Mina Ghahrchi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Mina Ghahrchi has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
- Yousef Dadban Shahamat
Environmental Health Research Center, Golestan University of Medical Sciences, Gorgan, Iran; Department of Environmental Health Engineering, School of Health, Golestan University of Medical Sciences, Gorgan, Iran
4 shared publications - Farshad Hamidi
Department of Environmental Health Engineering, School of Public Health, Tehran University of Medical Sciences, Tehran, Iran
2 shared publications - Ali Zafarzadeh
Environmental Health Research Center, Golestan University of Medical Sciences, Gorgan, Iran; Department of Environmental Health Engineering, School of Health, Golestan University of Medical Sciences, Gorgan, Iran
1 shared publication - Bahman Ramavandi
Systems Environmental Health and Energy Research Center, The Persian Gulf Biomedical Sciences Research Institute, Bushehr University of Medical Sciences, Bushehr, Iran
1 shared publication Behruz Adamiyat Badan
Lamei Gorgani Institute of Higher Education, Gorgan, Iran
1 shared publication- Edris Bazrafshan
Health Sciences Research Center, Torbat Heydariyeh University of Medical Sciences, Torbat Heydariyeh, Iran
1 shared publication
Latest Publications
- 15 November 2021
- Published by Taylor & Francis in Human and Ecological Risk Assessment: An International Journal
- Vol. 27 (9-10) , 2311-2327
Description of BTEX concentrations with wind roses in Tehran city: the study of monitoring, GIS-zoning maps and risk assessment
In the present study, the emission of BTEX compounds has been investigated in a one-year period (2016–2017) in Tehran city. According to, 26 sampling stations were selected in different parts of the city and had been sampled in four seasons of year to determine the concentration of BTEX as well as other meteorological parameters such as temperature, humidity and wind speed. Spatial distribution analysis of BTEX was introduced by using the Inverse Distance Weighting (IDW) method in Arc GIS 10.3. Also, to determine the carcinogenic and non-carcinogenic risk of target compounds, Monte Carlo simulation was used. The results showed that the annual mean of benzene, toluene, ethylbenzene, m-xylene and o-xylene were 30.08 ± 21.97, 54.17 ± 40.29, 25.81 ± 15.21, 27.83 ± 19.1 and 23.16 ± 12.28 μg/m3, respectively. According to the result, the maximum and minimum concentrations of BTEX were in the center and north of the city, respectively. Temporally, the maximum value of BTEX was 232.61 ± 123.93 µg/m3 in the autumn and the minimum value was 57.88 ± 24.93 µg/m3 in the spring. The result obtains from the inhalation lifetime cancer risk (LTCR) indicative the carcinogenic potential of benzene. Noncarcinogenic risk index, namely the hazard quotient (HQ) for all BTEX compound except benzene concentration in the autumn (1.55), were lower than 1 degree so they were not harmful to human health. Graphical Abstract
- 15 November 2021
- Published by Taylor & Francis in Human and Ecological Risk Assessment: An International Journal
- Vol. 27 (9-10) , 2311-2327
Description of BTEX concentrations with wind roses in Tehran city: the study of monitoring, GIS-zoning maps and risk assessment
In the present study, the emission of BTEX compounds has been investigated in a one-year period (2016–2017) in Tehran city. According to, 26 sampling stations were selected in different parts of the city and had been sampled in four seasons of year to determine the concentration of BTEX as well as other meteorological parameters such as temperature, humidity and wind speed. Spatial distribution analysis of BTEX was introduced by using the Inverse Distance Weighting (IDW) method in Arc GIS 10.3. Also, to determine the carcinogenic and non-carcinogenic risk of target compounds, Monte Carlo simulation was used. The results showed that the annual mean of benzene, toluene, ethylbenzene, m-xylene and o-xylene were 30.08 ± 21.97, 54.17 ± 40.29, 25.81 ± 15.21, 27.83 ± 19.1 and 23.16 ± 12.28 μg/m3, respectively. According to the result, the maximum and minimum concentrations of BTEX were in the center and north of the city, respectively. Temporally, the maximum value of BTEX was 232.61 ± 123.93 µg/m3 in the autumn and the minimum value was 57.88 ± 24.93 µg/m3 in the spring. The result obtains from the inhalation lifetime cancer risk (LTCR) indicative the carcinogenic potential of benzene. Noncarcinogenic risk index, namely the hazard quotient (HQ) for all BTEX compound except benzene concentration in the autumn (1.55), were lower than 1 degree so they were not harmful to human health. Graphical Abstract
- 8 June 2021
- Published by Taylor & Francis in International Journal of Environmental Analytical Chemistry
- Vol. 103 (17) , 5282-5295
Optimisation of COD removal from the olive oil mill wastewater by combined electrocoagulation and peroxone process: modelling and determination of kinetic coefficients
The olive oil extraction industry is one of the most extensive industries, especially in the Mediterranean region. The wastewater produced in this industry contains high concentrations of organic pollutants, resistant and toxic compounds that, if not treated, can threaten the health of the environment. In the present study, the optimisation of the combined process of electrocoagulation and peroxone using central composite design of the response surface methodology with the help of Design-Expert V.11 The parameters of current density (0.06–0.73 A dm−2) and reaction time (5–45 min) in the process of electrocoagulation and the parameters of hydrogen peroxide concentration (4–12 ml) and reaction time (10–90 minutes) in the peroxone process were investigated on the COD removal efficiency. The design results showed that the quadratic model was significant for both processes and was determined as the selected model. The optimal conditions determined by the software in the process of electrocoagulation were 0.5 A dm−2 and 34 minutes and in the peroxone process, concentration of hydrogen peroxide and the time were obtained 12 ml and 62 minutes, respectively. In these conditions, the COD removal efficiency of the processes was determined 79.8% and 52.8%, respectively. Under optimal conditions, in peroxone process ozone consumption was reduced to 0.88 mg per mg of removed COD. Also, according to the results of Pseudo-first-order kinetics, constant rate increases with increasing of hydrogen peroxide concentration. The results obtained in this study were confirmed the application of electrocoagulation process along with advanced oxidation of proxone for effective treatment of effluents of this industry and similar industries.
- 8 June 2021
- Published by Taylor & Francis in International Journal of Environmental Analytical Chemistry
- Vol. 103 (17) , 5282-5295
Optimisation of COD removal from the olive oil mill wastewater by combined electrocoagulation and peroxone process: modelling and determination of kinetic coefficients
The olive oil extraction industry is one of the most extensive industries, especially in the Mediterranean region. The wastewater produced in this industry contains high concentrations of organic pollutants, resistant and toxic compounds that, if not treated, can threaten the health of the environment. In the present study, the optimisation of the combined process of electrocoagulation and peroxone using central composite design of the response surface methodology with the help of Design-Expert V.11 The parameters of current density (0.06–0.73 A dm−2) and reaction time (5–45 min) in the process of electrocoagulation and the parameters of hydrogen peroxide concentration (4–12 ml) and reaction time (10–90 minutes) in the peroxone process were investigated on the COD removal efficiency. The design results showed that the quadratic model was significant for both processes and was determined as the selected model. The optimal conditions determined by the software in the process of electrocoagulation were 0.5 A dm−2 and 34 minutes and in the peroxone process, concentration of hydrogen peroxide and the time were obtained 12 ml and 62 minutes, respectively. In these conditions, the COD removal efficiency of the processes was determined 79.8% and 52.8%, respectively. Under optimal conditions, in peroxone process ozone consumption was reduced to 0.88 mg per mg of removed COD. Also, according to the results of Pseudo-first-order kinetics, constant rate increases with increasing of hydrogen peroxide concentration. The results obtained in this study were confirmed the application of electrocoagulation process along with advanced oxidation of proxone for effective treatment of effluents of this industry and similar industries.
- 23 November 2020
- Published by Taylor & Francis in International Journal of Environmental Analytical Chemistry
- Vol. 102 (18) , 6892-6903
Determination and health risk assessment of heavy metals (Pb, Cd, Cu and Zn) in different brands of pasteurized milk
The contamination of milk and its products with heavy metals has toxic and dangerous effects on human health. This study aimed to determine the heavy metal concentration and health risk assessment resulting from them in four different brands of Pasteurized milk consumed in Gorgan city, Iran. This study was performed during three seasons (summer, autumn and winter). Sixty different samples of pasteurized milk of four common brands were selected and analysed. Samples were digested in the laboratory by using nitric acid method digestion, and the heavy metal concentration was measured by using the linear regression based on the height of the peaks of the voltammograms. Also, health risk assessment was analysed by Oracle® Crystal Ball. According to the results, the overall mean (n = 60) concentration of Pb, Cd, Cu and Zn in all of the analysed milk samples was 0.02, 0.023, 0.97 and 4.31 µg/g, respectively. Based on these results, about 67% had Pb content lower than the codex limits, almost 70% of all milk samples had Cd content higher than the permissible limit, and Cu concentration in all milk samples was under the mentioned permissible limits. Zn concentrations in all samples were exceeded the permissible limits. HRI values in adults and children via consumption of pasteurized milk in all of the analysed samples were within the safe limits (HRI < 1). Based on these findings, monitoring of contaminants in milk and other dairy products prevented the probably side effects of these heavy metals on human health.
- 23 November 2020
- Published by Taylor & Francis in International Journal of Environmental Analytical Chemistry
- Vol. 102 (18) , 6892-6903
Determination and health risk assessment of heavy metals (Pb, Cd, Cu and Zn) in different brands of pasteurized milk
The contamination of milk and its products with heavy metals has toxic and dangerous effects on human health. This study aimed to determine the heavy metal concentration and health risk assessment resulting from them in four different brands of Pasteurized milk consumed in Gorgan city, Iran. This study was performed during three seasons (summer, autumn and winter). Sixty different samples of pasteurized milk of four common brands were selected and analysed. Samples were digested in the laboratory by using nitric acid method digestion, and the heavy metal concentration was measured by using the linear regression based on the height of the peaks of the voltammograms. Also, health risk assessment was analysed by Oracle® Crystal Ball. According to the results, the overall mean (n = 60) concentration of Pb, Cd, Cu and Zn in all of the analysed milk samples was 0.02, 0.023, 0.97 and 4.31 µg/g, respectively. Based on these results, about 67% had Pb content lower than the codex limits, almost 70% of all milk samples had Cd content higher than the permissible limit, and Cu concentration in all milk samples was under the mentioned permissible limits. Zn concentrations in all samples were exceeded the permissible limits. HRI values in adults and children via consumption of pasteurized milk in all of the analysed samples were within the safe limits (HRI < 1). Based on these findings, monitoring of contaminants in milk and other dairy products prevented the probably side effects of these heavy metals on human health.
- 1 April 2020
- Published by Maad Rayan Publishing Company in Environmental Health Engineering and Management
- Vol. 7 (2) , 79-88
Application of heterogeneous catalytic ozonation process for treatment of high toxic effluent from a pesticide manufacturing plant
Background: The discharge of untreated wastewater containing toxic and resistant compounds into the environment is a serious threat for ecosystems. Therefore, this study was conducted to evaluate the treatment of poison production factory wastewater using heterogeneous catalytic ozonation process (COP). Methods: Magnetic carbon nanocomposite was used as a catalyst at concentrations of 1, 2, and 4 g/L. Its effect on improving the treatment process was evaluated at reaction time of 30, 60, 90, and 120 minutes. At the end of each experiment, parameters including total organic carbon (TOC), chemical oxygen demand (COD), biological oxygen demand (BOD5 ), pH, electrical conductivity (EC), and turbidity were measured. Results: It was revealed that in single ozonation process (SOP), the maximum removal efficiencies of TOC, COD, and BOD5 were achieved at reaction time of 120 minutes as 56%, 40%, and 11.7%, respectively. By adding the catalyst to the wastewater, the treatment process was improved, so that the maximum removal efficiencies of COD (91%), TOC (73%), and BOD5 (74%) were obtained at catalyst concentration of 4 g/L. Under this condition, BOD5 /COD ratio increased from 0.22 to 0.64. Also, the results of analysis of ozone consumption per each mg of reduced COD showed that its amount sharply decreased from 2.1 mgO3 / mg COD removal in the SOP, to 0.34 mgO3 /mg COD removal in the COP. The results of kinetic reaction analysis also revealed that the rate constant increased from 0.007 to 0.02 min-1. Conclusion: According to the results, it can be concluded that the COP at a catalyst concentration of 4 g/L, by decomposing resistant compounds and increasing the biodegradability, can be used as a suitable pretreatment method for biological processes.
- 1 April 2020
- Published by Maad Rayan Publishing Company in Environmental Health Engineering and Management
- Vol. 7 (2) , 79-88
Application of heterogeneous catalytic ozonation process for treatment of high toxic effluent from a pesticide manufacturing plant
Background: The discharge of untreated wastewater containing toxic and resistant compounds into the environment is a serious threat for ecosystems. Therefore, this study was conducted to evaluate the treatment of poison production factory wastewater using heterogeneous catalytic ozonation process (COP). Methods: Magnetic carbon nanocomposite was used as a catalyst at concentrations of 1, 2, and 4 g/L. Its effect on improving the treatment process was evaluated at reaction time of 30, 60, 90, and 120 minutes. At the end of each experiment, parameters including total organic carbon (TOC), chemical oxygen demand (COD), biological oxygen demand (BOD5 ), pH, electrical conductivity (EC), and turbidity were measured. Results: It was revealed that in single ozonation process (SOP), the maximum removal efficiencies of TOC, COD, and BOD5 were achieved at reaction time of 120 minutes as 56%, 40%, and 11.7%, respectively. By adding the catalyst to the wastewater, the treatment process was improved, so that the maximum removal efficiencies of COD (91%), TOC (73%), and BOD5 (74%) were obtained at catalyst concentration of 4 g/L. Under this condition, BOD5 /COD ratio increased from 0.22 to 0.64. Also, the results of analysis of ozone consumption per each mg of reduced COD showed that its amount sharply decreased from 2.1 mgO3 / mg COD removal in the SOP, to 0.34 mgO3 /mg COD removal in the COP. The results of kinetic reaction analysis also revealed that the rate constant increased from 0.007 to 0.02 min-1. Conclusion: According to the results, it can be concluded that the COP at a catalyst concentration of 4 g/L, by decomposing resistant compounds and increasing the biodegradability, can be used as a suitable pretreatment method for biological processes.