Gael Le Coz
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Gael Le Coz has a total of 37 co-authors. Here are the top co-authors by number of shared publications:
- Abdelhadi Moufki
Université de Lorraine, CNRS, LEM3, Metz, France
4 shared publications - Pascal Laheurte
Université de Lorraine, CNRS, LEM3, Metz, France
4 shared publications - Houssemeddine Ben Boubaker
Universite de Lorraine, CNRS, LEM3, IMT, Saint Die des Vosges, France
3 shared publications P. Laheurte
Université de Lorraine, CNRS, Metz, France
3 shared publications- Mohammed Nouari
Laboratoire d’Energétique et de Mécanique Théorique et Appliquée, Ecole des Mines de Nancy, Université de Lorraine, F-88100 Saint Dié Des Vosges, France
2 shared publications - Paul Didier
Universite de Lorraine, CNRS, LEM3, Arts et Metiers ParisTech, 57070 Metz, France
2 shared publications
Latest Publications
- 10 November 2023
- Published by Springer Nature in The International Journal of Advanced Manufacturing Technology
- Vol. 131 (2) , 817-825
Development of a quick-stop device for micro-cutting
- 10 November 2023
- Published by Springer Nature in The International Journal of Advanced Manufacturing Technology
- Vol. 131 (2) , 817-825
Development of a quick-stop device for micro-cutting
- Open Access
- 28 November 2022
- Published by Springer Nature in Research Square
Experimental and numerical investigations of cutting forces and chip formation during micro-cutting of Ti42Nb titanium alloy produced by laser-based powder bed fusion
Ti-Nb alloys are high-profile candidates for the biomedical applications. However, because of poor surface integrity (i.e. residual stress and surface roughness), Ti-Nb implantable medical devices need to be machined in order to obtain functional surfaces finish. In this work, experimentaland numerical investigations are conducted to study the micro-cutting response of Ti42Nb titanium alloy produced by laser-based powder bed fusion. Experimental micro-cutting tests are carried out using precision turning lathe. Trials are performed with two cutting velocities of 60 m/min and 120 m/min and different feed rates, varying from 5 to 40μm/rev. For the numerical study, a porous crystal plasticity-based model is proposed to address the impact of anisotropy and microstructure heterogeneities of the polycrystalline material. The crystal plasticity-basedmodel is identified using strain–stress curves obtained from compression tests performed under two strain rates and a wide range of temperatures. Numerical micro-cutting simulations are performed in order to gain insight into the impact of microstructural features (i.e. crystallographic orientation and grain size) on the machinability of the alloy.According to the results, the effect of the strain rates and the temperature on the thermomechanical behavior of the Ti42Nb titanium alloy produced by laser-based powder bed fusion is correctly depicted. The model captured the strain localization on adiabatic shear band during compression tests. According to the micro-cutting simulations, the local variables such as temperature, damage and plastic deformation are strongly impacted by the crystallographic orientations and the grain size.In addition, depending on the crystallographic orientations, the chip morphology changes form continues, slightly segmented to largely segmented.
- 28 November 2022
- Published by Springer Nature in Research Square
Open AccessExperimental and numerical investigations of cutting forces and chip formation during micro-cutting of Ti42Nb titanium alloy produced by laser-based powder bed fusion
Ti-Nb alloys are high-profile candidates for the biomedical applications. However, because of poor surface integrity (i.e. residual stress and surface roughness), Ti-Nb implantable medical devices need to be machined in order to obtain functional surfaces finish. In this work, experimentaland numerical investigations are conducted to study the micro-cutting response of Ti42Nb titanium alloy produced by laser-based powder bed fusion. Experimental micro-cutting tests are carried out using precision turning lathe. Trials are performed with two cutting velocities of 60 m/min and 120 m/min and different feed rates, varying from 5 to 40μm/rev. For the numerical study, a porous crystal plasticity-based model is proposed to address the impact of anisotropy and microstructure heterogeneities of the polycrystalline material. The crystal plasticity-basedmodel is identified using strain–stress curves obtained from compression tests performed under two strain rates and a wide range of temperatures. Numerical micro-cutting simulations are performed in order to gain insight into the impact of microstructural features (i.e. crystallographic orientation and grain size) on the machinability of the alloy.According to the results, the effect of the strain rates and the temperature on the thermomechanical behavior of the Ti42Nb titanium alloy produced by laser-based powder bed fusion is correctly depicted. The model captured the strain localization on adiabatic shear band during compression tests. According to the micro-cutting simulations, the local variables such as temperature, damage and plastic deformation are strongly impacted by the crystallographic orientations and the grain size.In addition, depending on the crystallographic orientations, the chip morphology changes form continues, slightly segmented to largely segmented.
- Open Access
- 16 September 2022
- Published by EDP Sciences in Matériaux & Techniques
- Vol. 110 (3) , 304
Post-processing of additive manufactured parts: a numerical strategy applied in maxillary implantology
To obtain a functional part from additive manufacturing (AM) technologies, some surfaces require post-processing by machining. An approach is developed using additive manufacturing supports as a clamping device for the milling operation. A model combining an analytical approach to determine the cutting forces with a finite element model (FEM) to predict the dynamical response of the workpiece-supports system is proposed. The complex structure of the supports is homogenized with a simplified geometry with equivalent stiffness and mechanical properties. A case study from the biomedical field is proposed: the finishing operation of a custom-made maxillary reconstruction plate is simulated. A parametric study is proposed with: (1) two different lattice geometries used as support structures; (2) up and down milling; (3) different depths of cut.
- 16 September 2022
- Published by EDP Sciences in Matériaux & Techniques
- Vol. 110 (3) , 304
Open AccessPost-processing of additive manufactured parts: a numerical strategy applied in maxillary implantology
To obtain a functional part from additive manufacturing (AM) technologies, some surfaces require post-processing by machining. An approach is developed using additive manufacturing supports as a clamping device for the milling operation. A model combining an analytical approach to determine the cutting forces with a finite element model (FEM) to predict the dynamical response of the workpiece-supports system is proposed. The complex structure of the supports is homogenized with a simplified geometry with equivalent stiffness and mechanical properties. A case study from the biomedical field is proposed: the finishing operation of a custom-made maxillary reconstruction plate is simulated. A parametric study is proposed with: (1) two different lattice geometries used as support structures; (2) up and down milling; (3) different depths of cut.
- Open Access
Impact of the Loading Conditions and the Building Directions on the Mechanical Behavior of Biomedical β-Titanium Alloy Produced In Situ by Laser-Based Powder Bed Fusion
In order to simulate micromachining of Ti-Nb medical devices produced in situ by selective laser melting, it is necessary to use constitutive models that allow one to reproduce accurately the material behavior under extreme loading conditions. The identification of these models is often performed using experimental tension or compression data. In this work, compression tests are conducted to investigate the impact of the loading conditions and the laser-based powder bed fusion (LB-PBF) building directions on the mechanical behavior of -Ti42Nb alloy. Compression tests are performed under two strain rates (1 s and 10 s) and four temperatures (298 K, 673 K, 873 K and 1073 K). Two LB-PBF building directions are used for manufacturing the compression specimens. Therefore, different metallographic analyses (i.e., optical microscopy (OM), scanning electron microscopy (SEM), energy-dispersive X-ray (EDX), electron backscatter diffraction (EBSD) and X-ray diffraction) have been carried out on the deformed specimens to gain insight into the impact of the loading conditions on microstucture alterations. According to the results, whatever the loading conditions are, specimens manufactured with a building direction of 45 exhibit higher flow stress than those produced with a building direction of 90, highlighting the anisotropy of the as-LB-PBFed alloy. Additionally, the deformed alloy exhibits at room temperature a yielding strength of 1180 ± 40 MPa and a micro-hardness of 310 ± 7 HV. Experimental observations demonstrated two strain localization modes: a highly deformed region corresponding to the localization of the plastic deformation in the central region of specimens and perpendicular to the compression direction and an adiabatic shear band oriented with an angle of ±45 with respect to same direction.Open AccessImpact of the Loading Conditions and the Building Directions on the Mechanical Behavior of Biomedical β-Titanium Alloy Produced In Situ by Laser-Based Powder Bed Fusion
In order to simulate micromachining of Ti-Nb medical devices produced in situ by selective laser melting, it is necessary to use constitutive models that allow one to reproduce accurately the material behavior under extreme loading conditions. The identification of these models is often performed using experimental tension or compression data. In this work, compression tests are conducted to investigate the impact of the loading conditions and the laser-based powder bed fusion (LB-PBF) building directions on the mechanical behavior of -Ti42Nb alloy. Compression tests are performed under two strain rates (1 s and 10 s) and four temperatures (298 K, 673 K, 873 K and 1073 K). Two LB-PBF building directions are used for manufacturing the compression specimens. Therefore, different metallographic analyses (i.e., optical microscopy (OM), scanning electron microscopy (SEM), energy-dispersive X-ray (EDX), electron backscatter diffraction (EBSD) and X-ray diffraction) have been carried out on the deformed specimens to gain insight into the impact of the loading conditions on microstucture alterations. According to the results, whatever the loading conditions are, specimens manufactured with a building direction of 45 exhibit higher flow stress than those produced with a building direction of 90, highlighting the anisotropy of the as-LB-PBFed alloy. Additionally, the deformed alloy exhibits at room temperature a yielding strength of 1180 ± 40 MPa and a micro-hardness of 310 ± 7 HV. Experimental observations demonstrated two strain localization modes: a highly deformed region corresponding to the localization of the plastic deformation in the central region of specimens and perpendicular to the compression direction and an adiabatic shear band oriented with an angle of ±45 with respect to same direction. - Open Access
- 28 August 2020
- Published by MDPI AG in Applied Sciences
- Vol. 10 (17) , 5973
Finite Element Analysis of the Stress Field in Peri-Implant Bone: A Parametric Study of Influencing Parameters and Their Interactions for Multi-Objective Optimization
The present work proposes a parametric finite element model of the general case of a single loaded dental implant. The objective is to estimate and quantify the main effects of several parameters on stress distribution and load transfer between a loaded dental implant and its surrounding bone. The interactions between them are particularly investigated. Seven parameters (implant design and material) were considered as input variables to build the parametric finite element model: the implant diameter, length, taper and angle of inclination, Young’s modulus, the thickness of the cortical bone and Young’s modulus of the cancellous bone. All parameter combinations were tested with a full factorial design for a total of 512 models. Two biomechanical responses were identified to highlight the main effects of the full factorial design and first-order interaction between parameters: peri-implant bone stress and load transfer between bones and implants. The description of the two responses using the identified coefficients then makes it possible to optimize the implant configuration in a case study with type IV. The influence of the seven considered parameters was quantified, and objective information was given to support surgeon choices for implant design and placement. The implant diameter and Young’s modulus and the cortical thickness were the most influential parameters on the two responses. The importance of a low Young’s modulus alloy was highlighted to reduce the stress shielding between implants and the surrounding bone. This method allows obtaining optimized configurations for several case studies with a custom-made design implant.
- 28 August 2020
- Published by MDPI AG in Applied Sciences
- Vol. 10 (17) , 5973
Open AccessFinite Element Analysis of the Stress Field in Peri-Implant Bone: A Parametric Study of Influencing Parameters and Their Interactions for Multi-Objective Optimization
The present work proposes a parametric finite element model of the general case of a single loaded dental implant. The objective is to estimate and quantify the main effects of several parameters on stress distribution and load transfer between a loaded dental implant and its surrounding bone. The interactions between them are particularly investigated. Seven parameters (implant design and material) were considered as input variables to build the parametric finite element model: the implant diameter, length, taper and angle of inclination, Young’s modulus, the thickness of the cortical bone and Young’s modulus of the cancellous bone. All parameter combinations were tested with a full factorial design for a total of 512 models. Two biomechanical responses were identified to highlight the main effects of the full factorial design and first-order interaction between parameters: peri-implant bone stress and load transfer between bones and implants. The description of the two responses using the identified coefficients then makes it possible to optimize the implant configuration in a case study with type IV. The influence of the seven considered parameters was quantified, and objective information was given to support surgeon choices for implant design and placement. The implant diameter and Young’s modulus and the cortical thickness were the most influential parameters on the two responses. The importance of a low Young’s modulus alloy was highlighted to reduce the stress shielding between implants and the surrounding bone. This method allows obtaining optimized configurations for several case studies with a custom-made design implant.
- 25 August 2020
- Published by Springer Nature in The International Journal of Advanced Manufacturing Technology
- Vol. 110 (5-6) , 1615-1625
Precision turning analysis of Ti-6Al-4V skin produced by selective laser melting using a design of experiment approach
- 25 August 2020
- Published by Springer Nature in The International Journal of Advanced Manufacturing Technology
- Vol. 110 (5-6) , 1615-1625
Precision turning analysis of Ti-6Al-4V skin produced by selective laser melting using a design of experiment approach
- 18 July 2020
- Published by IOP Publishing in Medical Engineering & Physics
- Vol. 84 (1) , 151-160
An analytical modeling with experimental validation of bone temperature rise in drilling process
Predicting the bone thermal response in a surgical operation remains a major challenge. In the previous works, metal machining theory has frequently been used to predict bone temperature in drilling process. However, several experimental studies demonstrate that the chip formation process is very complex compared to metal cutting. In the present study, a simplified analytical model based on the moving heat source approach combined with the method of image sources is developed. The heat source due to the drill-bit tip was supposed to be proportional to the cutting energy. The friction at the tool-hole contact was also considered. An experimental study was performed on fresh femur pig bone for cutting speeds from 2 to 20 m/min. Temperature rise, drilling forces and bone volume fraction were measured. The experimental validation showed that the model reproduces satisfactorily the increase in temperature up to the maximum value while it overestimates the temperature during the cooling stage. A parametric study (thermal boundary conditions, lateral friction) was also performed. From the predicted results, it appears that the model can be improved by considering the effects of the bone volume fraction which can present a significant variation in the bone sample.
- 18 July 2020
- Published by IOP Publishing in Medical Engineering & Physics
- Vol. 84 (1) , 151-160
An analytical modeling with experimental validation of bone temperature rise in drilling process
Predicting the bone thermal response in a surgical operation remains a major challenge. In the previous works, metal machining theory has frequently been used to predict bone temperature in drilling process. However, several experimental studies demonstrate that the chip formation process is very complex compared to metal cutting. In the present study, a simplified analytical model based on the moving heat source approach combined with the method of image sources is developed. The heat source due to the drill-bit tip was supposed to be proportional to the cutting energy. The friction at the tool-hole contact was also considered. An experimental study was performed on fresh femur pig bone for cutting speeds from 2 to 20 m/min. Temperature rise, drilling forces and bone volume fraction were measured. The experimental validation showed that the model reproduces satisfactorily the increase in temperature up to the maximum value while it overestimates the temperature during the cooling stage. A parametric study (thermal boundary conditions, lateral friction) was also performed. From the predicted results, it appears that the model can be improved by considering the effects of the bone volume fraction which can present a significant variation in the bone sample.