Boram Lee
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Boram Lee has a total of 51 co-authors. Here are the top co-authors by number of shared publications:
Geon Oh
Department of Bioengineering, Korea University, Seoul, Republic of Korea
3 shared publications- Geon Oh
Proton Therapy Center, National Cancer Center, Goyang 10408, Korea
3 shared publications Dong‑Jin Kang
2 shared publicationsH.M. Cha
Environmental Radioactivity Assessment Team, KAERI, Daejeon, Republic of Korea
2 shared publicationsHakjae Lee
ARALE Laboratory Co., Ltd., Seoul, Republic of Korea
2 shared publicationsHunjung Kim
Department of Radiation Oncology, Inha University Hospital, 27, Inhang-Ro, Jung-Gu, Incheon, 22332, Republic of Korea
2 shared publications
Latest Publications
- 1 June 2025
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 20 (06) , P06030
Prompt-gamma tomographic imaging for range verification in pencil beam-scanning proton therapy
This study aimed to develop a prompt-gamma imaging system to verify the range of proton beams. We designed an optimized collimation system and calculated the proton range using the GATE nuclear-medicine simulation toolkit (v. 9.1). An initial system, which was devised using protons without including specific equipment models, was employed to assess proton beams with energy ranges of 80, 90, 100, 110, and 120 MeV. The gamma-camera system design does not interfere with the nozzle structure of the treatment equipment. It consists of a pinhole collimator and a BGO scintillator and has a 100 × 100-pixel array with a 0.5 mm× 0.5-mm pitch. Next, we constructed an entire system using 12 gamma camera systems for prompt-gamma detection. The pinhole collimator was optimized with respect to the 4.4-MeV prompt-gamma energy, considering the detection efficiency and full width at half maximum. Finally, the prompt-gamma rays at 2.2, 4.4, and 6.1 MeV were comparatively analyzed using an in-house program. Based on the simulation results, the pinhole collimator was optimized to a 1-cm height and 3-mm diameter. The peak of the 4.4-MeV prompt gamma and the reconstructed peak point matched within 1 mm for most simulated energies. These results showed that our newly proposed imaging system is capable of accurately monitoring the proton range using specific prompt-gamma energies.
- 1 June 2025
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 20 (06) , P06030
Prompt-gamma tomographic imaging for range verification in pencil beam-scanning proton therapy
This study aimed to develop a prompt-gamma imaging system to verify the range of proton beams. We designed an optimized collimation system and calculated the proton range using the GATE nuclear-medicine simulation toolkit (v. 9.1). An initial system, which was devised using protons without including specific equipment models, was employed to assess proton beams with energy ranges of 80, 90, 100, 110, and 120 MeV. The gamma-camera system design does not interfere with the nozzle structure of the treatment equipment. It consists of a pinhole collimator and a BGO scintillator and has a 100 × 100-pixel array with a 0.5 mm× 0.5-mm pitch. Next, we constructed an entire system using 12 gamma camera systems for prompt-gamma detection. The pinhole collimator was optimized with respect to the 4.4-MeV prompt-gamma energy, considering the detection efficiency and full width at half maximum. Finally, the prompt-gamma rays at 2.2, 4.4, and 6.1 MeV were comparatively analyzed using an in-house program. Based on the simulation results, the pinhole collimator was optimized to a 1-cm height and 3-mm diameter. The peak of the 4.4-MeV prompt gamma and the reconstructed peak point matched within 1 mm for most simulated energies. These results showed that our newly proposed imaging system is capable of accurately monitoring the proton range using specific prompt-gamma energies.
- 14 February 2025
- Published by Springer Nature in Journal of Imaging Informatics in Medicine
- Vol. 38 (6) , 3535-3547
Hybrid Approach to Classifying Histological Subtypes of Non-small Cell Lung Cancer (NSCLC): Combining Radiomics and Deep Learning Features from CT Images
This study aimed to develop a hybrid model combining radiomics and deep learning features derived from computed tomography (CT) images to classify histological subtypes of non-small cell lung cancer (NSCLC). We analyzed CT images and radiomics features from 235 patients with NSCLC, including 110 with adenocarcinoma (ADC) and 112 with squamous cell carcinoma (SCC). The dataset was split into a training set (75%) and a test set (25%). External validation was conducted using the NSCLC-Radiomics database, comprising 24 patients each with ADC and SCC. A total of 1409 radiomics and 8192 deep features underwent principal component analysis (PCA) and ℓ2,1-norm minimization for feature reduction and selection. The optimal feature sets for classification included 27 radiomics features, 20 deep features, and 55 combined features (30 deep and 25 radiomics). The average area under the receiver operating characteristic curve (AUC) for radiomics, deep, and combined features were 0.6568, 0.6689, and 0.7209, respectively, across the internal and external test sets. Corresponding average accuracies were 0.6013, 0.6376, and 0.6564. The combined model demonstrated superior performance in classifying NSCLC subtypes, achieving higher AUC and accuracy in both test datasets. These results suggest that the proposed hybrid approach could enhance the accuracy and reliability of NSCLC subtype classification.
- 14 February 2025
- Published by Springer Nature in Journal of Imaging Informatics in Medicine
- Vol. 38 (6) , 3535-3547
Hybrid Approach to Classifying Histological Subtypes of Non-small Cell Lung Cancer (NSCLC): Combining Radiomics and Deep Learning Features from CT Images
This study aimed to develop a hybrid model combining radiomics and deep learning features derived from computed tomography (CT) images to classify histological subtypes of non-small cell lung cancer (NSCLC). We analyzed CT images and radiomics features from 235 patients with NSCLC, including 110 with adenocarcinoma (ADC) and 112 with squamous cell carcinoma (SCC). The dataset was split into a training set (75%) and a test set (25%). External validation was conducted using the NSCLC-Radiomics database, comprising 24 patients each with ADC and SCC. A total of 1409 radiomics and 8192 deep features underwent principal component analysis (PCA) and ℓ2,1-norm minimization for feature reduction and selection. The optimal feature sets for classification included 27 radiomics features, 20 deep features, and 55 combined features (30 deep and 25 radiomics). The average area under the receiver operating characteristic curve (AUC) for radiomics, deep, and combined features were 0.6568, 0.6689, and 0.7209, respectively, across the internal and external test sets. Corresponding average accuracies were 0.6013, 0.6376, and 0.6564. The combined model demonstrated superior performance in classifying NSCLC subtypes, achieving higher AUC and accuracy in both test datasets. These results suggest that the proposed hybrid approach could enhance the accuracy and reliability of NSCLC subtype classification.
- 1 April 2024
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 19 (04) , P04003
Feasibility study of real-time imaging of an Ir-192 source using compact gamma camera with curved diverging collimator for brachytherapy
Brachytherapy is a treatment method that requires the accurate positioning of a radioactive source to deliver high doses to a tumor while minimizing exposure to surrounding tissues. Herein, we propose a compact gamma camera system based on a diverging collimator for real-time source positioning during brachytherapy. In the process of developing and fabricating such a gamma camera system, Monte Carlo simulations for diverging and pinhole collimators are performed under conditions that are similar to the actual detection environment, with the camera-to-source distance set at 50 cm to verify the feasibility of the gamma camera. Full width at half maximum (FWHM) and signal-to-noise ratio (SNR) values are analyzed based on the horizontal and vertical profiles at each location as the source shifts stepwise from the center to the right and diagonal direction. On average, the diverging collimator had FWHM values of 18 and 13 mm and SNR values of 30 and 31, while the pinhole collimator had FWHM values of 26 and 25 mm and SNR values of 47 and 46 when profiled horizontally and vertically. The diverging collimator has a lower SNR than pinhole collimator but performs better in terms of spatial resolution. Additionally, to test the performance of the manufactured gamma camera, the distance between the camera and the source was set to 100 cm and an experiment was conducted. The experimental results exhibit a trend similar to the simulation. Numerically, the average FWHM value were 39 mm in the vertical direction and 71 mm in the horizontal direction. Additionally, the average SNR values were 27 for the vertical direction and 17 for the horizontal direction. Based on these results, we confirm the possibility of Ir-192 source imaging.
- 1 April 2024
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 19 (04) , P04003
Feasibility study of real-time imaging of an Ir-192 source using compact gamma camera with curved diverging collimator for brachytherapy
Brachytherapy is a treatment method that requires the accurate positioning of a radioactive source to deliver high doses to a tumor while minimizing exposure to surrounding tissues. Herein, we propose a compact gamma camera system based on a diverging collimator for real-time source positioning during brachytherapy. In the process of developing and fabricating such a gamma camera system, Monte Carlo simulations for diverging and pinhole collimators are performed under conditions that are similar to the actual detection environment, with the camera-to-source distance set at 50 cm to verify the feasibility of the gamma camera. Full width at half maximum (FWHM) and signal-to-noise ratio (SNR) values are analyzed based on the horizontal and vertical profiles at each location as the source shifts stepwise from the center to the right and diagonal direction. On average, the diverging collimator had FWHM values of 18 and 13 mm and SNR values of 30 and 31, while the pinhole collimator had FWHM values of 26 and 25 mm and SNR values of 47 and 46 when profiled horizontally and vertically. The diverging collimator has a lower SNR than pinhole collimator but performs better in terms of spatial resolution. Additionally, to test the performance of the manufactured gamma camera, the distance between the camera and the source was set to 100 cm and an experiment was conducted. The experimental results exhibit a trend similar to the simulation. Numerically, the average FWHM value were 39 mm in the vertical direction and 71 mm in the horizontal direction. Additionally, the average SNR values were 27 for the vertical direction and 17 for the horizontal direction. Based on these results, we confirm the possibility of Ir-192 source imaging.
- Open Access
- 25 March 2024
- Published by Frontiers Media SA in Frontiers in Physiology
- Vol. 15, 1302301
Monte Carlo simulation study of an in vivo four-dimensional tracking system with a diverging collimator for monitoring radiation source (Ir-192) location during brachytherapy: proof of concept and feasibility
Introduction: The aim of this study was to demonstrate the potential of an in vivo four-dimensional (4D) tracking system to accurately localize the radiation source, Iridium-192 (Ir-192) in high-dose rate brachytherapy.Methods: To achieve time-dependent 3D positioning of the Ir-192 source, we devised a 4D tracking system employing multiple compact detectors. During the system’s design phase, we conducted comprehensive optimization and analytical evaluations of the diverging collimator employed for detection purposes. Subsequently, we executed 3D reconstruction and positioning procedures based on the 2D images obtained by six detectors, each equipped with an optimized diverging collimator. All simulations for designing and evaluating the 4D tracking system were performed using the open-source GATE (v9.1) Monte Carlo platform based on the GEANT4 (v10.7) toolkit. In addition, to evaluate the accuracy of the proposed 4D tracking system, we conducted simulations and 3D positioning using a solid phantom and patient data. Finally, the error between the reconstructed position coordinates determined by the tracking system and the original coordinates of the Ir-192 radiation source was analyzed.Results: The parameters for the optimized diverging collimator were a septal thickness of 0.3 mm and a collimator height of 30 mm. A tracking system comprising 6 compact detectors was designed and implemented utilizing this collimator. Analysis of the accuracy of the proposed Ir-192 source tracking system found that the average of the absolute values of the error between the 3D reconstructed and original positions for the simulation with the solid phantom were 0.440 mm for the x coordinate, 0.423 mm for the y coordinate, and 0.764 mm for the z coordinate, and the average Euclidean distance was 1.146 mm. Finally, in a simulation based on data from a patient who underwent brachytherapy, the average Euclidean distance between the original and reconstructed source position was 0.586 mm.Discussion: These results indicated that the newly designed in vivo 4D tracking system for monitoring the Ir-192 source during brachytherapy could determine the 3D position of the radiation source in real time during treatment. We conclude that the proposed positioning system has the potential to make brachytherapy more accurate and reliable.
- 25 March 2024
- Published by Frontiers Media SA in Frontiers in Physiology
- Vol. 15, 1302301
Open AccessMonte Carlo simulation study of an in vivo four-dimensional tracking system with a diverging collimator for monitoring radiation source (Ir-192) location during brachytherapy: proof of concept and feasibility
Introduction: The aim of this study was to demonstrate the potential of an in vivo four-dimensional (4D) tracking system to accurately localize the radiation source, Iridium-192 (Ir-192) in high-dose rate brachytherapy.Methods: To achieve time-dependent 3D positioning of the Ir-192 source, we devised a 4D tracking system employing multiple compact detectors. During the system’s design phase, we conducted comprehensive optimization and analytical evaluations of the diverging collimator employed for detection purposes. Subsequently, we executed 3D reconstruction and positioning procedures based on the 2D images obtained by six detectors, each equipped with an optimized diverging collimator. All simulations for designing and evaluating the 4D tracking system were performed using the open-source GATE (v9.1) Monte Carlo platform based on the GEANT4 (v10.7) toolkit. In addition, to evaluate the accuracy of the proposed 4D tracking system, we conducted simulations and 3D positioning using a solid phantom and patient data. Finally, the error between the reconstructed position coordinates determined by the tracking system and the original coordinates of the Ir-192 radiation source was analyzed.Results: The parameters for the optimized diverging collimator were a septal thickness of 0.3 mm and a collimator height of 30 mm. A tracking system comprising 6 compact detectors was designed and implemented utilizing this collimator. Analysis of the accuracy of the proposed Ir-192 source tracking system found that the average of the absolute values of the error between the 3D reconstructed and original positions for the simulation with the solid phantom were 0.440 mm for the x coordinate, 0.423 mm for the y coordinate, and 0.764 mm for the z coordinate, and the average Euclidean distance was 1.146 mm. Finally, in a simulation based on data from a patient who underwent brachytherapy, the average Euclidean distance between the original and reconstructed source position was 0.586 mm.Discussion: These results indicated that the newly designed in vivo 4D tracking system for monitoring the Ir-192 source during brachytherapy could determine the 3D position of the radiation source in real time during treatment. We conclude that the proposed positioning system has the potential to make brachytherapy more accurate and reliable.
- 30 December 2023
- Published by Korean Society of Radiological Science in Journal of Radiological Science and Technology
- Vol. 46 (6) , 527-533
Evaluation of Clinical Risk according to Multi-Leaf Collimator Positioning Error in Spinal Radiosurgery
- 30 December 2023
- Published by Korean Society of Radiological Science in Journal of Radiological Science and Technology
- Vol. 46 (6) , 527-533
Evaluation of Clinical Risk according to Multi-Leaf Collimator Positioning Error in Spinal Radiosurgery
- Open Access
- 1 August 2023
- Published by AIP Publishing in AIP Advances
- Vol. 13 (8)
Correlation between impulse magnitude and inhibition of cell proliferation in alternating electric fields therapy
This study was designed to investigate the correlation between the impulse by dielectrophoretic force applied inside a dividing cell during alternating electric fields therapy and the inhibition of cell proliferation. Distributions of the electric field and dielectrophoretic force inside a dividing cell were calculated using the finite element method of COMSOL Multiphysics. Based on the results, the average magnitude of the impulse by the dielectrophoretic force applied to the cleavage furrow inside a dividing cell placed in various directions was calculated as a function of electric field intensity at an extracellular reference point. The simulation results showed that the average magnitude of the impulse to the cleavage furrow inside a dividing cell ranged from 1.51 × 10−9 to 1.49 × 10−7 N s when tumor treating fields with an intensity ranging from 0.1 to 1 V/cm is applied at an extracellular reference point for 6 h. To verify the relationships between the impulse by the dielectrophoretic force and the inhibition of cell proliferation, the survival fractions of the four cancer cell lines were determined as a function of intensity and time duration of the electric field. The correlation between the magnitude and application time of the electric field and the survival fractions of the four cell lines showed similar trends in vitro. These results suggest that both the dielectrophoretic force and the time required for the force to act are proportionally related to the inhibitory effect on dividing cells, enabling this impulse to be used as a reference to quantify the inhibition of cell proliferation.
- 1 August 2023
- Published by AIP Publishing in AIP Advances
- Vol. 13 (8)
Open AccessCorrelation between impulse magnitude and inhibition of cell proliferation in alternating electric fields therapy
This study was designed to investigate the correlation between the impulse by dielectrophoretic force applied inside a dividing cell during alternating electric fields therapy and the inhibition of cell proliferation. Distributions of the electric field and dielectrophoretic force inside a dividing cell were calculated using the finite element method of COMSOL Multiphysics. Based on the results, the average magnitude of the impulse by the dielectrophoretic force applied to the cleavage furrow inside a dividing cell placed in various directions was calculated as a function of electric field intensity at an extracellular reference point. The simulation results showed that the average magnitude of the impulse to the cleavage furrow inside a dividing cell ranged from 1.51 × 10−9 to 1.49 × 10−7 N s when tumor treating fields with an intensity ranging from 0.1 to 1 V/cm is applied at an extracellular reference point for 6 h. To verify the relationships between the impulse by the dielectrophoretic force and the inhibition of cell proliferation, the survival fractions of the four cancer cell lines were determined as a function of intensity and time duration of the electric field. The correlation between the magnitude and application time of the electric field and the survival fractions of the four cell lines showed similar trends in vitro. These results suggest that both the dielectrophoretic force and the time required for the force to act are proportionally related to the inhibitory effect on dividing cells, enabling this impulse to be used as a reference to quantify the inhibition of cell proliferation.
- 30 December 2022
- Published by Korean Society of Radiological Science in Journal of Radiological Science and Technology
- Vol. 45 (6) , 553-560
Clinical Risk Evaluation Using Dose Verification Program of Brachytherapy for Cervical Cancer
- 30 December 2022
- Published by Korean Society of Radiological Science in Journal of Radiological Science and Technology
- Vol. 45 (6) , 553-560
Clinical Risk Evaluation Using Dose Verification Program of Brachytherapy for Cervical Cancer
- Open Access
- 16 July 2022
- Published by Springer Nature in Radiation Oncology
- Vol. 17 (1) , 1-12
Assessment of dose perturbations for metal stent in photon and proton radiotherapy plans for hepatocellular carcinoma
Background: The present study aimed to investigate the dosimetric impact of metal stent for photon and proton treatment plans in hepatocellular carcinoma. Methods: With computed tomography data of a water-equivalent solid phantom, dose perturbation caused by a metal stent included in the photon and proton treatment of hepatocellular carcinoma was evaluated by comparing Eclipse and RayStation treatment planning system (TPS) to a Monte Carlo (MC) based dose calculator. Photon and proton plans were created with anterior–posterior/posterior-anterior (AP/PA) fields using a 6 MV beam and AP/PA fields of a wobbling beam using 150 MeV and a 10 cm ridge filter. The difference in dose distributions and dosimetric parameters were compared depending on the stent's positions (the bile duct (GB) and intestinal tract (GI)) and angles (0°, 45°, and 90°). Additionally, the dose variation in the target volume including the stent was comparatively evaluated through dose volume histogram (DVH) analysis. And the comparison of clinical cases was carried out in the same way. Results: Percentage differences in the dosimetric parameters calculated by MC ranged from − 7.0 to 3.9% for the photon plan and − 33.7 to 4.3% for the proton plan, depending on the angle at which the GB and GI stents were placed, compared to those without the stent. The maximum difference was observed at the minimum dose (Dmin), which was observed in both photon and proton plans in the GB and GI stents deployed at a 90° incidence angle. The parameter differences were greater in the proton plan than in photon plan. The target volume showed various dose variations depending on positions and angles of stent for both beams. Compared with no-stent, the doses within the target volume containing the GI and GB stents for the photon beam were overestimated in the high-dose area at 0°, nearly equal within 1% at 45°, and underestimated at 90°. These doses to the proton beam were underestimated at all angles, and the amount of underdose to the target volume increased with an increase in the stent angle. However, the difference was significantly greater with the proton plan than the photon plan. Conclusions: Dose perturbations within the target volume due to the presence of the metal stent were not observed in the TPS calculations for photon and proton beams, but MC was used to confirm that there are dose variations within the target volume. The MC results found that delivery of the treatment beam avoiding the stent was the best method to prevent target volume underdose.
- 16 July 2022
- Published by Springer Nature in Radiation Oncology
- Vol. 17 (1) , 1-12
Open AccessAssessment of dose perturbations for metal stent in photon and proton radiotherapy plans for hepatocellular carcinoma
Background: The present study aimed to investigate the dosimetric impact of metal stent for photon and proton treatment plans in hepatocellular carcinoma. Methods: With computed tomography data of a water-equivalent solid phantom, dose perturbation caused by a metal stent included in the photon and proton treatment of hepatocellular carcinoma was evaluated by comparing Eclipse and RayStation treatment planning system (TPS) to a Monte Carlo (MC) based dose calculator. Photon and proton plans were created with anterior–posterior/posterior-anterior (AP/PA) fields using a 6 MV beam and AP/PA fields of a wobbling beam using 150 MeV and a 10 cm ridge filter. The difference in dose distributions and dosimetric parameters were compared depending on the stent's positions (the bile duct (GB) and intestinal tract (GI)) and angles (0°, 45°, and 90°). Additionally, the dose variation in the target volume including the stent was comparatively evaluated through dose volume histogram (DVH) analysis. And the comparison of clinical cases was carried out in the same way. Results: Percentage differences in the dosimetric parameters calculated by MC ranged from − 7.0 to 3.9% for the photon plan and − 33.7 to 4.3% for the proton plan, depending on the angle at which the GB and GI stents were placed, compared to those without the stent. The maximum difference was observed at the minimum dose (Dmin), which was observed in both photon and proton plans in the GB and GI stents deployed at a 90° incidence angle. The parameter differences were greater in the proton plan than in photon plan. The target volume showed various dose variations depending on positions and angles of stent for both beams. Compared with no-stent, the doses within the target volume containing the GI and GB stents for the photon beam were overestimated in the high-dose area at 0°, nearly equal within 1% at 45°, and underestimated at 90°. These doses to the proton beam were underestimated at all angles, and the amount of underdose to the target volume increased with an increase in the stent angle. However, the difference was significantly greater with the proton plan than the photon plan. Conclusions: Dose perturbations within the target volume due to the presence of the metal stent were not observed in the TPS calculations for photon and proton beams, but MC was used to confirm that there are dose variations within the target volume. The MC results found that delivery of the treatment beam avoiding the stent was the best method to prevent target volume underdose.
- Open Access
- 12 June 2021
- Published by Springer Nature in Radiation Oncology
- Vol. 16 (1) , 1-11
Development of clinical application program for radiotherapy induced cancer risk calculation using Monte Carlo engine in volumetric-modulated arc therapy
Background: The purpose of this study is to develop a clinical application program that automatically calculates the effect for secondary cancer risk (SCR) of individual patient. The program was designed based on accurate dose calculations using patient computed tomography (CT) data and Monte Carlo engine. Automated patient-specific evaluation program was configured to calculate SCR. Methods: The application program is designed to re-calculate the beam sequence of treatment plan using the Monte Carlo engine and patient CT data, so it is possible to accurately calculate and evaluate scatter and leakage radiation, difficult to calculate in TPS. The Monte Carlo dose calculation system was performed through stoichiometric calibration using patient CT data. The automatic SCR evaluation program in application program created with a MATLAB was set to analyze the results to calculate SCR. The SCR for organ of patient was calculated based on Biological Effects of Ionizing Radiation (BEIR) VII models. The program is designed to sequentially calculate organ equivalent dose (OED), excess absolute risk (EAR), excess relative risk (ERR), and the lifetime attributable risk (LAR) in consideration of 3D dose distribution analysis. In order to confirm the usefulness of the developed clinical application program, the result values from clinical application program were compared with the manual calculation method used in the previous study. Results: The OED values calculated in program were calculated to be at most approximately 13.3% higher than results in TPS. The SCR result calculated by the developed clinical application program showed a maximum difference of 1.24% compared to the result of the conventional manual calculation method. And it was confirmed that EAR, ERR and LAR values can be easily calculated by changing the biological parameters. Conclusions: We have developed a patient-specific SCR evaluation program that can be used conveniently in the clinic. The program consists of a Monte Carlo dose calculation system for accurate calculation of scatter and leakage radiation and a patient-specific automatic SCR evaluation program using 3D dose distribution. The clinical application program that improved the disadvantages of the existing process can be used as an index for evaluating a patient treatment plan.
- 12 June 2021
- Published by Springer Nature in Radiation Oncology
- Vol. 16 (1) , 1-11
Open AccessDevelopment of clinical application program for radiotherapy induced cancer risk calculation using Monte Carlo engine in volumetric-modulated arc therapy
Background: The purpose of this study is to develop a clinical application program that automatically calculates the effect for secondary cancer risk (SCR) of individual patient. The program was designed based on accurate dose calculations using patient computed tomography (CT) data and Monte Carlo engine. Automated patient-specific evaluation program was configured to calculate SCR. Methods: The application program is designed to re-calculate the beam sequence of treatment plan using the Monte Carlo engine and patient CT data, so it is possible to accurately calculate and evaluate scatter and leakage radiation, difficult to calculate in TPS. The Monte Carlo dose calculation system was performed through stoichiometric calibration using patient CT data. The automatic SCR evaluation program in application program created with a MATLAB was set to analyze the results to calculate SCR. The SCR for organ of patient was calculated based on Biological Effects of Ionizing Radiation (BEIR) VII models. The program is designed to sequentially calculate organ equivalent dose (OED), excess absolute risk (EAR), excess relative risk (ERR), and the lifetime attributable risk (LAR) in consideration of 3D dose distribution analysis. In order to confirm the usefulness of the developed clinical application program, the result values from clinical application program were compared with the manual calculation method used in the previous study. Results: The OED values calculated in program were calculated to be at most approximately 13.3% higher than results in TPS. The SCR result calculated by the developed clinical application program showed a maximum difference of 1.24% compared to the result of the conventional manual calculation method. And it was confirmed that EAR, ERR and LAR values can be easily calculated by changing the biological parameters. Conclusions: We have developed a patient-specific SCR evaluation program that can be used conveniently in the clinic. The program consists of a Monte Carlo dose calculation system for accurate calculation of scatter and leakage radiation and a patient-specific automatic SCR evaluation program using 3D dose distribution. The clinical application program that improved the disadvantages of the existing process can be used as an index for evaluating a patient treatment plan.
- 1 September 2020
- Published by Elsevier in Physica Medica
- Vol. 77, 181-186
Clinical application of a gantry-attachable plastic scintillating plate dosimetry system in pencil beam scanning proton therapy beam monitoring
- 1 September 2020
- Published by Elsevier in Physica Medica
- Vol. 77, 181-186
Clinical application of a gantry-attachable plastic scintillating plate dosimetry system in pencil beam scanning proton therapy beam monitoring