Miguel Angel Garcia-Gonzalez
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Miguel Angel Garcia-Gonzalez has a total of 26 co-authors. Here are the top co-authors by number of shared publications:
- Juan Rarnos Castro
Universitat Politecnica de Catalunya
5 shared publications - Mireya Fernandez-Chimeno
Universitat Politècnica de Catalunya (UPC)
4 shared publications - Federico Guede-Fernández
Value for Health CoLAB, Lisboa, Portugal
3 shared publications - Lluis Capdevila
Laboratory of Sport Psychology, Department of Basic Psychology, Universitat Autònoma de Barcelona, Bellaterra, Spain
3 shared publications - Eva Parrado
Autonomous University of Barcelona
2 shared publications Juan Jose Ramos-Castro
2 shared publications
Latest Publications
- Open Access
- 5 July 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 12, 129994-130006
Using Ultra-Short-Term Heart Rate Variability (HRV) Analysis to Track Posture Changes
Body posture significantly influences heart rate variability (HRV) through the autonomic nervous system (ANS), which maintains hemodynamic stability by balancing sympathetic and parasympathetic activity. Postural changes affect blood distribution, consequently altering HRV. Previous studies indicated that a supine posture decreases sympathetic and increases parasympathetic activity while standing increases sympathetic and decreases parasympathetic activity. Sitting involves both systems’ activities. Recently, ultra-short-term HRV analysis has been used to track physiological changes for its practicality and real-time monitoring capabilities. This study recorded electrocardiogram (ECG) signals from 30 healthy adults in supine, sitting, and standing postures to monitor postural changes. After random extraction of the RR time series for each posture, 16 HRV metrics were calculated. Based on statistical analysis, the HRV metrics that showed the most significant changes in tracking posture were the mean RR, min RR, max RR, RMSDD, SD1, SD1/SD2, DFA α1, and alpha (α). Nevertheless, several HRV indices were inconsistent, indicating that these values depended on the length of the recording time window. In addition, classification performance deteriorated if it was not specifically tailored or calibrated for each participant. The findings of this study reveal that mean RR, RMSDD, and SD1 provided the best posture classification performance using the ultra-short-term HRV analysis. Among these indices, the most sensitive index was RMSDD, showing an 82% change when comparing lying to standing postures. The consistency of these HRV indices across different time windows suggests that these indices are largely independent of the time window and exhibit changes within the same range as those reported in previous studies.
- 5 July 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 12, 129994-130006
Open AccessUsing Ultra-Short-Term Heart Rate Variability (HRV) Analysis to Track Posture Changes
Body posture significantly influences heart rate variability (HRV) through the autonomic nervous system (ANS), which maintains hemodynamic stability by balancing sympathetic and parasympathetic activity. Postural changes affect blood distribution, consequently altering HRV. Previous studies indicated that a supine posture decreases sympathetic and increases parasympathetic activity while standing increases sympathetic and decreases parasympathetic activity. Sitting involves both systems’ activities. Recently, ultra-short-term HRV analysis has been used to track physiological changes for its practicality and real-time monitoring capabilities. This study recorded electrocardiogram (ECG) signals from 30 healthy adults in supine, sitting, and standing postures to monitor postural changes. After random extraction of the RR time series for each posture, 16 HRV metrics were calculated. Based on statistical analysis, the HRV metrics that showed the most significant changes in tracking posture were the mean RR, min RR, max RR, RMSDD, SD1, SD1/SD2, DFA α1, and alpha (α). Nevertheless, several HRV indices were inconsistent, indicating that these values depended on the length of the recording time window. In addition, classification performance deteriorated if it was not specifically tailored or calibrated for each participant. The findings of this study reveal that mean RR, RMSDD, and SD1 provided the best posture classification performance using the ultra-short-term HRV analysis. Among these indices, the most sensitive index was RMSDD, showing an 82% change when comparing lying to standing postures. The consistency of these HRV indices across different time windows suggests that these indices are largely independent of the time window and exhibit changes within the same range as those reported in previous studies.
- Open Access
- 16 February 2024
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 19 (2) , e0298354
On the use of fractional calculus to improve the pulse arrival time (PAT) detection when using photoplethysmography (PPG) and electrocardiography (ECG) signals
The pulse arrival time (PAT) has been considered a surrogate measure for pulse wave velocity (PWV), although some studies have noted that this parameter is not accurate enough. Moreover, the inter-beat interval (IBI) time series obtained from successive pulse wave arrivals can be employed as a surrogate measure of the RR time series avoiding the use of electrocardiogram (ECG) signals. Pulse arrival detection is a procedure needed for both PAT and IBI measurements and depends on the proper fiducial points chosen. In this paper, a new set of fiducial points that can be tailored using several optimization criteria is proposed to improve the detection of successive pulse arrivals. This set is based on the location of local maxima and minima in the systolic rise of the pulse wave after fractional differintegration of the signal. Several optimization criteria have been proposed and applied to high-quality recordings of a database with subjects who were breathing at different rates while sitting or standing. When a proper fractional differintegration order is selected by using the RR time series as a reference, the agreement between the obtained IBI and RR is better than that for other state-of-the-art fiducial points. This work tested seven different traditional fiducial points. For the agreement analysis, the median standard deviation of the difference between the IBI and RR time series is 5.72 ms for the proposed fiducial point versus 6.20 ms for the best-performing traditional fiducial point, although it can reach as high as 9.93 ms for another traditional fiducial point. Other optimization criteria aim to reduce the standard deviation of the PAT (7.21 ms using the proposed fiducial point versus 8.22 ms to 15.4 ms for the best- and worst-performing traditional fiducial points) or to minimize the standard deviation of the PAT attributable to breathing (3.44 ms using the proposed fiducial point versus 4.40 ms to 5.12 ms for best- and worst-performing traditional fiducial points). The use of these fiducial points may help to better quantify the beat-to-beat PAT variability and IBI time series.
- 16 February 2024
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 19 (2) , e0298354
Open AccessOn the use of fractional calculus to improve the pulse arrival time (PAT) detection when using photoplethysmography (PPG) and electrocardiography (ECG) signals
The pulse arrival time (PAT) has been considered a surrogate measure for pulse wave velocity (PWV), although some studies have noted that this parameter is not accurate enough. Moreover, the inter-beat interval (IBI) time series obtained from successive pulse wave arrivals can be employed as a surrogate measure of the RR time series avoiding the use of electrocardiogram (ECG) signals. Pulse arrival detection is a procedure needed for both PAT and IBI measurements and depends on the proper fiducial points chosen. In this paper, a new set of fiducial points that can be tailored using several optimization criteria is proposed to improve the detection of successive pulse arrivals. This set is based on the location of local maxima and minima in the systolic rise of the pulse wave after fractional differintegration of the signal. Several optimization criteria have been proposed and applied to high-quality recordings of a database with subjects who were breathing at different rates while sitting or standing. When a proper fractional differintegration order is selected by using the RR time series as a reference, the agreement between the obtained IBI and RR is better than that for other state-of-the-art fiducial points. This work tested seven different traditional fiducial points. For the agreement analysis, the median standard deviation of the difference between the IBI and RR time series is 5.72 ms for the proposed fiducial point versus 6.20 ms for the best-performing traditional fiducial point, although it can reach as high as 9.93 ms for another traditional fiducial point. Other optimization criteria aim to reduce the standard deviation of the PAT (7.21 ms using the proposed fiducial point versus 8.22 ms to 15.4 ms for the best- and worst-performing traditional fiducial points) or to minimize the standard deviation of the PAT attributable to breathing (3.44 ms using the proposed fiducial point versus 4.40 ms to 5.12 ms for best- and worst-performing traditional fiducial points). The use of these fiducial points may help to better quantify the beat-to-beat PAT variability and IBI time series.
- Open Access
On the estimation of beat-to-beat time domain heart rate variability indices from smoothed heart rate time series
This study tests the feasibility of estimating some time-domain heart rate variability indices (the standard deviation of the RR time series, SDNN, and the standard deviation of the differentiated RR time series, or RMSSD) from smoothed and rounded to the nearest beat per minute heart period time series using shallow neural networks. These time series are often stored in wearable devices instead of the beat-to-beat RR time series. Because the algorithm for obtaining the recorded mean heart rate in wearable devices is often not disclosed, this study test different hypothetic sampling strategies and smoothers. Sixteen features extracted from 5 minute smoothed heart period time series were employed to train, validate, and test shallow neural networks in order to provide estimates of the SDNN and RMSSD indices from freely available public databases RR time series. The results show that, using the proposed features, the median relative error (averaged for each database) in the SDNN ranges from 2% to 14% depending on the smoothness, sampling strategy, and database. The RMSSD is harder to estimate, and its median relative error ranges from 6% to 32%. The proposed methodology can be easily extended to other averaged heart rate time series, HRV indices and supervised learning algorithms
Open AccessOn the estimation of beat-to-beat time domain heart rate variability indices from smoothed heart rate time series
This study tests the feasibility of estimating some time-domain heart rate variability indices (the standard deviation of the RR time series, SDNN, and the standard deviation of the differentiated RR time series, or RMSSD) from smoothed and rounded to the nearest beat per minute heart period time series using shallow neural networks. These time series are often stored in wearable devices instead of the beat-to-beat RR time series. Because the algorithm for obtaining the recorded mean heart rate in wearable devices is often not disclosed, this study test different hypothetic sampling strategies and smoothers. Sixteen features extracted from 5 minute smoothed heart period time series were employed to train, validate, and test shallow neural networks in order to provide estimates of the SDNN and RMSSD indices from freely available public databases RR time series. The results show that, using the proposed features, the median relative error (averaged for each database) in the SDNN ranges from 2% to 14% depending on the smoothness, sampling strategy, and database. The RMSSD is harder to estimate, and its median relative error ranges from 6% to 32%. The proposed methodology can be easily extended to other averaged heart rate time series, HRV indices and supervised learning algorithms
- Open Access
- 25 August 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 8, 154924-154939
Camera-Based Method for Respiratory Rhythm Extraction From a Lateral Perspective
This work proposes a new method based on computer vision algorithms to measure the respiratory rhythm of a subject from a lateral perspective. The proposed algorithm consists on tracking the motion of the intercostal and abdominal muscles by the means of dense optical flow, being the novelty of the proposed method the extraction of the respiratory signal from the phase of the optical flow, while extracting at the same time a quality index from the modulus. 15 healthy subjects were measured while seating, and 4 tests were performed for each subject involving different scenarios. The algorithm has been validated using a commercial wearable thorax inductive plethysmograph system. The instantaneous frequency for the constant frequency respiratory tests, and the breath to breath analysis and instantaneous frequency of the free breathing test have been computed to assess the performance and error of the proposed method for the respiratory acquisition. Finally, a statistical analysis has been performed to assess the accuracy and performance of the quality index. The results of the study show a high agreement between methods in the 0.1 Hz and 0.3 Hz test. For the Free breathing test, both the cycle by cycle and Instantaneous frequency results show a low error between methods with high sensitivity in the cycle detection. The hypothesis that the modulus of the optical flow could be used as a quality index has been corroborated, with very good statistical results. Moreover, due to the simplicity of the proposed algorithm, the proposed method can perform in real-time while measuring respiratory rhythm and assessing the quality of the acquired signal. Further studies taking into account external vibrations have to be performed, to assert that the proposed method can be used in demanding conditions.
- 25 August 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 8, 154924-154939
Open AccessCamera-Based Method for Respiratory Rhythm Extraction From a Lateral Perspective
This work proposes a new method based on computer vision algorithms to measure the respiratory rhythm of a subject from a lateral perspective. The proposed algorithm consists on tracking the motion of the intercostal and abdominal muscles by the means of dense optical flow, being the novelty of the proposed method the extraction of the respiratory signal from the phase of the optical flow, while extracting at the same time a quality index from the modulus. 15 healthy subjects were measured while seating, and 4 tests were performed for each subject involving different scenarios. The algorithm has been validated using a commercial wearable thorax inductive plethysmograph system. The instantaneous frequency for the constant frequency respiratory tests, and the breath to breath analysis and instantaneous frequency of the free breathing test have been computed to assess the performance and error of the proposed method for the respiratory acquisition. Finally, a statistical analysis has been performed to assess the accuracy and performance of the quality index. The results of the study show a high agreement between methods in the 0.1 Hz and 0.3 Hz test. For the Free breathing test, both the cycle by cycle and Instantaneous frequency results show a low error between methods with high sensitivity in the cycle detection. The hypothesis that the modulus of the optical flow could be used as a quality index has been corroborated, with very good statistical results. Moreover, due to the simplicity of the proposed algorithm, the proposed method can perform in real-time while measuring respiratory rhythm and assessing the quality of the acquired signal. Further studies taking into account external vibrations have to be performed, to assert that the proposed method can be used in demanding conditions.
- Open Access
- 14 December 2015
- Published by IOP Publishing in Physiological Measurement
- Vol. 37 (1) , 128-144
A methodology to quantify the differences between alternative methods of heart rate variability measurement
This work proposes a systematic procedure to report the differences between heart rate variability time series obtained from alternative measurements reporting the spread and mean of the differences as well as the agreement between measuring procedures and quantifying how stationary, random and normal the differences between alternative measurements are. A description of the complete automatic procedure to obtain a differences time series (DTS) from two alternative methods, a proposal of a battery of statistical tests, and a set of statistical indicators to better describe the differences in RR interval estimation are also provided. Results show that the spread and agreement depend on the choice of alternative measurements and that the DTS cannot be considered generally as a white or as a normally distributed process. Nevertheless, in controlled measurements the DTS can be considered as a stationary process.
- 14 December 2015
- Published by IOP Publishing in Physiological Measurement
- Vol. 37 (1) , 128-144
Open AccessA methodology to quantify the differences between alternative methods of heart rate variability measurement
This work proposes a systematic procedure to report the differences between heart rate variability time series obtained from alternative measurements reporting the spread and mean of the differences as well as the agreement between measuring procedures and quantifying how stationary, random and normal the differences between alternative measurements are. A description of the complete automatic procedure to obtain a differences time series (DTS) from two alternative methods, a proposal of a battery of statistical tests, and a set of statistical indicators to better describe the differences in RR interval estimation are also provided. Results show that the spread and agreement depend on the choice of alternative measurements and that the DTS cannot be considered generally as a white or as a normally distributed process. Nevertheless, in controlled measurements the DTS can be considered as a stationary process.
- 1 January 2015
- Published by Springer Nature
- p. 893-896
Assessment of Energy Expended in Physical Activity by a Smartphone-Based System
- 1 January 2015
- Published by Springer Nature
- p. 893-896
Assessment of Energy Expended in Physical Activity by a Smartphone-Based System
- 1 January 2014
- Published by Springer Nature
- p. 962-964
Differences in QRS Locations due to ECG Lead: Relationship with Breathing
- 1 January 2014
- Published by Springer Nature
- p. 962-964
Differences in QRS Locations due to ECG Lead: Relationship with Breathing
- 1 July 2013
- Published by Elsevier in Computer Methods and Programs in Biomedicine
- Vol. 111 (1) , 33-40
An application of fractional differintegration to heart rate variability time series
- 1 July 2013
- Published by Elsevier in Computer Methods and Programs in Biomedicine
- Vol. 111 (1) , 33-40
An application of fractional differintegration to heart rate variability time series
- 1 August 2011
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 25 (1094687X) , 1933-1936
The effect of electrocardiographic lead choice on RR time series
Results of heart rate variability analysis depend on the quality of the initial RR time series that is measured only in one lead of the ECG. This work shows that RR time series can subtly change from lead to lead so the choice of the analyzed lead is another source of uncertainty. The standard deviation of the differences of two RR time series obtained from different leads can change from 0.5 ms to more than 20 ms depending on the amount of noise, the morphological changes of the QRS complexes, the strategies of fiducial point determination and the measured subject. This source of uncertainty is in healthy subjects greater than that associated to the sampling frequency of the ECG for sampling frequencies greater than 400 Hz.
- 1 August 2011
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 25 (1094687X) , 1933-1936
The effect of electrocardiographic lead choice on RR time series
Results of heart rate variability analysis depend on the quality of the initial RR time series that is measured only in one lead of the ECG. This work shows that RR time series can subtly change from lead to lead so the choice of the analyzed lead is another source of uncertainty. The standard deviation of the differences of two RR time series obtained from different leads can change from 0.5 ms to more than 20 ms depending on the amount of noise, the morphological changes of the QRS complexes, the strategies of fiducial point determination and the measured subject. This source of uncertainty is in healthy subjects greater than that associated to the sampling frequency of the ECG for sampling frequencies greater than 400 Hz.