CBChris Burns

Chris Burns

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Chris Burns has a total of 45 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    A Reference Standard for Analytical Testing of Erythropoietin

    by Huiping Tu, Kevin Carrick, Rebecca Potts, Mark Hasselberg, Mark Verdecia, Chris Burns, Ben Cowper, Fouad Atouf

    Purpose Erythropoietin (EPO) is a 165 amino acid protein that promotes the proliferation of erythrocytic progenitors. A decrease in endogenous EPO production causes anemia that can be treated with recombinant Human EPO (rHuEPO). Objective To ensure the safety and efficacy of the rHuEPO, manufacturers must use analytical methods to demonstrate similarity across batches and between different products. To do this they need reference standards to validate their equipment and methods. Method We used peptide mapping, size-exclusion chromatography, glycoprofiling, and isoelectric focusing to analyze a rHuEPO reference standard. Results Characterization demonstrates that our rHuEPO reference standard meets the criteria for quality. Conclusion The rHuEPO reference standard is fit for purpose as a tool for validating system suitability and methods.


  • Open Access

    National control laboratory independent lot testing of COVID-19 vaccines: the UK experience

    by Nicola J. Rose, Paul Stickings, Silke Schepelmann, Marc J. A. Bailey, Chris Burns

    The past 18 months have seen an unprecedented approach to vaccine development in the global effort against the COVID-19 pandemic. The process from discovery research, through clinical trials and regulatory approval often takes more than 10 years. However, the critical need to expedite vaccine availability in the pandemic has meant that new approaches to development, manufacturing, and regulation have been required: this has necessitated many stages of product development, clinical trials, and manufacturing to be undertaken in parallel at a global level. Through the development of these innovative products, the world has the best chance of finding individual, or combinations of, vaccines that will provide adequate protection for the world’s population. Despite the huge scientific and regulatory achievements and significant investment to accelerate vaccine availability, it is essential that safety measures are not compromised. Here we focus on the post regulatory approval testing by independent laboratories that provides an additional assurance of the safety and quality of a product, with an emphasis on the UK experience through the National Institute for Biological Standards and Control (NIBSC), an expert centre of the UK’s Medicines and Healthcare products Regulatory Agency (MHRA).


  • Open Access

    Establishment of a WHO Reference Reagent for anti-Mullerian hormone

    by Jackie Ferguson, Jason Hockley, Peter Rigsby, Chris Burns

    Background: There is a need for a reference material to support the development and ensure the quality of immunoassays for human AMH. A batch of ampoules, coded 16/190, containing lyophilised recombinant AMH was evaluated in a WHO Collaborative Study. The aims of the study were to determine the AMH content in terms of the calibration of each immunoassay method, to predict long-term stability and to assess the suitability of the preparation to calibrate AMH immunoassays. Methods: Study participants were asked to report the AMH content of specific dilutions of coded ampoules of 16/190 and a comparator preparation containing approximately half the AMH content. In each assay, participants also reported the AMH content of 22 patient samples to assess commutability. A robust all-laboratory geometric mean of the content estimates was determined using the laboratory geometric mean estimates. Commutability was assessed using a difference in bias approach. Stability was predicted by the measurement of thermally accelerated degradation samples. Results: Seven laboratories performed twenty-one immunoassay method-platform combinations, sixteen of which provided data which met the validity criteria, giving a consensus geometric mean estimate of AMH content of 511 ng/ampoule (95% CI, 426–612, n = 16, GCV 42%) and a robust geometric mean of 489 ng/ampoule. By contrast, the GCV% for the all-laboratory geometric mean of the relative content estimates for the comparator sample to 16/190 was 12%. Commutability was assessed using 20 of the 22 representative patient samples. Of the valid assays, 16/190 was within the limits of acceptable commutability for 6 methods, partially commutable for a further 3 methods and non-commutable when measured by 7 methods. The preparation was predicted to be highly stable when stored at − 20 °C. Conclusion: The majority of methods met the validity criteria. Content estimates showed a high between-method variability, yet assays exhibited a similar proportionality of response as demonstrated using the comparator sample. 16/190 was commutable in some but not all methods. On the basis of these results, it was agreed by the WHO Expert Committee on Biological Standardization to establish 16/190 as a WHO Reference Reagent for AMH with a content defined by consensus immunoassay of 489 ng/ampoule.


  • Open Access

    IFCC Working Group Recommendations for Correction of Bias Caused by Noncommutability of a Certified Reference Material Used in the Calibration Hierarchy of an End-User Measurement Procedure

    by W Greg Miller, Jeffrey Budd, Neil Greenberg, Cas Weykamp, Harald Althaus, Heinz Schimmel, Mauro Panteghini, Vincent Delatour, Ferruccio Ceriotti, Thomas Keller, et al.

    Establishing metrological traceability to an assigned value of a matrix-based certified reference material (CRM) that has been validated to be commutable among available end-user measurement procedures (MPs) is central to producing equivalent results for the measurand in clinical samples (CSs) irrespective of the clinical laboratory MPs used. When a CRM is not commutable with CSs, the bias due to noncommutability will be propagated to the CS results causing incorrect metrological traceability to the CRM and nonequivalent CS results among different MPs. In a commutability assessment, a conclusion that a CRM is commutable or noncommutable for use with a specific MP is made when the difference in bias between the CRM and CSs meets or does not meet a criterion for that specific MP when compared to other MPs. A conclusion regarding commutability or noncommutability requires that the magnitude of the difference in bias observed in the commutability assessment remains unchanged over time. This conclusion requires the CRM to be stable and no substantive changes in the MPs. These conditions should be periodically reverified. If an available CRM is determined to be noncommutable for a specific MP, that CRM can be used in the calibration hierarchy for that MP when an appropriately validated MP-specific correction for the noncommutability bias is included. We describe with examples how a MP-specific correction and its uncertainty can be developed and applied in a calibration hierarchy to achieve metrological traceability of results for CSs to the CRM’s assigned value.


  • Open Access

    Applying the science of measurement to biology: Why bother?

    by Carmen H. Coxon, Colin Longstaff, Chris Burns

    Both basic and translational research are continuously evolving, but the principles that underpin research integrity remain constant. These include rational, hypothesis-driven, and adequately planned and controlled science, which is carried out openly, honestly, and ethically. An important component of this should be minimising experimental irreproducibility. Biological systems, in particular, are inherently variable due to the nature of cells and tissues, as well as the complex molecules within them. As a result, it is important to understand and identify sources of variability and to strive to minimise their influence. In many instances, the application of metrology (the science of measurement) can play an important role in ensuring good quality research, even within biological systems that aren’t always amenable to many of the metrological concepts applied in other fields. Here, we introduce the basic concepts of metrology in relation to biological systems and promote the application of these principles to help avoid potentially costly mistakes in both basic and translational research. We also call on funders to encourage the uptake of metrological principles, as well as provide funding and support for later engagement with regulatory bodies.


  • Open Access

    Concise Review: Exploring Immunomodulatory Features of Mesenchymal Stromal Cells in Humanized Mouse Models

    by Vera J. Mehler, Chris J. Burns, Melanie L. Moore

    With their immunosuppressive features, human mesenchymal stromal cells (MSCs), sometimes also termed as mesenchymal stem cells, hold great potential as a cell-based therapy for various immune-mediated diseases. Indeed, MSCs have already been approved as a treatment for graft versus host disease. However, contradictory data from clinical trials and lack of conclusive proof of efficacy hinder the progress toward wider clinical use of MSCs and highlight the need for more relevant disease models. Humanized mice are increasingly used as models to study immune-mediated disease, as they simulate human immunobiology more closely than conventional murine models. With further advances in their resemblance to human immunobiology, it is very likely that humanized mice will be used more commonly as models to investigate MSCs with regard to their therapeutic safety and their immunomodulatory effect and its underlying mechanisms. Recent studies that explore the immunosuppressive features of MSCs in humanized mouse models will be discussed in this review. Stem Cells 2019;37:298–305


  • Open Access

    Pregnancy rates after vitrification, warming and transfer of equine embryos

    by G Araujo, An Rocha Filho, Stephen F. Burns, Chris Burns, Carla Fredrichsen Moya, Cezinande de Meira