Shintaro Nakatani
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Shintaro Nakatani has a total of 52 co-authors. Here are the top co-authors by number of shared publications:
Nozomu Araki
Graduate School of Engineering, University of Hyogo, 2167, Shosha, Himeji, Hyogo, 671-2280, Japan
10 shared publicationsYasuo Konishi
7 shared publicationsKunihiko Mabuchi
The University of Tokyo Graduate School of Information Science and Technology, 7-3-1 Hongo, Bunkyo-ku, Tokyo, 113-8656, JAPAN
5 shared publicationsShin-Ichiro Nishida
Graduate School of Sustainability Science, Tottori University
5 shared publications- Nozomu Araki
Graduate School of Engineering, University of Hyogo
3 shared publications Ariki Sato
Department of Engineering, Graduate School of Sustainability Science, Tottori University, 4-101 Koyama-Minami Tottori, Tottori 680-9552, Japan
2 shared publications
Latest Publications
- Open Access
Enhancing Visuomotor Reaction during Dark Transition via Model-Optimized Transcutaneous Vagus Nerve Stimulation
Sudden reductions in ambient illuminance temporarily impair visuomotor performance due to the inherent latency of dark adaptation, posing significant risks in operational environments such as tunnel entry. To mitigate this degradation, we propose a model-based neuromodulation framework using transcutaneous vagus nerve stimulation (tVNS), which is known to accelerate and augment pupil dilation and potentially enhance sensorimotor processing by activating the locus coeruleus-norepinephrine (LC-NE) system. First, we characterized the temporal dynamics of the tVNS-induced pupillary response and developed a predictive model using a long short-term memory (LSTM) network in standard lighting. The model demonstrated efficacy in reproducing nonlinear physiological characteristics even under sudden dark exposure. Second, we derived optimized stimulation sequences using a genetic algorithm to maximize pupil dilation during immediate adaptation to darkness. Pupillary evaluations during bright-to-dark transitions revealed that the optimized tVNS additively increased pupil diameter. The improvement in visuomotor choice-reaction performance was highly correlated with the amount of tVNS-induced increase in pupil diameter during dark transition across healthy young adults. These findings suggest that the model-optimized tVNS approach may effectively mitigate the degradation of visuomotor performance during dark transitions via LC-NE activation as well as subsequent sensorimotor enhancement. Furthermore, the experimental results demonstrate the potential of the transient pupil response to tVNS to serve as a robust physiological indicator for predicting behavioral improvement.
Open AccessEnhancing Visuomotor Reaction during Dark Transition via Model-Optimized Transcutaneous Vagus Nerve Stimulation
Sudden reductions in ambient illuminance temporarily impair visuomotor performance due to the inherent latency of dark adaptation, posing significant risks in operational environments such as tunnel entry. To mitigate this degradation, we propose a model-based neuromodulation framework using transcutaneous vagus nerve stimulation (tVNS), which is known to accelerate and augment pupil dilation and potentially enhance sensorimotor processing by activating the locus coeruleus-norepinephrine (LC-NE) system. First, we characterized the temporal dynamics of the tVNS-induced pupillary response and developed a predictive model using a long short-term memory (LSTM) network in standard lighting. The model demonstrated efficacy in reproducing nonlinear physiological characteristics even under sudden dark exposure. Second, we derived optimized stimulation sequences using a genetic algorithm to maximize pupil dilation during immediate adaptation to darkness. Pupillary evaluations during bright-to-dark transitions revealed that the optimized tVNS additively increased pupil diameter. The improvement in visuomotor choice-reaction performance was highly correlated with the amount of tVNS-induced increase in pupil diameter during dark transition across healthy young adults. These findings suggest that the model-optimized tVNS approach may effectively mitigate the degradation of visuomotor performance during dark transitions via LC-NE activation as well as subsequent sensorimotor enhancement. Furthermore, the experimental results demonstrate the potential of the transient pupil response to tVNS to serve as a robust physiological indicator for predicting behavioral improvement.
- 10 February 2026
- Published by ASME International in Journal of Biomechanical Engineering
- Vol. 148 (4) , 1-9
Mechanical Evaluation for Dry Electrode Tip Geometry in Scalp Electroencephalography Measurements
In electroencephalography (EEG) with dry electrodes, a tradeoff between signal stability and user comfort is a critical barrier to long-term, wearable applications. While various approaches exist, the mechanical impact of electrode tip geometry has not been adequately quantified. Moreover, while existing evaluations utilize subjective feedback, which is an indispensable metric for assessing user comfort, quantitative, mechanics-based analyses that complement these findings have not yet been commonly established. The current study aimed to evaluate the mechanical influence of different electrode tip geometries under both vertical and tilted contact conditions. Finite element analysis was conducted using strain energy density (SED), a mechanical index known to correlate with neural impulse activity, as a quantitative indicator of the mechanical influence of tip geometry on the skin. Six types of electrode tip geometries, ranging from flat to hemispherical, were defined based on the ratio of fillet radius to prong radius. These geometries were analyzed under inclination angles from 0 deg to 5 deg, and their peak SED values were compared. Building on these initial trends, an iterative search algorithm was employed to identify the geometry ratio that tends to minimize peak SED across extended inclination angles up to 15 deg, evaluated as a design boundary. The findings indicate that intermediate fillet geometries tend to reduce peak SED under inclined conditions. While hemispherical tips appear favorable at inclination angles beyond 15 deg, intermediate geometries may offer improved load distribution within the inclination range of 0 deg to 10 deg evaluated in this study.
- 10 February 2026
- Published by ASME International in Journal of Biomechanical Engineering
- Vol. 148 (4) , 1-9
Mechanical Evaluation for Dry Electrode Tip Geometry in Scalp Electroencephalography Measurements
In electroencephalography (EEG) with dry electrodes, a tradeoff between signal stability and user comfort is a critical barrier to long-term, wearable applications. While various approaches exist, the mechanical impact of electrode tip geometry has not been adequately quantified. Moreover, while existing evaluations utilize subjective feedback, which is an indispensable metric for assessing user comfort, quantitative, mechanics-based analyses that complement these findings have not yet been commonly established. The current study aimed to evaluate the mechanical influence of different electrode tip geometries under both vertical and tilted contact conditions. Finite element analysis was conducted using strain energy density (SED), a mechanical index known to correlate with neural impulse activity, as a quantitative indicator of the mechanical influence of tip geometry on the skin. Six types of electrode tip geometries, ranging from flat to hemispherical, were defined based on the ratio of fillet radius to prong radius. These geometries were analyzed under inclination angles from 0 deg to 5 deg, and their peak SED values were compared. Building on these initial trends, an iterative search algorithm was employed to identify the geometry ratio that tends to minimize peak SED across extended inclination angles up to 15 deg, evaluated as a design boundary. The findings indicate that intermediate fillet geometries tend to reduce peak SED under inclined conditions. While hemispherical tips appear favorable at inclination angles beyond 15 deg, intermediate geometries may offer improved load distribution within the inclination range of 0 deg to 10 deg evaluated in this study.
- 1 August 2025
- Published by Elsevier in Vision Research
- Vol. 235, 108667
Binocular summation of pupil light reflex with different light stimulation in each eye
- 1 August 2025
- Published by Elsevier in Vision Research
- Vol. 235, 108667
Binocular summation of pupil light reflex with different light stimulation in each eye
- 2 February 2024
- Published by Elsevier in IFAC Journal of Systems and Control
- Vol. 27
Designing light stimulation for a pupillary–computer interface using binary code
- 2 February 2024
- Published by Elsevier in IFAC Journal of Systems and Control
- Vol. 27
Designing light stimulation for a pupillary–computer interface using binary code
- 19 December 2023
- Published by Elsevier in Journal of Terramechanics
- Vol. 112, 35-43
Study of passive steering mechanism for small Mars surface exploration rovers
- 19 December 2023
- Published by Elsevier in Journal of Terramechanics
- Vol. 112, 35-43
Study of passive steering mechanism for small Mars surface exploration rovers
- Open Access
- 1 December 2022
- Published by IOP Publishing in Journal of Neural Engineering
- Vol. 19 (6) , 066046
Independent bilateral-eye stimulation for gaze pattern recognition based on steady-state pupil light reflex
Objective: recently, pupil oscillations synchronized with steady visual stimuli were used as input for an interface. The proposed system, inspired by a brain-computer interface based on steady-state visual evoked potentials, does not require contact with the participant. However, the pupil oscillation mechanism limits the stimulus frequency to 2.5 Hz or less, making it hard to enhance the information transfer rate (ITR). Approach: here, we compared multiple conditions for stimulation to increase the ITR of the pupil vibration-based interface, which were called monocular-single, monocular-superposed, and binocular-independent conditions. The binocular-independent condition stimulates each eye at different frequencies respectively and mixes them by using the visual stereoscopic perception of users. The monocular-superposed condition stimulates both eyes by a mixed signal of two different frequencies. We selected the shape of the stimulation signal, evaluated the amount of spectral leakage in the monocular-superposed and binocular-independent conditions, and compared the power spectrum density at the stimulation frequency. Moreover, 5, 10, and 15 patterns of stimuli were classified in each condition. Main results: a square wave, which causes an efficient pupil response, was used as the stimulus. Spectral leakage at the beat frequency was higher in the monocular-superposed condition than in the binocular-independent one. The power spectral density of stimulus frequencies was greatest in the monocular-single condition. Finally, we could classify the 15-stimulus pattern, with ITRs of 14.4 (binocular-independent, using five frequencies), 14.5 (monocular-superimposed, using five frequencies), and 23.7 bits min−1 (monocular-single, using 15 frequencies). There were no significant differences for the binocular-independent and monocular-superposed conditions. Significance: this paper shows a way to increase the number of stimuli that can be simultaneously displayed without decreasing ITR, even when only a small number of frequencies are available. This could lead to the provision of an interface based on pupil oscillation to a wider range of users.
- 1 December 2022
- Published by IOP Publishing in Journal of Neural Engineering
- Vol. 19 (6) , 066046
Open AccessIndependent bilateral-eye stimulation for gaze pattern recognition based on steady-state pupil light reflex
Objective: recently, pupil oscillations synchronized with steady visual stimuli were used as input for an interface. The proposed system, inspired by a brain-computer interface based on steady-state visual evoked potentials, does not require contact with the participant. However, the pupil oscillation mechanism limits the stimulus frequency to 2.5 Hz or less, making it hard to enhance the information transfer rate (ITR). Approach: here, we compared multiple conditions for stimulation to increase the ITR of the pupil vibration-based interface, which were called monocular-single, monocular-superposed, and binocular-independent conditions. The binocular-independent condition stimulates each eye at different frequencies respectively and mixes them by using the visual stereoscopic perception of users. The monocular-superposed condition stimulates both eyes by a mixed signal of two different frequencies. We selected the shape of the stimulation signal, evaluated the amount of spectral leakage in the monocular-superposed and binocular-independent conditions, and compared the power spectrum density at the stimulation frequency. Moreover, 5, 10, and 15 patterns of stimuli were classified in each condition. Main results: a square wave, which causes an efficient pupil response, was used as the stimulus. Spectral leakage at the beat frequency was higher in the monocular-superposed condition than in the binocular-independent one. The power spectral density of stimulus frequencies was greatest in the monocular-single condition. Finally, we could classify the 15-stimulus pattern, with ITRs of 14.4 (binocular-independent, using five frequencies), 14.5 (monocular-superimposed, using five frequencies), and 23.7 bits min−1 (monocular-single, using 15 frequencies). There were no significant differences for the binocular-independent and monocular-superposed conditions. Significance: this paper shows a way to increase the number of stimuli that can be simultaneously displayed without decreasing ITR, even when only a small number of frequencies are available. This could lead to the provision of an interface based on pupil oscillation to a wider range of users.
- 1 February 2021
- Published by IOP Publishing in Journal of Neural Engineering
- Vol. 18 (1) , 016022
Brain-controlled cycling system for rehabilitation following paraplegia with delay-time prediction
Objective. Robotic rehabilitation systems have been investigated to assist with motor dysfunction recovery in patients with lower-extremity paralysis caused by central nervous system lesions. These systems are intended to provide appropriate sensory feedback associated with locomotion. Appropriate feedback is thought to cause synchronous neuron firing, resulting in the recovery of function. Approach. In this study, we designed and evaluated an ergometric cycling wheelchair, with a brain–machine interface (BMI), that can force the legs to move by including normal stepping speeds and quick responses. Experiments were conducted in five healthy subjects and one patient with spinal cord injury (SCI), who experienced the complete paralysis of the lower limbs. Event-related desynchronization in the β band (18–28 Hz) was used to detect lower-limb motor images. Main results. An ergometer-based BMI system was able to safely and easily force patients to perform leg movements, at a rate of approximately 1.6 s/step (19 rpm), with an online accuracy rate of 73.1% for the SCI participant. Mean detection time from the cue to pedaling onset was 0.83 ± 0.31 s. Significance. This system can easily and safely maintain a normal walking speed during the experiment and be designed to accommodate the expected delay between the intentional onset and physical movement, to achieve rehabilitation effects for each participant. Similar BMI systems, implemented with rehabilitation systems, may be applicable to a wide range of patients.
- 1 February 2021
- Published by IOP Publishing in Journal of Neural Engineering
- Vol. 18 (1) , 016022
Brain-controlled cycling system for rehabilitation following paraplegia with delay-time prediction
Objective. Robotic rehabilitation systems have been investigated to assist with motor dysfunction recovery in patients with lower-extremity paralysis caused by central nervous system lesions. These systems are intended to provide appropriate sensory feedback associated with locomotion. Appropriate feedback is thought to cause synchronous neuron firing, resulting in the recovery of function. Approach. In this study, we designed and evaluated an ergometric cycling wheelchair, with a brain–machine interface (BMI), that can force the legs to move by including normal stepping speeds and quick responses. Experiments were conducted in five healthy subjects and one patient with spinal cord injury (SCI), who experienced the complete paralysis of the lower limbs. Event-related desynchronization in the β band (18–28 Hz) was used to detect lower-limb motor images. Main results. An ergometer-based BMI system was able to safely and easily force patients to perform leg movements, at a rate of approximately 1.6 s/step (19 rpm), with an online accuracy rate of 73.1% for the SCI participant. Mean detection time from the cue to pedaling onset was 0.83 ± 0.31 s. Significance. This system can easily and safely maintain a normal walking speed during the experiment and be designed to accommodate the expected delay between the intentional onset and physical movement, to achieve rehabilitation effects for each participant. Similar BMI systems, implemented with rehabilitation systems, may be applicable to a wide range of patients.
- Open Access
- 1 January 2021
- Published by Japan Society for Aeronautical and Space Sciences in TRANSACTIONS OF THE JAPAN SOCIETY FOR AERONAUTICAL AND SPACE SCIENCES, AEROSPACE TECHNOLOGY JAPAN
- Vol. 19 (4) , 469-476
Study of a Planetary Exploration Rover with a Hinge-type Center-of-gravity Shift Mechanism
The rover for future Mars exploration will be expected to have higher rough terrain traveling performance compared with conventional rovers. In this paper, we propose a rover with a weight of about 30 kg that can be transported to Mars by a Japanese rocket. The purpose of this study is to propose and develop a hinge-type movable center-of-gravity mechanism wherein the bending of the rover's body with a motor shows high rough terrain-driving performance with minimum degrees of freedom. The proposed mechanism's performance is evaluated by conducting travel experiments on a assumed terrain, that is, a hard rock with a grade inclination of 45 deg and a height of 0.15 m above the sand. The effectiveness of the proposed mechanism in getting over a step was confirmed by conducting experiments using a prototype model.
- 1 January 2021
- Published by Japan Society for Aeronautical and Space Sciences in TRANSACTIONS OF THE JAPAN SOCIETY FOR AERONAUTICAL AND SPACE SCIENCES, AEROSPACE TECHNOLOGY JAPAN
- Vol. 19 (4) , 469-476
Open AccessStudy of a Planetary Exploration Rover with a Hinge-type Center-of-gravity Shift Mechanism
The rover for future Mars exploration will be expected to have higher rough terrain traveling performance compared with conventional rovers. In this paper, we propose a rover with a weight of about 30 kg that can be transported to Mars by a Japanese rocket. The purpose of this study is to propose and develop a hinge-type movable center-of-gravity mechanism wherein the bending of the rover's body with a motor shows high rough terrain-driving performance with minimum degrees of freedom. The proposed mechanism's performance is evaluated by conducting travel experiments on a assumed terrain, that is, a hard rock with a grade inclination of 45 deg and a height of 0.15 m above the sand. The effectiveness of the proposed mechanism in getting over a step was confirmed by conducting experiments using a prototype model.
- Open Access
3D Printable Dry EEG Electrodes with Coiled-Spring Prongs
Various dry electroencephalography (EEG) electrodes have been developed. Dry EEG electrodes need to be pressed onto the scalp; therefore, there is a tradeoff between keeping the contact impedance low and maintaining comfort. We propose an approach to solve this tradeoff through the printing of complex-shaped electrodes by using a stereolithography 3D printer. To show the feasibility of our approach, we fabricated electrodes that have flexible fingers (prongs) with springs. Although dry electrodes with flexible prongs have been proposed, a suitable spring constant has not been obtained. In this study, the spring constant of our electrodes was determined from a contact model between the electrodes and the scalp. The mechanical properties and reproductivity of the electrodes were found to be sufficient. Finally, we measured the alpha waves when a participant opened/closed his eyes by using our electrodes.
Open Access3D Printable Dry EEG Electrodes with Coiled-Spring Prongs
Various dry electroencephalography (EEG) electrodes have been developed. Dry EEG electrodes need to be pressed onto the scalp; therefore, there is a tradeoff between keeping the contact impedance low and maintaining comfort. We propose an approach to solve this tradeoff through the printing of complex-shaped electrodes by using a stereolithography 3D printer. To show the feasibility of our approach, we fabricated electrodes that have flexible fingers (prongs) with springs. Although dry electrodes with flexible prongs have been proposed, a suitable spring constant has not been obtained. In this study, the spring constant of our electrodes was determined from a contact model between the electrodes and the scalp. The mechanical properties and reproductivity of the electrodes were found to be sufficient. Finally, we measured the alpha waves when a participant opened/closed his eyes by using our electrodes.
- Open Access
- 1 January 2020
- Published by INSTICC
- p. 621-627
Geo-localization using Ridgeline Features Extracted from 360-degree Images of Sand Dunes
- 1 January 2020
- Published by INSTICC
- p. 621-627
Open AccessGeo-localization using Ridgeline Features Extracted from 360-degree Images of Sand Dunes