Salahaldin Alshatshati
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Salahaldin Alshatshati has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
Kevin P. Hallinan
University of Dayton, Dayton, OH
3 shared publicationsAdel Naji
University of Dayton, Dayton, OH
2 shared publicationsBadr Altarhuni
University of Dayton, Dayton, OH
2 shared publications- Abdulrahman Alanezi
Department of Mechanical & Aerospace Engineering, University of Dayton, Dayton, OH 45469-0238, USA
1 shared publication Abdulrahman Alrobaian
University of Dayton, Dayton, OH
1 shared publicationAbdulrahman Arlobaian
University of Dayton, Dayton, OH
1 shared publication
Latest Publications
- Open Access
- 31 August 2020
- Published by MDPI AG in Sustainability
- Vol. 12 (17) , 7110
Self-Learning Algorithm to Predict Indoor Temperature and Cooling Demand from Smart WiFi Thermostat in a Residential Building
Smart WiFi thermostats have moved well beyond the function they were originally designed for; namely, controlling heating and cooling comfort in buildings. They are now also learning from occupant behaviors and permit occupants to control their comfort remotely. This research seeks to go beyond this state of the art by utilizing smart WiFi thermostat data in residences to develop dynamic predictive models for room temperature and cooling/heating demand. These models can then be used to estimate the energy savings from new thermostat temperature schedules and estimate peak load reduction achievable from maintaining a residence in a minimum thermal comfort condition. Back Propagation Neural Network (BPNN), Long-Short Term Memory (LSTM), and Encoder-Decoder LSTM dynamic models are explored. Results demonstrate that LSTM outperforms BPNN and Encoder-Decoder LSTM approach, yielding and a MAE error of 0.5 °C, equal to the resolution error of the measured temperature. Additionally, the models developed are shown to be highly accurate in predicting savings from aggressive thermostat set point schedules, yielding deep reduction of up to 14.3% for heating and cooling, as well as significant energy reduction from curtailed thermal comfort in response to a high demand event.
- 31 August 2020
- Published by MDPI AG in Sustainability
- Vol. 12 (17) , 7110
Open AccessSelf-Learning Algorithm to Predict Indoor Temperature and Cooling Demand from Smart WiFi Thermostat in a Residential Building
Smart WiFi thermostats have moved well beyond the function they were originally designed for; namely, controlling heating and cooling comfort in buildings. They are now also learning from occupant behaviors and permit occupants to control their comfort remotely. This research seeks to go beyond this state of the art by utilizing smart WiFi thermostat data in residences to develop dynamic predictive models for room temperature and cooling/heating demand. These models can then be used to estimate the energy savings from new thermostat temperature schedules and estimate peak load reduction achievable from maintaining a residence in a minimum thermal comfort condition. Back Propagation Neural Network (BPNN), Long-Short Term Memory (LSTM), and Encoder-Decoder LSTM dynamic models are explored. Results demonstrate that LSTM outperforms BPNN and Encoder-Decoder LSTM approach, yielding and a MAE error of 0.5 °C, equal to the resolution error of the measured temperature. Additionally, the models developed are shown to be highly accurate in predicting savings from aggressive thermostat set point schedules, yielding deep reduction of up to 14.3% for heating and cooling, as well as significant energy reduction from curtailed thermal comfort in response to a high demand event.
- 26 June 2017
- Published by ASME International
Estimating Residential Wall Thermal Resistance From Exterior Thermal Imaging
Building energy audits are both expensive, on the order of $0.50(US)/sf [1], and there aren’t enough auditors to survey the entire building stock in the U.S. Needed are lower cost automated approaches for rapidly evaluating the energy effectiveness of buildings. A key element of such an approach would be automated measurements of envelope R-values. Proposed is the use of single point-in-time thermal images potentially obtainable from drive-by thermal imaging to infer wall and window R-values. A data mining based approach is proposed, which seeks to calibrate the measured exterior wall temperatures to known and measured R-values for a small subset of residences. In this approach, visual imagery is first used to determine the wall emissivity based on the color of the wall siding in order to yield an estimate of the wall temperature. A Random Forest model is developed using the training set comprised of the residences with known R-value. This model can then be used to estimate R- and C-values of other houses based upon their measured exterior temperatures. The results show that the proposed approach is capable of accurately estimating envelope thermal characteristics over a spectrum of envelope R-values and thermal capacitances present in residences nationally. The resulting error for the houses considered is maximally 12% using as few as nine training houses. The data mining approach has significantly greater accuracy than modeling-based approaches in the literature.
- 26 June 2017
- Published by ASME International
Estimating Residential Wall Thermal Resistance From Exterior Thermal Imaging
Building energy audits are both expensive, on the order of $0.50(US)/sf [1], and there aren’t enough auditors to survey the entire building stock in the U.S. Needed are lower cost automated approaches for rapidly evaluating the energy effectiveness of buildings. A key element of such an approach would be automated measurements of envelope R-values. Proposed is the use of single point-in-time thermal images potentially obtainable from drive-by thermal imaging to infer wall and window R-values. A data mining based approach is proposed, which seeks to calibrate the measured exterior wall temperatures to known and measured R-values for a small subset of residences. In this approach, visual imagery is first used to determine the wall emissivity based on the color of the wall siding in order to yield an estimate of the wall temperature. A Random Forest model is developed using the training set comprised of the residences with known R-value. This model can then be used to estimate R- and C-values of other houses based upon their measured exterior temperatures. The results show that the proposed approach is capable of accurately estimating envelope thermal characteristics over a spectrum of envelope R-values and thermal capacitances present in residences nationally. The resulting error for the houses considered is maximally 12% using as few as nine training houses. The data mining approach has significantly greater accuracy than modeling-based approaches in the literature.
- 26 June 2017
- Published by ASME International
Data Mining Approach for Estimating Residential Attic Thermal Resistance From Aerial Thermal Imagery, Utility Data, and Housing Data
Conventional residential building energy auditing needed to identify opportunities for energy savings is expensive and time consuming. On-site energy audits require quantification of envelope R-values, air and duct leakage, and heating and cooling system efficiencies. There is a need to advance lower cost automated approaches, which could include aerial and drive-by thermal imaging at-scale in an effort to measure the building R-value. However, single-point in time thermal images are generally qualitative, subject to errors stemming from building dynamics, background radiation, wind speed variation, night sky thermal radiation, and error in extracting temperature estimates from thermal images from surfaces with generally unknown emissivity. This work proposes two alternative approaches for estimating roof R-values from thermal imaging, one a physics based approach and the other a data-mining based approach. Both approaches employ aerial visual imagery to estimate the roof emissivity based on the color and type of roofing material, from which the temperature of the envelope can be estimated. The physics-based approach employs a dynamic energy model of the envelope with unknown R-value and thermal capacitance. These are tuned in order to predict the measured surface temperature at the time of the imaging, given the transient weather conditions prior to the imaging. The data-mining approach integrates the inferred temperature measurement, historical utility data, and easily accessible or potentially easily accessible housing data. A data mining regression model, trained from this data using residences with known R-values, is used to predict the roof R-value in the unknown houses. The data mining approach was shown to be a far superior approach, demonstrating an ability to estimate attic/roof R-value with an r-squared value of greater than 0.88 using as few as nine training houses. The implication of this research is significant, offering the possibility of auditing residences remotely at-scale via aerial and drive-by thermal imaging coupled with utility analysis.
- 26 June 2017
- Published by ASME International
Data Mining Approach for Estimating Residential Attic Thermal Resistance From Aerial Thermal Imagery, Utility Data, and Housing Data
Conventional residential building energy auditing needed to identify opportunities for energy savings is expensive and time consuming. On-site energy audits require quantification of envelope R-values, air and duct leakage, and heating and cooling system efficiencies. There is a need to advance lower cost automated approaches, which could include aerial and drive-by thermal imaging at-scale in an effort to measure the building R-value. However, single-point in time thermal images are generally qualitative, subject to errors stemming from building dynamics, background radiation, wind speed variation, night sky thermal radiation, and error in extracting temperature estimates from thermal images from surfaces with generally unknown emissivity. This work proposes two alternative approaches for estimating roof R-values from thermal imaging, one a physics based approach and the other a data-mining based approach. Both approaches employ aerial visual imagery to estimate the roof emissivity based on the color and type of roofing material, from which the temperature of the envelope can be estimated. The physics-based approach employs a dynamic energy model of the envelope with unknown R-value and thermal capacitance. These are tuned in order to predict the measured surface temperature at the time of the imaging, given the transient weather conditions prior to the imaging. The data-mining approach integrates the inferred temperature measurement, historical utility data, and easily accessible or potentially easily accessible housing data. A data mining regression model, trained from this data using residences with known R-values, is used to predict the roof R-value in the unknown houses. The data mining approach was shown to be a far superior approach, demonstrating an ability to estimate attic/roof R-value with an r-squared value of greater than 0.88 using as few as nine training houses. The implication of this research is significant, offering the possibility of auditing residences remotely at-scale via aerial and drive-by thermal imaging coupled with utility analysis.
- 26 June 2016
- Published by ASME International
Estimating Building Envelope Thermal Characteristics From Single-Point-in-Time Thermal Images
Energy efficiency programs implemented by utilities in the U.S. have rendered savings costing on average $0.03/kWh [1]. This cost is still well below energy generation costs. However, as the lowest cost energy efficiency measures are adopted, the cost effectiveness of further investment declines. Thus, there is a need to develop large-scale and relatively inexpensive energy auditing techniques to more efficiently find opportunities for savings. Currently, on-site building energy audits process are expensive, in the range of US$0.12/sf – $0.53/sf, and there is an insufficient number of professionals to perform the audits. Here we present research that addresses at community-wide scales the characterization of building envelope thermal characteristics via drive-by and fly-over GPS linked thermal imaging. A central question drives this research: Can single point-in-time thermal images be used to infer R-values and thermal capacitances of walls and roofs? Previous efforts to use thermal images to estimate R-values have been limited to stable exterior weather conditions. The approach posed here is based upon the development of a dynamic model of a building envelope component with unknown R-value and thermal capacitance. The weather conditions prior to the thermal image are used as inputs to the model. The model is solved to determine the exterior surface temperature, ultimately predicted the temperature at the thermal measurement time. The model R-value and thermal capacitance are tuned to force the error between the predicted surface temperature and the measured surface temperature from thermal imaging to be near zero. The results show that this methodology is capable of accurately estimating envelope thermal characteristics over a realistic spectrum of envelope R-values and thermal capacitance present in buildings nationally. With an assumed thermal image accuracy, thermal characteristics are predicted with a maximum error of respectively 20% and 14% for high and low R-values when the standard deviation of outside temperature over the previous 48 hours is as much as 5°C. Experimental validation on a test facility with variable surface materials was attempted under variable weather conditions, e.g., where the outdoor air temperature experiences varying fluctuations prior to imaging. The experimental validation realized errors less than 20% in predicting the R-value even when the standard deviation of outdoor temperature over the 48 hours prior to a measurement was approximately 5°C.
- 26 June 2016
- Published by ASME International
Estimating Building Envelope Thermal Characteristics From Single-Point-in-Time Thermal Images
Energy efficiency programs implemented by utilities in the U.S. have rendered savings costing on average $0.03/kWh [1]. This cost is still well below energy generation costs. However, as the lowest cost energy efficiency measures are adopted, the cost effectiveness of further investment declines. Thus, there is a need to develop large-scale and relatively inexpensive energy auditing techniques to more efficiently find opportunities for savings. Currently, on-site building energy audits process are expensive, in the range of US$0.12/sf – $0.53/sf, and there is an insufficient number of professionals to perform the audits. Here we present research that addresses at community-wide scales the characterization of building envelope thermal characteristics via drive-by and fly-over GPS linked thermal imaging. A central question drives this research: Can single point-in-time thermal images be used to infer R-values and thermal capacitances of walls and roofs? Previous efforts to use thermal images to estimate R-values have been limited to stable exterior weather conditions. The approach posed here is based upon the development of a dynamic model of a building envelope component with unknown R-value and thermal capacitance. The weather conditions prior to the thermal image are used as inputs to the model. The model is solved to determine the exterior surface temperature, ultimately predicted the temperature at the thermal measurement time. The model R-value and thermal capacitance are tuned to force the error between the predicted surface temperature and the measured surface temperature from thermal imaging to be near zero. The results show that this methodology is capable of accurately estimating envelope thermal characteristics over a realistic spectrum of envelope R-values and thermal capacitance present in buildings nationally. With an assumed thermal image accuracy, thermal characteristics are predicted with a maximum error of respectively 20% and 14% for high and low R-values when the standard deviation of outside temperature over the previous 48 hours is as much as 5°C. Experimental validation on a test facility with variable surface materials was attempted under variable weather conditions, e.g., where the outdoor air temperature experiences varying fluctuations prior to imaging. The experimental validation realized errors less than 20% in predicting the R-value even when the standard deviation of outdoor temperature over the 48 hours prior to a measurement was approximately 5°C.