Leandro Andrade Holgado
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Interests
Leandro Andrade Holgado has a total of 37 co-authors. Here are the top co-authors by number of shared publications:
- Angela Kinoshita
Pro-Rectory of Research and Graduate Studies, University of Western São Paulo—UNOESTE, Presidente Prudente 19065-175, Brazil
5 shared publications - Mariza Akemi Matsumoto
Department of Basic Sciences, São Paulo State University - Unesp, Araçatuba School of Dentistry, São Paulo, Brazil
4 shared publications - Carlos Frederico Oliveira Graeff
São Paulo State University (UNESP)
3 shared publications Hugo Nary Filho
3 shared publicationsLeonardo Marques
Universidade Sagrado Coração
3 shared publications- Daniel Araki Ribeiro
Department of Biosciences Institute of Health and Society, Federal University of São Paulo, UNIFESP Santos São Paulo Brazil
2 shared publications
Latest Publications
- Open Access
- 31 July 2023
- Published by Brazilian Journals in Revista Contemporânea
- Vol. 3 (8) , 11428-11445
CORONECTOMIA: UMA REVISÃO DE LITERATURA COM ÊNFASE EM TERCEIROS MOLARES INFERIORES
A exodontia dos terceiros molares é um dos procedimentos cirúrgicos mais comuns na odontologia. Em situações de indicação cirúrgica, entretanto com riscos previsíveis das complicações, como parestesia no nervo alveolar inferior, foi descrita uma técnica alternativa chamada de coronectomia. Ela consiste na remoção da coroa do dente e sepultamento das raízes. A técnica de coronectomia vem sido muito discutida como um tratamento alternativo para a extração de terceiros molares inferiores inclusos, com resultados promissores e desejáveis. Frente o contexto exposto, ainda há dúvidas entre os clínicos sobre o grau de previsibilidade de sucesso que o procedimento de coronectomia proporciona. Seria segura a sua indicação como resolução clínica de um terceiro molar inferior impactado? Este trabalho teve como objetivo responder esse questionamento por meio de uma revisão de literatura. A busca de trabalhos do tema foi conduzida utilizando os termos “coronectomy” e “third molar”, selecionando somente trabalhos dos últimos dez anos, com ênfase nos artigos de revisão sistemática. Foram incluídos somente 13 artigos disponíveis para leitura, que se referem a eficácia e segurança da técnica avaliada, em língua inglesa. A partir deste estudo pode ser concluído que: a coronectomia é uma técnica alternativa eficiente e segura para os terceiros molares inferiores quando há risco de lesão ao nervo alveolar inferior; existem variações relatadas na técnica, mas elas não parecem afetar os resultados; a migração da raiz, após a coronectomia parece ser a complicação mais frequente, entretanto não resulta em consequências funcionais ou sensoriais. Por fim, faltam estudos clínicos demonstrando resultados a longo prazo.
- 31 July 2023
- Published by Brazilian Journals in Revista Contemporânea
- Vol. 3 (8) , 11428-11445
Open AccessCORONECTOMIA: UMA REVISÃO DE LITERATURA COM ÊNFASE EM TERCEIROS MOLARES INFERIORES
A exodontia dos terceiros molares é um dos procedimentos cirúrgicos mais comuns na odontologia. Em situações de indicação cirúrgica, entretanto com riscos previsíveis das complicações, como parestesia no nervo alveolar inferior, foi descrita uma técnica alternativa chamada de coronectomia. Ela consiste na remoção da coroa do dente e sepultamento das raízes. A técnica de coronectomia vem sido muito discutida como um tratamento alternativo para a extração de terceiros molares inferiores inclusos, com resultados promissores e desejáveis. Frente o contexto exposto, ainda há dúvidas entre os clínicos sobre o grau de previsibilidade de sucesso que o procedimento de coronectomia proporciona. Seria segura a sua indicação como resolução clínica de um terceiro molar inferior impactado? Este trabalho teve como objetivo responder esse questionamento por meio de uma revisão de literatura. A busca de trabalhos do tema foi conduzida utilizando os termos “coronectomy” e “third molar”, selecionando somente trabalhos dos últimos dez anos, com ênfase nos artigos de revisão sistemática. Foram incluídos somente 13 artigos disponíveis para leitura, que se referem a eficácia e segurança da técnica avaliada, em língua inglesa. A partir deste estudo pode ser concluído que: a coronectomia é uma técnica alternativa eficiente e segura para os terceiros molares inferiores quando há risco de lesão ao nervo alveolar inferior; existem variações relatadas na técnica, mas elas não parecem afetar os resultados; a migração da raiz, após a coronectomia parece ser a complicação mais frequente, entretanto não resulta em consequências funcionais ou sensoriais. Por fim, faltam estudos clínicos demonstrando resultados a longo prazo.
- Open Access
Vertical Guided Bone Augmentation Using Titanium Mesh Domes Coated with Natural Latex Extracted from Hevea brasiliensis
The subject of this work is the evaluation of the use of titanium mesh domes coated with latex extracted from Hevea brasiliensis to promote vertical guided bone augmentation (GBA), above the normal limits of the skeleton. Twenty-four New Zealand rabbits were used, in which a circular groove of eight millimeters in diameter and nine holes in the internal region reaching the medulla were made with a trephine drill, in the calvaria. The dome, four millimeters in height, was fixed above this defect. The animals were divided into four groups (N = 6). The first (control) received a titanium dome not covered by the periosteum, and the second received a titanium dome that was covered by the periosteum. For the third, a dome with a latex coating was used and was not covered by the periosteum, and for the fourth, a titanium dome with a latex coating was used and was covered by the periosteum. After 90 days, the animals were euthanized. Computerized tomography imaging demonstrated that vertical bone augmentation was achieved in the groups with titanium domes coated with latex. Microscopic evaluation showed that there were no differences between the control group and Group 2, or between Groups 3 and 4. The other comparisons showed statistically significant differences (p < 0.05, ANOVA-Tukey).
Open AccessVertical Guided Bone Augmentation Using Titanium Mesh Domes Coated with Natural Latex Extracted from Hevea brasiliensis
The subject of this work is the evaluation of the use of titanium mesh domes coated with latex extracted from Hevea brasiliensis to promote vertical guided bone augmentation (GBA), above the normal limits of the skeleton. Twenty-four New Zealand rabbits were used, in which a circular groove of eight millimeters in diameter and nine holes in the internal region reaching the medulla were made with a trephine drill, in the calvaria. The dome, four millimeters in height, was fixed above this defect. The animals were divided into four groups (N = 6). The first (control) received a titanium dome not covered by the periosteum, and the second received a titanium dome that was covered by the periosteum. For the third, a dome with a latex coating was used and was not covered by the periosteum, and for the fourth, a titanium dome with a latex coating was used and was covered by the periosteum. After 90 days, the animals were euthanized. Computerized tomography imaging demonstrated that vertical bone augmentation was achieved in the groups with titanium domes coated with latex. Microscopic evaluation showed that there were no differences between the control group and Group 2, or between Groups 3 and 4. The other comparisons showed statistically significant differences (p < 0.05, ANOVA-Tukey).
- 11 April 2018
- Published by Wiley in Journal of Biomedical Materials Research Part B: Applied Biomaterials
- Vol. 107 (2) , 400-407
Tissue reaction after subcutaneous implants of a new material composed of ethylene‐vinyl acetate and starch for future use as a biomaterial
This study aimed to evaluate the tissue reaction of ethylene‐vinyl acetate (EVA) in 4 different compositions and processing: EVA foamed at high pressure with ultrasound (EVACU); EVA with 15% starch foamed at high pressure with ultrasound (EVAMCU); EVA with 15% starch foamed at high pressure without ultrasound and EVA foamed at high pressure without ultrasound as future use as a porous scaffold. Scanning electron microscopy images showed the influence of starch, reducing the diameter of pores. The number of open pores was also reduced with the addition of starch. The ultrasound applied during the manufacturing of composites does not affect these characteristics. Eighteen rats were used to test the tissue reaction of materials and PTFE (polytetrafluoroethylene), proven biocompatible material. After 7, 15, and 60 days of surgery, the materials were removed and processed for microscopic evaluation and counting of the inflammatory infiltrate. The data shows inflammatory reaction similar to PTFE. However, in the quantitative analysis at 60 days, the EVACU and EVAMCU showed less quantity of mononuclear cells (p < 0.05). Thus, the results suggest that the use of ultrasound in the production method (EVA) seems to have improved cell behavior regarding the reduction of infiltration over the period, with tissue response equivalent to the PTFE. © 2018 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 2018.
- 11 April 2018
- Published by Wiley in Journal of Biomedical Materials Research Part B: Applied Biomaterials
- Vol. 107 (2) , 400-407
Tissue reaction after subcutaneous implants of a new material composed of ethylene‐vinyl acetate and starch for future use as a biomaterial
This study aimed to evaluate the tissue reaction of ethylene‐vinyl acetate (EVA) in 4 different compositions and processing: EVA foamed at high pressure with ultrasound (EVACU); EVA with 15% starch foamed at high pressure with ultrasound (EVAMCU); EVA with 15% starch foamed at high pressure without ultrasound and EVA foamed at high pressure without ultrasound as future use as a porous scaffold. Scanning electron microscopy images showed the influence of starch, reducing the diameter of pores. The number of open pores was also reduced with the addition of starch. The ultrasound applied during the manufacturing of composites does not affect these characteristics. Eighteen rats were used to test the tissue reaction of materials and PTFE (polytetrafluoroethylene), proven biocompatible material. After 7, 15, and 60 days of surgery, the materials were removed and processed for microscopic evaluation and counting of the inflammatory infiltrate. The data shows inflammatory reaction similar to PTFE. However, in the quantitative analysis at 60 days, the EVACU and EVAMCU showed less quantity of mononuclear cells (p < 0.05). Thus, the results suggest that the use of ultrasound in the production method (EVA) seems to have improved cell behavior regarding the reduction of infiltration over the period, with tissue response equivalent to the PTFE. © 2018 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 2018.
- 22 May 2014
- Published by Springer Nature in Journal of Materials Science: Materials in Medicine
- Vol. 25 (9) , 2111-2120
Comparison of the performance of natural latex membranes prepared with different procedures and PTFE membrane in guided bone regeneration (GBR) in rabbits
This work assessed the performance of membranes made of natural latex extracted from Hevea brasiliensis prepared with three different methods: polymerized immediately after collection without the use of ammonia (L1); polymerized after preservation in ammonia solution (L2); and polymerized after storage in ammonia, followed by Soxhlet technique for the extraction of substances (L3). Polytetrafluoroethylene (PTFE) membrane was used as control. Two 10-mm diameter bone defects were surgically made in the calvaria of thirty adult male New Zealand rabbits. Defects (total n = 60) were treated with guided bone regeneration (GBR) using L1, L2, L3 or PTFE membranes (n = 15 for each membrane). Ten animals were euthanized after 7, 20 and 60 days postoperatively so that five samples (n = 5) of each treatment were collected at each time, and bone regeneration was assessed microscopically. The microscopic analysis revealed defects filled with blood clot and new bone formation at the margins of the defect in all 7-day samples, while 20-day defects were mainly filled with fibrous connective tissue. After 60 days defects covered with L1 membranes showed a significantly larger bone formation area in comparison to the other groups (P < 0.05, ANOVA, Tukey). Additionally, bone tissue hypersensitization for L1 and PTFE membranes was also investigated in six additional rabbits. The animals were subjected to the same surgical procedure for the confection of one 10-mm diameter bone defect that was treated with L1 (n = 3) or PTFE (n = 3). Fifty-three days later, a second surgery was performed to make a second defect, which was treated with the same type of membrane used in the first surgery. Seven days later, the animals were euthanized and samples analyzed. No differences among L1 and PTFE samples collected from sensitized and non-sensitized animals were found (P > 0.05, Kruskal–Wallis). Therefore, the results demonstrated that latex membranes presented performance comparable to PTFE membranes, and that L1 membranes induced higher bone formation. L1 and PTFE membranes produced no hypersensitization in the bone tissue.
- 22 May 2014
- Published by Springer Nature in Journal of Materials Science: Materials in Medicine
- Vol. 25 (9) , 2111-2120
Comparison of the performance of natural latex membranes prepared with different procedures and PTFE membrane in guided bone regeneration (GBR) in rabbits
This work assessed the performance of membranes made of natural latex extracted from Hevea brasiliensis prepared with three different methods: polymerized immediately after collection without the use of ammonia (L1); polymerized after preservation in ammonia solution (L2); and polymerized after storage in ammonia, followed by Soxhlet technique for the extraction of substances (L3). Polytetrafluoroethylene (PTFE) membrane was used as control. Two 10-mm diameter bone defects were surgically made in the calvaria of thirty adult male New Zealand rabbits. Defects (total n = 60) were treated with guided bone regeneration (GBR) using L1, L2, L3 or PTFE membranes (n = 15 for each membrane). Ten animals were euthanized after 7, 20 and 60 days postoperatively so that five samples (n = 5) of each treatment were collected at each time, and bone regeneration was assessed microscopically. The microscopic analysis revealed defects filled with blood clot and new bone formation at the margins of the defect in all 7-day samples, while 20-day defects were mainly filled with fibrous connective tissue. After 60 days defects covered with L1 membranes showed a significantly larger bone formation area in comparison to the other groups (P < 0.05, ANOVA, Tukey). Additionally, bone tissue hypersensitization for L1 and PTFE membranes was also investigated in six additional rabbits. The animals were subjected to the same surgical procedure for the confection of one 10-mm diameter bone defect that was treated with L1 (n = 3) or PTFE (n = 3). Fifty-three days later, a second surgery was performed to make a second defect, which was treated with the same type of membrane used in the first surgery. Seven days later, the animals were euthanized and samples analyzed. No differences among L1 and PTFE samples collected from sensitized and non-sensitized animals were found (P > 0.05, Kruskal–Wallis). Therefore, the results demonstrated that latex membranes presented performance comparable to PTFE membranes, and that L1 membranes induced higher bone formation. L1 and PTFE membranes produced no hypersensitization in the bone tissue.
- 23 April 2014
- Published by Springer Nature in Lasers in Medical Science
- Vol. 30 (4) , 1225-1230
New LLLT protocol to speed up the bone healing process—histometric and immunohistochemical analysis in rat calvarial bone defect
- 23 April 2014
- Published by Springer Nature in Lasers in Medical Science
- Vol. 30 (4) , 1225-1230
New LLLT protocol to speed up the bone healing process—histometric and immunohistochemical analysis in rat calvarial bone defect
- 10 May 2013
- Published by Wiley in Journal of Biomedical Materials Research Part B: Applied Biomaterials
- Vol. 101 (7) , 1284-1293
Subcutaneous tissue reaction and cytotoxicity of polyvinylidene fluoride and polyvinylidene fluoride-trifluoroethylene blends associated with natural polymers
Cytotoxicity and subcutaneous tissue reaction of innovative blends composed by polyvinylidene fluoride and polyvinylidene fluoride-trifluoroethylene associated with natural polymers (natural rubber and native starch) forming membranes were evaluated, aiming its applications associated with bone regeneration. Cytotoxicity was evaluated in mouse fibroblasts culture cells (NIH3T3) using trypan blue staining. Tissue response was in vivo evaluated by subcutaneous implantation of materials in rats, taking into account the presence of necrosis and connective tissue capsule around implanted materials after 7, 14, 21, 28, 35, 60, and 100 days of surgery. The pattern of inflammation was evaluated by histomorphometry of the inflammatory cells. Chemical and morphological changes of implanted materials after 60 and 100 days were evaluated by Fourier transform infrared (FTIR) absorption spectroscopy and scanning electron microscopy (SEM) images. Cytotoxicity tests indicated a good tolerance of the cells to the biomaterial. The in vivo tissue response of all studied materials showed normal inflammatory pattern, characterized by a reduction of polymorphonuclear leukocytes and an increase in mononuclear leukocytes over the time (p < 0.05 Kruskal–Wallis). On day 60, microscopic analysis showed regression of the chronic inflammatory process around all materials. FTIR showed no changes in chemical composition of materials due to implantation, whereas SEM demonstrated the delivery of starch in the medium. Therefore, the results of the tests performed in vitro and in vivo show that the innovative blends can further be used as biomaterials. © 2013 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater 101B: 1284–1293, 2013.
- 10 May 2013
- Published by Wiley in Journal of Biomedical Materials Research Part B: Applied Biomaterials
- Vol. 101 (7) , 1284-1293
Subcutaneous tissue reaction and cytotoxicity of polyvinylidene fluoride and polyvinylidene fluoride-trifluoroethylene blends associated with natural polymers
Cytotoxicity and subcutaneous tissue reaction of innovative blends composed by polyvinylidene fluoride and polyvinylidene fluoride-trifluoroethylene associated with natural polymers (natural rubber and native starch) forming membranes were evaluated, aiming its applications associated with bone regeneration. Cytotoxicity was evaluated in mouse fibroblasts culture cells (NIH3T3) using trypan blue staining. Tissue response was in vivo evaluated by subcutaneous implantation of materials in rats, taking into account the presence of necrosis and connective tissue capsule around implanted materials after 7, 14, 21, 28, 35, 60, and 100 days of surgery. The pattern of inflammation was evaluated by histomorphometry of the inflammatory cells. Chemical and morphological changes of implanted materials after 60 and 100 days were evaluated by Fourier transform infrared (FTIR) absorption spectroscopy and scanning electron microscopy (SEM) images. Cytotoxicity tests indicated a good tolerance of the cells to the biomaterial. The in vivo tissue response of all studied materials showed normal inflammatory pattern, characterized by a reduction of polymorphonuclear leukocytes and an increase in mononuclear leukocytes over the time (p < 0.05 Kruskal–Wallis). On day 60, microscopic analysis showed regression of the chronic inflammatory process around all materials. FTIR showed no changes in chemical composition of materials due to implantation, whereas SEM demonstrated the delivery of starch in the medium. Therefore, the results of the tests performed in vitro and in vivo show that the innovative blends can further be used as biomaterials. © 2013 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater 101B: 1284–1293, 2013.
- 1 December 2012
- Published by Elsevier in Journal of Cranio-Maxillofacial Surgery
- Vol. 40 (8) , e315-e320
Bovine hydroxyapatite (Bio-Oss®) induces osteocalcin, RANK-L and osteoprotegerin expression in sinus lift of rabbits
- 1 December 2012
- Published by Elsevier in Journal of Cranio-Maxillofacial Surgery
- Vol. 40 (8) , e315-e320
Bovine hydroxyapatite (Bio-Oss®) induces osteocalcin, RANK-L and osteoprotegerin expression in sinus lift of rabbits
- 11 May 2010
- Published by Wiley in Clinical Oral Implants Research
- Vol. 21 (6) , 584-590
Immunoexpression of Cbfa‐1/Runx2 and VEGF in sinus lift procedures using bone substitutes in rabbits
Objectives: To analyze and compare the expression of core binding factor‐1 (Cbfa‐1)/Runx2 and vascular endothelium growth factor (VEGF) in sinus lift procedures using bovine hydroxyapatite (HA) and β‐tricalcium phosphate (β‐TCP).Material and Methods: Twenty‐four male rabbits that had undergone bilateral sinus lift procedures were divided into three groups, according to the sinus filling material: Group 1: autogenous bone graft; Group 2: bovine HA; and Group 3: β‐TCP. All groups were sacrificed after 7, 14, 30 and 60 days, for microscopic, histomorphometry and immunohistochemistry analysis.Results: Microscopic analysis showed a similar bone repair pattern between the tested groups. New bone formation, soft and medular tissue, remaining material or particulate bone graft area were obtained by histomorphometric analysis. After 14 days, statistically significant differences in new bone formation were found between Group 1 (27.76±7.8) and Groups 2 (14.22±3.2) and 3 (11.1±7.7). After 30 days, statistically significant differences (PConclusion: Taken together, both biomaterials allowed bone tissue growth in a conductive pattern and did not interfere with bone remodeling in the late period, with a slight improvement in bone tissue formation when using HA, confirmed by marked expression of Cbfa‐1 at initial periods. To cite this article: Nunes LSS, De Oliveira RV, Holgado LA, Nary Filho H, Ribeiro DA, Matsumoto MA. Immunoexpression of Cbfa‐1/Runx2 in sinus lift procedures using bone substitutes in rabbits. Clin. Oral Impl. Res. 21, 2010; 584–590. doi: 10.1111/j.1600‐0501.2009.01858.x
- 11 May 2010
- Published by Wiley in Clinical Oral Implants Research
- Vol. 21 (6) , 584-590
Immunoexpression of Cbfa‐1/Runx2 and VEGF in sinus lift procedures using bone substitutes in rabbits
Objectives: To analyze and compare the expression of core binding factor‐1 (Cbfa‐1)/Runx2 and vascular endothelium growth factor (VEGF) in sinus lift procedures using bovine hydroxyapatite (HA) and β‐tricalcium phosphate (β‐TCP).Material and Methods: Twenty‐four male rabbits that had undergone bilateral sinus lift procedures were divided into three groups, according to the sinus filling material: Group 1: autogenous bone graft; Group 2: bovine HA; and Group 3: β‐TCP. All groups were sacrificed after 7, 14, 30 and 60 days, for microscopic, histomorphometry and immunohistochemistry analysis.Results: Microscopic analysis showed a similar bone repair pattern between the tested groups. New bone formation, soft and medular tissue, remaining material or particulate bone graft area were obtained by histomorphometric analysis. After 14 days, statistically significant differences in new bone formation were found between Group 1 (27.76±7.8) and Groups 2 (14.22±3.2) and 3 (11.1±7.7). After 30 days, statistically significant differences (PConclusion: Taken together, both biomaterials allowed bone tissue growth in a conductive pattern and did not interfere with bone remodeling in the late period, with a slight improvement in bone tissue formation when using HA, confirmed by marked expression of Cbfa‐1 at initial periods. To cite this article: Nunes LSS, De Oliveira RV, Holgado LA, Nary Filho H, Ribeiro DA, Matsumoto MA. Immunoexpression of Cbfa‐1/Runx2 in sinus lift procedures using bone substitutes in rabbits. Clin. Oral Impl. Res. 21, 2010; 584–590. doi: 10.1111/j.1600‐0501.2009.01858.x