Edgar Alberto Unigarro Calpa
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Edgar Alberto Unigarro Calpa has a total of 26 co-authors. Here are the top co-authors by number of shared publications:
- Fredy Segura-Quijano
Electrical and Electronics Engineering Department, Universidad de los Andes, Bogota, Colombia
8 shared publications - Fernando Ramirez
Department of Civil and Environmental Engineering, Universidad de los Andes
4 shared publications - Diego Alejandro Sanz Becerra
ETH Zurich — Institute for Particle Physics and Astrophysics (IPA)
3 shared publications - Jordi Sacristán
IMB-CNM (CSIC), Barcelona, Spain
3 shared publications A. Achury
Department of Civil and Environmental Engineering Universidad de los Andes, Bogotá Colombia
1 shared publicationA. Arciniegas
Instituto Barraquer de América, Bogota D.C., Colombia
1 shared publication
Latest Publications
- 2 September 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 21 (20) , 23608-23613
NFC-Enabled Passive Sensor for the Quality Control of Ethanol Against SARS-CoV-2
Ethanol sanitizers are crucial to fight SARS-CoV-2. Nevertheless, some products concentration and purity are not always adequate and sometimes can be toxic. Conveniently, only the desired substance should be detected, minimizing the risk of false-positive readings from ethanol mixtures or impurities like methanol. Here, we developed a passive wireless dual-sensor based on the permittivity changes of a solution. Our sensor has two capacitive interdigital transductors (IDTs) with different coupling factors (K), each coupled directly to a pair of antennas of a wireless NFC system, and explicitly tuned to assess the quality of a specific sample. The operating principle is based on the coupling frequency of the antennas and the permittivity changes of the solution that turns on or turns off the NFC chip for each antenna. The relation between the two states of the antennas allows quality control and product identification. This NFC-Enabled passive sensor is a cheap alternative to identify possible permittivity changes of a solution. Our NFC-Enabled passive sensor detects a variation of 5 % v/v methanol, deionized water (DI water), and sub-optimal ethanol concentration in an antiseptic solution. Further works can be focused on identifying the frequencies of several substances, and avoiding toxic methanol mixtures and counterfeit ethanol. The quality of a liquid substance can be tested based on its chemical properties by designing sensors that can respond accurately to certain types of samples.
- 2 September 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 21 (20) , 23608-23613
NFC-Enabled Passive Sensor for the Quality Control of Ethanol Against SARS-CoV-2
Ethanol sanitizers are crucial to fight SARS-CoV-2. Nevertheless, some products concentration and purity are not always adequate and sometimes can be toxic. Conveniently, only the desired substance should be detected, minimizing the risk of false-positive readings from ethanol mixtures or impurities like methanol. Here, we developed a passive wireless dual-sensor based on the permittivity changes of a solution. Our sensor has two capacitive interdigital transductors (IDTs) with different coupling factors (K), each coupled directly to a pair of antennas of a wireless NFC system, and explicitly tuned to assess the quality of a specific sample. The operating principle is based on the coupling frequency of the antennas and the permittivity changes of the solution that turns on or turns off the NFC chip for each antenna. The relation between the two states of the antennas allows quality control and product identification. This NFC-Enabled passive sensor is a cheap alternative to identify possible permittivity changes of a solution. Our NFC-Enabled passive sensor detects a variation of 5 % v/v methanol, deionized water (DI water), and sub-optimal ethanol concentration in an antiseptic solution. Further works can be focused on identifying the frequencies of several substances, and avoiding toxic methanol mixtures and counterfeit ethanol. The quality of a liquid substance can be tested based on its chemical properties by designing sensors that can respond accurately to certain types of samples.
- Open Access
- 1 October 2020
- Published by AIP Publishing in AIP Advances
- Vol. 10 (10) , 105029
Wireless differential resonance frequency pressure sensor: Circuital model and prototype validation
This article presents a pressure sensor composed of a set of three Archimedean spiral inductors. One of them is below the other two concentric spirals, where the upper coils are over a flexible membrane. When external pressure is applied over the sensor, the membrane deforms and changes the distance between the lower spirals and the upper inside coil, the capacitance, and its resonance frequency. However, once the sensor is in contact with a conductive medium, a change in the effective permittivity surrounding the sensor takes place reshaping the resonant frequencies. To improve the sensor response, we introduce a reader resonator sensor system. We present the comparative response of the system as a prototype, an analytical model, and a finite element model (FEM). The prototype system is fabricated using a photolithographic process for the elements of the sensor over a polymethylsiloxane and glass substrate, while the reader is fabricated over a FR4 substrate. COMSOL Multiphysics is used for the FEM simulation of the system to evaluate its behavior. The analytical model involves the integration of techniques to obtain the effective permittivity for each element plane and a coupled magnetic resonance to represent the interaction of the parts. We obtain a correspondence between the resonances of the different elements, with a maximum displacement frequency of 240 MHz for the proposed model, and 80 MHz in the FEM case related to the implemented prototype. The accuracy of this model allows a fast analysis to improve the design of this type of topology without high computational processing.
- 1 October 2020
- Published by AIP Publishing in AIP Advances
- Vol. 10 (10) , 105029
Open AccessWireless differential resonance frequency pressure sensor: Circuital model and prototype validation
This article presents a pressure sensor composed of a set of three Archimedean spiral inductors. One of them is below the other two concentric spirals, where the upper coils are over a flexible membrane. When external pressure is applied over the sensor, the membrane deforms and changes the distance between the lower spirals and the upper inside coil, the capacitance, and its resonance frequency. However, once the sensor is in contact with a conductive medium, a change in the effective permittivity surrounding the sensor takes place reshaping the resonant frequencies. To improve the sensor response, we introduce a reader resonator sensor system. We present the comparative response of the system as a prototype, an analytical model, and a finite element model (FEM). The prototype system is fabricated using a photolithographic process for the elements of the sensor over a polymethylsiloxane and glass substrate, while the reader is fabricated over a FR4 substrate. COMSOL Multiphysics is used for the FEM simulation of the system to evaluate its behavior. The analytical model involves the integration of techniques to obtain the effective permittivity for each element plane and a coupled magnetic resonance to represent the interaction of the parts. We obtain a correspondence between the resonances of the different elements, with a maximum displacement frequency of 240 MHz for the proposed model, and 80 MHz in the FEM case related to the implemented prototype. The accuracy of this model allows a fast analysis to improve the design of this type of topology without high computational processing.
- 24 August 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Microwave and Wireless Components Letters
- Vol. 30 (10) , 989-992
On-Chip Inductor in 0.18-μm CMOS for Low-Cost Fully Integrated Contactless Powered Sensors
Contactless sensors with CMOS on-chip antennas use only the top thick metal for the polarization antenna due to the low inductance contribution of the bottom (thin) CMOS metals adding only resistance to the antenna. In this letter, a twolayer inductor (thick top metal layer inductor in series with the bottom thin four-layer metal inductor) configuration was proposed for wireless polarization (by electromagnetic induction). The design proposed was simulated and fabricated in a 0.18-μm CMOS process. The on-chip inductor powers a chip with a 1-mW load at a distance of 2 mm coupled with an external wireless power transmitter at 13.5 MHz with a 30-dBm output. The two-layer inductor configuration reduces the area required for the on-chip inductor by 38% and increases the on-chip inductor quality factor by 25% compared with a single-layer configuration, thus reducing the cost of fabricating fully integrated contactless sensors using only CMOS technologies.
- 24 August 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Microwave and Wireless Components Letters
- Vol. 30 (10) , 989-992
On-Chip Inductor in 0.18-μm CMOS for Low-Cost Fully Integrated Contactless Powered Sensors
Contactless sensors with CMOS on-chip antennas use only the top thick metal for the polarization antenna due to the low inductance contribution of the bottom (thin) CMOS metals adding only resistance to the antenna. In this letter, a twolayer inductor (thick top metal layer inductor in series with the bottom thin four-layer metal inductor) configuration was proposed for wireless polarization (by electromagnetic induction). The design proposed was simulated and fabricated in a 0.18-μm CMOS process. The on-chip inductor powers a chip with a 1-mW load at a distance of 2 mm coupled with an external wireless power transmitter at 13.5 MHz with a 30-dBm output. The two-layer inductor configuration reduces the area required for the on-chip inductor by 38% and increases the on-chip inductor quality factor by 25% compared with a single-layer configuration, thus reducing the cost of fabricating fully integrated contactless sensors using only CMOS technologies.
- 1 October 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-5
Towards a low-cost gas stove control for domestic cooking
- 1 October 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-5
Towards a low-cost gas stove control for domestic cooking
- Open Access
- 11 May 2017
- Published by Institution of Engineering and Technology (IET) in Electronics Letters
- Vol. 53 (11) , 737-739
Differential capacitive pressure sensor design based on standard CMOS
A microelectromechanical system capacitive pressure sensor with a differential configuration (patent pending), including a reference and sensitive capacitor, is presented. A single cavity includes both reference and sensitive electrodes. This implementation is achieved by a size reduction of the sensitive electrode. A reduction of the 40% on the sensible electrode area represents a decrease in the sensor sensitivity of only 12.5%, and allows the reference capacitor implementation in the area commonly used only for the sensitive capacitor. A tridimensional model of the sensor was simulated using a finite‐element solver considering coupled mechanical and electrostatic models. The simulations show that this pressure sensor has a sensitivity of 4.2 fF/bar. The proposed pressure sensor designs use only materials available in complementary metal oxide silicon (CMOS) standard processes. A CMOS compatible post‐process, based on the sacrificial material technique and its restrictions is presented.
- 11 May 2017
- Published by Institution of Engineering and Technology (IET) in Electronics Letters
- Vol. 53 (11) , 737-739
Open AccessDifferential capacitive pressure sensor design based on standard CMOS
A microelectromechanical system capacitive pressure sensor with a differential configuration (patent pending), including a reference and sensitive capacitor, is presented. A single cavity includes both reference and sensitive electrodes. This implementation is achieved by a size reduction of the sensitive electrode. A reduction of the 40% on the sensible electrode area represents a decrease in the sensor sensitivity of only 12.5%, and allows the reference capacitor implementation in the area commonly used only for the sensitive capacitor. A tridimensional model of the sensor was simulated using a finite‐element solver considering coupled mechanical and electrostatic models. The simulations show that this pressure sensor has a sensitivity of 4.2 fF/bar. The proposed pressure sensor designs use only materials available in complementary metal oxide silicon (CMOS) standard processes. A CMOS compatible post‐process, based on the sacrificial material technique and its restrictions is presented.
- 1 October 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-3
Design and implementation of a planar capacitive pressure sensor
In this paper we present the implementation of a capacitive pressure sensor using interdigitated electrodes and a polymer cavity, the sensor functionality is based on the compression of a sealed cavity which changes the dielectric properties on top of two planar interdigitated electrodes (IDE). COMSOL was used to perform multiphysics simulations of the mechanical and electrical behavior of the sensor. The fabrication process of the sensor was made in tree steps: the interdigitated electrodes were fabricated using copper on a FR4 substrate, a sealed cavity of polydimethylsiloxane (PDMS) was built using FR4 molds, and finally the cavity and IDE were assembled with a thin layer of PDMS. The IDE electrodes are composed of 21 fingers and had a squared area of 11×11 mm, the PDMS cavity had an area of 11×11 mm with a height of 900 μm. A precision LCR meter (Agilent 4248A) was used to measure the capacitance variations caused by the pressure changes, the sensor was tested in the range of 0 to 40 psi and has a sensitivity of 3.35 fF/psi. Simulations were used to study the possibility of using functionalized polymers to increase the sensor sensitivity; the aim of this work is to present the design and fabrication process for a planar capacitive sensor, this design requires less fabrication steps than common micro-electromechanicals systems (MEMS) pressure sensors reducing the production costs of the pressure sensors, also allowing new types of integrations.
- 1 October 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-3
Design and implementation of a planar capacitive pressure sensor
In this paper we present the implementation of a capacitive pressure sensor using interdigitated electrodes and a polymer cavity, the sensor functionality is based on the compression of a sealed cavity which changes the dielectric properties on top of two planar interdigitated electrodes (IDE). COMSOL was used to perform multiphysics simulations of the mechanical and electrical behavior of the sensor. The fabrication process of the sensor was made in tree steps: the interdigitated electrodes were fabricated using copper on a FR4 substrate, a sealed cavity of polydimethylsiloxane (PDMS) was built using FR4 molds, and finally the cavity and IDE were assembled with a thin layer of PDMS. The IDE electrodes are composed of 21 fingers and had a squared area of 11×11 mm, the PDMS cavity had an area of 11×11 mm with a height of 900 μm. A precision LCR meter (Agilent 4248A) was used to measure the capacitance variations caused by the pressure changes, the sensor was tested in the range of 0 to 40 psi and has a sensitivity of 3.35 fF/psi. Simulations were used to study the possibility of using functionalized polymers to increase the sensor sensitivity; the aim of this work is to present the design and fabrication process for a planar capacitive sensor, this design requires less fabrication steps than common micro-electromechanicals systems (MEMS) pressure sensors reducing the production costs of the pressure sensors, also allowing new types of integrations.
- 1 October 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-5
Implantable intraocular pressure sensor using principles of electromagnetic radiation
This paper presents a method for intraocular pressure measurement that consists of a passive sensor based in electromagnetic principles. The pressure sensor proposed is implemented by means of a reconfigurable substrate integrated cavity backed-antenna which is based in a backscattering principle for interrogation.
- 1 October 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-5
Implantable intraocular pressure sensor using principles of electromagnetic radiation
This paper presents a method for intraocular pressure measurement that consists of a passive sensor based in electromagnetic principles. The pressure sensor proposed is implemented by means of a reconfigurable substrate integrated cavity backed-antenna which is based in a backscattering principle for interrogation.
- 23 September 2013
- Published by AIP Publishing in Applied Physics Letters
- Vol. 103 (13) , 133502
Passive resonators for wireless passive sensor readout enhancement
A scheme to enhance a wireless passive sensor's readout is presented. This alternative consists of the addition of a passive inductive-capacitive resonator placed between the sensor and readout antenna. A discrete model is proposed and used in simulations to study the effects of the resonator in the sensor-antenna interaction. A resonator was fabricated at 28 MHz to test the enhancement of the sensor's signal. Increases in the sensor's signal and the power transmitted to the sensor were always obtained for frequencies below 28 MHz. All experimental results were consistent with the simulation outcomes.
- 23 September 2013
- Published by AIP Publishing in Applied Physics Letters
- Vol. 103 (13) , 133502
Passive resonators for wireless passive sensor readout enhancement
A scheme to enhance a wireless passive sensor's readout is presented. This alternative consists of the addition of a passive inductive-capacitive resonator placed between the sensor and readout antenna. A discrete model is proposed and used in simulations to study the effects of the resonator in the sensor-antenna interaction. A resonator was fabricated at 28 MHz to test the enhancement of the sensor's signal. Increases in the sensor's signal and the power transmitted to the sensor were always obtained for frequencies below 28 MHz. All experimental results were consistent with the simulation outcomes.
- 1 April 2013
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 23278161,p. 1-3
High resolution implantable wireless MEMS intraocular pressure sensor
The present work shows the design, simulation and fabrication of a high resolution wireless passive Micro-Electro-Mechanical System (MEMS) for intraocular pressure (IOP) measurements. This sensor was designed and simulated using the finite elements analysis software COMSOL. A MEMS parallel-plates capacitor and a planar inductor were used to form an LC resonator. On the sensing process, the intraocular pressure compresses the MEMS capacitor and changes the sensor's resonance frequency. This variation is directly related with the internal pressure of the eye. An external coil (antenna) is used for wireless powering and readout. The fabrication and characterization processes were carried out at the Clean Room Laboratory of the Universidad de los Andes. The Sensor fabrication materials were: fiberglass (FR4), copper and polydimethylsiloxane (PDMS). The sensor was tested from 0 to 40 mmHg showing a 160 kHz/mmHg sensibility. Sensor implantation surgery was successfully performed in a rabbit's eye at Clinica Barraquer in Bogotá. The rabbit has not shown any complications within three months after the surgery.
- 1 April 2013
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 23278161,p. 1-3
High resolution implantable wireless MEMS intraocular pressure sensor
The present work shows the design, simulation and fabrication of a high resolution wireless passive Micro-Electro-Mechanical System (MEMS) for intraocular pressure (IOP) measurements. This sensor was designed and simulated using the finite elements analysis software COMSOL. A MEMS parallel-plates capacitor and a planar inductor were used to form an LC resonator. On the sensing process, the intraocular pressure compresses the MEMS capacitor and changes the sensor's resonance frequency. This variation is directly related with the internal pressure of the eye. An external coil (antenna) is used for wireless powering and readout. The fabrication and characterization processes were carried out at the Clean Room Laboratory of the Universidad de los Andes. The Sensor fabrication materials were: fiberglass (FR4), copper and polydimethylsiloxane (PDMS). The sensor was tested from 0 to 40 mmHg showing a 160 kHz/mmHg sensibility. Sensor implantation surgery was successfully performed in a rabbit's eye at Clinica Barraquer in Bogotá. The rabbit has not shown any complications within three months after the surgery.
- 1 March 2013
- Published by Elsevier in Sensors and Actuators B: Chemical
- Vol. 178, 26-33
Low cost wireless passive microsensors for the detection of hazardous compounds in water systems for control and monitoring
- 1 March 2013
- Published by Elsevier in Sensors and Actuators B: Chemical
- Vol. 178, 26-33
Low cost wireless passive microsensors for the detection of hazardous compounds in water systems for control and monitoring