Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Syauqi Abdurrahman Abrori has a total of 57 co-authors. Here are the top co-authors by number of shared publications:

  • Brian Yuliarto

    Advanced Functional Materials Research Group, Faculty of Industrial Technology, Institut Teknologi Bandung, Bandung 40132, Indonesia

    6 shared publications
  • Ni Luh Wulan Septiani

    Research Center for Advanced Materials, National Research and Innovation Agency, Komplek PUSPIPTEK, Serpong, South Tangerang 15314, Banten, Indonesia

    4 shared publications
  • Christian Harito

    Industrial Engineering Department, BINUS Graduate Program—Master of Industrial Engineering, Bina Nusantara University, Jakarta 11480, Indonesia

    2 shared publications
  • Mochamad Zakki Fahmi

    Department of Chemistry, Airlangga University, Surabaya 60115, Indonesia

    2 shared publications
  • Angga Maulana

    Advanced Functional Materials Laboratory, Engineering Physics Department and Industrial Technology, Bandung Institute of Technology, Bandung, Indonesia

    1 shared publication
  • Brilly Andro Makalew

    1 shared publication

Latest Publications

  • Wearable Heart Rate Monitoring in Resource-Limited Healthcare

    by Syauqi Abrori

    Cardiovascular disease remains the primary cause of premature mortality in low- and middle-income countries, where structural barriers prevent timely detection of cardiac arrhythmias. Wearable sensing technologies, particularly photoplethysmography-based devices, offer a low-cost pathway toward continuous cardiac surveillance; however, their utility has historically depended on cloud-based inference pipelines incompatible with resource-limited environments. This chapter presents a comprehensive narrative review of the convergence of wearable cardiac monitoring and Tiny Machine Learning (TinyML), examining how compressed neural network models deployed on microcontroller-class hardware enable real-time arrhythmia detection without external connectivity. The review synthesizes evidence on sensing modalities, signal processing pipelines, model compression techniques, hardware platforms, and system-level deployment considerations, with specific attention to population diversity, regulatory context, and long-term sustainability.

  • Open Access

    Development of a Low-Cost Portable Exhaled Breath Ammonia Detector for Supplementary Five-Stage CKD Classification Using Embedded Threshold Logic

    by Winda Astuti, Juan Alexander Kwan, Elioenai Sitepu, Syauqi Abdurrahman Abrori, Feri Setiawan

    Conventional diagnosis of chronic kidney disease (CKD) relies predominantly on invasive blood-based examinations, limiting the scalability of kidney health screening in resource-constrained environments. This study presents embedded engineering framework for non-invasive, breath-based CKD staging framework supported by machine learning and implemented on a low-cost embedded platform. To account for physiological sex differences in baseline creatinine production, estimated glomerular filtration rate (eGFR) values and breath ammonia concentrations were derived from two independent clinical cohorts using sex-specific MDRD equations (incorporating the standard male formula and the 0.742 female correction factor, respectively) and creatinine–BUN conversion models, with male- and female-parameterized algorithms developed in parallel. The resulting feature space was analyzed using four unsupervised clustering approaches to stratify subjects into five clinically meaningful kidney function stages. Stage-specific ammonia thresholds were implemented within an Arduino Nano-based prototype equipped with an MQ-137 gas sensor and OLED display, enabling real-time point-of-care classification. Dataset-level classification accuracy reached 82% for the male algorithm and 92% for the female algorithm. Hospital-based validation on 29 patients (22 male, 7 female) yielded a real-world testing accuracy of 90.5% (20/22) for male patients and 71.4% (5/7) for female patients, a discrepancy largely attributable to the small female sample size. Because the current evaluation lacks healthy control subjects and is constrained by sample size, these empirical results serve primarily to demonstrate hardware-software functional integration and real-world deployment feasibility rather than definitive clinical efficacy. Despite these preliminary, sample-limited clinical datasets, results suggest this approach holds promise as an accessible, non-invasive screening complement to conventional diagnostic pathways, particularly in low-resource healthcare settings.

  • Open Access

    3D-Printed Ankle Foot Orthosis (AFO) with Optimized Material and Design for Children with Cerebral Palsy

    by Putra Aji Pangestu, Christian Harito, Elioenai Sitepu, Safarudin Gazali Herawan, Syauqi Abdurrahman Abrori, Cokisela Christian Lumban Tobing

    Cerebral palsy (CP) often causes mobility limitations that require assistive devices such as Ankle Foot Orthoses (AFOs) to enhance functional stability. This study aims to develop an optimized 3D-printed AFO design that improves comfort, structural durability, and production efficiency for children with CP. The research applies a Design of Experiment approach using the Taguchi method to optimize 3D printing parameters, supported by tensile testing to identify the best material configuration. Design alternatives were prioritized using the Analytical Hierarchy Process, while Finite Element Analysis was conducted to evaluate mechanical performance under physiological loading. The selected PETG configuration (33% infill density and 0.15 mm layer thickness) demonstrated improved tensile strength and flexibility, contributing to enhanced structural behavior. A prototype was produced and validated using the Quebec User Evaluation of Satisfaction with Assistive Technology (QUEST) questionnaire. Results showed higher overall user satisfaction for the optimized 3D-printed AFO compared to conventional devices, particularly in safety, comfort, and durability. The integration of optimized material parameters, systematic design evaluation, and user-centered assessment provides an effective pathway toward improving AFO performance and supporting the mobility and quality of life of children with cerebral palsy.


  • Open Access

    Facet-controlled growth and soft-chemical exfoliation of two-dimensional titanium dioxide nanosheets

    by Christian Harito, Munawar Khalil, Leanddas Nurdiwijayanto, Ni Luh Wulan Septiani, Syauqi Abdurrahman Abrori, Budi Riza Putra, Syed Z. J. Zaidi, Takaaki Taniguchi, Brian Yuliarto, Frank C. Walsh

    A timely review covering facet-controlled growth and soft-chemical exfoliation of two-dimensional titanium dioxide nanosheets.


  • The potential application of cellulose acetate membrane for CO 2 adsorbent

    by Novitri Hastuti, Deni Shidqi Khaerudini, Erlina Nurul Aini, Ganis Lukmandaru, Jannatan Hisankusuma, Maximus Quinn Hertada, Maria Faeka Christiani, Muhamad Alif Razi, Syauqi Abdurrahman Abrori

    Numerous countries have deployed significant efforts to reduce the amount of CO2 released into the atmosphere. Carbon capture and storage is widely regarded as a mitigation technique that can significantly reduce CO2 emissions. A crucial stage in carbon capture and storage is CO2 adsorption using a membrane. Cellulose acetate has demonstrated excellent properties as a membrane material. In this study, we examined the potential of cellulose acetate membrane (CAM) for CO2 gas capture. Two forms of CAM were developed for this study, with and without the addition of glycerol. Scanning Electron Microscope (SEM), Fourier Transform Infrared (FTIR), and CO2 adsorption analyses were used to characterise CAM in numerous ways. The analysis revealed that the addition of glycerol improved the gas adsorption properties of the material. The incorporation of glycerol into the cellulose acetate matrix resulted in an observed augmentation in both the diameter and pore size. The adsorption properties of CO2 are significantly influenced by the microscopic structure of the cellulose acetate membrane. The CAM can be viewed as a possible material for CO2 adsorbers. [GRAPHICS]


  • Open Access

    A graphene-modified Co-BDC metal-organic frameworks (Co-MOF) for electrochemical non-enzymatic glucose sensing

    by R Yuniasari, F Amri, S A Abrori, N L W Septiani, M Rezki, Irzaman Irzaman, M Z Fahmi, B Yuliarto

    In this work, a metal-organic framework (MOF) based on cobalt was decorated with graphene and used as a sensing material for glucose determination with electrochemical principles. The selection of Co-MOF material is based on its porous nature, large surface area, and excellent electrochemical properties. The combination of Co-MOF with graphene (high conductivity) effectively increased the electrochemical sensor current. The fabricated composite owned the good crystallinity with graphene particles attached to the Co-MOF surface. The biosensing performance was evaluated by cyclic voltammetry (CV) with 0.1 M NaOH solution as the bolstering electrolyte. The electrochemical measurement indicated that the prepared materials possessed a well-moved transfer electron between the electrode surface and electrolyte solution. The Co-BDC-3Gr sample obtained the best electrochemical performance with the lowest limit of detection (LOD) of 5.39 μM and the highest sensitivity of 100.49 μA mM-1 cm-2. The selectivity test of the modified Co-MOF was done by comparing the response with other compounds such as dopamine, uric acid, and NaCl. The acquired biosensor had excellent stability, with 93% of the initial response after 30 days of storage.


  • Review—A Pollutant Gas Sensor Based On Fe 3 O 4 Nanostructures: A Review

    by Juliandi Siregar, Ni Luh Wulan Septiani, Syauqi Abdurrahman Abrori, Kerista Sebayang, Irzaman, Mochammad Zakki Fahmi, Syahrul Humaidi, Timbangen Sembiring, Kurnia Sembiring, Brian Yuliarto, et al.

    Magnetite (Fe 3 O 4 ) nanostructures and their modifications with other materials show proper characteristics to be implemented as a sensing material. This paper provides a brief review of the application of the Fe 3 O 4 nanostructures and their modifications as sensitive material for pollutant gas sensors. Several studies were highlighted to explain the past-to-present progress of materials development. Various synthesis procedures of the materials were also clearly explained. The application of pure Fe 3 O 4 nanostructures and their modification as sensitive materials in gas sensor devices to detect toxic gases is the main section of this paper. Last, the future prospects section summarized the materials’ development and provided a suggestion for future development.


  • Open Access

    Metal-Organic-Framework FeBDC-Derived Fe3O4 for Non-Enzymatic Electrochemical Detection of Glucose

    by Syauqi Abdurrahman Abrori, Ni Luh Wulan Septiani, Nugraha, Isa Anshori, Suyatman, Veinardi Suendo, Brian Yuliarto

    Present-day science indicates that developing sensors with excellent sensitivity and selectivity for detecting early signs of diseases is highly desirable. Electrochemical sensors offer a method for detecting diseases that are simpler, faster, and more accurate than conventional laboratory analysis methods. Primarily, exploiting non-noble-metal nanomaterials with excellent conductivity and large surface area is still an area of active research due to its highly sensitive and selective catalysts for electrochemical detection in enzyme-free sensors. In this research, we successfully fabricate Metal-Organic Framework (MOF) FeBDC-derived Fe3O4 for non-enzymatic electrochemical detection of glucose. FeBDC synthesis was carried out using the solvothermal method. FeCl2.4H2O and Benzene-1,4-dicarboxylic acid (H2BDC) are used as precursors to form FeBDC. The materials were further characterized utilizing X-ray Powder Diffraction (XRD), Scanning Electron Microscopy (SEM), and Fourier-Transform Infrared Spectroscopy (FTIR). The resulting MOF yields good crystallinity and micro-rod like morphology. Electrochemical properties were tested using Cyclic Voltammetry (CV) and Differential Pulse Voltammetry (DPV) with a 0.1 M of Phosphate Buffer Saline (PBS pH 7.4) solution as the supporting electrolyte. The measurement results show the reduction and oxidation peaks in the CV curve of FeBDC, as well as Fe3O4. Pyrolysis of FeBDC to Fe3O4 increases the peak of oxidation and reduction currents. The Fe3O4 sample obtained has a sensitivity of 4.67 µA mM−1.cm−2, a linear range between 0.0 to 9.0 mM, and a glucose detection limit of 15.70 µM.