%) for prognosis or severity, 49.6% (137/276; 95% CI 43.8%-55.5%) for definition, and 1.8% (1/55; 95% CI 0.3%-9.6%) for diagnosis or treatment. Gemini answered 89.7% (218/243; 95% CI 85.3%-92.9%) of routed prompts and declined 19% (95/500; 95% CI 15.8%-22.7%) overall. Standardization to the full 3173-prompt question-type and domain compositions yielded fallback rates of 48.8% and 47.5%, respectively. Conclusions: Claude Fable 5 routed nearly half of these benchmark consumer health prompts away from the primary model, and routing was associated with clinical domain, question category, and disease vocabulary. Because benignness was not independently adjudicated, wording covaried with clinical content, and the fallback model’s subsequent answer was not recorded, these findings describe routing and truncation rather than user-facing refusal or a causal classifier feature. Fallback routing is a measurable safety property that audits should report alongside answer quality.
- 7 October 2026
- Published by JMIR Publications Inc. in JMIR AI
- Vol. 5, e104856
Open AccessSafety-Filter Fallback on Consumer Health Questions During the Initial Claude Fable 5 Deployment: Observational Study
Background: Independent audits of medical large language models have concentrated on models that answer unsafely rather than those that decline safe questions. In June 2026, Anthropic released Claude Fable 5 with a safeguard that detects requests related to cybersecurity, biology, or chemistry and reroutes them to a fallback model, Claude Opus 4.8. The developer states that this safeguard is deliberately conservative and affects fewer than 5% of sessions. Whether that figure holds for consumer health questions, many containing dense biomedical vocabulary, was unknown. Objective: This study measured how often Claude Fable 5 routed consumer health questions to its fallback model and whether routing varied by clinical domain and framing. Methods: In this observational, point-in-time audit, the first 500 unique prompts in alphabetical order from the HealthSearchQA benchmark (3173 prompts) were each entered once into Claude Fable 5 through the web interface, in a new session with no system prompt and default settings, from June 9 to 12, 2026. Two reviewers independently coded each response as routed to fallback upfront or not routed upfront, with a third adjudicating disagreements. Midgeneration truncation due to a safety interruption was recorded separately. Prompts were labeled by clinical domain, question type, and sensitivity. Rates were reported with Wilson 95% CIs and compared using chi-square tests. Gemini 2.5 Flash served as an independent comparator. Results: Reviewers agreed on 474 of 500 responses (94.8%; Cohen κ=0.90; 95% CI 0.86-0.94). Fable 5 routed 243 (48.6%; 95% CI 44.2%-53.0%) prompts to the fallback. Of the 257 not routed upfront, 236 (91.8%; 95% CI 87.8%-94.6%) were fully answered and 21 (8.2%; 95% CI 5.4%-12.2%) were truncated midgeneration. Fallback routing varied by clinical domain ( χ 2 10 =59.5; P <.001), from 88.9% (32/36; 95% CI 74.7%-95.6%) for oncology and 79.3% (23/29; 95% CI 61.6%-90.2%) for reproductive and obstetric prompts to 26.3% (5/19; 95% CI 11.8%-48.8%) for mental and behavioral health. It also varied by question type ( χ 2 3 =61.9; P <.001): 63.1% (101/160; 95% CI 55.4%-70.2%) for prognosis or severity, 49.6% (137/276; 95% CI 43.8%-55.5%) for definition, and 1.8% (1/55; 95% CI 0.3%-9.6%) for diagnosis or treatment. Gemini answered 89.7% (218/243; 95% CI 85.3%-92.9%) of routed prompts and declined 19% (95/500; 95% CI 15.8%-22.7%) overall. Standardization to the full 3173-prompt question-type and domain compositions yielded fallback rates of 48.8% and 47.5%, respectively. Conclusions: Claude Fable 5 routed nearly half of these benchmark consumer health prompts away from the primary model, and routing was associated with clinical domain, question category, and disease vocabulary. Because benignness was not independently adjudicated, wording covaried with clinical content, and the fallback model’s subsequent answer was not recorded, these findings describe routing and truncation rather than user-facing refusal or a causal classifier feature. Fallback routing is a measurable safety property that audits should report alongside answer quality.
- Open Access
AI agents at the brain-computer interface: separating inference from control
In medicine, AI agents are moving from generating text to executing actions, making uncertainty from upstream decoders a control problem. We studied this at the brain-computer interface using 1,065 episodes from 47 people with amyotrophic lateral sclerosis and five language models. Prompting agents with reconstructed decoder confidence never reduced unfaithful execution below a deterministic gate at matched coverage; two models were significantly worse. Apparent safety gains of up to 22 percentage points reflected acting less often, sometimes through invalid tool calls rather than explicit abstention. A post-hoc fair-information test gave ten models the same command vocabulary as a deterministic resolver. No direct agent arm improved on the resolver’s risk-coverage frontier, but a hybrid architecture in which models proposed semantic corrections and an external gate retained admission authority extended coverage beyond the resolver in five of ten models without observed unfaithful executions. These results separate inference from control in agentic neurotechnology.
Open AccessAI agents at the brain-computer interface: separating inference from control
In medicine, AI agents are moving from generating text to executing actions, making uncertainty from upstream decoders a control problem. We studied this at the brain-computer interface using 1,065 episodes from 47 people with amyotrophic lateral sclerosis and five language models. Prompting agents with reconstructed decoder confidence never reduced unfaithful execution below a deterministic gate at matched coverage; two models were significantly worse. Apparent safety gains of up to 22 percentage points reflected acting less often, sometimes through invalid tool calls rather than explicit abstention. A post-hoc fair-information test gave ten models the same command vocabulary as a deterministic resolver. No direct agent arm improved on the resolver’s risk-coverage frontier, but a hybrid architecture in which models proposed semantic corrections and an external gate retained admission authority extended coverage beyond the resolver in five of ten models without observed unfaithful executions. These results separate inference from control in agentic neurotechnology.
- Open Access
Limits of Trial-Adaptive Neural–Language Fusion Across Large Language Models in P300 Brain–Computer Interfaces
Objective: Published P300-speller fusion schemes fix prior trust regardless of trial reliability; we tested whether a reliability estimate improves on it. Methods: We reanalyzed 3,373 archived P300-speller selections from 47 people with ALS (BigP3BCI). A fair, matched-search-space comparison, tuning both a fixed weight and an adaptive policy out-of-fold, was evaluated across 22 evaluable language-model priors up to 46.7B parameters. Two representative priors, GPT-2 and a classical 5-gram, additionally received detailed naive and mechanistic analyses. Results: No prior’s 95% CI favored adaptive fusion under the fair comparison, despite unexploited oracle headroom at every scale. Under GPT-2, the naive comparison was significantly worse for adaptive fusion; both anchors converged to a degenerate or near-degenerate fair-comparison solution. For the representative anchors, three further controllers failed to convert that headroom into benefit; the fixed-fused posterior’s output probability outperformed the best controller for flagging errors (2.8- to 3.8-fold enrichment). Conclusion: A tuned fixed weight is a difficult-to-beat default across the tested scale range; reliability estimation gave no deployable adaptive advantage. Significance: Adaptive weighting should be validated against a fairly tuned baseline across model families and scales; in this dataset, the fused output’s confidence identified high-risk selections better than the tested purpose-built ranker.
Open AccessLimits of Trial-Adaptive Neural–Language Fusion Across Large Language Models in P300 Brain–Computer Interfaces
Objective: Published P300-speller fusion schemes fix prior trust regardless of trial reliability; we tested whether a reliability estimate improves on it. Methods: We reanalyzed 3,373 archived P300-speller selections from 47 people with ALS (BigP3BCI). A fair, matched-search-space comparison, tuning both a fixed weight and an adaptive policy out-of-fold, was evaluated across 22 evaluable language-model priors up to 46.7B parameters. Two representative priors, GPT-2 and a classical 5-gram, additionally received detailed naive and mechanistic analyses. Results: No prior’s 95% CI favored adaptive fusion under the fair comparison, despite unexploited oracle headroom at every scale. Under GPT-2, the naive comparison was significantly worse for adaptive fusion; both anchors converged to a degenerate or near-degenerate fair-comparison solution. For the representative anchors, three further controllers failed to convert that headroom into benefit; the fixed-fused posterior’s output probability outperformed the best controller for flagging errors (2.8- to 3.8-fold enrichment). Conclusion: A tuned fixed weight is a difficult-to-beat default across the tested scale range; reliability estimation gave no deployable adaptive advantage. Significance: Adaptive weighting should be validated against a fairly tuned baseline across model families and scales; in this dataset, the fused output’s confidence identified high-risk selections better than the tested purpose-built ranker.
- 29 August 2026
- Published by Elsevier in International Journal of Medical Informatics
- Vol. 222
OpenEvidence errs on the safe side in a structured test of triage recommendations
- 29 August 2026
- Published by Elsevier in International Journal of Medical Informatics
- Vol. 222
OpenEvidence errs on the safe side in a structured test of triage recommendations
- Open Access
Intent Drift in LLM-Assisted BCI Communication: An In-Silico Benchmark Under Simulated Decoder Corruption
Background: Large language models (LLMs) are increasingly used to correct noisy, error-prone text typed through brain-computer interfaces (BCIs) and other assistive communication devices. A fluent correction can still be wrong: the model can substitute a different intended message, a failure we call intent drift. Whether meaning survives correction, and whether model confidence flags failure, is unmeasured. Methods: We built an in-silico benchmark: 20 open-weight LLMs corrected simulated P300 speller text under five levels of decoder error (0-40% character error rate). Testing used the full ALS message-banking vocabulary, a set of clinically important messages (eg, involving a medication dose), and matched controls. Each of 4,252,326 outputs was scored faithful, degraded, or drifted by an automated system benchmarked against physicians. A separate subanalysis compared six correction strategies across seven models. Findings: Drift rose steeply with decoder error, from 2.2% at no error to 60.3% at the most severe level tested (odds ratio 2.30 per 10-percentage-point increase)-a stress-test ceiling, not an expected real-world rate. Model confidence distinguished correct from incorrect outputs reasonably well (AUROC 0.83) but overstated its own reliability: 28.4% of high-confidence outputs were not faithful. Clinically important messages drifted slightly more than matched controls (odds ratio 1.10). At low error rates, corrections succeeded more often than they went confidently wrong, but this reversed above 20-30% error. No correction strategy eliminated drift: cautious approaches reduced it, permissive ones increased it, and even the best still produced a wrong message in 18 of 100 corrections. Physician review of a sample agreed moderately with automated scoring (kappa 0.41); adjusting for this disagreement lowered but did not remove the pattern of rising drift with decoder error (31.4% to 28.3%). Interpretation: LLMs correcting BCI text produced fluent but sometimes wrong messages, more often as decoding quality worsened, and their own confidence did not reliably warn when this happened. These in-silico findings support evaluating such systems for meaning preservation, not only speed and accuracy, before deployment; prospective, human-in-the-loop evaluation is needed. Funding: Harvard Catalyst (CTSA UL1TR002541). Research in context: Evidence before this study: We searched PubMed, arXiv, and bioRxiv from database inception to July 19, 2026, combining terms for large language models with brain-computer interfaces, P300 spellers, and augmentative and alternative communication, without language restriction. Exact strings and record counts are in eMethods S9. Prior studies integrating large language models with P300 spellers and communication BCIs reported keystroke savings, typing speed, information transfer rate, and character-level accuracy. Some concluded that correction was near-optimal once residual errors were manually fixed, placing meaning-level change outside their frame. No study had measured how often post-editing changed a message’s intent, whether this depended on decoder corruption, or whether stated confidence tracked whether the output was faithful. Added value of this study: This in-silico benchmark measures intent drift and confidence calibration in language-model post-editing as a function of decoder corruption, reported separately across AUTH, a message-critical set, and matched controls. Using an empirical P300 confusion matrix and 4,252,326 labeled generations across 20 open-weight models, the primary benchmark questions found detected drift rose steeply with corruption and stated confidence discriminated faithful outputs well but was poorly calibrated; secondary analyses found message-critical content carried excess drift that survived detector removal and that detected drift varied more than two-fold across models (20.8-49.3% in AUTH). A separate subanalysis of six correction strategies (original seven-model panel) found no strategy removed drift: conservative editing or abstention lowered it, while alternatives or expansion raised it. Implications of all the available evidence: Evaluations of language-model-assisted communication BCIs and AAC systems should report intent drift and confidence calibration alongside speed and accuracy, should test message-critical content separately from routine messages, and should treat interface policy as a measured design variable. Because the construct is communicative intent, the absence of patient and public involvement in probe-set design is material. Because confidence did not reliably flag drift, it alone cannot gate human review. These are in-silico findings; they support the need for prospective, human-in-the-loop evaluation before deployment implications can be drawn.
Open AccessIntent Drift in LLM-Assisted BCI Communication: An In-Silico Benchmark Under Simulated Decoder Corruption
Background: Large language models (LLMs) are increasingly used to correct noisy, error-prone text typed through brain-computer interfaces (BCIs) and other assistive communication devices. A fluent correction can still be wrong: the model can substitute a different intended message, a failure we call intent drift. Whether meaning survives correction, and whether model confidence flags failure, is unmeasured. Methods: We built an in-silico benchmark: 20 open-weight LLMs corrected simulated P300 speller text under five levels of decoder error (0-40% character error rate). Testing used the full ALS message-banking vocabulary, a set of clinically important messages (eg, involving a medication dose), and matched controls. Each of 4,252,326 outputs was scored faithful, degraded, or drifted by an automated system benchmarked against physicians. A separate subanalysis compared six correction strategies across seven models. Findings: Drift rose steeply with decoder error, from 2.2% at no error to 60.3% at the most severe level tested (odds ratio 2.30 per 10-percentage-point increase)-a stress-test ceiling, not an expected real-world rate. Model confidence distinguished correct from incorrect outputs reasonably well (AUROC 0.83) but overstated its own reliability: 28.4% of high-confidence outputs were not faithful. Clinically important messages drifted slightly more than matched controls (odds ratio 1.10). At low error rates, corrections succeeded more often than they went confidently wrong, but this reversed above 20-30% error. No correction strategy eliminated drift: cautious approaches reduced it, permissive ones increased it, and even the best still produced a wrong message in 18 of 100 corrections. Physician review of a sample agreed moderately with automated scoring (kappa 0.41); adjusting for this disagreement lowered but did not remove the pattern of rising drift with decoder error (31.4% to 28.3%). Interpretation: LLMs correcting BCI text produced fluent but sometimes wrong messages, more often as decoding quality worsened, and their own confidence did not reliably warn when this happened. These in-silico findings support evaluating such systems for meaning preservation, not only speed and accuracy, before deployment; prospective, human-in-the-loop evaluation is needed. Funding: Harvard Catalyst (CTSA UL1TR002541). Research in context: Evidence before this study: We searched PubMed, arXiv, and bioRxiv from database inception to July 19, 2026, combining terms for large language models with brain-computer interfaces, P300 spellers, and augmentative and alternative communication, without language restriction. Exact strings and record counts are in eMethods S9. Prior studies integrating large language models with P300 spellers and communication BCIs reported keystroke savings, typing speed, information transfer rate, and character-level accuracy. Some concluded that correction was near-optimal once residual errors were manually fixed, placing meaning-level change outside their frame. No study had measured how often post-editing changed a message’s intent, whether this depended on decoder corruption, or whether stated confidence tracked whether the output was faithful. Added value of this study: This in-silico benchmark measures intent drift and confidence calibration in language-model post-editing as a function of decoder corruption, reported separately across AUTH, a message-critical set, and matched controls. Using an empirical P300 confusion matrix and 4,252,326 labeled generations across 20 open-weight models, the primary benchmark questions found detected drift rose steeply with corruption and stated confidence discriminated faithful outputs well but was poorly calibrated; secondary analyses found message-critical content carried excess drift that survived detector removal and that detected drift varied more than two-fold across models (20.8-49.3% in AUTH). A separate subanalysis of six correction strategies (original seven-model panel) found no strategy removed drift: conservative editing or abstention lowered it, while alternatives or expansion raised it. Implications of all the available evidence: Evaluations of language-model-assisted communication BCIs and AAC systems should report intent drift and confidence calibration alongside speed and accuracy, should test message-critical content separately from routine messages, and should treat interface policy as a measured design variable. Because the construct is communicative intent, the absence of patient and public involvement in probe-set design is material. Because confidence did not reliably flag drift, it alone cannot gate human review. These are in-silico findings; they support the need for prospective, human-in-the-loop evaluation before deployment implications can be drawn.
- Open Access
Quantifying Large Language Model Influence in Brain Computer Interface Communication for Amyotrophic Lateral Sclerosis
Large language models are integrated into brain-computer interfaces for communication, but accuracy does not show whether an emitted character depended on neural evidence or on the language-model prior. We retrospectively re-decoded 3,373 P300-speller selections from 47 people with amyotrophic lateral sclerosis, reconstructing a neural posterior and combining it with 25 language priors ranging from 5-grams to 46.7-billion-parameter models. Under held-out, per-source calibration and equal fusion weighting, the prior accounted for a participant-weighted mean 8.6% of posterior displacement (median across selections, 2.9%); the corresponding neural contribution fraction was 0.914 (95% CI, 0.896-0.934). In 4.4% of selections (95% CI, 3.5-5.3), the fused system emitted the intended character although neural evidence alone would not have selected it. Results were similar across 21 neural language models. Accuracy alone does not reveal how strongly a fused brain-computer interface decision depends on its language prior.
Open AccessQuantifying Large Language Model Influence in Brain Computer Interface Communication for Amyotrophic Lateral Sclerosis
Large language models are integrated into brain-computer interfaces for communication, but accuracy does not show whether an emitted character depended on neural evidence or on the language-model prior. We retrospectively re-decoded 3,373 P300-speller selections from 47 people with amyotrophic lateral sclerosis, reconstructing a neural posterior and combining it with 25 language priors ranging from 5-grams to 46.7-billion-parameter models. Under held-out, per-source calibration and equal fusion weighting, the prior accounted for a participant-weighted mean 8.6% of posterior displacement (median across selections, 2.9%); the corresponding neural contribution fraction was 0.914 (95% CI, 0.896-0.934). In 4.4% of selections (95% CI, 3.5-5.3), the fused system emitted the intended character although neural evidence alone would not have selected it. Results were similar across 21 neural language models. Accuracy alone does not reveal how strongly a fused brain-computer interface decision depends on its language prior.
- Open Access
Assigned roles change how clinical AI agents allocate shared resources
Clinical AI agents may be assigned to individual patients, but hospital resources are shared across many patients. We tested what agents do when helping their assigned patient would violate the hospital’s rule for a scarce resource. We analyzed 22,916 simulated cases comprising 274,992 logged agent actions across 20 AI models. In each scenario, the agent could claim a scarce resource for its patient even though the hospital rule gave another patient priority. We varied only the agent’s assigned role, from responsibility for the whole ward to strong advocacy for one patient. Violations of the hospital rule rose from 32.5% under whole-ward responsibility to 69.4% under strong patient advocacy, a 36.9-point increase (95% CI, 25.7–48.0). Agents correctly identified which patient should receive the resource in 95.7% of tests, yet still took it for their own patient in 65.9% of those episodes. Asking the agent to apply its own allocation judgment immediately before acting reduced violations to 0–2% in a three-model follow-up experiment. Assigned roles can shape how clinical AI agents use shared hospital resources, even when they identify the correct priority patient. Patient-focused agents should not independently control shared resources without an allocation check.
Open AccessAssigned roles change how clinical AI agents allocate shared resources
Clinical AI agents may be assigned to individual patients, but hospital resources are shared across many patients. We tested what agents do when helping their assigned patient would violate the hospital’s rule for a scarce resource. We analyzed 22,916 simulated cases comprising 274,992 logged agent actions across 20 AI models. In each scenario, the agent could claim a scarce resource for its patient even though the hospital rule gave another patient priority. We varied only the agent’s assigned role, from responsibility for the whole ward to strong advocacy for one patient. Violations of the hospital rule rose from 32.5% under whole-ward responsibility to 69.4% under strong patient advocacy, a 36.9-point increase (95% CI, 25.7–48.0). Agents correctly identified which patient should receive the resource in 95.7% of tests, yet still took it for their own patient in 65.9% of those episodes. Asking the agent to apply its own allocation judgment immediately before acting reduced violations to 0–2% in a three-model follow-up experiment. Assigned roles can shape how clinical AI agents use shared hospital resources, even when they identify the correct priority patient. Patient-focused agents should not independently control shared resources without an allocation check.