Dongliang Nan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Dongliang Nan has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
- Hassan Haes Alhelou
School of Engineering, Massachusetts Institute of Technology (MIT), Cambridge, MA, USA
1 shared publication - Hongzhou Chen
The Electric Power Research Institute, State Grid Chongqing Electric Power Company, Chongqing 401123, China
1 shared publication - Kai Chen
College of Energy and Electrical Engineering, Hohai University, Nanjing 210098, China
1 shared publication - Kaike Wang
Electric Power Research Institute, State Grid Electric Power Co., Ltd., Urumqi 830011, China
1 shared publication - Lifei Ma
School of Control and Computer Science, North China Electric Power University, Beijing 102206, China
1 shared publication - Pierluigi Siano
Department of Power Electronics, Electrical Drives and Robotics of Silesian University of Technology, 44-100 Gliwice, Poland
1 shared publication
Latest Publications
- Open Access
Thermodynamic-Based Perceived Predictive Power Control for Renewable Energy Penetrated Resident Microgrids
Heating, ventilation, and air conditioning (HVAC) systems and microgrids have garnered significant attention in recent research, with temperature control and renewable energy integration emerging as key focus areas in urban distribution power systems. This paper proposes a robust predictive temperature control (RPTC) method and a microgrid control strategy incorporating asymmetrical challenges, including uneven power load distribution and uncertainties in renewable outputs. The proposed method leverages a thermodynamics-based R-C model to achieve precise indoor temperature regulation under external disturbances, while a multisource disturbance compensation mechanism enhances system robustness. Additionally, an HVAC load control model is developed to enable real-time dynamic regulation of airflow, facilitating second-level load response and improved renewable energy accommodation. A symmetrical power tracking and voltage support secondary controller is also designed to accurately capture and manage the fluctuating power demands of HVAC systems for supporting operations of distribution power systems. The effectiveness of the proposed method is validated through power electronics simulations in the Matlab/Simulink/SimPowerSystems environment, demonstrating its practical applicability and superior performance.
Open AccessThermodynamic-Based Perceived Predictive Power Control for Renewable Energy Penetrated Resident Microgrids
Heating, ventilation, and air conditioning (HVAC) systems and microgrids have garnered significant attention in recent research, with temperature control and renewable energy integration emerging as key focus areas in urban distribution power systems. This paper proposes a robust predictive temperature control (RPTC) method and a microgrid control strategy incorporating asymmetrical challenges, including uneven power load distribution and uncertainties in renewable outputs. The proposed method leverages a thermodynamics-based R-C model to achieve precise indoor temperature regulation under external disturbances, while a multisource disturbance compensation mechanism enhances system robustness. Additionally, an HVAC load control model is developed to enable real-time dynamic regulation of airflow, facilitating second-level load response and improved renewable energy accommodation. A symmetrical power tracking and voltage support secondary controller is also designed to accurately capture and manage the fluctuating power demands of HVAC systems for supporting operations of distribution power systems. The effectiveness of the proposed method is validated through power electronics simulations in the Matlab/Simulink/SimPowerSystems environment, demonstrating its practical applicability and superior performance.
- Open Access
Energy Storage Capacity Configuration Planning Considering Dual Scenarios of Peak Shaving and Emergency Frequency Regulation
New energy storage methods based on electrochemistry can not only participate in peak shaving of the power grid but also provide inertia and emergency power support. It is necessary to analyze the planning problem of energy storage from multiple application scenarios, such as peak shaving and emergency frequency regulation. This article proposes an energy storage capacity configuration planning method that considers both peak shaving and emergency frequency regulation scenarios. A frequency response model based on emergency frequency regulation combined with low-frequency load shedding is established, taking into account the frequency safety constraints of the system and the principle of idle time reuse, to establish a bi-level programming model. In the upper-level model, the optimization objective is to minimize the annual operating cost of the system during the planning period, combined with the constraints of power grid operation to plan the energy storage capacity. The lower-level model embeds frequency safety constraints with the optimization objective of minimizing the cost of fault losses. To solve the bi-level optimization problem, the Karush–Kuhn–Tucher (KKT) condition and Big-M method were used to transform the bi-level model into a single-layer linear model. Finally, an improved IEEE RTS-24 system was used for numerical verification. The results show that the method proposed in this article can reasonably plan the capacity of energy storage, improve frequency safety during system operation, and reduce the operating cost of the power grid.
Open AccessEnergy Storage Capacity Configuration Planning Considering Dual Scenarios of Peak Shaving and Emergency Frequency Regulation
New energy storage methods based on electrochemistry can not only participate in peak shaving of the power grid but also provide inertia and emergency power support. It is necessary to analyze the planning problem of energy storage from multiple application scenarios, such as peak shaving and emergency frequency regulation. This article proposes an energy storage capacity configuration planning method that considers both peak shaving and emergency frequency regulation scenarios. A frequency response model based on emergency frequency regulation combined with low-frequency load shedding is established, taking into account the frequency safety constraints of the system and the principle of idle time reuse, to establish a bi-level programming model. In the upper-level model, the optimization objective is to minimize the annual operating cost of the system during the planning period, combined with the constraints of power grid operation to plan the energy storage capacity. The lower-level model embeds frequency safety constraints with the optimization objective of minimizing the cost of fault losses. To solve the bi-level optimization problem, the Karush–Kuhn–Tucher (KKT) condition and Big-M method were used to transform the bi-level model into a single-layer linear model. Finally, an improved IEEE RTS-24 system was used for numerical verification. The results show that the method proposed in this article can reasonably plan the capacity of energy storage, improve frequency safety during system operation, and reduce the operating cost of the power grid.
- Open Access
Defect Texts Mining of Secondary Device in Smart Substation with GloVe and Attention-Based Bidirectional LSTM
In the process of the operation and maintenance of secondary devices in smart substation, a wealth of defect texts containing the state information of the equipment is generated. Aiming to overcome the low efficiency and low accuracy problems of artificial power text classification and mining, combined with the characteristics of power equipment defect texts, a defect texts mining method for a secondary device in a smart substation is proposed, which integrates global vectors for word representation (GloVe) method and attention-based bidirectional long short-term memory (BiLSTM-Attention) method in one model. First, the characteristics of the defect texts are analyzed and preprocessed to improve the quality of the defect texts. Then, defect texts are segmented into words, and the words are mapped to the high-dimensional feature space based on the global vectors for word representation (GloVe) model to form distributed word vectors. Finally, a text classification model based on BiLSTM-Attention was proposed to classify the defect texts of a secondary device. Precision, Recall and F1-score are selected as evaluation indicators, and compared with traditional machine learning and deep learning models. The analysis of a case study shows that the BiLSTM-Attention model has better performance and can achieve the intelligent, accurate and efficient classification of secondary device defect texts. It can assist the operation and maintenance personnel to make scientific maintenance decisions on a secondary device and improve the level of intelligent management of equipment.
Open AccessDefect Texts Mining of Secondary Device in Smart Substation with GloVe and Attention-Based Bidirectional LSTM
In the process of the operation and maintenance of secondary devices in smart substation, a wealth of defect texts containing the state information of the equipment is generated. Aiming to overcome the low efficiency and low accuracy problems of artificial power text classification and mining, combined with the characteristics of power equipment defect texts, a defect texts mining method for a secondary device in a smart substation is proposed, which integrates global vectors for word representation (GloVe) method and attention-based bidirectional long short-term memory (BiLSTM-Attention) method in one model. First, the characteristics of the defect texts are analyzed and preprocessed to improve the quality of the defect texts. Then, defect texts are segmented into words, and the words are mapped to the high-dimensional feature space based on the global vectors for word representation (GloVe) model to form distributed word vectors. Finally, a text classification model based on BiLSTM-Attention was proposed to classify the defect texts of a secondary device. Precision, Recall and F1-score are selected as evaluation indicators, and compared with traditional machine learning and deep learning models. The analysis of a case study shows that the BiLSTM-Attention model has better performance and can achieve the intelligent, accurate and efficient classification of secondary device defect texts. It can assist the operation and maintenance personnel to make scientific maintenance decisions on a secondary device and improve the level of intelligent management of equipment.