MFMark D. Fletcher

Mark D. Fletcher

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Mark D. Fletcher has a total of 33 co-authors. Here are the top co-authors by number of shared publications:

  • Carl A. Verschuur

    Faculty of Medicine, University of Southampton, Southampton, UK

    6 shared publications
  • Samuel W. Perry

    University of Southampton Auditory Implant Service, University of Southampton, Southampton, UK

    6 shared publications
  • Sian Lloyd Jones

    Department of Audiology and Hearing Therapy, Royal South Hants Hospital, Brinton's Terrace, Southampton SO14 0YG, United Kingdom

    5 shared publications
  • Benjamin Lineton

    Faculty of Engineering and Physical Sciences, University of Southampton, University Road, Southampton, SO17 1BJ, United Kingdom

    4 shared publications
  • Jessica de Boer

    Medical Research Council Institute of Hearing Research, The University of Nottingham, Nottingham, UK

    4 shared publications
  • Katrin Krumbholz

    School of Medicine, University of Nottingham

    4 shared publications

Latest Publications

  • Open Access

    Spectral peak picking improves tactile speech perception

    by Mark D. Fletcher, Carl A. Verschuur, Esma Akis

    Individual differences in speech perception often arise from disparities in access to acoustic–phonetic cues, particularly among those with hearing loss. Haptic hearing aids, which convey speech information through the sense of touch, offer a complementary pathway to improve speech understanding. However, effectively transmitting critical speech features through vibrotactile stimulation remains challenging. To address this challenge, we introduce a tactile spectral peak picking (tSPP) approach, integrated into a vocoder-based audio-to-tactile conversion algorithm to enhance vibrotactile phoneme discrimination. The tactile vocoder decomposes audio into eight frequency bands, with tSPP selectively transmitting only the most energetic bands to emphasise dominant spectral features. Tactile phoneme discrimination on the wrist was tested in 26 participants using either the tactile vocoder alone or with the tSPP algorithm selecting one, two, or four peaks. Discrimination improved significantly when one, two, or four peaks were selected relative to the vocoder alone, with the greatest benefits observed for one- and two-peak tSPP (average improvement: 7.5%). These findings demonstrate that selective enhancement of spectrally salient features can improve tactile speech perception. The algorithm is suitable for real-time use in wearable sensory substitution devices and could aid the development of effective haptic hearing aids.


  • Open Access

    Improved Speech Recognition in Adults With Conductive or Mixed Hearing Loss Using a Direct-to-Consumer Bone-Conduction Device: A Multiple Methods Intervention Study

    by Thomas Hampton, Mark Fletcher, Alan Sanderson, Manuel Loureiro, Kevin Mortimer, Mahmood F Bhutta

    Background: Hearing loss affects 20% of the global population, including 250 million experiencing chronic suppurative otitis media, which can present challenges for conventional hearing aids due to ear discharge. Although assistive technology for hearing is available in high-income settings, provision is poor in low-income settings due to high costs and low availability of audiology services, reaching approximately 3% of those who could benefit from it. Objective: This study aimed to evaluate the performance of a low-cost self-fitted direct-to-consumer bone-conduction headset for individuals with conductive or mixed hearing loss. Methods: We conducted a multiple methods study to test the efficacy and acceptability of this device using a purposive sample. Participants with a range of conductive and mixed hearing loss underwent speech-in-quiet speech audiometry with and without the device and took part in feedback interviews exploring their subjective impressions of the device. Results: In 33 participants, the device improved speech recognition in those with bone conduction thresholds <50 dB by a median of 11%, with larger air-bone gap associated with larger improvement. Participants rated the device positively on weight, style, and ease of use. Conclusions: This multiple methods study assessed the acceptability and efficacy of a low cost self-fitted bone-conduction device in adults. We found the device provides hearing benefit for those with conductive or mixed hearing loss (with bone conduction thresholds <50dB HL). Those with significant conductive hearing loss were measured to have their speech perception significantly improved. Participants had a mixed response to device aesthetics. Further studies should seek to establish if this type of device has effectiveness in real-world trials and which individuals are most likely to benefit. This low cost device could provide hearing benefits to millions of people without access to other devices. Product designers and clinical researchers should explore device optimization. Given the economic impacts of hearing loss across the globe, this style of self-fitted device could represent a paradigm shift in future assistive technology for hearing loss, in both high and low resource settings.


  • Open Access

    Improved tactile speech perception and noise robustness using audio-to-tactile sensory substitution with amplitude envelope expansion

    by Mark D. Fletcher, Esma Akis, Carl A. Verschuur, Samuel W. Perry

    Recent advances in haptic technology could allow haptic hearing aids, which convert audio to tactile stimulation, to become viable for supporting people with hearing loss. A tactile vocoder strategy for audio-to-tactile conversion, which exploits these advances, has recently shown significant promise. In this strategy, the amplitude envelope is extracted from several audio frequency bands and used to modulate the amplitude of a set of vibro-tactile tones. The vocoder strategy allows good consonant discrimination, but vowel discrimination is poor and the strategy is susceptible to background noise. In the current study, we assessed whether multi-band amplitude envelope expansion can effectively enhance critical vowel features, such as formants, and improve speech extraction from noise. In 32 participants with normal touch perception, tactile-only phoneme discrimination with and without envelope expansion was assessed both in quiet and in background noise. Envelope expansion improved performance in quiet by 10.3% for vowels and by 5.9% for consonants. In noise, envelope expansion improved overall phoneme discrimination by 9.6%, with no difference in benefit between consonants and vowels. The tactile vocoder with envelope expansion can be deployed in real-time on a compact device and could substantially improve clinical outcomes for a new generation of haptic hearing aids.


  • Open Access

    Improved tactile speech robustness to background noise with a dual-path recurrent neural network noise-reduction method

    by Mark D. Fletcher, Samuel W. Perry, Iordanis Thoidis, Carl A. Verschuur, Tobias Goehring

    Many people with hearing loss struggle to understand speech in noisy environments, making noise robustness critical for hearing-assistive devices. Recently developed haptic hearing aids, which convert audio to vibration, can improve speech-in-noise performance for cochlear implant (CI) users and assist those unable to access hearing-assistive devices. They are typically body-worn rather than head-mounted, allowing additional space for batteries and microprocessors, and so can deploy more sophisticated noise-reduction techniques. The current study assessed whether a real-time-feasible dual-path recurrent neural network (DPRNN) can improve tactile speech-in-noise performance. Audio was converted to vibration on the wrist using a vocoder method, either with or without noise reduction. Performance was tested for speech in a multi-talker noise (recorded at a party) with a 2.5-dB signal-to-noise ratio. An objective assessment showed the DPRNN improved the scale-invariant signal-to-distortion ratio by 8.6 dB and substantially outperformed traditional noise-reduction (log-MMSE). A behavioural assessment in 16 participants showed the DPRNN improved tactile-only sentence identification in noise by 8.2%. This suggests that advanced techniques like the DPRNN could substantially improve outcomes with haptic hearing aids. Low-cost haptic devices could soon be an important supplement to hearing-assistive devices such as CIs or offer an alternative for people who cannot access CI technology.


  • Open Access

    Improved tactile speech perception using audio-to-tactile sensory substitution with formant frequency focusing

    by Mark D. Fletcher, Esma Akis, Carl A. Verschuur, Samuel W. Perry

    Haptic hearing aids, which provide speech information through tactile stimulation, could substantially improve outcomes for both cochlear implant users and for those unable to access cochlear implants. Recent advances in wide-band haptic actuator technology have made new audio-to-tactile conversion strategies viable for wearable devices. One such strategy filters the audio into eight frequency bands, which are evenly distributed across the speech frequency range. The amplitude envelopes from the eight bands modulate the amplitudes of eight low-frequency tones, which are delivered through vibration to a single site on the wrist. This tactile vocoder strategy effectively transfers some phonemic information, but vowels and obstruent consonants are poorly portrayed. In 20 participants with normal touch perception, we tested (1) whether focusing the audio filters of the tactile vocoder more densely around the first and second formant frequencies improved tactile vowel discrimination, and (2) whether focusing filters at mid-to-high frequencies improved obstruent consonant discrimination. The obstruent-focused approach was found to be ineffective. However, the formant-focused approach improved vowel discrimination by 8%, without changing overall consonant discrimination. The formant-focused tactile vocoder strategy, which can readily be implemented in real time on a compact device, could substantially improve speech perception for haptic hearing aid users.


  • Open Access

    Improved tactile speech robustness to background noise with a dual-path recurrent neural network noise-reduction strategy

    by Mark D. Fletcher, Samuel W. Perry, Iordanis Thoidis, Carl A. Verschuur, Tobias Goehring

    Many hearing-impaired people struggle to understand speech in background noise, making noise robustness critical for hearing-assistive devices. Recently developed haptic hearing aids, which convert audio to vibration, can improve speech-in-noise performance for cochlear implant (CI) users and assist those unable to access hearing-assistive devices. Haptic hearing aids are typically worn on the body rather than the head, allowing additional space for batteries and microprocessors. This means they can deploy more sophisticated noise-reduction techniques. In the current study, we assessed whether a real-time-feasible noise-reduction strategy, using a dual-path recurrent neural network (DPRNN), improves the noise robustness of haptic hearing aids. Audio was converted to vibration on the wrist using a previously developed vocoder method, either with or without noise reduction. In 16 participants, tactile-only sentence identification was measured for speech in quiet and in multi-talker background noise. The DPRNN improved sentence identification in noise by 8.2% on average and did not affect performance in quiet. This suggests that advanced techniques like the DPRNN could substantially improve outcomes with haptic hearing aids. Low cost, non-invasive haptic devices could soon be an important supplement to hearing-assistive devices such as CIs or offer an alternative for people who are unable to access CI technology.

  • Open Access

    Improving speech perception for hearing-impaired listeners using audio-to-tactile sensory substitution with multiple frequency channels

    by Mark D. Fletcher, Carl A. Verschuur, Samuel W. Perry

    Cochlear implants (CIs) have revolutionised treatment of hearing loss, but large populations globally cannot access them either because of disorders that prevent implantation or because they are expensive and require specialist surgery. Recent technology developments mean that haptic aids, which transmit speech through vibration, could offer a viable low-cost, non-invasive alternative. One important development is that compact haptic actuators can now deliver intense stimulation across multiple frequencies. We explored whether these multiple frequency channels can transfer spectral information to improve tactile phoneme discrimination. To convert audio to vibration, the speech amplitude envelope was extracted from one or more audio frequency bands and used to amplitude modulate one or more vibro-tactile tones delivered to a single-site on the wrist. In 26 participants with normal touch sensitivity, tactile-only phoneme discrimination was assessed with one, four, or eight frequency bands. Compared to one frequency band, performance improved by 5.9% with four frequency bands and by 8.4% with eight frequency bands. The multi-band signal-processing approach can be implemented in real-time on a compact device, and the vibro-tactile tones can be reproduced by the latest compact, low-powered actuators. This approach could therefore readily be implemented in a low-cost haptic hearing aid to deliver real-world benefits.


  • Open Access

    Listen With Your Wrists

    by Mark D. Fletcher

    Most of us have five senses that our brains use to create a model of the world around us. We see, hear, smell, taste, and touch our way around. If one of your senses is not working properly, your brain fills in the gaps by paying more attention to the other senses. However, your other senses cannot always fill in the gaps. If your ears are not working, your eyes alone may not be able to tell your brain that an out-of-control car is screeching toward you! But what if we could help the brain fill in the gaps by purposefully sending the missing information through another sense? What if you could “hear” where a sound is through your sense of touch? This article will explain how people were able to do just that, using wristbands that converted sound into vibration.


  • Open Access

    Can Haptic Stimulation Enhance Music Perception in Hearing-Impaired Listeners?

    by Mark D. Fletcher

    Cochlear implants (CIs) have been remarkably successful at restoring hearing in severely-to-profoundly hearing-impaired individuals. However, users often struggle to deconstruct complex auditory scenes with multiple simultaneous sounds, which can result in reduced music enjoyment and impaired speech understanding in background noise. Hearing aid users often have similar issues, though these are typically less acute. Several recent studies have shown that haptic stimulation can enhance CI listening by giving access to sound features that are poorly transmitted through the electrical CI signal. This “electro-haptic stimulation” improves melody recognition and pitch discrimination, as well as speech-in-noise performance and sound localization. The success of this approach suggests it could also enhance auditory perception in hearing-aid users and other hearing-impaired listeners. This review focuses on the use of haptic stimulation to enhance music perception in hearing-impaired listeners. Music is prevalent throughout everyday life, being critical to media such as film and video games, and often being central to events such as weddings and funerals. It represents the biggest challenge for signal processing, as it is typically an extremely complex acoustic signal, containing multiple simultaneous harmonic and inharmonic sounds. Signal-processing approaches developed for enhancing music perception could therefore have significant utility for other key issues faced by hearing-impaired listeners, such as understanding speech in noisy environments. This review first discusses the limits of music perception in hearing-impaired listeners and the limits of the tactile system. It then discusses the evidence around integration of audio and haptic stimulation in the brain. Next, the features, suitability, and success of current haptic devices for enhancing music perception are reviewed, as well as the signal-processing approaches that could be deployed in future haptic devices. Finally, the cutting-edge technologies that could be exploited for enhancing music perception with haptics are discussed. These include the latest micro motor and driver technology, low-power wireless technology, machine learning, big data, and cloud computing. New approaches for enhancing music perception in hearing-impaired listeners could substantially improve quality of life. Furthermore, effective haptic techniques for providing complex sound information could offer a non-invasive, affordable means for enhancing listening more broadly in hearing-impaired individuals.


  • Open Access

    Sensitivity to Haptic Sound-Localization Cues at Different Body Locations

    by Mark D. Fletcher, Jana Zgheib, Samuel W. Perry

    Cochlear implants (CIs) recover hearing in severely to profoundly hearing-impaired people by electrically stimulating the cochlea. While they are extremely effective, spatial hearing is typically severely limited. Recent studies have shown that haptic stimulation can supplement the electrical CI signal (electro-haptic stimulation) and substantially improve sound localization. In haptic sound-localization studies, the signal is extracted from the audio received by behind-the-ear devices and delivered to each wrist. Localization is achieved using tactile intensity differences (TIDs) across the wrists, which match sound intensity differences across the ears (a key sound localization cue). The current study established sensitivity to across-limb TIDs at three candidate locations for a wearable haptic device, namely: the lower tricep and the palmar and dorsal wrist. At all locations, TID sensitivity was similar to the sensitivity to across-ear intensity differences for normal-hearing listeners. This suggests that greater haptic sound-localization accuracy than previously shown can be achieved. The dynamic range was also measured and far exceeded that available through electrical CI stimulation for all of the locations, suggesting that haptic stimulation could provide additional sound-intensity information. These results indicate that an effective haptic aid could be deployed for any of the candidate locations, and could offer a low-cost, non-invasive means of improving outcomes for hearing-impaired listeners.