Amin Qureshi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Amin Qureshi has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
Sabha Raj Arya
Sardar Vallabhbhai National Institute of Technology
4 shared publicationsAshutosh K. Giri
3 shared publications- Ashutosh K. Giri
Government Engineering College Bharuch
2 shared publications - Chitti Babu Baladhandautham
Indian Institute of Information Technology, Design and Manufacturing
2 shared publications Nunsavath Sharath Kumar
2 shared publicationsRakesh Maurya
Sardar Vallabhbhai National Institute of Technology
2 shared publications
Latest Publications
- 20 June 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-7
System Identifications, Validation and Overall Mathematical Modeling of Small Scale Wind Turbine
In this paper, calculation of overall system parameters, identification through laboratory setup and its validation has been done. Moreover, comparative performance of sensor and sensorless control for Permanent Magnet Synchronous Generator (PMSG) with DC bus is presented. The system model contains a PMSG model, sensorless Extended Kalman Filter (EKF), three phase Voltage Source Converter (VSC) with fix DC bus system. Overall system modeling of PMSG and calculation from the scratch of the parameters such as, generator phase resistance (Rs), d-q axis inductance (Ld-Lq), rotor flux linkage (λr) etc. have been defined in this paper. However, Identified parameters are used in hardware prototype in order to validate and verify system performance. Generator measured speed, d-q axis currents are control by Field Oriented Control (FOC) in sensor-based system, and estimated parameters are used in sensorless control scheme. Hardware prototype is used for parameters identification and experiments, which comprises of, individual gear-less PMSG, ETH position sensor, LEM voltage and current sensors, and dSP ACE microlab box.
- 20 June 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-7
System Identifications, Validation and Overall Mathematical Modeling of Small Scale Wind Turbine
In this paper, calculation of overall system parameters, identification through laboratory setup and its validation has been done. Moreover, comparative performance of sensor and sensorless control for Permanent Magnet Synchronous Generator (PMSG) with DC bus is presented. The system model contains a PMSG model, sensorless Extended Kalman Filter (EKF), three phase Voltage Source Converter (VSC) with fix DC bus system. Overall system modeling of PMSG and calculation from the scratch of the parameters such as, generator phase resistance (Rs), d-q axis inductance (Ld-Lq), rotor flux linkage (λr) etc. have been defined in this paper. However, Identified parameters are used in hardware prototype in order to validate and verify system performance. Generator measured speed, d-q axis currents are control by Field Oriented Control (FOC) in sensor-based system, and estimated parameters are used in sensorless control scheme. Hardware prototype is used for parameters identification and experiments, which comprises of, individual gear-less PMSG, ETH position sensor, LEM voltage and current sensors, and dSP ACE microlab box.
- Open Access
Risk Mitigation of Poor Power Quality Issues of Standalone Wind Turbines: An Efficacy Study of Synchronous Reference Frame (SRF) Control
This paper validates and presents the efficiency and performance of Synchronous Reference Frame (SRF) control as a mitigating control in managing risks of high volatility of electric current flows from the wind turbine generator to the distributed load. High volatility/fluctuations of electricity (high current, voltage disturbance) and frequency are hazards that can trip off or, in extreme cases, burn down a whole wind turbine generator. An advanced control scheme is used to control a Voltage Source Converter (VSC)-based three-phase induction generator with a Battery Energy Storage System (BESS). For the purpose of risk mitigation of harmonics, this scheme converts three-phase input quantity to two-phase Direct Current (DC) quantity (dq) so that the reactive power compensation decreases the harmonics level. Thus, no other analog filters are required to produce the reconstructed signal of fundamental frequency. In this paper, the values of Proportional Integral (PI) regulators are calculated through the “MONTE CARLO” optimization tool. Furthermore, risk analysis is carried out using bowtie, risk matrix and ALARP (as low as reasonably practicable) methods, which is the novelty based on the parametric study of this research work. The results reveal that by inducting proposed SRF control into the Wind Energy Conversion System (WECS), the risks of high fluctuations and disturbances in signals are reduced to an acceptable level as per the standards of IEEE 519-2014 and EN 50160. The proposed work is validated through running simulations in MATLAB/Simulink with and without controls.
Open AccessRisk Mitigation of Poor Power Quality Issues of Standalone Wind Turbines: An Efficacy Study of Synchronous Reference Frame (SRF) Control
This paper validates and presents the efficiency and performance of Synchronous Reference Frame (SRF) control as a mitigating control in managing risks of high volatility of electric current flows from the wind turbine generator to the distributed load. High volatility/fluctuations of electricity (high current, voltage disturbance) and frequency are hazards that can trip off or, in extreme cases, burn down a whole wind turbine generator. An advanced control scheme is used to control a Voltage Source Converter (VSC)-based three-phase induction generator with a Battery Energy Storage System (BESS). For the purpose of risk mitigation of harmonics, this scheme converts three-phase input quantity to two-phase Direct Current (DC) quantity (dq) so that the reactive power compensation decreases the harmonics level. Thus, no other analog filters are required to produce the reconstructed signal of fundamental frequency. In this paper, the values of Proportional Integral (PI) regulators are calculated through the “MONTE CARLO” optimization tool. Furthermore, risk analysis is carried out using bowtie, risk matrix and ALARP (as low as reasonably practicable) methods, which is the novelty based on the parametric study of this research work. The results reveal that by inducting proposed SRF control into the Wind Energy Conversion System (WECS), the risks of high fluctuations and disturbances in signals are reduced to an acceptable level as per the standards of IEEE 519-2014 and EN 50160. The proposed work is validated through running simulations in MATLAB/Simulink with and without controls.
- 7 June 2020
- Published by Taylor & Francis in Energy Sources, Part A: Recovery, Utilization, and Environmental Effects
- Vol. 47 (2)
Power quality solutions for effective utilization of single-phase induction generator using voltage source converter
In this paper, the effective utilization of single-phase self-excited induction generator (SEIG) with improved power quality features with the help of voltage source converter (VSC) is presented. This generator works as an isolated single-phase distributed power generation system. In this case, the frequency and voltage control of induction generator feeding linear/nonlinear load is carried out using VSC under different operating characteristics. The power quality issues such as reactive power compensation, voltage regulation, harmonics reduction have been addressed. The VSC is operated by the reference current extracted from the distorted load current using adaptive theory-based Improved Linear Sinusoidal Tracer (ILST) control strategy for effective utilization and power quality as per IEEE-519 standards. Nevertheless, the design procedure of the excitation capacitor for self-excitation of the generator is also presented in detail. The design performance of SEIG is also validated through finite element method (FEM). The entire system comprising induction generator, nonlinear/linear load, and VSC along with ILST control algorithm are modeled in MATLAB/Simulink Library. The simulation performance is carried out under various operating conditions and found satisfactory. Also, the system prototype is developed in the laboratory for real-time performance analysis and validation. The results obtained are found satisfactory as per standard.
- 7 June 2020
- Published by Taylor & Francis in Energy Sources, Part A: Recovery, Utilization, and Environmental Effects
- Vol. 47 (2)
Power quality solutions for effective utilization of single-phase induction generator using voltage source converter
In this paper, the effective utilization of single-phase self-excited induction generator (SEIG) with improved power quality features with the help of voltage source converter (VSC) is presented. This generator works as an isolated single-phase distributed power generation system. In this case, the frequency and voltage control of induction generator feeding linear/nonlinear load is carried out using VSC under different operating characteristics. The power quality issues such as reactive power compensation, voltage regulation, harmonics reduction have been addressed. The VSC is operated by the reference current extracted from the distorted load current using adaptive theory-based Improved Linear Sinusoidal Tracer (ILST) control strategy for effective utilization and power quality as per IEEE-519 standards. Nevertheless, the design procedure of the excitation capacitor for self-excitation of the generator is also presented in detail. The design performance of SEIG is also validated through finite element method (FEM). The entire system comprising induction generator, nonlinear/linear load, and VSC along with ILST control algorithm are modeled in MATLAB/Simulink Library. The simulation performance is carried out under various operating conditions and found satisfactory. Also, the system prototype is developed in the laboratory for real-time performance analysis and validation. The results obtained are found satisfactory as per standard.
- 1 January 2020
- Published by Inderscience Publishers in International Journal of Power and Energy Conversion
- Vol. 11 (2) , 132
Fuel cell integration with grid using voltage source converter and its control
Due to increased burden on the grid, voltage and frequency control becomes very difficult. Moreover, nonlinear domestic appliances are also contributing towards power quality problems related with voltage and current. To share the burden of grid and for increasing the power quality at the end users authors have proposed new topology comprising fuel cell along with voltage source converter (VSC) used as distribution static compensator (DSTATCOM) connected in shunt at point of common coupling of load and source. To control the VSC, forward backward least mean square (FBLMS) algorithm is used. In this algorithm, error between desired and estimated signal is calculated in both forward and backward directions. The average error is calculated based on forward path error. Further, the active weight components and the reactive weight components are used to calculate reference source current for gate pulse generation. The complete system is simulated and validated in the laboratory environment with one prototype, the results are satisfactory.
- 1 January 2020
- Published by Inderscience Publishers in International Journal of Power and Energy Conversion
- Vol. 11 (2) , 132
Fuel cell integration with grid using voltage source converter and its control
Due to increased burden on the grid, voltage and frequency control becomes very difficult. Moreover, nonlinear domestic appliances are also contributing towards power quality problems related with voltage and current. To share the burden of grid and for increasing the power quality at the end users authors have proposed new topology comprising fuel cell along with voltage source converter (VSC) used as distribution static compensator (DSTATCOM) connected in shunt at point of common coupling of load and source. To control the VSC, forward backward least mean square (FBLMS) algorithm is used. In this algorithm, error between desired and estimated signal is calculated in both forward and backward directions. The average error is calculated based on forward path error. Further, the active weight components and the reactive weight components are used to calculate reference source current for gate pulse generation. The complete system is simulated and validated in the laboratory environment with one prototype, the results are satisfactory.
- 1 January 2020
- Published by Inderscience Publishers in International Journal of Power and Energy Conversion
- Vol. 11 (2) , 132
Fuel cell integration with grid using voltage source converter and its control
- 1 January 2020
- Published by Inderscience Publishers in International Journal of Power and Energy Conversion
- Vol. 11 (2) , 132
Fuel cell integration with grid using voltage source converter and its control
- 1 July 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Control Approach to Improve the Power Quality for Effective Utilization of Single Phase Induction Generator
This paper presents the control performance for power quality improvement thereby effective utilization of single-phase two winding self excited induction generator which is used in isolated distributed power generation system. In this paper, for off- grid application the frequency and voltage control of SEIG feeding various linear/non linear loads is carried out using Distributed Static Compensator (DSTATCOM) under different prime-mover characteristics. To address the power quality issues such as reactive power, voltage regulation and harmonics reduction etc. Moreover, adaptive theory based Improved Linear Sinusoidal Tracer (ILST) control strategy is employed to operate the DSTATCOM to accomplish the said power quality issues. In addition to it, detailed design of a capacitor which is connected across the auxiliary winding of SEIG to support the self excitation process. The complete system models developed in MATLAB environment with help of SIMULINK and SIM Power System toolbox. The performance analysis of developed model is also carried out in laboratory environment under various loading conditions for steady state and dynamical conditions.
- 1 July 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Control Approach to Improve the Power Quality for Effective Utilization of Single Phase Induction Generator
This paper presents the control performance for power quality improvement thereby effective utilization of single-phase two winding self excited induction generator which is used in isolated distributed power generation system. In this paper, for off- grid application the frequency and voltage control of SEIG feeding various linear/non linear loads is carried out using Distributed Static Compensator (DSTATCOM) under different prime-mover characteristics. To address the power quality issues such as reactive power, voltage regulation and harmonics reduction etc. Moreover, adaptive theory based Improved Linear Sinusoidal Tracer (ILST) control strategy is employed to operate the DSTATCOM to accomplish the said power quality issues. In addition to it, detailed design of a capacitor which is connected across the auxiliary winding of SEIG to support the self excitation process. The complete system models developed in MATLAB environment with help of SIMULINK and SIM Power System toolbox. The performance analysis of developed model is also carried out in laboratory environment under various loading conditions for steady state and dynamical conditions.
- 3 January 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 33 (11) , 9482-9495
Features of Power Quality in Single-Phase Distributed Power Generation Using Adaptive Nature Vectorial Filter
This paper presents the new controller for voltage and frequency control (VFC) of two winding single phase induction generator. It provides coordinated control of Battery Energy Storage System (BESS) and dump load during the mismatch of power between loads and generator using voltage and frequency control loop. It provides protection against overcharging of BESS. For this purpose Adaptive Vectorial Filter (AVF) is implemented to operate single phase induction generator in standalone mode of operation for power quality features. The unique feature of this filtering technique is its simplicity and no other analogy filters are required to produce the reconstructed signal of fundamental frequency. This procedure uses the vectorial natures of the single phase input signal which is decomposed by shifting property in the $\alpha-\beta$ orientation frame in order to get the diverse harmonic constituents. The design and analysis of AVFs for the proposed system is carried out in order to find the required performance. The proposed control method is evaluated by simulations in MATLAB/SIMULINK followed by experimental validation in laboratory for signifying its capability to execute different harmonic constituents under an extremely distorted generator current. Apart from control method, design of generator with Finite Element Method (FEM) and its electromagnetic properties are also discussed.- 3 January 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 33 (11) , 9482-9495
Features of Power Quality in Single-Phase Distributed Power Generation Using Adaptive Nature Vectorial Filter
This paper presents the new controller for voltage and frequency control (VFC) of two winding single phase induction generator. It provides coordinated control of Battery Energy Storage System (BESS) and dump load during the mismatch of power between loads and generator using voltage and frequency control loop. It provides protection against overcharging of BESS. For this purpose Adaptive Vectorial Filter (AVF) is implemented to operate single phase induction generator in standalone mode of operation for power quality features. The unique feature of this filtering technique is its simplicity and no other analogy filters are required to produce the reconstructed signal of fundamental frequency. This procedure uses the vectorial natures of the single phase input signal which is decomposed by shifting property in the $\alpha-\beta$ orientation frame in order to get the diverse harmonic constituents. The design and analysis of AVFs for the proposed system is carried out in order to find the required performance. The proposed control method is evaluated by simulations in MATLAB/SIMULINK followed by experimental validation in laboratory for signifying its capability to execute different harmonic constituents under an extremely distorted generator current. Apart from control method, design of generator with Finite Element Method (FEM) and its electromagnetic properties are also discussed.