Hatem Kamkoum
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Hatem Kamkoum has a total of 29 co-authors. Here are the top co-authors by number of shared publications:
- Olivier Traxer
Service d’Urologie, Assistance-Publique Hôpitaux de Paris, Hôpital Tenon, Sorbonne Université, Paris, France
6 shared publications - Bhaskar Kumar Somani
University Hospital Southampton NHS Trust, UK
4 shared publications - Steeve Doizi
Service d’Urologie, Assistance-Publique Hôpitaux de Paris, Hôpital Tenon, Sorbonne Université, Paris, France
4 shared publications - Yazeed Barghouthy
Progressive Endourological Association for Research and Leading Solutions (PEARLS), Paris, France
4 shared publications - Mariela Corrales
Sorbonne University GRC Urolithiasis No. 20 Tenon Hospital, Paris, France
3 shared publications - Camilla Capretti
Institute of Urology, Polytechnic University of Marche, 60121 Ancona, Italy
2 shared publications
Latest Publications
- 8 February 2025
- Published by Springer Nature in World Journal of Urology
- Vol. 43 (1) , 1-9
General anaesthesia with gated or controlled mechanical ventilation and its influence on peri and post operative outcomes of retrograde intra renal surgery when using flexible and navigable suction access sheath, an EAU-endourology and Global FANS collaborative study group: a prospective study
Background Retrograde intrarenal surgery (RIRS) is a preferred treatment for renal stones, yet challenges such as kidney movement due to respiration hinder surgical precision and outcomes. The introduction of flexible and navigable suction ureteral access sheaths (FANS) and novel techniques like gated respiration aim to improve stone-free rates (SFR) and reduce complications. This study evaluates the impact of gated respiration on perioperative outcomes in RIRS with FANS. Methods A prospective multicenter study enrolled 562 adult patients undergoing RIRS with FANS under general anesthesia. Patients were divided into two groups: non-gated respiration (Group 1) and gated respiration (Group 2). Stone-free status (SFS) was assessed at 30 days using NCCT scans. SFS was defined as follows: grade A, zero fragments; grade B, a single fragment ≤ 2 mm; grade C, a single fragment 2.1–4 mm; and grade D, single/multiple fragments > 4 mm. Procedural efficiency, perioperative complications, and surgeon-reported outcomes were compared. Results Patients in Group 2 had significantly higher zero residual fragment (Grade A) rates (64.2% vs. 59%) and overall SFR (Grade A + B: 98.3% vs. 91.3%, p = 0.001). Gated respiration improved sheath navigation (91.2% vs. 85.1%, p = 0.038) and visibility during lithotripsy (p = 0.004), while reducing complications like mild bleeding due to sheath movement (3.1% vs. 11.2%, p < 0.001). Logistic regression identified gated respiration as a significant predictor of SFS (OR 6.26, 95% CI 2.28–22.6, p < 0.001). Conclusion Gated respiration synergistically enhances the efficacy of FANS in RIRS, improving SFR, procedural safety, and surgeon experience. This study highlights the importance of respiratory control as an adjunct to RIRS, emphasizing the need for interdisciplinary collaboration between surgical and anesthesiology teams.
- 8 February 2025
- Published by Springer Nature in World Journal of Urology
- Vol. 43 (1) , 1-9
General anaesthesia with gated or controlled mechanical ventilation and its influence on peri and post operative outcomes of retrograde intra renal surgery when using flexible and navigable suction access sheath, an EAU-endourology and Global FANS collaborative study group: a prospective study
Background Retrograde intrarenal surgery (RIRS) is a preferred treatment for renal stones, yet challenges such as kidney movement due to respiration hinder surgical precision and outcomes. The introduction of flexible and navigable suction ureteral access sheaths (FANS) and novel techniques like gated respiration aim to improve stone-free rates (SFR) and reduce complications. This study evaluates the impact of gated respiration on perioperative outcomes in RIRS with FANS. Methods A prospective multicenter study enrolled 562 adult patients undergoing RIRS with FANS under general anesthesia. Patients were divided into two groups: non-gated respiration (Group 1) and gated respiration (Group 2). Stone-free status (SFS) was assessed at 30 days using NCCT scans. SFS was defined as follows: grade A, zero fragments; grade B, a single fragment ≤ 2 mm; grade C, a single fragment 2.1–4 mm; and grade D, single/multiple fragments > 4 mm. Procedural efficiency, perioperative complications, and surgeon-reported outcomes were compared. Results Patients in Group 2 had significantly higher zero residual fragment (Grade A) rates (64.2% vs. 59%) and overall SFR (Grade A + B: 98.3% vs. 91.3%, p = 0.001). Gated respiration improved sheath navigation (91.2% vs. 85.1%, p = 0.038) and visibility during lithotripsy (p = 0.004), while reducing complications like mild bleeding due to sheath movement (3.1% vs. 11.2%, p < 0.001). Logistic regression identified gated respiration as a significant predictor of SFS (OR 6.26, 95% CI 2.28–22.6, p < 0.001). Conclusion Gated respiration synergistically enhances the efficacy of FANS in RIRS, improving SFR, procedural safety, and surgeon experience. This study highlights the importance of respiratory control as an adjunct to RIRS, emphasizing the need for interdisciplinary collaboration between surgical and anesthesiology teams.
- Open Access
Endoscopic Treatment of Upper Tract Urothelial Carcinoma: Challenging the Definition of the Maximal Lesion Size for Safe Ablation
Introduction: With advances in endoscopic treatment of upper tract urothelial carcinoma (UTUC) lesions, the recommended upper limit of lesion size amenable to laser ablation was set to 2 cm. However, this limit is based on expert opinion only, and debate still exists regarding this definition. Objective: To determine the maximal size of the tissue, for which total endoscopic ablation with laser energy is achievable, from a laser performance perspective. Materials and Methods: Simulating endoscopic surgery conditions, renal tissue blocks from pork kidneys in growing size from 1 cm3 to 3 cm3 were totally ablated with Ho:YAG laser (1 J, 10 Hz). The time to ablation was recorded for each tissue mass. Following the ablation, each sample was inspected microscopically by an expert pathologist to determine the extent to which the tissue was destroyed. Results: Time to ablation ranged from 16.4 min for a 1 cm3 mass, to 69.7 min for a 3 cm3 mass. Histologic evaluation after laser ablation showed that ablation was achieved in all tissue masses, and no “unaffected” tissue was present, even for lesions with a size of 3 cm3. Conclusions: This study showed that laser ablation can be achieved for tumor lesions up to a size of 3 cm3. The results of this study can contribute to the debate regarding the limits of endoscopic management of UTUC lesions and strengthen the recommended upper limit of 2 cm3 for endoscopic treatment of tumor lesions.
Open AccessEndoscopic Treatment of Upper Tract Urothelial Carcinoma: Challenging the Definition of the Maximal Lesion Size for Safe Ablation
Introduction: With advances in endoscopic treatment of upper tract urothelial carcinoma (UTUC) lesions, the recommended upper limit of lesion size amenable to laser ablation was set to 2 cm. However, this limit is based on expert opinion only, and debate still exists regarding this definition. Objective: To determine the maximal size of the tissue, for which total endoscopic ablation with laser energy is achievable, from a laser performance perspective. Materials and Methods: Simulating endoscopic surgery conditions, renal tissue blocks from pork kidneys in growing size from 1 cm3 to 3 cm3 were totally ablated with Ho:YAG laser (1 J, 10 Hz). The time to ablation was recorded for each tissue mass. Following the ablation, each sample was inspected microscopically by an expert pathologist to determine the extent to which the tissue was destroyed. Results: Time to ablation ranged from 16.4 min for a 1 cm3 mass, to 69.7 min for a 3 cm3 mass. Histologic evaluation after laser ablation showed that ablation was achieved in all tissue masses, and no “unaffected” tissue was present, even for lesions with a size of 3 cm3. Conclusions: This study showed that laser ablation can be achieved for tumor lesions up to a size of 3 cm3. The results of this study can contribute to the debate regarding the limits of endoscopic management of UTUC lesions and strengthen the recommended upper limit of 2 cm3 for endoscopic treatment of tumor lesions.
- 10 January 2022
- Published by Elsevier in Progrès en Urologie
- Vol. 32 (8-9) , 616-622
Comparison of irrigation flows between different irrigation methods for flexible ureteroscopy: An in vitro study
- 10 January 2022
- Published by Elsevier in Progrès en Urologie
- Vol. 32 (8-9) , 616-622
Comparison of irrigation flows between different irrigation methods for flexible ureteroscopy: An in vitro study
- 1 March 2021
- Published by SAGE Publications in Journal of Endourology
- Vol. 35 (3) , 241-248
Ultrasound or Fluoroscopy for Percutaneous Nephrolithotomy Access, Is There Really a Difference? A Review of Literature
Objective: To compare whether the outcomes of ultrasound-guided access percutaneous nephrolithotomy (USGA-PCNL) are similar to standard fluoroscopy-guided access percutaneous nephrolithotomy (FGA-PCNL). Methods: A review was developed by using the MEDLINE and Scopus databases and following the Preferred Reporting Items for Systematic Reviews and Meta-Analyses protocol. Studies comparing the USGA-PCNL and the FGA-PCNL were included. Case reports, editorials and letters, unpublished studies, posters, and comments abstracts were excluded. Results: We found 12 published articles that compared USGA-PCNL and FGA-PCNL. These included six randomized controlled trials, three case–control trials, and three meta-analyses. The overall results showed no difference in the success of percutaneous access, bleeding, blood transfusion, operative time, postoperative complications, or hospital stay. Conclusion: The reported data demonstrate that there are no significant differences between the fluoroscopic-guided access PCNL and the ultrasonographic access PCNL. The choice of puncture depends on the surgeon's expertise in a particular technique and the patient and stone characteristics. Both approaches are equally safe and effective in experienced hands. It is important to recall that the use of one technique does not exclude the use of the other, and they can sometimes be complementary to each other.
- 1 March 2021
- Published by SAGE Publications in Journal of Endourology
- Vol. 35 (3) , 241-248
Ultrasound or Fluoroscopy for Percutaneous Nephrolithotomy Access, Is There Really a Difference? A Review of Literature
Objective: To compare whether the outcomes of ultrasound-guided access percutaneous nephrolithotomy (USGA-PCNL) are similar to standard fluoroscopy-guided access percutaneous nephrolithotomy (FGA-PCNL). Methods: A review was developed by using the MEDLINE and Scopus databases and following the Preferred Reporting Items for Systematic Reviews and Meta-Analyses protocol. Studies comparing the USGA-PCNL and the FGA-PCNL were included. Case reports, editorials and letters, unpublished studies, posters, and comments abstracts were excluded. Results: We found 12 published articles that compared USGA-PCNL and FGA-PCNL. These included six randomized controlled trials, three case–control trials, and three meta-analyses. The overall results showed no difference in the success of percutaneous access, bleeding, blood transfusion, operative time, postoperative complications, or hospital stay. Conclusion: The reported data demonstrate that there are no significant differences between the fluoroscopic-guided access PCNL and the ultrasonographic access PCNL. The choice of puncture depends on the surgeon's expertise in a particular technique and the patient and stone characteristics. Both approaches are equally safe and effective in experienced hands. It is important to recall that the use of one technique does not exclude the use of the other, and they can sometimes be complementary to each other.
- 2 January 2021
- Published by Springer Nature in World Journal of Urology
- Vol. 39 (9) , 3197-3205
A systematic review of long-duration stents for ureteral stricture: which one to choose?
Objective To define which long-term stent would work best in malignant ureteral obstruction (MUO) and benign ureteral obstruction (BUO), focusing on their mechanisms of action, price and insertion approach. Methods A systematic review was developed using the MEDLINE and Scopus databases and in accordance with the PRISMA checklist. There were no language restrictions for the search. Studies describing the use of metallic ureteric stents for MUO and for BUO in humans were included. Results We analyzed five types of metallic stents (35 papers) and also the experience with the tumor and extra-anatomical stents. The Resonance, Memokath and Allium ureteral stents were found to be useful in BUO and MUO. The Uventa stent performed well in chronic ureteral obstruction. The Detour bypass stent was a recommended option in those patients who had complete obstruction of the ureter and were unfit for reconstructive surgery. There was no difference with regard to the insertion technique and both antegrade and retrograde approaches were equally successful. Although tumor stents showed a good performance, there were very few published studies on it. Conclusion Metallic stents are a suitable option for MUO and BUO. When compared to standard double J stents, although they are relatively high priced, they show a financial benefit in the long-term. The Detour bypass stent seems to be an effective alternative for complete ureteral obstruction or patients unfit for surgery. Further prospective randomized studies should be done on the effectiveness of tumor stents versus metallic stents.
- 2 January 2021
- Published by Springer Nature in World Journal of Urology
- Vol. 39 (9) , 3197-3205
A systematic review of long-duration stents for ureteral stricture: which one to choose?
Objective To define which long-term stent would work best in malignant ureteral obstruction (MUO) and benign ureteral obstruction (BUO), focusing on their mechanisms of action, price and insertion approach. Methods A systematic review was developed using the MEDLINE and Scopus databases and in accordance with the PRISMA checklist. There were no language restrictions for the search. Studies describing the use of metallic ureteric stents for MUO and for BUO in humans were included. Results We analyzed five types of metallic stents (35 papers) and also the experience with the tumor and extra-anatomical stents. The Resonance, Memokath and Allium ureteral stents were found to be useful in BUO and MUO. The Uventa stent performed well in chronic ureteral obstruction. The Detour bypass stent was a recommended option in those patients who had complete obstruction of the ureter and were unfit for reconstructive surgery. There was no difference with regard to the insertion technique and both antegrade and retrograde approaches were equally successful. Although tumor stents showed a good performance, there were very few published studies on it. Conclusion Metallic stents are a suitable option for MUO and BUO. When compared to standard double J stents, although they are relatively high priced, they show a financial benefit in the long-term. The Detour bypass stent seems to be an effective alternative for complete ureteral obstruction or patients unfit for surgery. Further prospective randomized studies should be done on the effectiveness of tumor stents versus metallic stents.
- 21 September 2020
- Published by Springer Nature in World Journal of Urology
- Vol. 39 (7) , 2709-2717
Comparison of intrapelvic pressures during flexible ureteroscopy, mini-percutaneous nephrolithotomy, standard percutaneous nephrolithotomy, and endoscopic combined intrarenal surgery in a kidney model
Purpose To compare intrapelvic pressure (IPP) levels achieved during f-URS, mini-PCNL, standard PCNL, and endoscopic combined intrarenal surgery in a kidney model. Methods A silicone model simulating the complete urinary tract was used for all the experiments. We compared: a 9.5Fr f-URS, a 12Fr mini-nephroscope and a 26Fr nephroscope. The irrigation pressure was set at 40 and 193 cmH2O. We compared: f-URS-S ± ureteral access sheath (UAS, 10/12Fr, 11/13Fr, 12/14Fr) ± 273 μm laser fiber, Mini-PCNL with different sizes of operating sheath (15/16Fr, 16.5/17.5Fr, 21/22Fr) ± 365 μm laser fiber, Standard PCNL with an operating sheath of 30Fr ± Lithotripter LithoClast Master 11.4Fr. Results f-URS: IPP values ranged between 1.4 and 46.2 cmH2O. Factors reducing IPP were an irrigation pressure at 40 cmH2O, an occupied working channel, and the use of a UAS except with the 10/12Fr at 193 cmH2O. Mini-PCNL: IPP values ranged between 2.4 and 39.7 cmH2O. Factors reducing IPP were irrigation pressure at 40 cmH2O, a large operating sheath (> 15/16Fr). The occupation of the working channel did not affect the IPP at 40 cmH2O, while it decreased at 193 cmH2O. Standard PCNL: IPP values ranged between 1.4 and 7.3 cmH2O. Occupancy of the working channel did not affect IPP at 40 cmH2O, while it increased at 193 cmH2O. Conclusion We recorded for the first time IPP values according to different endourological techniques and configurations. IPP never exceed 50 cmH2O irrespectively of the assessed technique/setup. The factors reducing IPP were a low irrigation pressure (40 cmH2O), the use of a UAS or a working sheath appropriate to the diameter of the endoscope, as well as the occupation of the working channel in the case of f-URS.
- 21 September 2020
- Published by Springer Nature in World Journal of Urology
- Vol. 39 (7) , 2709-2717
Comparison of intrapelvic pressures during flexible ureteroscopy, mini-percutaneous nephrolithotomy, standard percutaneous nephrolithotomy, and endoscopic combined intrarenal surgery in a kidney model
Purpose To compare intrapelvic pressure (IPP) levels achieved during f-URS, mini-PCNL, standard PCNL, and endoscopic combined intrarenal surgery in a kidney model. Methods A silicone model simulating the complete urinary tract was used for all the experiments. We compared: a 9.5Fr f-URS, a 12Fr mini-nephroscope and a 26Fr nephroscope. The irrigation pressure was set at 40 and 193 cmH2O. We compared: f-URS-S ± ureteral access sheath (UAS, 10/12Fr, 11/13Fr, 12/14Fr) ± 273 μm laser fiber, Mini-PCNL with different sizes of operating sheath (15/16Fr, 16.5/17.5Fr, 21/22Fr) ± 365 μm laser fiber, Standard PCNL with an operating sheath of 30Fr ± Lithotripter LithoClast Master 11.4Fr. Results f-URS: IPP values ranged between 1.4 and 46.2 cmH2O. Factors reducing IPP were an irrigation pressure at 40 cmH2O, an occupied working channel, and the use of a UAS except with the 10/12Fr at 193 cmH2O. Mini-PCNL: IPP values ranged between 2.4 and 39.7 cmH2O. Factors reducing IPP were irrigation pressure at 40 cmH2O, a large operating sheath (> 15/16Fr). The occupation of the working channel did not affect the IPP at 40 cmH2O, while it decreased at 193 cmH2O. Standard PCNL: IPP values ranged between 1.4 and 7.3 cmH2O. Occupancy of the working channel did not affect IPP at 40 cmH2O, while it increased at 193 cmH2O. Conclusion We recorded for the first time IPP values according to different endourological techniques and configurations. IPP never exceed 50 cmH2O irrespectively of the assessed technique/setup. The factors reducing IPP were a low irrigation pressure (40 cmH2O), the use of a UAS or a working sheath appropriate to the diameter of the endoscope, as well as the occupation of the working channel in the case of f-URS.