Haya Jamali
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Haya Jamali has a total of 47 co-authors. Here are the top co-authors by number of shared publications:
- Andrew M. Luks
University of Washington
3 shared publications - Jonathan Anthony Ellman
Yale University
2 shared publications Adele Riccardi
Department of Biomedical Engineering, Yale University, New Haven, CT 06511, USA
1 shared publicationAlexandra S. Piotrowski-Daspit
Department of Biomedical Engineering, Yale University, New Haven, CT 06511, USA
1 shared publication- Amy K. Dickey
Harvard Medical School
1 shared publication Anisha Gupta
Department of Therapeutic Radiology, Yale School of Medicine, New Haven, CT 06520, USA
1 shared publication
Latest Publications
- 1 July 2025
- Published by Oxford University Press (OUP) in Annals of the American Thoracic Society
- Vol. 22 (7) , 1079-1083
The Right Diagnosis Comes to Those Who Measure Correctly
- 1 July 2025
- Published by Oxford University Press (OUP) in Annals of the American Thoracic Society
- Vol. 22 (7) , 1079-1083
The Right Diagnosis Comes to Those Who Measure Correctly
- 5 August 2024
- Published by Elsevier in Journal of Cystic Fibrosis
- Vol. 24 (1) , 142-148
Next generation triplex-forming PNAs for site-specific genome editing of the F508del CFTR mutation
- 5 August 2024
- Published by Elsevier in Journal of Cystic Fibrosis
- Vol. 24 (1) , 142-148
Next generation triplex-forming PNAs for site-specific genome editing of the F508del CFTR mutation
- 1 April 2024
- Published by Oxford University Press (OUP) in Annals of the American Thoracic Society
- Vol. 21 (4) , 663-668
What’s the Difference Anyway?
- 1 April 2024
- Published by Oxford University Press (OUP) in Annals of the American Thoracic Society
- Vol. 21 (4) , 663-668
What’s the Difference Anyway?
- 1 April 2023
- Published by Oxford University Press (OUP) in Annals of the American Thoracic Society
- Vol. 20 (4) , 605-608
Don’t Be So Dense!
- 1 April 2023
- Published by Oxford University Press (OUP) in Annals of the American Thoracic Society
- Vol. 20 (4) , 605-608
Don’t Be So Dense!
- Top Cited Papers
- 1 December 2022
- Published by Oxford University Press (OUP) in Annals of the American Thoracic Society
- Vol. 19 (12) , 1951-1964
Racial Disparity in Oxygen Saturation Measurements by Pulse Oximetry: Evidence and Implications
The pulse oximeter is a ubiquitous clinical tool used to estimate blood oxygen concentrations. However, decreased accuracy of pulse oximetry in patients with dark skin tones has been demonstrated since as early as 1985. Most commonly, pulse oximeters may overestimate the true oxygen saturation in individuals with dark skin tones, leading to higher rates of occult hypoxemia (i.e., clinically unrecognized low blood oxygen saturation). Overestimation of oxygen saturation in patients with dark skin tones has serious clinical implications, as these patients may receive insufficiently rigorous medical care when pulse oximeter measurements suggest that their oxygen saturation is higher than the true value. Recent studies have linked pulse oximeter inaccuracy to worse clinical outcomes, suggesting that pulse oximeter inaccuracy contributes to known racial health disparities. The magnitude of device inaccuracy varies by pulse oximeter manufacturer, sensor type, and arterial oxygen saturation. The underlying reasons for decreased pulse oximeter accuracy for individuals with dark skin tones may be related to failure to control for increased absorption of red light by melanin during device development and insufficient inclusion of individuals with dark skin tones during device calibration. Inadequate regulatory standards for device approval may also play a role in decreased accuracy. Awareness of potential pulse oximeter limitations is an important step for providers and may encourage the consideration of additional clinical information for management decisions. Ultimately, stricter regulatory requirements for oximeter approval and increased manufacturer transparency regarding device performance are required to mitigate this racial bias.
- 1 December 2022
- Published by Oxford University Press (OUP) in Annals of the American Thoracic Society
- Vol. 19 (12) , 1951-1964
Top Cited PapersRacial Disparity in Oxygen Saturation Measurements by Pulse Oximetry: Evidence and Implications
The pulse oximeter is a ubiquitous clinical tool used to estimate blood oxygen concentrations. However, decreased accuracy of pulse oximetry in patients with dark skin tones has been demonstrated since as early as 1985. Most commonly, pulse oximeters may overestimate the true oxygen saturation in individuals with dark skin tones, leading to higher rates of occult hypoxemia (i.e., clinically unrecognized low blood oxygen saturation). Overestimation of oxygen saturation in patients with dark skin tones has serious clinical implications, as these patients may receive insufficiently rigorous medical care when pulse oximeter measurements suggest that their oxygen saturation is higher than the true value. Recent studies have linked pulse oximeter inaccuracy to worse clinical outcomes, suggesting that pulse oximeter inaccuracy contributes to known racial health disparities. The magnitude of device inaccuracy varies by pulse oximeter manufacturer, sensor type, and arterial oxygen saturation. The underlying reasons for decreased pulse oximeter accuracy for individuals with dark skin tones may be related to failure to control for increased absorption of red light by melanin during device development and insufficient inclusion of individuals with dark skin tones during device calibration. Inadequate regulatory standards for device approval may also play a role in decreased accuracy. Awareness of potential pulse oximeter limitations is an important step for providers and may encourage the consideration of additional clinical information for management decisions. Ultimately, stricter regulatory requirements for oximeter approval and increased manufacturer transparency regarding device performance are required to mitigate this racial bias.
- 25 August 2020
- Published by American Association for the Advancement of Science (AAAS) in Science Signaling
- Vol. 13 (646)
An allosteric site on MKP5 reveals a strategy for small-molecule inhibition
A small-molecule inhibitor of the phosphatase MKP5 identifies an allosteric site that enables specific targeting.
- 25 August 2020
- Published by American Association for the Advancement of Science (AAAS) in Science Signaling
- Vol. 13 (646)
An allosteric site on MKP5 reveals a strategy for small-molecule inhibition
A small-molecule inhibitor of the phosphatase MKP5 identifies an allosteric site that enables specific targeting.
- Open Access
- 5 March 2015
- Published by American Chemical Society (ACS) in Journal of the American Chemical Society
- Vol. 137 (10) , 3616-3621
Identification of Multiple Structurally Distinct, Nonpeptidic Small Molecule Inhibitors of Protein Arginine Deiminase 3 Using a Substrate-Based Fragment Method
The protein arginine deiminases (PADs) are a family of enzymes that catalyze the post-translational hydrolytic deimination of arginine residues. Four different enzymologically active PAD subtypes have been characterized and exhibit tissue-specific expression and association with a number of different diseases. In this Article we describe the development of an approach for the reliable discovery of low molecular weight, nonpeptidic fragment substrates of the PADs that then can be optimized and converted to mechanism-based irreversible PAD inhibitors. The approach is demonstrated by the development of potent and selective inhibitors of PAD3, a PAD subtype implicated in the neurodegenerative response to spinal cord injury. Multiple structurally distinct inhibitors were identified with the most potent inhibitors having >10,000 min–1 M–1 kinact/KI values and ≥10-fold selectivity for PAD3 over PADs 1, 2, and 4.
- 5 March 2015
- Published by American Chemical Society (ACS) in Journal of the American Chemical Society
- Vol. 137 (10) , 3616-3621
Open AccessIdentification of Multiple Structurally Distinct, Nonpeptidic Small Molecule Inhibitors of Protein Arginine Deiminase 3 Using a Substrate-Based Fragment Method
The protein arginine deiminases (PADs) are a family of enzymes that catalyze the post-translational hydrolytic deimination of arginine residues. Four different enzymologically active PAD subtypes have been characterized and exhibit tissue-specific expression and association with a number of different diseases. In this Article we describe the development of an approach for the reliable discovery of low molecular weight, nonpeptidic fragment substrates of the PADs that then can be optimized and converted to mechanism-based irreversible PAD inhibitors. The approach is demonstrated by the development of potent and selective inhibitors of PAD3, a PAD subtype implicated in the neurodegenerative response to spinal cord injury. Multiple structurally distinct inhibitors were identified with the most potent inhibitors having >10,000 min–1 M–1 kinact/KI values and ≥10-fold selectivity for PAD3 over PADs 1, 2, and 4.