Davide Esposito
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Davide Esposito has a total of 257 co-authors. Here are the top co-authors by number of shared publications:
Giovanni Pratesi
University of Genoa, Italy
15 shared publicationsRaffaele Pulli
13 shared publicationsCarlo Pratesi
9 shared publications- Walter Dorigo
University of Florence, IT
9 shared publications - Aaron Fargion
Vascular Surgery, Department of Cardiothoracic and Vascular Surgery, Careggi University Teaching Hospital, University of Florence, Florence, Italy
8 shared publications Aaron T. Fargion
8 shared publications
Latest Publications
- Open Access
- 5 November 2026
- Published by Georg Thieme Verlag KG in Acta Aorta
In Situ Laser Fenestration of the Left Subclavian Artery for TEVAR: A Systematic Review and Meta-Analysis
Objective To evaluate the outcomes after in situ laser fenestration of the left subclavian artery (LSA) for thoracic endovascular aortic repair (TEVAR). Methods The review followed the Preferred Reporting Items for Systematic Reviews and Meta-Analysis guidelines. The protocol was prospectively registered on PROSPERO (CRD420261457148). Data sources were the Cochrane Library, Embase, and MEDLINE. All studies reporting the outcomes of in situ laser fenestration of the LSA for TEVAR were eligible for inclusion. Quality assessment was performed using the Methodological Index for Non-Randomized Studies tool and the Grading of Recommendations Assessment, Development, and Evaluation (GRADE) system. A random-effects meta-analysis of proportions was conducted. Results Five studies encompassing 562 patients were included. The primary indication was type B aortic dissection (85%). The pooled technical success rate was 98.1% (95% confidence interval [CI], 96.6–99.2%). The pooled 30-day mortality was 2.1% (95% CI, 1.0–5.9%). The pooled incidence of target-vessel instability was 1.9% (95% CI, 0.3–4.5%), and the overall reintervention rate was 2.7% (95% CI, 0.4–6.4%). GRADE certainty was low to very low across outcomes. Conclusion LSA in situ laser fenestration demonstrates high technical success and favorable early clinical outcomes. Comparative trials against alternative endovascular strategies are required to establish its long-term durability and safety.
- 5 November 2026
- Published by Georg Thieme Verlag KG in Acta Aorta
Open AccessIn Situ Laser Fenestration of the Left Subclavian Artery for TEVAR: A Systematic Review and Meta-Analysis
Objective To evaluate the outcomes after in situ laser fenestration of the left subclavian artery (LSA) for thoracic endovascular aortic repair (TEVAR). Methods The review followed the Preferred Reporting Items for Systematic Reviews and Meta-Analysis guidelines. The protocol was prospectively registered on PROSPERO (CRD420261457148). Data sources were the Cochrane Library, Embase, and MEDLINE. All studies reporting the outcomes of in situ laser fenestration of the LSA for TEVAR were eligible for inclusion. Quality assessment was performed using the Methodological Index for Non-Randomized Studies tool and the Grading of Recommendations Assessment, Development, and Evaluation (GRADE) system. A random-effects meta-analysis of proportions was conducted. Results Five studies encompassing 562 patients were included. The primary indication was type B aortic dissection (85%). The pooled technical success rate was 98.1% (95% confidence interval [CI], 96.6–99.2%). The pooled 30-day mortality was 2.1% (95% CI, 1.0–5.9%). The pooled incidence of target-vessel instability was 1.9% (95% CI, 0.3–4.5%), and the overall reintervention rate was 2.7% (95% CI, 0.4–6.4%). GRADE certainty was low to very low across outcomes. Conclusion LSA in situ laser fenestration demonstrates high technical success and favorable early clinical outcomes. Comparative trials against alternative endovascular strategies are required to establish its long-term durability and safety.
- Open Access
- 29 September 2026
- Published by Elsevier in Journal of Vascular Surgery
Real-world outcomes of endoanchors in the prevention and treatment of proximal endograft failure in a multicenter registry
- 29 September 2026
- Published by Elsevier in Journal of Vascular Surgery
Open AccessReal-world outcomes of endoanchors in the prevention and treatment of proximal endograft failure in a multicenter registry
- 20 July 2026
- Published by Elsevier in Journal of Vascular Surgery
- Vol. 84 (2) , 552-554
An enhanced recovery protocol for open conversion after noninfected endovascular aneurysm repair failure
- 20 July 2026
- Published by Elsevier in Journal of Vascular Surgery
- Vol. 84 (2) , 552-554
An enhanced recovery protocol for open conversion after noninfected endovascular aneurysm repair failure
- Open Access
- 14 July 2026
- Published by Elsevier in JVS-Vascular Insights
- Vol. 4
Systematic review and meta-analysis of outcomes after endovascular aortic septotomy to facilitate the endovascular treatment of aortic dissections
- 14 July 2026
- Published by Elsevier in JVS-Vascular Insights
- Vol. 4
Open AccessSystematic review and meta-analysis of outcomes after endovascular aortic septotomy to facilitate the endovascular treatment of aortic dissections
- Open Access
- 12 July 2026
- Published by MDPI AG in Journal of Cardiovascular Development and Disease
- Vol. 13 (7) , 325
Preoperative Abdominal Aortic Aneurysm Diameter Is Associated with Long-Term Durability After Endovascular Aortic Aneurysm Repair: A Multicenter Real-World Italian Cohort Study
Objective: To assess whether baseline abdominal aortic aneurysm (AAA) diameter is associated with long-term durability after elective EVAR, after accounting for relevant anatomic differences. Methods: Consecutive patients undergoing elective EVAR for infrarenal fusiform AAA between 2011 and 2022 at four Italian centers were analyzed. Ruptured, saccular, and adjunctive proximal or distal procedures were excluded. Patients were stratified as AAA ≤ 50 mm or >50 mm. Outcomes included any endoleak, reintervention, aneurysm-related death, sac behavior, and all-cause mortality. Analyses used cumulative incidence functions, Fine–Gray competing-risk models, multivariable Cox regression, and propensity-score matching incorporating key anatomic variables. Results: Among 1505 patients, 499 (33.2%) had AAA ≤ 50 mm. Median follow-up was 49 months. Larger aneurysms showed higher 10-year cumulative incidence of any endoleak (33.9% vs. 15.8%, Gray p < 0.001), type 1a endoleak (16.5% vs. 6.1%, Gray p < 0.001), reintervention (24.7% vs. 16.2%, Gray p < 0.001), and aneurysm-related death (5.4% vs. 2.4%, Gray p = 0.028). In anatomy-adjusted multivariable Cox models, each 1 cm increase in diameter was associated with higher hazards of any endoleak (HR 1.22, 95% CI 1.11–1.34; p < 0.001), type 2 endoleak (HR 1.26, 95% CI 1.12–1.43; p < 0.001), reintervention (HR 1.19, 95% CI 1.07–1.32; p = 0.001), and aneurysm-related mortality (HR 1.46, 95% CI 1.19–1.81; p < 0.001). In propensity-score-matched analyses, AAA ≤ 50 mm was associated with lower hazards of any endoleak, HR 0.39, 95% CI 0.28–0.55; p < 0.001, and reintervention, HR 0.40, 95% CI 0.26–0.62; p < 0.001. Conclusions: Baseline AAA diameter adds prognostic information beyond standard anatomic features and may help tailor post-EVAR surveillance. What is new?: This multicenter real-world study shows that baseline abdominal aortic aneurysm diameter provides continuous prognostic information of clinical outcomes after elective EVAR. Larger preoperative diameter was associated with higher long-term risk of endoleak and reintervention, supporting the use of baseline sac size as one component of individualized post-EVAR surveillance planning.
- 12 July 2026
- Published by MDPI AG in Journal of Cardiovascular Development and Disease
- Vol. 13 (7) , 325
Open AccessPreoperative Abdominal Aortic Aneurysm Diameter Is Associated with Long-Term Durability After Endovascular Aortic Aneurysm Repair: A Multicenter Real-World Italian Cohort Study
Objective: To assess whether baseline abdominal aortic aneurysm (AAA) diameter is associated with long-term durability after elective EVAR, after accounting for relevant anatomic differences. Methods: Consecutive patients undergoing elective EVAR for infrarenal fusiform AAA between 2011 and 2022 at four Italian centers were analyzed. Ruptured, saccular, and adjunctive proximal or distal procedures were excluded. Patients were stratified as AAA ≤ 50 mm or >50 mm. Outcomes included any endoleak, reintervention, aneurysm-related death, sac behavior, and all-cause mortality. Analyses used cumulative incidence functions, Fine–Gray competing-risk models, multivariable Cox regression, and propensity-score matching incorporating key anatomic variables. Results: Among 1505 patients, 499 (33.2%) had AAA ≤ 50 mm. Median follow-up was 49 months. Larger aneurysms showed higher 10-year cumulative incidence of any endoleak (33.9% vs. 15.8%, Gray p < 0.001), type 1a endoleak (16.5% vs. 6.1%, Gray p < 0.001), reintervention (24.7% vs. 16.2%, Gray p < 0.001), and aneurysm-related death (5.4% vs. 2.4%, Gray p = 0.028). In anatomy-adjusted multivariable Cox models, each 1 cm increase in diameter was associated with higher hazards of any endoleak (HR 1.22, 95% CI 1.11–1.34; p < 0.001), type 2 endoleak (HR 1.26, 95% CI 1.12–1.43; p < 0.001), reintervention (HR 1.19, 95% CI 1.07–1.32; p = 0.001), and aneurysm-related mortality (HR 1.46, 95% CI 1.19–1.81; p < 0.001). In propensity-score-matched analyses, AAA ≤ 50 mm was associated with lower hazards of any endoleak, HR 0.39, 95% CI 0.28–0.55; p < 0.001, and reintervention, HR 0.40, 95% CI 0.26–0.62; p < 0.001. Conclusions: Baseline AAA diameter adds prognostic information beyond standard anatomic features and may help tailor post-EVAR surveillance. What is new?: This multicenter real-world study shows that baseline abdominal aortic aneurysm diameter provides continuous prognostic information of clinical outcomes after elective EVAR. Larger preoperative diameter was associated with higher long-term risk of endoleak and reintervention, supporting the use of baseline sac size as one component of individualized post-EVAR surveillance planning.
- 20 April 2026
- Published by SAGE Publications in Journal of Endovascular Therapy
Patient Selection and Technical Considerations for Electrocautery Septotomy in the Management of Aortic Dissection
Objective: Electrocautery septotomy has been proposed as an adjunctive technique during endovascular repair of aortic dissection with the aim of overcoming technical challenges associated with the presence of dual lumen. Methods: We retrospectively analyzed the outcomes of patients treated with electrocautery septotomy, at a single institution, between July 2023 and November 2024. Early outcomes included septotomy technical success, procedural technical success, 30-day mortality, and 30-day major adverse events. Late outcomes included overall survival, positive aortic remodeling, freedom from aortic-related reintervention, and freedom from target vessel instability. Results: Between July 2023 and November 2024, 15 consecutive patients were treated with electrocautery septotomy at a single center. The underlying disease was chronic dissection in 13 patients (86.6%), subacute residual aortic dissection in 1 patient (6.7%), and acute type B dissection in 1 patient (6.7%). The primary indication for treatment was a maximum aortic diameter ≥5.5 cm in 8 patients (53.3%) and urgent repair in 7 patients (46.7%) due to pain in 4 patients (26.6%), malperfusion in 2 patients (13.3%), and aortic rupture in 1 patient (6.7%). Septotomy technical success was obtained in all the patients (100%), with full expansion of the true lumen. No aortic lesions, target vessels occlusion, or distal embolization were reported. Procedural technical success was 86.7%. Peri-operative major adverse events occurred in 3 patients (20%), with 1 death (6.7%). During follow-up, 1 additional non-aorta-related death was registered, and 2 reinterventions were performed. Positive aortic remodeling was observed in 78.6% of patients. Conclusions: Electrocautery septotomy results in being valuable technique to address technical challenges in the endovascular treatment of postdissection thoracoabdominal aneurysms. Careful patient selection and tailored technical adjustments can further enhance the procedure success. Clinical Impact: This study contributes to the growing body of evidence supporting electrocautery septotomy as a effective adjuntive technique during endovascular repair of post-dissection thoraco-abdominal aneurysm. However, it also underscores the limitations related to patient selection, highlighting the importance of careful pre-procedural evaluation to identify appropriate candidates and optimize clinical outcomes.
- 20 April 2026
- Published by SAGE Publications in Journal of Endovascular Therapy
Patient Selection and Technical Considerations for Electrocautery Septotomy in the Management of Aortic Dissection
Objective: Electrocautery septotomy has been proposed as an adjunctive technique during endovascular repair of aortic dissection with the aim of overcoming technical challenges associated with the presence of dual lumen. Methods: We retrospectively analyzed the outcomes of patients treated with electrocautery septotomy, at a single institution, between July 2023 and November 2024. Early outcomes included septotomy technical success, procedural technical success, 30-day mortality, and 30-day major adverse events. Late outcomes included overall survival, positive aortic remodeling, freedom from aortic-related reintervention, and freedom from target vessel instability. Results: Between July 2023 and November 2024, 15 consecutive patients were treated with electrocautery septotomy at a single center. The underlying disease was chronic dissection in 13 patients (86.6%), subacute residual aortic dissection in 1 patient (6.7%), and acute type B dissection in 1 patient (6.7%). The primary indication for treatment was a maximum aortic diameter ≥5.5 cm in 8 patients (53.3%) and urgent repair in 7 patients (46.7%) due to pain in 4 patients (26.6%), malperfusion in 2 patients (13.3%), and aortic rupture in 1 patient (6.7%). Septotomy technical success was obtained in all the patients (100%), with full expansion of the true lumen. No aortic lesions, target vessels occlusion, or distal embolization were reported. Procedural technical success was 86.7%. Peri-operative major adverse events occurred in 3 patients (20%), with 1 death (6.7%). During follow-up, 1 additional non-aorta-related death was registered, and 2 reinterventions were performed. Positive aortic remodeling was observed in 78.6% of patients. Conclusions: Electrocautery septotomy results in being valuable technique to address technical challenges in the endovascular treatment of postdissection thoracoabdominal aneurysms. Careful patient selection and tailored technical adjustments can further enhance the procedure success. Clinical Impact: This study contributes to the growing body of evidence supporting electrocautery septotomy as a effective adjuntive technique during endovascular repair of post-dissection thoraco-abdominal aneurysm. However, it also underscores the limitations related to patient selection, highlighting the importance of careful pre-procedural evaluation to identify appropriate candidates and optimize clinical outcomes.
- 1 April 2026
- Published by Edizioni Minerva Medica
In-situ fenestrated versus physician-modified endografts in the endovascular treatment of thoracic and complex abdominal aortic pathologies in modern vascular surgery
Article: In-situ fenestrated versus physician-modified endografts in the endovascular treatment of thoracic and complex abdominal aortic pathologies in modern vascular surgery - The Journal of Cardiovascular Surgery 2026 Apr 22 - Minerva Medica - Journals
- 1 April 2026
- Published by Edizioni Minerva Medica
In-situ fenestrated versus physician-modified endografts in the endovascular treatment of thoracic and complex abdominal aortic pathologies in modern vascular surgery
Article: In-situ fenestrated versus physician-modified endografts in the endovascular treatment of thoracic and complex abdominal aortic pathologies in modern vascular surgery - The Journal of Cardiovascular Surgery 2026 Apr 22 - Minerva Medica - Journals
- 23 March 2026
- Published by SAGE Publications in Asian Cardiovascular and Thoracic Annals
- Vol. 34 (4) , 355-362
Endovascular aortic repair with the custom-made cook fenestrated device for the treatment of complex abdominal aortic aneurysms
Background: Fenestrated endovascular aneurysm repair (FEVAR) has become an essential option for the treatment of complex abdominal aortic aneurysms (AAA). While technological advances and growing operator experience have expanded its applicability, outcomes remain heterogeneous across centers and patient subsets. Evaluating real-world results is crucial to better define the effectiveness, safety, and durability of FEVAR in current practice. Methods: This is a single-center, retrospective, observational study. Consecutive patients treated with FEVAR for complex AAA with a custom-made Cook device from January 2015 to October 2025 were included. Outcomes accessed included technical success, early major systemic complications, overall survival, freedom from reinterventions, target vessel instability, endoleaks, and sac expansion. Results: Sixty-four consecutive patients were treated with FEVAR Cook, of which 23 (35.9%) for juxtarenal AAA, 35 (54.7%) pararenal AAA and 6 (9.4%) thoraco-abdominal type IV aortic aneurysm. All but three patients were treated electively (95.3%). Two hundred twenty-two target vessels were successfully cannulated and treated with a bridging stent. Technical success was 98.4%. Early major systemic complications rate was 14.1%. Median follow-up was 29.5 months (IQR 47). Overall survival estimates at 1 and 4 years were 86.9% and 71.3%, respectively. Estimates at 4 years of freedom from reinterventions and target vessel instability were 90.9% and 93.8%, respectively. Freedom from type I/Ic and III/IIIc endoleak was 95.3% at 4 years. Sac regression, stability, and expansion at follow-up occurred in 29.5%, 63.9%, and 6.6%, respectively. Conclusions: FEVAR emerges as an appropriate and effective treatment option for complex aortic aneurysms. In our experience, the procedure provides high technical success and durable target-vessel preservation, with very satisfactory outcomes even at mid- to long-term follow-up.
- 23 March 2026
- Published by SAGE Publications in Asian Cardiovascular and Thoracic Annals
- Vol. 34 (4) , 355-362
Endovascular aortic repair with the custom-made cook fenestrated device for the treatment of complex abdominal aortic aneurysms
Background: Fenestrated endovascular aneurysm repair (FEVAR) has become an essential option for the treatment of complex abdominal aortic aneurysms (AAA). While technological advances and growing operator experience have expanded its applicability, outcomes remain heterogeneous across centers and patient subsets. Evaluating real-world results is crucial to better define the effectiveness, safety, and durability of FEVAR in current practice. Methods: This is a single-center, retrospective, observational study. Consecutive patients treated with FEVAR for complex AAA with a custom-made Cook device from January 2015 to October 2025 were included. Outcomes accessed included technical success, early major systemic complications, overall survival, freedom from reinterventions, target vessel instability, endoleaks, and sac expansion. Results: Sixty-four consecutive patients were treated with FEVAR Cook, of which 23 (35.9%) for juxtarenal AAA, 35 (54.7%) pararenal AAA and 6 (9.4%) thoraco-abdominal type IV aortic aneurysm. All but three patients were treated electively (95.3%). Two hundred twenty-two target vessels were successfully cannulated and treated with a bridging stent. Technical success was 98.4%. Early major systemic complications rate was 14.1%. Median follow-up was 29.5 months (IQR 47). Overall survival estimates at 1 and 4 years were 86.9% and 71.3%, respectively. Estimates at 4 years of freedom from reinterventions and target vessel instability were 90.9% and 93.8%, respectively. Freedom from type I/Ic and III/IIIc endoleak was 95.3% at 4 years. Sac regression, stability, and expansion at follow-up occurred in 29.5%, 63.9%, and 6.6%, respectively. Conclusions: FEVAR emerges as an appropriate and effective treatment option for complex aortic aneurysms. In our experience, the procedure provides high technical success and durable target-vessel preservation, with very satisfactory outcomes even at mid- to long-term follow-up.
- 29 November 2025
- Published by Elsevier in European Journal of Vascular and Endovascular Surgery
- Vol. 72 (5) , e105
Refining Post-Endovascular Aneurysm Repair Surveillance by Tracing the Path Towards a Truly Low Risk Definition
- 29 November 2025
- Published by Elsevier in European Journal of Vascular and Endovascular Surgery
- Vol. 72 (5) , e105
Refining Post-Endovascular Aneurysm Repair Surveillance by Tracing the Path Towards a Truly Low Risk Definition