I. A. Taymasova
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
I. A. Taymasova has a total of 26 co-authors. Here are the top co-authors by number of shared publications:
- Amiran Sh. Revishvili
Vishnevsky National Medical Research Center of Surgery; Russian Medical Academy of Continuous Professional Education
13 shared publications - Elena Alexandrovna Artyukhina
Vishnevsky National Medical Research Center of Surgery; Russian Medical Academy of Continuous Professional Education
10 shared publications - M. V. Yashkov
Federal State Budgetary Institution “National Medical Research Center of Surgery named after A. Vishnevsky” of the Ministry of Health of the Russian Federation
6 shared publications - Elizaveta V. Dedukh
Federal State Budgetary Institution “National Medical Research Center of Surgery named after A. Vishnevsky” of the Ministry of Health of the Russian Federation
5 shared publications - N. M. Kuznetsov
FSBI «A.V.Vishnevsky National Medical Research Center of Surgery” of the MH RF
3 shared publications - V. A. Vaskovskiy
Federal State Budgetary Institution “National Medical Research Center of Surgery named after A. Vishnevsky” of the Ministry of Health of the Russian Federation
3 shared publications
Latest Publications
- Open Access
- 4 July 2023
- Published by Cardiology Research Institute in Siberian Journal of Clinical and Experimental Medicine
- Vol. 38 (2) , 44-50
Intraoperative monitoring of intraesophageal temperature during radiofrequency ablation of the posterior wall of the left atrium in atrial fibrillation (literature review)
Currently catheter radiofrequency ablation (RFA) has become the standard treatment for patients with atrial fibrillation (AF). During RFA, additional linear lesions are performed along the posterior wall of the left atrium, which can cause damage to the esophagus. The manuscript considers the methods introduced into practice to prevent damage to the esophagus during RFA, the pros and cons of the techniques.
- 4 July 2023
- Published by Cardiology Research Institute in Siberian Journal of Clinical and Experimental Medicine
- Vol. 38 (2) , 44-50
Open AccessIntraoperative monitoring of intraesophageal temperature during radiofrequency ablation of the posterior wall of the left atrium in atrial fibrillation (literature review)
Currently catheter radiofrequency ablation (RFA) has become the standard treatment for patients with atrial fibrillation (AF). During RFA, additional linear lesions are performed along the posterior wall of the left atrium, which can cause damage to the esophagus. The manuscript considers the methods introduced into practice to prevent damage to the esophagus during RFA, the pros and cons of the techniques.
- Open Access
- 23 June 2023
- Published by Institute of Cardio Technics - INCART in Journal of Arrhythmology
- Vol. 30 (2) , 11-19
Comparative analysis of long-term outcomes of thoracoscopic and ablation index-guided catheter ablation in patients with non-paroxysmal atrial fibrillation
Aim. To conduct a comparative assessment of the long-term results of thoracoscopic and catheter ablation using the ablation index in patients with non-paroxysmal atrial fibrillation (AF).Methods. A comparative analysis of the long-term results of catheter ablation using the ablation index - group № 1 (36 patients) and thoracoscopic ablation with the left atrial appendage exclusion - group № 2 (42 patients) was performed.Results. The effectiveness of catheter ablation was 57.14%, thoracoscopic ablation - 67.5% at 12-month followup (р=0,128). There were also no statistically significant differences in safety (p=0.55). Analyzing the structure of postprocedural atrial tachycardias in group №1 was demonstrated that AF recurrence was in 93.3%, in group №2 - in 50%. Atypical atrial flutter was documented in 6.6% of cases in group №1 and in 31.5% - in group №2. Typical atrial flutter was documented only in group №2 (18.75% (3)). However, AF recurrence was more common in the catheter ablation group after 6 months of follow-up (p=0.04).Conclusion. Catheter and thoracoscopic ablation are comparable in terms of overall efficacy and safety, however, thoracoscopic ablation provides greater freedom from AF in a 6 month.
- 23 June 2023
- Published by Institute of Cardio Technics - INCART in Journal of Arrhythmology
- Vol. 30 (2) , 11-19
Open AccessComparative analysis of long-term outcomes of thoracoscopic and ablation index-guided catheter ablation in patients with non-paroxysmal atrial fibrillation
Aim. To conduct a comparative assessment of the long-term results of thoracoscopic and catheter ablation using the ablation index in patients with non-paroxysmal atrial fibrillation (AF).Methods. A comparative analysis of the long-term results of catheter ablation using the ablation index - group № 1 (36 patients) and thoracoscopic ablation with the left atrial appendage exclusion - group № 2 (42 patients) was performed.Results. The effectiveness of catheter ablation was 57.14%, thoracoscopic ablation - 67.5% at 12-month followup (р=0,128). There were also no statistically significant differences in safety (p=0.55). Analyzing the structure of postprocedural atrial tachycardias in group №1 was demonstrated that AF recurrence was in 93.3%, in group №2 - in 50%. Atypical atrial flutter was documented in 6.6% of cases in group №1 and in 31.5% - in group №2. Typical atrial flutter was documented only in group №2 (18.75% (3)). However, AF recurrence was more common in the catheter ablation group after 6 months of follow-up (p=0.04).Conclusion. Catheter and thoracoscopic ablation are comparable in terms of overall efficacy and safety, however, thoracoscopic ablation provides greater freedom from AF in a 6 month.
- Open Access
- 3 March 2023
- Published by Cardiology Research Institute in Siberian Journal of Clinical and Experimental Medicine
Intraoperative monitoring of intraesophageal temperature during radiofrequency ablation of the posterior wall of the left atrium in atrial fibrillation (literature review)
Currently catheter radiofrequency ablation (RFA) has become the standard treatment for patients with atrial fibrillation (AF). During RFA, additional linear lesions are performed along the posterior wall of the left atrium, which can cause damage to the esophagus.The manuscript considers the methods introduced into practice to prevent damage to the esophagus during RFA, the pros and cons of the techniques.
- 3 March 2023
- Published by Cardiology Research Institute in Siberian Journal of Clinical and Experimental Medicine
Open AccessIntraoperative monitoring of intraesophageal temperature during radiofrequency ablation of the posterior wall of the left atrium in atrial fibrillation (literature review)
Currently catheter radiofrequency ablation (RFA) has become the standard treatment for patients with atrial fibrillation (AF). During RFA, additional linear lesions are performed along the posterior wall of the left atrium, which can cause damage to the esophagus.The manuscript considers the methods introduced into practice to prevent damage to the esophagus during RFA, the pros and cons of the techniques.
- Open Access
- 8 December 2022
- Published by Institute of Cardio Technics - INCART in Journal of Arrhythmology
- Vol. 29 (4) , 66-72
Stereotactic radioablation in clinical practice for the treatment of a patient with ventricular tachycardia: case report
The aim of the study is the demonstration of the 1st clinical experience of stereotactic arrhythmia radioablation (STAR) of the patient with antiarrhythmic drug (AAD) refractory ventricular tachycardia (VT) in Russia. The results of STAR of 57 years old patient with AAD and multiple radiofrequency ablation refractory VT are described. This clinical study demonstrates efficacy and safety of STAR of VT.
- 8 December 2022
- Published by Institute of Cardio Technics - INCART in Journal of Arrhythmology
- Vol. 29 (4) , 66-72
Open AccessStereotactic radioablation in clinical practice for the treatment of a patient with ventricular tachycardia: case report
The aim of the study is the demonstration of the 1st clinical experience of stereotactic arrhythmia radioablation (STAR) of the patient with antiarrhythmic drug (AAD) refractory ventricular tachycardia (VT) in Russia. The results of STAR of 57 years old patient with AAD and multiple radiofrequency ablation refractory VT are described. This clinical study demonstrates efficacy and safety of STAR of VT.
- Open Access
- 8 December 2022
- Published by Institute of Cardio Technics - INCART in Journal of Arrhythmology
- Vol. 29 (4) , 47-52
The first use of POLARx cryoballoon catheter for pulmonary vein isolation in patients with atrial fibrillation: case series
There is the first clinical use of POLARx cryoballoon catheter for pulmonary vein isolation in patients with atrial fibrillation in Russian Federation.
- 8 December 2022
- Published by Institute of Cardio Technics - INCART in Journal of Arrhythmology
- Vol. 29 (4) , 47-52
Open AccessThe first use of POLARx cryoballoon catheter for pulmonary vein isolation in patients with atrial fibrillation: case series
There is the first clinical use of POLARx cryoballoon catheter for pulmonary vein isolation in patients with atrial fibrillation in Russian Federation.
- Open Access
- 20 September 2022
- Published by Institute of Cardio Technics - INCART in Journal of Arrhythmology
- Vol. 29 (3) , 29-36
Algorithm for determining the fibrosis stage using high-density mapping
Aims. To develop an algorithm for assessing the stage of fibrosis based on high-density endocardial mapping. To study the effect of the stage of left atrial (LA) fibrosis on the results of atrial fibrillation (AF) catheter ablation.Methods. The study included 64 patients with paroxysmal or persistent AF, who underwent high-density LA mapping and catheter ablation. After the intervention procedure, we analyzed the electroanatomical maps of the left atrium, assessed the prevalence of low-voltage areas according to the developed algorithm. Patients were divided into 4 groups depending on the prevalence of areas of low voltage based on the Utah score.Results. The follow-up period was 14.5 ± 6.7 months. AF recurrence developed in 18 (28.1%) patients after the ablation procedure. AF recurrence after ablation was more frequent in patients with a low-voltage area of more than 20% than in patients with a low-voltage left atrial area of less than 20%, 6 (15.4%) versus 12 (48%), p=0.02. A logistic regression analysis was performed to identify AF recurrence predictors in the postoperative period. As a result, only widespread areas of low-amplitude activity were an independent predictor of AF recurrence after the pulmonary veins isolation, this predictive model was significant (p=0.026). Significant statistical differences between groups I, II and III,I V are the ejection fractions and the duration of the P-wave. Patients with low-voltage regions have lower left ventricular ejection fraction (62.8±6.9% versus 58.1±5.7%, p=0.01), and longer P-wave duration (84.7±8,2 ms versus 101.5±11.0 ms, p=0.01).Conclusion. LA high-density mapping before AF ablation makes it possible to determine the prevalence of low-voltage areas. After regression analysis, it was proved that common low-voltage areas are an independent predictor of AF recurrence after pulmonary vein isolation. Patients with low-voltage areas of more than 20% of the LA surface have longer P-wave duration and lower left ventricular ejection fraction.
- 20 September 2022
- Published by Institute of Cardio Technics - INCART in Journal of Arrhythmology
- Vol. 29 (3) , 29-36
Open AccessAlgorithm for determining the fibrosis stage using high-density mapping
Aims. To develop an algorithm for assessing the stage of fibrosis based on high-density endocardial mapping. To study the effect of the stage of left atrial (LA) fibrosis on the results of atrial fibrillation (AF) catheter ablation.Methods. The study included 64 patients with paroxysmal or persistent AF, who underwent high-density LA mapping and catheter ablation. After the intervention procedure, we analyzed the electroanatomical maps of the left atrium, assessed the prevalence of low-voltage areas according to the developed algorithm. Patients were divided into 4 groups depending on the prevalence of areas of low voltage based on the Utah score.Results. The follow-up period was 14.5 ± 6.7 months. AF recurrence developed in 18 (28.1%) patients after the ablation procedure. AF recurrence after ablation was more frequent in patients with a low-voltage area of more than 20% than in patients with a low-voltage left atrial area of less than 20%, 6 (15.4%) versus 12 (48%), p=0.02. A logistic regression analysis was performed to identify AF recurrence predictors in the postoperative period. As a result, only widespread areas of low-amplitude activity were an independent predictor of AF recurrence after the pulmonary veins isolation, this predictive model was significant (p=0.026). Significant statistical differences between groups I, II and III,I V are the ejection fractions and the duration of the P-wave. Patients with low-voltage regions have lower left ventricular ejection fraction (62.8±6.9% versus 58.1±5.7%, p=0.01), and longer P-wave duration (84.7±8,2 ms versus 101.5±11.0 ms, p=0.01).Conclusion. LA high-density mapping before AF ablation makes it possible to determine the prevalence of low-voltage areas. After regression analysis, it was proved that common low-voltage areas are an independent predictor of AF recurrence after pulmonary vein isolation. Patients with low-voltage areas of more than 20% of the LA surface have longer P-wave duration and lower left ventricular ejection fraction.
- 5 August 2022
- Published by Vidar, Ltd. in Medical Visualization
- Vol. 26 (3) , 22-33
Influence of Left Atrium Volume Index on effectiveness of Thoracoscopic Ablation in the Treatment of Atrial Fibrillation
Research objective: establish the impact of Left Atrium Volume Index (LAVI) on on effectiveness of Thoracoscopic Ablation (TSA) in the Treatment of Atrial Fibrillation (AF) and define the risk factors for manifestation of supraventricular arrhythmias in the long-term follow-up results Methods. Prospective cohort study of 121 patients with AF (from 2018 to 2021) who performed TSA. The patients were divided into two groups: patients with increased LAVI (group I), patients with normal LAVI less than 34 ml/m 2 (group II). Results. According to echocardiography, the mean LAVI was 45.48 ± 9.3 ml/m 2 and 28.59 ± 4.13 ml/m 2 in groups I and II, respectively (p = 0.012). The mean value of left ventricular ejection fraction (LVEF) according to Teicholz in group I was 61.62 ± 7.041%, in group II 63.57 ± 6.16% (p = 0.8). Spearman's сorrelation analysis showed the relationship between LAVI and LVEF before surgery and in the long-term follow-up period, that is agreed with world literature data about contribution left atrial (LA) to left ventricular (LV) function. According to our study, only LAVI < 34 ml/m 2 is a risk factor for arrhythmia after TSA. Effectiveness TSA in I group was 77.8%, that is lower than the II group – 88.9%. 3 months after TSA, 20 (17%) patients were required catheter ablations (CA), mainly in I group. Conclusions. Research results showed that an increase in LAVI significantly reduces the effectiveness of TSA in the long-term period by 11.1% compared with LAVI < 34 ml/m 2 . That are conform with other data of previously submitted works.
- 5 August 2022
- Published by Vidar, Ltd. in Medical Visualization
- Vol. 26 (3) , 22-33
Influence of Left Atrium Volume Index on effectiveness of Thoracoscopic Ablation in the Treatment of Atrial Fibrillation
Research objective: establish the impact of Left Atrium Volume Index (LAVI) on on effectiveness of Thoracoscopic Ablation (TSA) in the Treatment of Atrial Fibrillation (AF) and define the risk factors for manifestation of supraventricular arrhythmias in the long-term follow-up results Methods. Prospective cohort study of 121 patients with AF (from 2018 to 2021) who performed TSA. The patients were divided into two groups: patients with increased LAVI (group I), patients with normal LAVI less than 34 ml/m 2 (group II). Results. According to echocardiography, the mean LAVI was 45.48 ± 9.3 ml/m 2 and 28.59 ± 4.13 ml/m 2 in groups I and II, respectively (p = 0.012). The mean value of left ventricular ejection fraction (LVEF) according to Teicholz in group I was 61.62 ± 7.041%, in group II 63.57 ± 6.16% (p = 0.8). Spearman's сorrelation analysis showed the relationship between LAVI and LVEF before surgery and in the long-term follow-up period, that is agreed with world literature data about contribution left atrial (LA) to left ventricular (LV) function. According to our study, only LAVI < 34 ml/m 2 is a risk factor for arrhythmia after TSA. Effectiveness TSA in I group was 77.8%, that is lower than the II group – 88.9%. 3 months after TSA, 20 (17%) patients were required catheter ablations (CA), mainly in I group. Conclusions. Research results showed that an increase in LAVI significantly reduces the effectiveness of TSA in the long-term period by 11.1% compared with LAVI < 34 ml/m 2 . That are conform with other data of previously submitted works.
- Open Access
- 31 March 2022
- Published by Meshalkin National Medical Research Center in Patologiya krovoobrashcheniya i kardiokhirurgiya
- Vol. 26 (1) , 73-82
Evaluation of the effectiveness of interventional treatment of ventricular arrhythmias of rare localizations using non-invasive mapping
Background. Atypical localization of the focus of ventricular arrhythmias is a rather difficult group for invasive mapping and subsequent radiofrequency ablation. Invasive electroanatomical mapping, multipolar electrophysiological electrodes in combination with electrophysiological study for searching an early zone of arrhythmia focus, and substrate mapping, are aimed to identifying critical areas of the arrhythmia contour. However, there are still situations in which arrhythmia cannot be eliminated, despite the use of these systems. The method of superficial non-invasive mapping of the heart seems to be relevant, which makes it possible to estimate the volume of surgery and select the necessary technology to eliminate arrhythmias.Aim. To compare the effectiveness of interventional treatment of patients with ventricular arrhythmias of atypical localization with and without the use of superficial non-invasive mapping.Methods. The study included 40 patients with ventricular arrhythmias of rare localization. The patients were divided into two groups. Group I included 21 patients who underwent non-invasive superficial and invasive electrophysiological cardiac mapping. Group II included 19 patients who underwent invasive electrophysiological cardiac mapping.Results. Over a follow-up period of 12 months, the freedom from arrhythmia in group I was 76%, in group II — 61%. The total operation time, duration and dose of fluoroscopy were less in group I compared to the group II.Conclusion. The study results demonstrated that the method of non-invasive surface mapping of the heart is highly effective in ventricular arrhythmias of atypical localization. The time of radiofrequency ablation, interventional intervention, fluoroscopy is lower with the use of superficial non-invasive mapping, compared with the control group. Received 13 July 2021. Revised 20 October 2021. Accepted 9 December 2021. Funding: This work is supported by a grant of the Russian Science Foundation (project No. 19-15-00406). Conflict of interest: The authors declare no conflict of interest. Contribution of the authorsConception and study design: E.A. Artyukhina, A.Sh. RevishviliData collection and analysis: E.A. Artyukhina, M.V. Yashkov, E.V. Dedukh, I.A. Taymasova, A.Sh. RevishviliStatistical analysis: M.V. YashkovDrafting the article: E.A. Artyukhina, M.V. YashkovCritical revision of the article: E.A. Artyukhina, M.V. Yashkov, A.Sh. RevishviliFinal approval of the version to be published: E.A. Artyukhina, M.V. Yashkov, E.V. Dedukh, I.A. Taymasova, A.Sh. Revishvili
- 31 March 2022
- Published by Meshalkin National Medical Research Center in Patologiya krovoobrashcheniya i kardiokhirurgiya
- Vol. 26 (1) , 73-82
Open AccessEvaluation of the effectiveness of interventional treatment of ventricular arrhythmias of rare localizations using non-invasive mapping
Background. Atypical localization of the focus of ventricular arrhythmias is a rather difficult group for invasive mapping and subsequent radiofrequency ablation. Invasive electroanatomical mapping, multipolar electrophysiological electrodes in combination with electrophysiological study for searching an early zone of arrhythmia focus, and substrate mapping, are aimed to identifying critical areas of the arrhythmia contour. However, there are still situations in which arrhythmia cannot be eliminated, despite the use of these systems. The method of superficial non-invasive mapping of the heart seems to be relevant, which makes it possible to estimate the volume of surgery and select the necessary technology to eliminate arrhythmias.Aim. To compare the effectiveness of interventional treatment of patients with ventricular arrhythmias of atypical localization with and without the use of superficial non-invasive mapping.Methods. The study included 40 patients with ventricular arrhythmias of rare localization. The patients were divided into two groups. Group I included 21 patients who underwent non-invasive superficial and invasive electrophysiological cardiac mapping. Group II included 19 patients who underwent invasive electrophysiological cardiac mapping.Results. Over a follow-up period of 12 months, the freedom from arrhythmia in group I was 76%, in group II — 61%. The total operation time, duration and dose of fluoroscopy were less in group I compared to the group II.Conclusion. The study results demonstrated that the method of non-invasive surface mapping of the heart is highly effective in ventricular arrhythmias of atypical localization. The time of radiofrequency ablation, interventional intervention, fluoroscopy is lower with the use of superficial non-invasive mapping, compared with the control group. Received 13 July 2021. Revised 20 October 2021. Accepted 9 December 2021. Funding: This work is supported by a grant of the Russian Science Foundation (project No. 19-15-00406). Conflict of interest: The authors declare no conflict of interest. Contribution of the authorsConception and study design: E.A. Artyukhina, A.Sh. RevishviliData collection and analysis: E.A. Artyukhina, M.V. Yashkov, E.V. Dedukh, I.A. Taymasova, A.Sh. RevishviliStatistical analysis: M.V. YashkovDrafting the article: E.A. Artyukhina, M.V. YashkovCritical revision of the article: E.A. Artyukhina, M.V. Yashkov, A.Sh. RevishviliFinal approval of the version to be published: E.A. Artyukhina, M.V. Yashkov, E.V. Dedukh, I.A. Taymasova, A.Sh. Revishvili
- 31 December 2021
- Published by APO Society of Specialists in Heart Failure in Kardiologiia
- Vol. 61 (12) , 108-116
History of development of ventricular arrhythmias diagnostics
This review shows historical steps in the development of topical diagnostics for ventricular arrhythmias, the current status of this issue, and the relevance of developing topical, noninvasive electrophysiological cardiac mapping.
- 31 December 2021
- Published by APO Society of Specialists in Heart Failure in Kardiologiia
- Vol. 61 (12) , 108-116
History of development of ventricular arrhythmias diagnostics
This review shows historical steps in the development of topical diagnostics for ventricular arrhythmias, the current status of this issue, and the relevance of developing topical, noninvasive electrophysiological cardiac mapping.
- Open Access
- 25 December 2021
- Published by Institute of Cardio Technics - INCART in Journal of Arrhythmology
- Vol. 28 (4) , 57-61
Intraprocedural electrocardiographic imaging of a hemodynamically unstable ischemic ventricular tachycardia originating from the interventricular septum
The article presents a clinical case of catheter treatment of hemodynamically unstable ischemic ventricular tachycardia originating from interventricular septum using electrocardiographic imaging and high-density endocardial substrate mapping.
- 25 December 2021
- Published by Institute of Cardio Technics - INCART in Journal of Arrhythmology
- Vol. 28 (4) , 57-61
Open AccessIntraprocedural electrocardiographic imaging of a hemodynamically unstable ischemic ventricular tachycardia originating from the interventricular septum
The article presents a clinical case of catheter treatment of hemodynamically unstable ischemic ventricular tachycardia originating from interventricular septum using electrocardiographic imaging and high-density endocardial substrate mapping.