Jingwei Wu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Jingwei Wu has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
- Farzad Mashayek
Department of Aerospace and Mechanical Engineering, University of Arizona , Tucson, Arizona 85721
10 shared publications - Jevon Plog
Department of Mechanical and Industrial Engineering, University of Illinois at Chicago, 842 W. Taylor St., Chicago, Illinois 60607-7022, USA
8 shared publications - Lyndon F. Cooper
School of Dentistry, Virginia Commonwealth University, Richmond, VA, USA
8 shared publications - Yasmin J. Dias
Department of Mechanical and Industrial Engineering University of Illinois at Chicago (UIC) Chicago Illinois USA
8 shared publications - Alexander L. Yarin
Department of Mechanical and Industrial Engineering, University of Illinois Chicago, 842 W. Taylor St., Chicago, Illinois 60607-7022, United States
5 shared publications - Abhilash Sankaran
University of the Bundeswehr Munich, Institute of Fluid Mechanics and Aerodynamics, Werner-Heisenberg-Weg 39, Neubiberg 85577, Germany
2 shared publications
Latest Publications
- Open Access
- 29 November 2024
- Published by Wiley in Macromolecular Rapid Communications
- Vol. 46 (13) , e2400861
Adaptable Intelligent Filters of Dual Thermo‐ and pH‐ Responsive Filter Material
In this study, the development of novel pH‐responsive and dual thermo‐ and pH‐responsive filter materials is described. The dual‐responsive system combines poly(N‐isopropylacrylamide) (PNIPAM) for temperature sensitivity and poly(acrylic acid) (PAA) for pH responsiveness, which offers dynamic filtration capabilities tailored to environmental changes. PNIPAM is a thermo‐responsive polymer that undergoes significant conformational changes in response to temperature variations. The present work integrates PNIPAM's temperature sensitivity with the pH‐responsive properties of PAA, a versatile polymer widely recognized for its ability to change its conformation in response to pH variations. The dual materials developed here undergo conformational changes at specific temperatures and pH levels, modifying their hydrophilicity, pore size, and permeability. In particular, when exposed to higher temperatures, PNIPAM transitions from a hydrated, expanded state to a dehydrated, collapsed state, directly influencing the flow rate and selectivity of the filter medium that comprises it. On the other hand, PAA responds to pH changes by ionizing or deprotonating, causing swelling or shrinkage that alters the filtration performance of the media with embedded PAA. This dual responsiveness allows for the development of advanced filtration systems that can adapt to varying environmental conditions, optimize the capture of specific contaminants, and reduce fouling.
- 29 November 2024
- Published by Wiley in Macromolecular Rapid Communications
- Vol. 46 (13) , e2400861
Open AccessAdaptable Intelligent Filters of Dual Thermo‐ and pH‐ Responsive Filter Material
In this study, the development of novel pH‐responsive and dual thermo‐ and pH‐responsive filter materials is described. The dual‐responsive system combines poly(N‐isopropylacrylamide) (PNIPAM) for temperature sensitivity and poly(acrylic acid) (PAA) for pH responsiveness, which offers dynamic filtration capabilities tailored to environmental changes. PNIPAM is a thermo‐responsive polymer that undergoes significant conformational changes in response to temperature variations. The present work integrates PNIPAM's temperature sensitivity with the pH‐responsive properties of PAA, a versatile polymer widely recognized for its ability to change its conformation in response to pH variations. The dual materials developed here undergo conformational changes at specific temperatures and pH levels, modifying their hydrophilicity, pore size, and permeability. In particular, when exposed to higher temperatures, PNIPAM transitions from a hydrated, expanded state to a dehydrated, collapsed state, directly influencing the flow rate and selectivity of the filter medium that comprises it. On the other hand, PAA responds to pH changes by ionizing or deprotonating, causing swelling or shrinkage that alters the filtration performance of the media with embedded PAA. This dual responsiveness allows for the development of advanced filtration systems that can adapt to varying environmental conditions, optimize the capture of specific contaminants, and reduce fouling.
- Open Access
- 27 February 2024
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 135 (8)
Adaptable intelligent filters based on nanotextured nonwoven membranes containing water-insoluble hydrogels
The work demonstrates, for the first time, thermo-responsive, water-insoluble, hydrogel-based, nano-fibrous filter media comprised of copolymers of N-isopropylacrylamide (NIPAM) and methyl methacrylate formed by electrospinning. Moreover, a comprehensive novel physical explanation of all aspects responsible for the physical mechanisms resulting in the thermo-responsive regulation of the water flow rate and an enhanced interception of nanoparticles by such filter membranes is given. They are the wettable-non-wettable transition, pore, and fiber-size changes, as well as a diminishing filter thickness at the lower critical solution temperature (LCST) of the copolymers developed here, which interplay with a significant reduction in the water viscosity with temperature. Poly(N-isopropylacrylamide) (PNIPAM) hydrogel is an attractive material because of its thermo-responsive properties. Its wettability changes with water temperature. This characteristic holds great promise for the development of advanced filter media and related responsive materials. In this study, PNIPAM hydrogels were designed and transformed into filter membranes for applications in water filtration in biomedical and other related systems. These thermo-responsive filter membranes offer the potential for enhanced filtration efficiency, selectivity, and the overall system performance. Here, two different procedures were adopted to form water-insoluble thermo-responsive filter media based on PNIPAM hydrogels. The PNIPAM-based hydrogels were electrospun, resulting in the formation of thermo-responsive water-insoluble nanofiber membranes. These membranes underwent a series of comprehensive experiments to assess their performance and characteristics, including mass loss, water droplets for the wettability assessment, filtration tests, shrinkage measurements, and microscopic observations. These diverse experiments yield a full understanding of the PNIPAM-based nanofiber membranes’ properties and their potential applications.
- 27 February 2024
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 135 (8)
Open AccessAdaptable intelligent filters based on nanotextured nonwoven membranes containing water-insoluble hydrogels
The work demonstrates, for the first time, thermo-responsive, water-insoluble, hydrogel-based, nano-fibrous filter media comprised of copolymers of N-isopropylacrylamide (NIPAM) and methyl methacrylate formed by electrospinning. Moreover, a comprehensive novel physical explanation of all aspects responsible for the physical mechanisms resulting in the thermo-responsive regulation of the water flow rate and an enhanced interception of nanoparticles by such filter membranes is given. They are the wettable-non-wettable transition, pore, and fiber-size changes, as well as a diminishing filter thickness at the lower critical solution temperature (LCST) of the copolymers developed here, which interplay with a significant reduction in the water viscosity with temperature. Poly(N-isopropylacrylamide) (PNIPAM) hydrogel is an attractive material because of its thermo-responsive properties. Its wettability changes with water temperature. This characteristic holds great promise for the development of advanced filter media and related responsive materials. In this study, PNIPAM hydrogels were designed and transformed into filter membranes for applications in water filtration in biomedical and other related systems. These thermo-responsive filter membranes offer the potential for enhanced filtration efficiency, selectivity, and the overall system performance. Here, two different procedures were adopted to form water-insoluble thermo-responsive filter media based on PNIPAM hydrogels. The PNIPAM-based hydrogels were electrospun, resulting in the formation of thermo-responsive water-insoluble nanofiber membranes. These membranes underwent a series of comprehensive experiments to assess their performance and characteristics, including mass loss, water droplets for the wettability assessment, filtration tests, shrinkage measurements, and microscopic observations. These diverse experiments yield a full understanding of the PNIPAM-based nanofiber membranes’ properties and their potential applications.
- 27 November 2021
- Published by Elsevier in Journal of Membrane Science
- Vol. 644, 120138
Electrospun membranes filtering 100 nm particles from air flow by means of the van der Waals and Coulomb forces
- 27 November 2021
- Published by Elsevier in Journal of Membrane Science
- Vol. 644, 120138
Electrospun membranes filtering 100 nm particles from air flow by means of the van der Waals and Coulomb forces
- 1 June 2021
- Published by AIP Publishing in Physics of Fluids
- Vol. 33 (6) , 062101
Drop impact onto polarized dielectric surface for controlled coating
Control of surface wettability by means of electrowetting-on-dielectric (EWOD) is among the most effective methods of active enhancement of surface wettability. Here, electrohydrodynamics of drop impact onto a dielectric surface with electrodes embedded in the dielectric (or aligned and attached to it) is experimentally investigated. Drop impact of different liquids (water, n-butanol, and motor oil) onto different substrates (stretched Teflon, parafilm, and polypropylene) is studied. Water drop impact onto stretched Teflon (the only Teflon which revealed significant electrowetting) and un-stretched parafilm surfaces is studied in detail. The results for water drop impact indicate that drop spreading on such non-wettable surfaces can be significantly enhanced by the electric field application. In particular, water drop rebound can be suppressed by the electric force. Furthermore, impact dynamics and spreading of hydrocarbon liquids with electric field are explored. Partial suppression of splash phenomena was also observed with the application of the electric field in addition to enhancement of spreading. In addition, the experimental results for water drops are compared with the Cahn−Hilliard−Navier−Stokes (CHNS) simulations for static contact angles and drop impact dynamics, and the results are in close agreement for water drops. This study demonstrates that electrowetting-on-dielectric holds great promise for coating and spraying technologies.
- 1 June 2021
- Published by AIP Publishing in Physics of Fluids
- Vol. 33 (6) , 062101
Drop impact onto polarized dielectric surface for controlled coating
Control of surface wettability by means of electrowetting-on-dielectric (EWOD) is among the most effective methods of active enhancement of surface wettability. Here, electrohydrodynamics of drop impact onto a dielectric surface with electrodes embedded in the dielectric (or aligned and attached to it) is experimentally investigated. Drop impact of different liquids (water, n-butanol, and motor oil) onto different substrates (stretched Teflon, parafilm, and polypropylene) is studied. Water drop impact onto stretched Teflon (the only Teflon which revealed significant electrowetting) and un-stretched parafilm surfaces is studied in detail. The results for water drop impact indicate that drop spreading on such non-wettable surfaces can be significantly enhanced by the electric field application. In particular, water drop rebound can be suppressed by the electric force. Furthermore, impact dynamics and spreading of hydrocarbon liquids with electric field are explored. Partial suppression of splash phenomena was also observed with the application of the electric field in addition to enhancement of spreading. In addition, the experimental results for water drops are compared with the Cahn−Hilliard−Navier−Stokes (CHNS) simulations for static contact angles and drop impact dynamics, and the results are in close agreement for water drops. This study demonstrates that electrowetting-on-dielectric holds great promise for coating and spraying technologies.
- 1 April 2021
- Published by AIP Publishing in Physics of Fluids
- Vol. 33 (4) , 042012
Water interaction with dielectric surface: A combined ab initio modeling and experimental study
A combined ab initio modeling and experimental study of water adsorption on a dry hydrophobic dielectric surface is presented. This is an important phenomenon for controlled droplet deposition in various technological applications. The ab initio density functional theory calculations are performed to reveal the dominant water adsorption sites, energetics, and the electron density profile on Teflon and parafilm surfaces. Several surface states such as stretched, nondefective, and defective are considered for water adsorption studies. It is revealed that stretching of nondefective surface leads to weaker water adsorption compared to an unstretched surface. Accordingly, such stretching makes the surface more hydrophobic as revealed by the electron density profile. The introduction of random defects into Teflon and parafilm surfaces results in an increase in water adsorption energy leading, in some cases, to practically hydrophilic interactions. These findings are in good agreement with the present measurements of static contact angle on prestretched Teflon and parafilm samples, where stretching not only elongates interatomic bonds but also changes the surface roughness. Thus, the present combined modeling and experimental study allows for a mechanistic interpretation of the reasons behind the change of wettability of dry hydrophobic surfaces.
- 1 April 2021
- Published by AIP Publishing in Physics of Fluids
- Vol. 33 (4) , 042012
Water interaction with dielectric surface: A combined ab initio modeling and experimental study
A combined ab initio modeling and experimental study of water adsorption on a dry hydrophobic dielectric surface is presented. This is an important phenomenon for controlled droplet deposition in various technological applications. The ab initio density functional theory calculations are performed to reveal the dominant water adsorption sites, energetics, and the electron density profile on Teflon and parafilm surfaces. Several surface states such as stretched, nondefective, and defective are considered for water adsorption studies. It is revealed that stretching of nondefective surface leads to weaker water adsorption compared to an unstretched surface. Accordingly, such stretching makes the surface more hydrophobic as revealed by the electron density profile. The introduction of random defects into Teflon and parafilm surfaces results in an increase in water adsorption energy leading, in some cases, to practically hydrophilic interactions. These findings are in good agreement with the present measurements of static contact angle on prestretched Teflon and parafilm samples, where stretching not only elongates interatomic bonds but also changes the surface roughness. Thus, the present combined modeling and experimental study allows for a mechanistic interpretation of the reasons behind the change of wettability of dry hydrophobic surfaces.
- 25 August 2020
- Published by AIP Publishing
- Vol. 32 (8) , 083111
10.1063/5.0021476.7
The aerosol transmissibility of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) has impacted the delivery of health care and essentially stopped the provision of medical and dental therapies. Dentistry uses rotary, ultrasonic, and laser-based instruments that produce water-based aerosols in the daily, routine treatment of patients. Abundant aerosols are generated, which reach health care workers and other patients. Viruses, including SARS-CoV-2 virus and related coronavirus disease (COVID-19) pandemic, continued expansion throughout the USA and the world. The virus is spread by both droplet (visible drops) and aerosol (practically invisible drops) transmission. The generation of aerosols in dentistry—an unavoidable part of most dental treatments—creates a high-risk situation. The US Centers for Disease Control and The Occupational Safety and Health Administration consider dental procedures to be of “highest risk” in the potential spreading of SARS-CoV-2 and other respiratory viruses. There are several ways to reduce or eliminate the virus: (i) cease or postpone dentistry (public and personal health risk), (ii) screen patients immediately prior to dental treatment (by appropriate testing, if any), (iii) block/remove the virus containing aerosol by engineering controls together with stringent personal protective equipment use. The present work takes a novel, fourth approach. By altering the physical response of water to the rotary or ultrasonic forces that are used in dentistry, the generation of aerosol particles and the distance any aerosol may spread beyond the point of generation can be markedly suppressed or completely eliminated in comparison to water for both the ultrasonic scaler and dental handpiece.
- 25 August 2020
- Published by AIP Publishing
- Vol. 32 (8) , 083111
10.1063/5.0021476.7
The aerosol transmissibility of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) has impacted the delivery of health care and essentially stopped the provision of medical and dental therapies. Dentistry uses rotary, ultrasonic, and laser-based instruments that produce water-based aerosols in the daily, routine treatment of patients. Abundant aerosols are generated, which reach health care workers and other patients. Viruses, including SARS-CoV-2 virus and related coronavirus disease (COVID-19) pandemic, continued expansion throughout the USA and the world. The virus is spread by both droplet (visible drops) and aerosol (practically invisible drops) transmission. The generation of aerosols in dentistry—an unavoidable part of most dental treatments—creates a high-risk situation. The US Centers for Disease Control and The Occupational Safety and Health Administration consider dental procedures to be of “highest risk” in the potential spreading of SARS-CoV-2 and other respiratory viruses. There are several ways to reduce or eliminate the virus: (i) cease or postpone dentistry (public and personal health risk), (ii) screen patients immediately prior to dental treatment (by appropriate testing, if any), (iii) block/remove the virus containing aerosol by engineering controls together with stringent personal protective equipment use. The present work takes a novel, fourth approach. By altering the physical response of water to the rotary or ultrasonic forces that are used in dentistry, the generation of aerosol particles and the distance any aerosol may spread beyond the point of generation can be markedly suppressed or completely eliminated in comparison to water for both the ultrasonic scaler and dental handpiece.
- 25 August 2020
- Published by AIP Publishing
- Vol. 32 (8) , 083111
10.1063/5.0021476.4
The aerosol transmissibility of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) has impacted the delivery of health care and essentially stopped the provision of medical and dental therapies. Dentistry uses rotary, ultrasonic, and laser-based instruments that produce water-based aerosols in the daily, routine treatment of patients. Abundant aerosols are generated, which reach health care workers and other patients. Viruses, including SARS-CoV-2 virus and related coronavirus disease (COVID-19) pandemic, continued expansion throughout the USA and the world. The virus is spread by both droplet (visible drops) and aerosol (practically invisible drops) transmission. The generation of aerosols in dentistry—an unavoidable part of most dental treatments—creates a high-risk situation. The US Centers for Disease Control and The Occupational Safety and Health Administration consider dental procedures to be of “highest risk” in the potential spreading of SARS-CoV-2 and other respiratory viruses. There are several ways to reduce or eliminate the virus: (i) cease or postpone dentistry (public and personal health risk), (ii) screen patients immediately prior to dental treatment (by appropriate testing, if any), (iii) block/remove the virus containing aerosol by engineering controls together with stringent personal protective equipment use. The present work takes a novel, fourth approach. By altering the physical response of water to the rotary or ultrasonic forces that are used in dentistry, the generation of aerosol particles and the distance any aerosol may spread beyond the point of generation can be markedly suppressed or completely eliminated in comparison to water for both the ultrasonic scaler and dental handpiece.
- 25 August 2020
- Published by AIP Publishing
- Vol. 32 (8) , 083111
10.1063/5.0021476.4
The aerosol transmissibility of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) has impacted the delivery of health care and essentially stopped the provision of medical and dental therapies. Dentistry uses rotary, ultrasonic, and laser-based instruments that produce water-based aerosols in the daily, routine treatment of patients. Abundant aerosols are generated, which reach health care workers and other patients. Viruses, including SARS-CoV-2 virus and related coronavirus disease (COVID-19) pandemic, continued expansion throughout the USA and the world. The virus is spread by both droplet (visible drops) and aerosol (practically invisible drops) transmission. The generation of aerosols in dentistry—an unavoidable part of most dental treatments—creates a high-risk situation. The US Centers for Disease Control and The Occupational Safety and Health Administration consider dental procedures to be of “highest risk” in the potential spreading of SARS-CoV-2 and other respiratory viruses. There are several ways to reduce or eliminate the virus: (i) cease or postpone dentistry (public and personal health risk), (ii) screen patients immediately prior to dental treatment (by appropriate testing, if any), (iii) block/remove the virus containing aerosol by engineering controls together with stringent personal protective equipment use. The present work takes a novel, fourth approach. By altering the physical response of water to the rotary or ultrasonic forces that are used in dentistry, the generation of aerosol particles and the distance any aerosol may spread beyond the point of generation can be markedly suppressed or completely eliminated in comparison to water for both the ultrasonic scaler and dental handpiece.
- 25 August 2020
- Published by AIP Publishing
- Vol. 32 (8) , 083111
10.1063/5.0021476.6
The aerosol transmissibility of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) has impacted the delivery of health care and essentially stopped the provision of medical and dental therapies. Dentistry uses rotary, ultrasonic, and laser-based instruments that produce water-based aerosols in the daily, routine treatment of patients. Abundant aerosols are generated, which reach health care workers and other patients. Viruses, including SARS-CoV-2 virus and related coronavirus disease (COVID-19) pandemic, continued expansion throughout the USA and the world. The virus is spread by both droplet (visible drops) and aerosol (practically invisible drops) transmission. The generation of aerosols in dentistry—an unavoidable part of most dental treatments—creates a high-risk situation. The US Centers for Disease Control and The Occupational Safety and Health Administration consider dental procedures to be of “highest risk” in the potential spreading of SARS-CoV-2 and other respiratory viruses. There are several ways to reduce or eliminate the virus: (i) cease or postpone dentistry (public and personal health risk), (ii) screen patients immediately prior to dental treatment (by appropriate testing, if any), (iii) block/remove the virus containing aerosol by engineering controls together with stringent personal protective equipment use. The present work takes a novel, fourth approach. By altering the physical response of water to the rotary or ultrasonic forces that are used in dentistry, the generation of aerosol particles and the distance any aerosol may spread beyond the point of generation can be markedly suppressed or completely eliminated in comparison to water for both the ultrasonic scaler and dental handpiece.
- 25 August 2020
- Published by AIP Publishing
- Vol. 32 (8) , 083111
10.1063/5.0021476.6
The aerosol transmissibility of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) has impacted the delivery of health care and essentially stopped the provision of medical and dental therapies. Dentistry uses rotary, ultrasonic, and laser-based instruments that produce water-based aerosols in the daily, routine treatment of patients. Abundant aerosols are generated, which reach health care workers and other patients. Viruses, including SARS-CoV-2 virus and related coronavirus disease (COVID-19) pandemic, continued expansion throughout the USA and the world. The virus is spread by both droplet (visible drops) and aerosol (practically invisible drops) transmission. The generation of aerosols in dentistry—an unavoidable part of most dental treatments—creates a high-risk situation. The US Centers for Disease Control and The Occupational Safety and Health Administration consider dental procedures to be of “highest risk” in the potential spreading of SARS-CoV-2 and other respiratory viruses. There are several ways to reduce or eliminate the virus: (i) cease or postpone dentistry (public and personal health risk), (ii) screen patients immediately prior to dental treatment (by appropriate testing, if any), (iii) block/remove the virus containing aerosol by engineering controls together with stringent personal protective equipment use. The present work takes a novel, fourth approach. By altering the physical response of water to the rotary or ultrasonic forces that are used in dentistry, the generation of aerosol particles and the distance any aerosol may spread beyond the point of generation can be markedly suppressed or completely eliminated in comparison to water for both the ultrasonic scaler and dental handpiece.
- 25 August 2020
- Published by AIP Publishing
- Vol. 32 (8) , 083111
10.1063/5.0021476.1
The aerosol transmissibility of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) has impacted the delivery of health care and essentially stopped the provision of medical and dental therapies. Dentistry uses rotary, ultrasonic, and laser-based instruments that produce water-based aerosols in the daily, routine treatment of patients. Abundant aerosols are generated, which reach health care workers and other patients. Viruses, including SARS-CoV-2 virus and related coronavirus disease (COVID-19) pandemic, continued expansion throughout the USA and the world. The virus is spread by both droplet (visible drops) and aerosol (practically invisible drops) transmission. The generation of aerosols in dentistry—an unavoidable part of most dental treatments—creates a high-risk situation. The US Centers for Disease Control and The Occupational Safety and Health Administration consider dental procedures to be of “highest risk” in the potential spreading of SARS-CoV-2 and other respiratory viruses. There are several ways to reduce or eliminate the virus: (i) cease or postpone dentistry (public and personal health risk), (ii) screen patients immediately prior to dental treatment (by appropriate testing, if any), (iii) block/remove the virus containing aerosol by engineering controls together with stringent personal protective equipment use. The present work takes a novel, fourth approach. By altering the physical response of water to the rotary or ultrasonic forces that are used in dentistry, the generation of aerosol particles and the distance any aerosol may spread beyond the point of generation can be markedly suppressed or completely eliminated in comparison to water for both the ultrasonic scaler and dental handpiece.
- 25 August 2020
- Published by AIP Publishing
- Vol. 32 (8) , 083111
10.1063/5.0021476.1
The aerosol transmissibility of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) has impacted the delivery of health care and essentially stopped the provision of medical and dental therapies. Dentistry uses rotary, ultrasonic, and laser-based instruments that produce water-based aerosols in the daily, routine treatment of patients. Abundant aerosols are generated, which reach health care workers and other patients. Viruses, including SARS-CoV-2 virus and related coronavirus disease (COVID-19) pandemic, continued expansion throughout the USA and the world. The virus is spread by both droplet (visible drops) and aerosol (practically invisible drops) transmission. The generation of aerosols in dentistry—an unavoidable part of most dental treatments—creates a high-risk situation. The US Centers for Disease Control and The Occupational Safety and Health Administration consider dental procedures to be of “highest risk” in the potential spreading of SARS-CoV-2 and other respiratory viruses. There are several ways to reduce or eliminate the virus: (i) cease or postpone dentistry (public and personal health risk), (ii) screen patients immediately prior to dental treatment (by appropriate testing, if any), (iii) block/remove the virus containing aerosol by engineering controls together with stringent personal protective equipment use. The present work takes a novel, fourth approach. By altering the physical response of water to the rotary or ultrasonic forces that are used in dentistry, the generation of aerosol particles and the distance any aerosol may spread beyond the point of generation can be markedly suppressed or completely eliminated in comparison to water for both the ultrasonic scaler and dental handpiece.
- 25 August 2020
- Published by AIP Publishing
- Vol. 32 (8) , 083111
10.1063/5.0021476.5
The aerosol transmissibility of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) has impacted the delivery of health care and essentially stopped the provision of medical and dental therapies. Dentistry uses rotary, ultrasonic, and laser-based instruments that produce water-based aerosols in the daily, routine treatment of patients. Abundant aerosols are generated, which reach health care workers and other patients. Viruses, including SARS-CoV-2 virus and related coronavirus disease (COVID-19) pandemic, continued expansion throughout the USA and the world. The virus is spread by both droplet (visible drops) and aerosol (practically invisible drops) transmission. The generation of aerosols in dentistry—an unavoidable part of most dental treatments—creates a high-risk situation. The US Centers for Disease Control and The Occupational Safety and Health Administration consider dental procedures to be of “highest risk” in the potential spreading of SARS-CoV-2 and other respiratory viruses. There are several ways to reduce or eliminate the virus: (i) cease or postpone dentistry (public and personal health risk), (ii) screen patients immediately prior to dental treatment (by appropriate testing, if any), (iii) block/remove the virus containing aerosol by engineering controls together with stringent personal protective equipment use. The present work takes a novel, fourth approach. By altering the physical response of water to the rotary or ultrasonic forces that are used in dentistry, the generation of aerosol particles and the distance any aerosol may spread beyond the point of generation can be markedly suppressed or completely eliminated in comparison to water for both the ultrasonic scaler and dental handpiece.
- 25 August 2020
- Published by AIP Publishing
- Vol. 32 (8) , 083111
10.1063/5.0021476.5
The aerosol transmissibility of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) has impacted the delivery of health care and essentially stopped the provision of medical and dental therapies. Dentistry uses rotary, ultrasonic, and laser-based instruments that produce water-based aerosols in the daily, routine treatment of patients. Abundant aerosols are generated, which reach health care workers and other patients. Viruses, including SARS-CoV-2 virus and related coronavirus disease (COVID-19) pandemic, continued expansion throughout the USA and the world. The virus is spread by both droplet (visible drops) and aerosol (practically invisible drops) transmission. The generation of aerosols in dentistry—an unavoidable part of most dental treatments—creates a high-risk situation. The US Centers for Disease Control and The Occupational Safety and Health Administration consider dental procedures to be of “highest risk” in the potential spreading of SARS-CoV-2 and other respiratory viruses. There are several ways to reduce or eliminate the virus: (i) cease or postpone dentistry (public and personal health risk), (ii) screen patients immediately prior to dental treatment (by appropriate testing, if any), (iii) block/remove the virus containing aerosol by engineering controls together with stringent personal protective equipment use. The present work takes a novel, fourth approach. By altering the physical response of water to the rotary or ultrasonic forces that are used in dentistry, the generation of aerosol particles and the distance any aerosol may spread beyond the point of generation can be markedly suppressed or completely eliminated in comparison to water for both the ultrasonic scaler and dental handpiece.