Emily Russell
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Emily Russell has a total of 35 co-authors. Here are the top co-authors by number of shared publications:
Ben Russell
National Physical Laboratory, London, UK
3 shared publicationsGiuseppe Schettino
National Physical Laboratory, London, UK
3 shared publicationsHibaaq Mohamud
National Physical Laboratory, London, UK
3 shared publicationsBashar Al-Qaisieh
Leeds Teaching Hospitals NHS Trust, Leeds, UK
2 shared publicationsChristopher O’hAra
Leeds Teaching Hospitals NHS Trust, Leeds, UK
2 shared publicationsConor K. McGarry
Patrick G. Johnston Centre for Cancer Research, Queen’s University, Belfast, UK
2 shared publications
Latest Publications
- 29 April 2026
- Published by Oxford University Press (OUP) in British Journal of Radiology
- Vol. 99 (1184) , 1538-1540
Cardiac devices audit evaluating the use of 6 MV FFF beams following updated Radiotherapy Board guidance
Objectives: Following guidance from the Radiotherapy Board for radiotherapy of patients with cardiac implantable electronic devices (CIED), a local audit of retrospective patient treatments was carried out. The guidance includes recommendations to avoid direct irradiation of the devices and the avoidance of Flattening Filter Free (FFF) beams due to the high dose rates associated with FFF beams, leading to higher risk of device malfunction. Methods: Linac dose-rates were measured by noting the dose rate of the linac whilst delivering 6 MV FFF treatment plans, the local standard energy used for Volumetric Modulated Arc Therapy (VMAT). Plans were also assessed to determine whether treatment beams traveled through the CIED. Results: It was found that 1 out of 540 patients with CIEDs was treated with the CIED receiving a dose rate above 8 Gy/minute for a 6 MV FFF beam. The plan for this treatment did not have the “protect function” for CIEDs, which is now standard planning practice. Conclusions: The dose rate when using 6 MV FFF beams is sufficiently reduced, and therefore we have confidence in our current practice for the protection of patients with CIEDs. Advances in knowledge: This technical note responds to recent guidance published on the safety of radiotherapy exposures for patients with cardiac devices. It audits the standard practices in a large NHS Trust, assessing whether these standard practices align with the guidance. This will be of interest to many other trusts aspiring to adhere to this guidance.
- 29 April 2026
- Published by Oxford University Press (OUP) in British Journal of Radiology
- Vol. 99 (1184) , 1538-1540
Cardiac devices audit evaluating the use of 6 MV FFF beams following updated Radiotherapy Board guidance
Objectives: Following guidance from the Radiotherapy Board for radiotherapy of patients with cardiac implantable electronic devices (CIED), a local audit of retrospective patient treatments was carried out. The guidance includes recommendations to avoid direct irradiation of the devices and the avoidance of Flattening Filter Free (FFF) beams due to the high dose rates associated with FFF beams, leading to higher risk of device malfunction. Methods: Linac dose-rates were measured by noting the dose rate of the linac whilst delivering 6 MV FFF treatment plans, the local standard energy used for Volumetric Modulated Arc Therapy (VMAT). Plans were also assessed to determine whether treatment beams traveled through the CIED. Results: It was found that 1 out of 540 patients with CIEDs was treated with the CIED receiving a dose rate above 8 Gy/minute for a 6 MV FFF beam. The plan for this treatment did not have the “protect function” for CIEDs, which is now standard planning practice. Conclusions: The dose rate when using 6 MV FFF beams is sufficiently reduced, and therefore we have confidence in our current practice for the protection of patients with CIEDs. Advances in knowledge: This technical note responds to recent guidance published on the safety of radiotherapy exposures for patients with cardiac devices. It audits the standard practices in a large NHS Trust, assessing whether these standard practices align with the guidance. This will be of interest to many other trusts aspiring to adhere to this guidance.
- Open Access
- 31 March 2025
- Published by Cambridge University Press (CUP) in Journal of Radiotherapy in Practice
- Vol. 24, e14
An automated cone-beam CT dosimetric assessment pipeline for adaptive head and neck radiotherapy
Background and purpose: Adaptive radiotherapy (ART) is commonly used to mitigate effects of anatomical change during head and neck (H&N) radiotherapy. The process of identifying patients for ART can be subjective and resource-intensive. This feasibility project aims to design and validate a pipeline to automate the process and use it to assess the current clinical pathway for H&N treatments. Methods: The pipeline analysed patients’ on-set cone-beam CT (CBCT) scans to identify inter-fractional anatomical changes. CBCTs were converted into synthetic CTs, contours were automatically generated, and the original plan was recomputed. Each synthetic CT was evaluated against a set of dosimetric goals, with failed goals causing an ART recommendation. To validate pipeline performance, a ‘gold standard’ was synthesised by recomputing patients’ original plans on a rescan-CT acquired during treatment and identifying failed clinical goals. The pipeline sensitivity and specificity compared to this ‘gold standard’ were calculated for 12 ART patients. The pipeline was then run on a cohort of 12 ART and 14 non-ART patients, and its sensitivity and specificity were instead calculated against the clinical decision made. Results: The pipeline showed good agreement with the synthesised ‘gold standard’ with an optimum sensitivity of 0·83 and specificity of 0·67. When run over a cohort containing both ART and non-ART patients and assessed against the subjective clinical decision made, the pipeline showed no predictive power (sensitivity: 0·58, specificity: 0·47). Conclusions: Good agreement with the ‘gold standard’ gives confidence in pipeline performance and disagreement with clinical decisions implies implementation could help standardise the current clinical pathway.
- 31 March 2025
- Published by Cambridge University Press (CUP) in Journal of Radiotherapy in Practice
- Vol. 24, e14
Open AccessAn automated cone-beam CT dosimetric assessment pipeline for adaptive head and neck radiotherapy
Background and purpose: Adaptive radiotherapy (ART) is commonly used to mitigate effects of anatomical change during head and neck (H&N) radiotherapy. The process of identifying patients for ART can be subjective and resource-intensive. This feasibility project aims to design and validate a pipeline to automate the process and use it to assess the current clinical pathway for H&N treatments. Methods: The pipeline analysed patients’ on-set cone-beam CT (CBCT) scans to identify inter-fractional anatomical changes. CBCTs were converted into synthetic CTs, contours were automatically generated, and the original plan was recomputed. Each synthetic CT was evaluated against a set of dosimetric goals, with failed goals causing an ART recommendation. To validate pipeline performance, a ‘gold standard’ was synthesised by recomputing patients’ original plans on a rescan-CT acquired during treatment and identifying failed clinical goals. The pipeline sensitivity and specificity compared to this ‘gold standard’ were calculated for 12 ART patients. The pipeline was then run on a cohort of 12 ART and 14 non-ART patients, and its sensitivity and specificity were instead calculated against the clinical decision made. Results: The pipeline showed good agreement with the synthesised ‘gold standard’ with an optimum sensitivity of 0·83 and specificity of 0·67. When run over a cohort containing both ART and non-ART patients and assessed against the subjective clinical decision made, the pipeline showed no predictive power (sensitivity: 0·58, specificity: 0·47). Conclusions: Good agreement with the ‘gold standard’ gives confidence in pipeline performance and disagreement with clinical decisions implies implementation could help standardise the current clinical pathway.
- Open Access
- 9 December 2024
- Published by Cambridge University Press (CUP) in Journal of Radiotherapy in Practice
- Vol. 23, e29
An automated assessment pipeline to identify prostate treatments that need adaptive radiotherapy
Background and purpose: This project developed and validated an automated pipeline for prostate treatments to accurately determine which patients could benefit from adaptive radiotherapy (ART) using synthetic CTs (sCTs) generated from on-treatment cone-beam CT (CBCT) images. Materials and methods: The automated pipeline converted CBCTs to sCTs utilising deep-learning, for accurate dose recalculation. Deformable image registration mapped contours from the planning CT to the sCT, with the treatment plan recalculated. A pass/fail assessment used relevant clinical goals. A fail threshold indicated ART was required. All acquired CBCTs (230 sCTs) for 31 patients (6 who had ART) were assessed for pipeline accuracy and clinical viability, comparing clinical outcomes to pipeline outcomes. Results: The pipeline distinguished patients requiring ART; 74·4% of sCTs for ART patients were red (failure) results, compared to 6·4% of non-ART sCTs. The receiver operator characteristic area under curve was 0·98, demonstrating high performance. The automated pipeline was statistically significantly (p < 0·05) quicker than the current clinical assessment methods (182·5s and 556·4s, respectively), and deformed contour accuracy was acceptable, with 96·6% of deformed clinical target volumes (CTVs) clinically acceptable. Conclusion: The automated pipeline identified patients who required ART with high accuracy while reducing time and resource requirements. This could reduce departmental workload and increase efficiency and personalisation of patient treatments. Further work aims to apply the pipeline to other treatment sites and investigate its potential for taking into account dose accumulation.
- 9 December 2024
- Published by Cambridge University Press (CUP) in Journal of Radiotherapy in Practice
- Vol. 23, e29
Open AccessAn automated assessment pipeline to identify prostate treatments that need adaptive radiotherapy
Background and purpose: This project developed and validated an automated pipeline for prostate treatments to accurately determine which patients could benefit from adaptive radiotherapy (ART) using synthetic CTs (sCTs) generated from on-treatment cone-beam CT (CBCT) images. Materials and methods: The automated pipeline converted CBCTs to sCTs utilising deep-learning, for accurate dose recalculation. Deformable image registration mapped contours from the planning CT to the sCT, with the treatment plan recalculated. A pass/fail assessment used relevant clinical goals. A fail threshold indicated ART was required. All acquired CBCTs (230 sCTs) for 31 patients (6 who had ART) were assessed for pipeline accuracy and clinical viability, comparing clinical outcomes to pipeline outcomes. Results: The pipeline distinguished patients requiring ART; 74·4% of sCTs for ART patients were red (failure) results, compared to 6·4% of non-ART sCTs. The receiver operator characteristic area under curve was 0·98, demonstrating high performance. The automated pipeline was statistically significantly (p < 0·05) quicker than the current clinical assessment methods (182·5s and 556·4s, respectively), and deformed contour accuracy was acceptable, with 96·6% of deformed clinical target volumes (CTVs) clinically acceptable. Conclusion: The automated pipeline identified patients who required ART with high accuracy while reducing time and resource requirements. This could reduce departmental workload and increase efficiency and personalisation of patient treatments. Further work aims to apply the pipeline to other treatment sites and investigate its potential for taking into account dose accumulation.
- Open Access
- 12 June 2021
- Published by Springer Nature in Radiation Oncology
- Vol. 16 (1) , 1-16
Impact of superparamagnetic iron oxide nanoparticles on in vitro and in vivo radiosensitisation of cancer cells
Purpose: The recent implementation of MR-Linacs has highlighted theranostic opportunities of contrast agents in both imaging and radiotherapy. There is a lack of data exploring the potential of superparamagnetic iron oxide nanoparticles (SPIONs) as radiosensitisers. Through preclinical 225 kVp exposures, this study aimed to characterise the uptake and radiobiological effects of SPIONs in tumour cell models in vitro and to provide proof-of-principle application in a xenograft tumour model. Methods: SPIONs were also characterised to determine their hydrodynamic radius using dynamic light scattering and uptake was measured using ICP-MS in 6 cancer cell lines; H460, MiaPaCa2, DU145, MCF7, U87 and HEPG2. The impact of SPIONs on radiobiological response was determined by measuring DNA damage using 53BP1 immunofluorescence and cell survival. Sensitisation Enhancement Ratios (SERs) were compared with the predicted Dose Enhancement Ratios (DEFs) based on physical absorption estimations. In vivo efficacy was demonstrated using a subcutaneous H460 xenograft tumour model in SCID mice by following intra-tumoural injection of SPIONs. Results: The hydrodynamic radius was found to be between 110 and 130 nm, with evidence of being monodisperse in nature. SPIONs significantly increased DNA damage in all cell lines with the exception of U87 cells at a dose of 1 Gy, 1 h post-irradiation. Levels of DNA damage correlated with the cell survival, in which all cell lines except U87 cells showed an increased sensitivity (P < 0.05) in the linear quadratic curve fit for 1 h exposure to 23.5 μg/ml SPIONs. There was also a 30.1% increase in the number of DNA damage foci found for HEPG2 cells at 2 Gy. No strong correlation was found between SPION uptake and DNA damage at any dose, yet the biological consequences of SPIONs on radiosensitisation were found to be much greater, with SERs up to 1.28 ± 0.03, compared with predicted physical dose enhancement levels of 1.0001. In vivo, intra-tumoural injection of SPIONs combined with radiation showed significant tumour growth delay compared to animals treated with radiation or SPIONs alone (P < 0.05). Conclusions: SPIONs showed radiosensitising effects in 5 out of 6 cancer cell lines. No correlation was found between the cell-specific uptake of SPIONs into the cells and DNA damage levels. The in vivo study found a significant decrease in the tumour growth rate.
- 12 June 2021
- Published by Springer Nature in Radiation Oncology
- Vol. 16 (1) , 1-16
Open AccessImpact of superparamagnetic iron oxide nanoparticles on in vitro and in vivo radiosensitisation of cancer cells
Purpose: The recent implementation of MR-Linacs has highlighted theranostic opportunities of contrast agents in both imaging and radiotherapy. There is a lack of data exploring the potential of superparamagnetic iron oxide nanoparticles (SPIONs) as radiosensitisers. Through preclinical 225 kVp exposures, this study aimed to characterise the uptake and radiobiological effects of SPIONs in tumour cell models in vitro and to provide proof-of-principle application in a xenograft tumour model. Methods: SPIONs were also characterised to determine their hydrodynamic radius using dynamic light scattering and uptake was measured using ICP-MS in 6 cancer cell lines; H460, MiaPaCa2, DU145, MCF7, U87 and HEPG2. The impact of SPIONs on radiobiological response was determined by measuring DNA damage using 53BP1 immunofluorescence and cell survival. Sensitisation Enhancement Ratios (SERs) were compared with the predicted Dose Enhancement Ratios (DEFs) based on physical absorption estimations. In vivo efficacy was demonstrated using a subcutaneous H460 xenograft tumour model in SCID mice by following intra-tumoural injection of SPIONs. Results: The hydrodynamic radius was found to be between 110 and 130 nm, with evidence of being monodisperse in nature. SPIONs significantly increased DNA damage in all cell lines with the exception of U87 cells at a dose of 1 Gy, 1 h post-irradiation. Levels of DNA damage correlated with the cell survival, in which all cell lines except U87 cells showed an increased sensitivity (P < 0.05) in the linear quadratic curve fit for 1 h exposure to 23.5 μg/ml SPIONs. There was also a 30.1% increase in the number of DNA damage foci found for HEPG2 cells at 2 Gy. No strong correlation was found between SPION uptake and DNA damage at any dose, yet the biological consequences of SPIONs on radiosensitisation were found to be much greater, with SERs up to 1.28 ± 0.03, compared with predicted physical dose enhancement levels of 1.0001. In vivo, intra-tumoural injection of SPIONs combined with radiation showed significant tumour growth delay compared to animals treated with radiation or SPIONs alone (P < 0.05). Conclusions: SPIONs showed radiosensitising effects in 5 out of 6 cancer cell lines. No correlation was found between the cell-specific uptake of SPIONs into the cells and DNA damage levels. The in vivo study found a significant decrease in the tumour growth rate.
- Open Access
- 28 October 2020
- Published by Springer Nature in Research Square
Impact of Superparamagnetic Iron Oxide Nanoparticles on In Vitro and In Vivo Radiosensitisation of Cancer Cells
PurposeThe recent implementation of MR-Linacs has highlighted theranostic opportunities of contrast agents in both imaging and radiotherapy. There is a lack of data exploring the potential of superparamagnetic iron oxide nanoparticles (SPIONs) as radiosensitisers. This study aimed to characterise the uptake and radiobiological effects of SPIONs in tumour cell models in vitro and to provide proof-of-principle application in a xenograft tumour model. MethodsSPION uptake was measured using ICP-MS in 6 cancer cell lines; H460, MiaPaCa2, DU145, MCF7, U87 and HEPG2. The impact of SPIONs on radiobiological response was determined by measuring DNA damage using 53BP1 immunofluorescence and cell survival. Measured dose enhancement factors (DEFs) were with the predicted DEFs based on physical absorption estimations. In vivo efficacy was demonstrated using a subcutaneous H460 xenograft tumour model in SCID mice by following intra-tumoural injection of SPIONs. ResultsSPIONs significantly increased DNA damage in all cell lines with the exception of U87 cells at a dose of 1 Gy, 1 hr post-irradiation. Levels of DNA damage correlated with the cell survival, in which all cell lines except U87 cells showed an increased sensitivity (P < 0.05) in the linear quadratic curve fit for 1 hr exposure to 0.1 mM SPIONs. There was also a 30.1 % increase in the number of DNA damage foci found for HEPG2 cells at 2 Gy. No strong correlation was found between SPION uptake and DNA damage at any dose, yet the biological consequences of SPIONs on radiosensitisation were found to be much greater, with DEFs up to 1.28 ± 0.03, compared with predicted physical dose enhancement levels of 1.0001. In vivo, intra-tumoural injection of SPIONs combined with radiation showed significant tumour growth delay compared to animals treated with radiation or SPIONs alone (p < 0.05). ConclusionsSPIONs showed radiosensitising effects in 5 out of 6 cancer cell lines. No correlation was found between the cell-specific uptake of SPIONs into the cells and DNA damage levels. The in vivo study found a significant decrease in the tumour growth rate.
- 28 October 2020
- Published by Springer Nature in Research Square
Open AccessImpact of Superparamagnetic Iron Oxide Nanoparticles on In Vitro and In Vivo Radiosensitisation of Cancer Cells
PurposeThe recent implementation of MR-Linacs has highlighted theranostic opportunities of contrast agents in both imaging and radiotherapy. There is a lack of data exploring the potential of superparamagnetic iron oxide nanoparticles (SPIONs) as radiosensitisers. This study aimed to characterise the uptake and radiobiological effects of SPIONs in tumour cell models in vitro and to provide proof-of-principle application in a xenograft tumour model. MethodsSPION uptake was measured using ICP-MS in 6 cancer cell lines; H460, MiaPaCa2, DU145, MCF7, U87 and HEPG2. The impact of SPIONs on radiobiological response was determined by measuring DNA damage using 53BP1 immunofluorescence and cell survival. Measured dose enhancement factors (DEFs) were with the predicted DEFs based on physical absorption estimations. In vivo efficacy was demonstrated using a subcutaneous H460 xenograft tumour model in SCID mice by following intra-tumoural injection of SPIONs. ResultsSPIONs significantly increased DNA damage in all cell lines with the exception of U87 cells at a dose of 1 Gy, 1 hr post-irradiation. Levels of DNA damage correlated with the cell survival, in which all cell lines except U87 cells showed an increased sensitivity (P < 0.05) in the linear quadratic curve fit for 1 hr exposure to 0.1 mM SPIONs. There was also a 30.1 % increase in the number of DNA damage foci found for HEPG2 cells at 2 Gy. No strong correlation was found between SPION uptake and DNA damage at any dose, yet the biological consequences of SPIONs on radiosensitisation were found to be much greater, with DEFs up to 1.28 ± 0.03, compared with predicted physical dose enhancement levels of 1.0001. In vivo, intra-tumoural injection of SPIONs combined with radiation showed significant tumour growth delay compared to animals treated with radiation or SPIONs alone (p < 0.05). ConclusionsSPIONs showed radiosensitising effects in 5 out of 6 cancer cell lines. No correlation was found between the cell-specific uptake of SPIONs into the cells and DNA damage levels. The in vivo study found a significant decrease in the tumour growth rate.
- 3 August 2020
- Published by Radiation Research Society in Radiation Research
- Vol. 194 (3) , 298-309
Effects of Gadolinium MRI Contrast Agents on DNA Damage and Cell Survival when Used in Combination with Radiation
Gadolinium is a commonly used contrast agent for magnetic resonance imaging (MRI). The goal of this work was to determine how MRI contrast agents affect radiosensitivity for tumour cells. Using a 225kVp X-ray cabinet source, immunofluorescence and clonogenic assays were performed on six cancer cell lines: lung (H460), pancreas (MiaPaCa2), prostate (DU145), breast (MCF7), brain (U87) and liver (HEPG2). Dotarem® contrast agent, at concentrations of 0.2, 2 and 20 mM, was used to determine its effect on DNA damage and cell survival. Measurements were performed using inductively coupled plasma mass spectrometry (ICP-MS) to determine the amount of gadolinium taken up by each cell line for each concentration. A statistically significant increase in DNA damage was seen for all cell lines at a dose of 1 Gy for concentrations of 2 and 20 mM, at 1 h postirradiation. At 24 h postirradiation, most of the DNA damage had been repaired, with approximately 90% repair for almost all doses of radiation and concentrations of Dotarem. Clonogenic results showed no statistically significant decrease in cell survival for any cell line or concentration. Uptake measurements showed cell line-specific variations in uptake, with MCF7 and HEPG2 cells having a high percentage uptake compared to other cell lines, with 151.4 ± 0.3 × 10–15 g and 194.8 ± 0.4 × 10–15 g per cell, respectively, at 2 mM Dotarem concentration. In this work, a variability in gadolinium uptake was observed between cell lines. A significant increase was seen in initial levels of DNA damage after 1 Gy irradiation for all six cancer cell lines; however, no significant decrease in cell survival was seen with the clonogenic assay. The observation of high levels of repair suggest that while initial levels of DNA damage are increased, this damage is almost entirely repaired within 24 h, and does not affect the ability of cells to survive and produce colonies.
- 3 August 2020
- Published by Radiation Research Society in Radiation Research
- Vol. 194 (3) , 298-309
Effects of Gadolinium MRI Contrast Agents on DNA Damage and Cell Survival when Used in Combination with Radiation
Gadolinium is a commonly used contrast agent for magnetic resonance imaging (MRI). The goal of this work was to determine how MRI contrast agents affect radiosensitivity for tumour cells. Using a 225kVp X-ray cabinet source, immunofluorescence and clonogenic assays were performed on six cancer cell lines: lung (H460), pancreas (MiaPaCa2), prostate (DU145), breast (MCF7), brain (U87) and liver (HEPG2). Dotarem® contrast agent, at concentrations of 0.2, 2 and 20 mM, was used to determine its effect on DNA damage and cell survival. Measurements were performed using inductively coupled plasma mass spectrometry (ICP-MS) to determine the amount of gadolinium taken up by each cell line for each concentration. A statistically significant increase in DNA damage was seen for all cell lines at a dose of 1 Gy for concentrations of 2 and 20 mM, at 1 h postirradiation. At 24 h postirradiation, most of the DNA damage had been repaired, with approximately 90% repair for almost all doses of radiation and concentrations of Dotarem. Clonogenic results showed no statistically significant decrease in cell survival for any cell line or concentration. Uptake measurements showed cell line-specific variations in uptake, with MCF7 and HEPG2 cells having a high percentage uptake compared to other cell lines, with 151.4 ± 0.3 × 10–15 g and 194.8 ± 0.4 × 10–15 g per cell, respectively, at 2 mM Dotarem concentration. In this work, a variability in gadolinium uptake was observed between cell lines. A significant increase was seen in initial levels of DNA damage after 1 Gy irradiation for all six cancer cell lines; however, no significant decrease in cell survival was seen with the clonogenic assay. The observation of high levels of repair suggest that while initial levels of DNA damage are increased, this damage is almost entirely repaired within 24 h, and does not affect the ability of cells to survive and produce colonies.
- Open Access
- 26 December 2019
- Published by Springer Nature in Radiation Oncology
- Vol. 14 (1) , 1-13
Fiducial markers visibility and artefacts in prostate cancer radiotherapy multi-modality imaging
Background: In this study, a novel pelvic phantom was developed and used to assess the visibility and presence of artefacts from different types of commercial fiducial markers (FMs) on multi-modality imaging relevant to prostate cancer.Methods and materials: The phantom was designed with 3D printed hollow cubes in the centre. These cubes were filled with gel to mimic the prostate gland and two parallel PVC rods were used to mimic bones in the pelvic region. Each cube was filled with gelatine and three unique FMs were positioned with a clinically-relevant spatial distribution. The FMs investigated were; Gold Marker (GM) CIVCO, GM RiverPoint, GM Gold Anchor (GA) line and ball shape, and polymer marker (PM) from CIVCO. The phantom was scanned using several imaging modalities typically used to image prostate cancer patients; MRI, CT, CBCT, planar kV-pair, ExacTrac, 6MV, 2.5MV and integrated EPID imaging. The visibility of the markers and any observed artefacts in the phantom were compared to in-vivo scans of prostate cancer patients with FMs.Results: All GMs were visible in volumetric scans, however, they also had the most visible artefacts on CT and CBCT scans, with the magnitude of artefacts increasing with FM size. PM FMs had the least visible artefacts in volumetric scans but they were not visible on portal images and had poor visibility on lateral kV images. The smallest diameter GMs (GA) were the most difficult GMs to identify on lateral kV images.Conclusion: The choice between different FMs is also dependent on the adopted IGRT strategy. PM was found to be superior to investigated gold markers in the most commonly used modalities in the management of prostate cancer; CT, CBCT and MRI imaging.
- 26 December 2019
- Published by Springer Nature in Radiation Oncology
- Vol. 14 (1) , 1-13
Open AccessFiducial markers visibility and artefacts in prostate cancer radiotherapy multi-modality imaging
Background: In this study, a novel pelvic phantom was developed and used to assess the visibility and presence of artefacts from different types of commercial fiducial markers (FMs) on multi-modality imaging relevant to prostate cancer.Methods and materials: The phantom was designed with 3D printed hollow cubes in the centre. These cubes were filled with gel to mimic the prostate gland and two parallel PVC rods were used to mimic bones in the pelvic region. Each cube was filled with gelatine and three unique FMs were positioned with a clinically-relevant spatial distribution. The FMs investigated were; Gold Marker (GM) CIVCO, GM RiverPoint, GM Gold Anchor (GA) line and ball shape, and polymer marker (PM) from CIVCO. The phantom was scanned using several imaging modalities typically used to image prostate cancer patients; MRI, CT, CBCT, planar kV-pair, ExacTrac, 6MV, 2.5MV and integrated EPID imaging. The visibility of the markers and any observed artefacts in the phantom were compared to in-vivo scans of prostate cancer patients with FMs.Results: All GMs were visible in volumetric scans, however, they also had the most visible artefacts on CT and CBCT scans, with the magnitude of artefacts increasing with FM size. PM FMs had the least visible artefacts in volumetric scans but they were not visible on portal images and had poor visibility on lateral kV images. The smallest diameter GMs (GA) were the most difficult GMs to identify on lateral kV images.Conclusion: The choice between different FMs is also dependent on the adopted IGRT strategy. PM was found to be superior to investigated gold markers in the most commonly used modalities in the management of prostate cancer; CT, CBCT and MRI imaging.