Francesca Brero
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Francesca Brero has a total of 188 co-authors. Here are the top co-authors by number of shared publications:
- Alessandro Lascialfari
University of Pavia
15 shared publications - Paolo Arosio
Università degli Studi di Milano
12 shared publications - Francesco Orsini
University of Milan
7 shared publications - Claudia Innocenti
National Interuniversity Consortium of Materials Science and Technology (INSTM), Via G. Giusti 9, 50121 Florence, Italy
6 shared publications - Claudio Sangregorio
ICCOM-CNR
6 shared publications - Manuel Mariani
Physics Department, University of Pavia, Pavia, Italy
6 shared publications
Latest Publications
- Open Access
- 28 October 2026
- Published by American Physical Society (APS) in Physical Review Applied
- Vol. 26 (4)
Zn 2 + and Mn 2 + doping effect on spin dynamics of Fe 3 O 4 -based magnetic nanoparticles: A possible path to efficient MRI contrast agents
Iron oxide-based magnetic nanoparticles (MNPs) play a major role as contrast agents for magnetic resonance imaging (MRI). The introduction of Zn 2 + and Mn 2 + ions within their crystal lattice alters the magnetic anisotropy and the spin dynamical properties of the systems, which in turn influence the nuclear relaxation mechanisms that drive contrast enhancement in MRI. This work explored two sets of doped-magnetite MNPs (chemical formula Zn x Mn y Fe 3 − x − y O 4 ) with core diameters of d ∼ 4 or 15 nm produced by the fast and reproducible microwave-assisted synthesis method, and using different solvents like water or polyols. The d ∼ 4 nm MNPs were doped with Zn 2 + , from x = 0 to 0.9; for Zn 2 + = 0.5 , Mn 2 + was introduced at y = 0.2 , 0.4 . The d ∼ 15 nm MNPs were doped with Zn 2 + from x = 0 to 0.4, with Mn 2 + added at y = 0.1 for Zn 2 + = 0.3 and at 0.3 for Zn 2 + = 0.4 . Both sets were dispersed in water with carboxymethyl-dextran or polyacrylic acid coatings to ensure their colloidal stability, even under high magnetic fields. We highlighted the influence of the size and of the Zn 2 + / Mn 2 + doping on the static and dynamical magnetic properties, also through the H 1 -NMR-dispersion profile analysis over a wide frequency range and the application of the superparamagnetic relaxation heuristic model. Larger particles exhibited higher nuclear relaxometric efficiency and anisotropy compared to the smaller ones, consistently outperforming the commercial contrast agents. On the other hand, the magnetic response and the nuclear relaxivities are enhanced by a Zn 2 + content of x = 0.1 ions for approximately 4 nm MNPs and of x = 0.4 for approximately 15 nm MNPs, while a slight enhancing effect was obtained by Mn 2 + introduction. It is thus shown how a proper size and doping combination provide an attractive way to modify the static and dynamical magnetic properties of MNPs by acting on different spin-spin correlation times dominating in specific frequency intervals, thus enabling the fine-tuning of image contrast properties suitable for magnetic resonance imaging.
- 28 October 2026
- Published by American Physical Society (APS) in Physical Review Applied
- Vol. 26 (4)
Open AccessZn 2 + and Mn 2 + doping effect on spin dynamics of Fe 3 O 4 -based magnetic nanoparticles: A possible path to efficient MRI contrast agents
Iron oxide-based magnetic nanoparticles (MNPs) play a major role as contrast agents for magnetic resonance imaging (MRI). The introduction of Zn 2 + and Mn 2 + ions within their crystal lattice alters the magnetic anisotropy and the spin dynamical properties of the systems, which in turn influence the nuclear relaxation mechanisms that drive contrast enhancement in MRI. This work explored two sets of doped-magnetite MNPs (chemical formula Zn x Mn y Fe 3 − x − y O 4 ) with core diameters of d ∼ 4 or 15 nm produced by the fast and reproducible microwave-assisted synthesis method, and using different solvents like water or polyols. The d ∼ 4 nm MNPs were doped with Zn 2 + , from x = 0 to 0.9; for Zn 2 + = 0.5 , Mn 2 + was introduced at y = 0.2 , 0.4 . The d ∼ 15 nm MNPs were doped with Zn 2 + from x = 0 to 0.4, with Mn 2 + added at y = 0.1 for Zn 2 + = 0.3 and at 0.3 for Zn 2 + = 0.4 . Both sets were dispersed in water with carboxymethyl-dextran or polyacrylic acid coatings to ensure their colloidal stability, even under high magnetic fields. We highlighted the influence of the size and of the Zn 2 + / Mn 2 + doping on the static and dynamical magnetic properties, also through the H 1 -NMR-dispersion profile analysis over a wide frequency range and the application of the superparamagnetic relaxation heuristic model. Larger particles exhibited higher nuclear relaxometric efficiency and anisotropy compared to the smaller ones, consistently outperforming the commercial contrast agents. On the other hand, the magnetic response and the nuclear relaxivities are enhanced by a Zn 2 + content of x = 0.1 ions for approximately 4 nm MNPs and of x = 0.4 for approximately 15 nm MNPs, while a slight enhancing effect was obtained by Mn 2 + introduction. It is thus shown how a proper size and doping combination provide an attractive way to modify the static and dynamical magnetic properties of MNPs by acting on different spin-spin correlation times dominating in specific frequency intervals, thus enabling the fine-tuning of image contrast properties suitable for magnetic resonance imaging.
- Open Access
- 15 October 2026
- Published by MDPI AG in Journal of Imaging
- Vol. 12 (10) , 514
Segmentation-Free 3D Deep Learning for CT-Based Chronic Rhinosinusitis Classification
Chronic rhinosinusitis (CRS) is routinely assessed with computed tomography (CT), but CT-based differentiation between CRS with nasal polyps (CRSwNP) and without nasal polyps (CRSsNP) remains challenging. We retrospectively evaluated a segmentation-free three-dimensional convolutional neural network (3D CNN) for three-class classification using an audited cohort of 776 adult CT examinations: 155 CRSwNP, 222 CRSsNP, and 399 endocrine orbitopathy (EO) non-CRS controls. The volumes were standardized to 150 × 150 × 150 voxels. Baseline, augmentation, and augmentation-plus-L2 configurations were compared exclusively by validation macro-F1 before the primary locked-test evaluation of the selected compact model; post hoc architecture and sensitivity analyses were subsequently performed on the same frozen test set and were considered exploratory. On the 155-patient held-out test set, the validation-selected compact model achieved an accuracy of 0.748 (95% CI 0.684–0.813), balanced accuracy of 0.683 (0.602–0.763), macro-F1 of 0.691 (0.607–0.770), and macro one-versus-rest AUC of 0.882 (0.841–0.919). Performance was strongest for EO-control discrimination (one-versus-rest AUC 0.959), whereas direct CRSsNP-versus-CRSwNP discrimination was more limited (AUC 0.704; 95% CI 0.574–0.827). The CRSwNP recall was 0.452, and 15 of 31 CRSwNP cases were classified as CRSsNP. Thus, the aggregate macro-AUC was influenced predominantly by the stronger separation of EO controls from CRS and should not be interpreted as uniformly strong CRS phenotype discrimination. In a post hoc architecture sensitivity analysis, a 3D ResNet-10 achieved a higher observed test macro-F1 of 0.742, but used approximately 206 times as many parameters as the compact model. The HiResCAM maps were technically valid in all test cases, although 38/155 maps (24.5%) peaked outside an intensity-derived patient envelope that was not a sinus segmentation mask. These findings provide a research-stage proof of concept for future studies on CRS subtype discrimination; however, potential demographic- and acquisition-related shortcuts, together with the absence of external validation, preclude any claim of clinical readiness.
- 15 October 2026
- Published by MDPI AG in Journal of Imaging
- Vol. 12 (10) , 514
Open AccessSegmentation-Free 3D Deep Learning for CT-Based Chronic Rhinosinusitis Classification
Chronic rhinosinusitis (CRS) is routinely assessed with computed tomography (CT), but CT-based differentiation between CRS with nasal polyps (CRSwNP) and without nasal polyps (CRSsNP) remains challenging. We retrospectively evaluated a segmentation-free three-dimensional convolutional neural network (3D CNN) for three-class classification using an audited cohort of 776 adult CT examinations: 155 CRSwNP, 222 CRSsNP, and 399 endocrine orbitopathy (EO) non-CRS controls. The volumes were standardized to 150 × 150 × 150 voxels. Baseline, augmentation, and augmentation-plus-L2 configurations were compared exclusively by validation macro-F1 before the primary locked-test evaluation of the selected compact model; post hoc architecture and sensitivity analyses were subsequently performed on the same frozen test set and were considered exploratory. On the 155-patient held-out test set, the validation-selected compact model achieved an accuracy of 0.748 (95% CI 0.684–0.813), balanced accuracy of 0.683 (0.602–0.763), macro-F1 of 0.691 (0.607–0.770), and macro one-versus-rest AUC of 0.882 (0.841–0.919). Performance was strongest for EO-control discrimination (one-versus-rest AUC 0.959), whereas direct CRSsNP-versus-CRSwNP discrimination was more limited (AUC 0.704; 95% CI 0.574–0.827). The CRSwNP recall was 0.452, and 15 of 31 CRSwNP cases were classified as CRSsNP. Thus, the aggregate macro-AUC was influenced predominantly by the stronger separation of EO controls from CRS and should not be interpreted as uniformly strong CRS phenotype discrimination. In a post hoc architecture sensitivity analysis, a 3D ResNet-10 achieved a higher observed test macro-F1 of 0.742, but used approximately 206 times as many parameters as the compact model. The HiResCAM maps were technically valid in all test cases, although 38/155 maps (24.5%) peaked outside an intensity-derived patient envelope that was not a sinus segmentation mask. These findings provide a research-stage proof of concept for future studies on CRS subtype discrimination; however, potential demographic- and acquisition-related shortcuts, together with the absence of external validation, preclude any claim of clinical readiness.
- Open Access
- 29 May 2026
- Published by Springer Nature in Communications Physics
- Vol. 9 (1)
Exploring the potential of molecular nanomagnets as quantum sensors of radiation
- 29 May 2026
- Published by Springer Nature in Communications Physics
- Vol. 9 (1)
Open AccessExploring the potential of molecular nanomagnets as quantum sensors of radiation
- 7 May 2026
- Published by Elsevier in Materials Today Chemistry
- Vol. 54
Engineering anisotropic magnetic-plasmonic Au–Fe3O4 nano-urchins for theranostic applications
- 7 May 2026
- Published by Elsevier in Materials Today Chemistry
- Vol. 54
Engineering anisotropic magnetic-plasmonic Au–Fe3O4 nano-urchins for theranostic applications
- Open Access
- 22 January 2026
- Published by Royal Society of Chemistry (RSC) in Dalton Transactions
- Vol. 55 (8) , 3242-3258
Upcycled materials for water treatment and emerging contaminant recovery: a preliminary study on waste-derived magnetic zeolites
This study explores the applicability of magnetic zeolites from industrial waste for the removal of emerging water contaminants and their recovery by ultrasound (UsAE), microwave (MwAE), and magnetic hyperthermia (MhAE) assisted extraction.
- 22 January 2026
- Published by Royal Society of Chemistry (RSC) in Dalton Transactions
- Vol. 55 (8) , 3242-3258
Open AccessUpcycled materials for water treatment and emerging contaminant recovery: a preliminary study on waste-derived magnetic zeolites
This study explores the applicability of magnetic zeolites from industrial waste for the removal of emerging water contaminants and their recovery by ultrasound (UsAE), microwave (MwAE), and magnetic hyperthermia (MhAE) assisted extraction.
- 22 December 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Magnetics
- Vol. 62 (2) , 1-6
Shell Thickness-Dependent Anisotropy in CoFe 2 O 4 @NiFe 2 O 4 Core/Shell Nanoparticles for Magnetic Heating
Using seed-mediated high temperature decomposition method, we synthesized CoFe2O4@NiFe2O4 core/shell nanoparticles with controlled shell thicknesses from ~1 to 6 nm and evaluated their performance in magnetic hyperthermia. A clear enhancement in heating efficiency was observed, with SAR values increasing from ~40 W·g−1 for bare CoFe2O4 to ~80 W·g−1 for the thickest-shell sample. This trend is attributed to optimized magnetic anisotropy and particle volume, enhancing thermal stability and energy dissipation under alternating magnetic fields below Hergt–Dutz limit. These findings support the strategic design of hard@soft ferrite architectures for biomedical heating applications. Although the particles are capped with oleate ligands from the synthesis, these results highlight the tunability of hard@soft ferrite systems and offer insight into the future design of biocompatible hyperthermia agents.
- 22 December 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Magnetics
- Vol. 62 (2) , 1-6
Shell Thickness-Dependent Anisotropy in CoFe 2 O 4 @NiFe 2 O 4 Core/Shell Nanoparticles for Magnetic Heating
Using seed-mediated high temperature decomposition method, we synthesized CoFe2O4@NiFe2O4 core/shell nanoparticles with controlled shell thicknesses from ~1 to 6 nm and evaluated their performance in magnetic hyperthermia. A clear enhancement in heating efficiency was observed, with SAR values increasing from ~40 W·g−1 for bare CoFe2O4 to ~80 W·g−1 for the thickest-shell sample. This trend is attributed to optimized magnetic anisotropy and particle volume, enhancing thermal stability and energy dissipation under alternating magnetic fields below Hergt–Dutz limit. These findings support the strategic design of hard@soft ferrite architectures for biomedical heating applications. Although the particles are capped with oleate ligands from the synthesis, these results highlight the tunability of hard@soft ferrite systems and offer insight into the future design of biocompatible hyperthermia agents.
- Open Access
- 11 December 2025
- Published by IOP Publishing in Biomedical Physics & Engineering Express
- Vol. 12 (1) , 015019
Multisequence MRI-driven assessment of PD-L1 expression in non-small cell lung cancer: a pilot study
Objective. Lung cancer remains the leading cause of cancer-related mortality worldwide, with Non-Small Cell Lung Cancer (NSCLC) accounting for approximately 85% of all cases. Programmed cell Death Ligand-1 (PD-L1) is a well-established biomarker that guides immunotherapy in advanced-stage NSCLC, currently evaluated via invasive biopsy procedures. This study aims to develop and validate a non-invasive pipeline for stratifying PD-L1 expression using quantitative analysis of IVIM parameter maps—diffusion (D), pseudo-diffusion (D*), perfusion fraction (pf)—and T1-VIBE MRI acquisitions. Approach. MRI data from 43 NSCLC patients were analysed and labelled as PD-L1 positive (≥1%) or negative (Main Results. Logistic Regression generally demonstrated the highest classification performance, with AUC values ranging from 0.78 to 0.92 across all feature sets. Fusion models outperformed or matched the performance of the best standalone radiomics or deep learning model. Among multisequence MRI, the IVIM-D fusion features yielded the best performance with an AUC of 0.92, followed by IVIM-D* radiomic features that showed a similar AUC of 0.91. For IVIM-pf and T1-VIBE derived features, the fusion model yielded the best AUC values of 0.87 and 0.90, respectively. Significance. The obtained results highlight the potential of a combined radiomic-deep learning approach to effectively detect PD-L1 expression from MRI acquisitions, paving the way for a non-invasive PD-L1 evaluation procedure.
- 11 December 2025
- Published by IOP Publishing in Biomedical Physics & Engineering Express
- Vol. 12 (1) , 015019
Open AccessMultisequence MRI-driven assessment of PD-L1 expression in non-small cell lung cancer: a pilot study
Objective. Lung cancer remains the leading cause of cancer-related mortality worldwide, with Non-Small Cell Lung Cancer (NSCLC) accounting for approximately 85% of all cases. Programmed cell Death Ligand-1 (PD-L1) is a well-established biomarker that guides immunotherapy in advanced-stage NSCLC, currently evaluated via invasive biopsy procedures. This study aims to develop and validate a non-invasive pipeline for stratifying PD-L1 expression using quantitative analysis of IVIM parameter maps—diffusion (D), pseudo-diffusion (D*), perfusion fraction (pf)—and T1-VIBE MRI acquisitions. Approach. MRI data from 43 NSCLC patients were analysed and labelled as PD-L1 positive (≥1%) or negative (Main Results. Logistic Regression generally demonstrated the highest classification performance, with AUC values ranging from 0.78 to 0.92 across all feature sets. Fusion models outperformed or matched the performance of the best standalone radiomics or deep learning model. Among multisequence MRI, the IVIM-D fusion features yielded the best performance with an AUC of 0.92, followed by IVIM-D* radiomic features that showed a similar AUC of 0.91. For IVIM-pf and T1-VIBE derived features, the fusion model yielded the best AUC values of 0.87 and 0.90, respectively. Significance. The obtained results highlight the potential of a combined radiomic-deep learning approach to effectively detect PD-L1 expression from MRI acquisitions, paving the way for a non-invasive PD-L1 evaluation procedure.
- Open Access
- 16 May 2025
- Published by Royal Society of Chemistry (RSC) in Dalton Transactions
- Vol. 54 (22) , 9057-9068
Iron oxide nanospheres: dual functionality as MRI contrast agents and magnetic fluid hyperthermia therapeutics
Magnetic nanoparticles offer the possibility of combining diagnostic and therapeutic purposes within a single nano-object. In this work, we explore two distinct sets of iron oxide-based nanospheres for their application as contrast agents in magnetic resonance imaging and as heating mediators in magnetic fluid hyperthermia. The nanoparticles were produced with the green microwave polyol-assisted method. The nanoparticles in the first set have a mean core diameter of 11 nm and are coated with polyacrylic acid (PAA), carboxymethyl-dextran (CM-D), or dimercaptosuccinic acid (DMSA). The second set has nanoparticles of a mean diameter of 14 nm, which are coated with PAA or CM-D. The longitudinal and transverse 1H-NMR nuclear relaxivities (r1,2) exhibit a field behavior that depends on the particle core size and on the coating. It is shown that the combination of size and coating is relevant to optimize the relaxometric efficiency, with the PAA coating being able to double the r2 efficiency for the smallest size. The heating release was evaluated under various combinations of external alternating magnetic fields, with frequency values ranging from 102.2 kHz to 971.2 kHz and amplitude values ranging from 7 mT to 40 mT. The results indicate that the heating efficiency is independent of the coating for both the 11 and 14 nm particles, while it is significantly higher for the samples of largest size. We conclude that the combination of size and coating (i.e., surface modifications) of the magnetic nanoparticles can play a crucial role in the relaxometric and heating properties of magnetic nanoparticles with core size of <15 nm.
- 16 May 2025
- Published by Royal Society of Chemistry (RSC) in Dalton Transactions
- Vol. 54 (22) , 9057-9068
Open AccessIron oxide nanospheres: dual functionality as MRI contrast agents and magnetic fluid hyperthermia therapeutics
Magnetic nanoparticles offer the possibility of combining diagnostic and therapeutic purposes within a single nano-object. In this work, we explore two distinct sets of iron oxide-based nanospheres for their application as contrast agents in magnetic resonance imaging and as heating mediators in magnetic fluid hyperthermia. The nanoparticles were produced with the green microwave polyol-assisted method. The nanoparticles in the first set have a mean core diameter of 11 nm and are coated with polyacrylic acid (PAA), carboxymethyl-dextran (CM-D), or dimercaptosuccinic acid (DMSA). The second set has nanoparticles of a mean diameter of 14 nm, which are coated with PAA or CM-D. The longitudinal and transverse 1H-NMR nuclear relaxivities (r1,2) exhibit a field behavior that depends on the particle core size and on the coating. It is shown that the combination of size and coating is relevant to optimize the relaxometric efficiency, with the PAA coating being able to double the r2 efficiency for the smallest size. The heating release was evaluated under various combinations of external alternating magnetic fields, with frequency values ranging from 102.2 kHz to 971.2 kHz and amplitude values ranging from 7 mT to 40 mT. The results indicate that the heating efficiency is independent of the coating for both the 11 and 14 nm particles, while it is significantly higher for the samples of largest size. We conclude that the combination of size and coating (i.e., surface modifications) of the magnetic nanoparticles can play a crucial role in the relaxometric and heating properties of magnetic nanoparticles with core size of <15 nm.
- Open Access
- 28 August 2024
- Published by Elsevier in Computer Methods and Programs in Biomedicine
- Vol. 256, 108399
Myo-regressor Deep Informed Neural NetwOrk (Myo-DINO) for fast MR parameters mapping in neuromuscular disorders
- 28 August 2024
- Published by Elsevier in Computer Methods and Programs in Biomedicine
- Vol. 256, 108399
Open AccessMyo-regressor Deep Informed Neural NetwOrk (Myo-DINO) for fast MR parameters mapping in neuromuscular disorders
- 1 September 2023
- Published by Morressier GmbH
Radiomic features analysis to automatically predict COVID-19 severity outcome by using the LungQuant segmentation software: a multi-center study
**Abstract text** Background: COVID-19 disease is a public health problem worldwide. Different studies proved that Computed Tomography (CT) bring | POSTER
- 1 September 2023
- Published by Morressier GmbH
Radiomic features analysis to automatically predict COVID-19 severity outcome by using the LungQuant segmentation software: a multi-center study
**Abstract text** Background: COVID-19 disease is a public health problem worldwide. Different studies proved that Computed Tomography (CT) bring | POSTER