MGMarc Garetier

Marc Garetier

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Marc Garetier has a total of 111 co-authors. Here are the top co-authors by number of shared publications:

  • J. Rousset

    Service d’imagerie médicale, hôpital d’instruction des armées Clermont-Tonnerre, rue du Colonel-Fonferrier, CC 41, 29240 Brest cedex 9, France

    8 shared publications
  • Jean Rousset

    Department of Radiology, Military Teaching Hospital Clermont-Tonnerre, Brest, France

    7 shared publications
  • S. Chinellato

    Service d’imagerie médicale, hôpital d’instruction des armées Clermont-Tonnerre, rue du Colonel-Fonferrier, CC 41, 29240 Brest cedex 9, France

    6 shared publications
  • Douraied Ben Salem

    Univ Brest, UMR INSERM 1101 LaTIM, Neuroradiology, CHU Brest, Brest 29609 Cedex, France

    5 shared publications
  • Sandra Chinellato

    Department of Radiology, Clermont Tonnerre Military Hospital, Brest, France

    4 shared publications
  • Thierry Le Bivic

    4 shared publications

Latest Publications

  • Use of Instant Messaging Applications by General Practitioners During Overseas Deployment: A Survey of the French Military Health Service

    by Yannis Got, Bhushan Borotikar, Cécile Sandillon-Garétier, Anne Le Coat, Renaud Dulou, Marc Garétier

    Introduction: Instant messaging applications (MAs) represent a major component of modern telecommunications for data transmission. During overseas deployments, military doctors increasingly rely on MAs due to their availability and the urgent need to obtain advice from specialists for optimal patient management. In this study, we aimed to describe and analyze the context and usage characteristics of these MAs for transmitting medical data by military general practitioners (GPs) during overseas missions. Materials and Methods: This observational study was conducted between June 2020 and December 2020, based on a survey sent to GPs from the French Military Health Service who had been deployed overseas in military operations between 2010 and 2020. Results: We received 233 surveys of which 215 were analyzed. Among these, 141 military GPs used instant MAs to transmit medical data during deployment. Notably, WhatsApp was used by 97% of the participants. The military GPs mainly used these applications for the speed of exchanges (45%) and their ease of use (28%). The physician specialties predominantly involved in data sharing were trauma and orthopedic surgery (38%) and dermatology (31%). The correspondents were mainly military specialist physicians from French military teaching hospitals (85%). A response time of less than 1 h was reported in 78% of the cases. Additionally, 72 doctors (51%) undertook their last deployment in an isolated post. Conclusion: MAs were extensively utilized communication tools among GPs during their overseas deployments. Although the use of these applications seems essential in telemedicine, it raises several legal and ethical questions. Thus, we recommend employing these tools while ensuring medical and military confidentiality.


  • ACTIfit™ : 38 % de résorption complète à 8 ans de recul sur une cohorte de 18 cas

    by Antoine de Chanterac, Marc Garetier, François-Xavier Gunepin, Cécile Baynat, Marc Danguy Des Déserts, Arnaud Perchoc, Hoel Letissier, Christophe Andro

  • Assessment and comparison of image quality between two real-time sequences for dynamic MRI of distal joints at 3.0 Tesla

    by Marc Garetier, Jean Rousset, Karim Makki, Sylvain Brochard, François Rousseau, Douraïed Ben Salem, Bhushan Borotikar

    Background: Real-time sequences allow functional evaluation of various joint structures during a continuous motion and help understand the pathomechanics of underlying musculoskeletal diseases. Purpose: To assess and compare the image quality of the two most frequently used real-time sequences for joint dynamic magnetic resonance imaging (MRI), acquired during finger and ankle joint motion. Material and Methods: A real-time dynamic acquisition protocol, including radiofrequency (RF)-spoiled and balanced steady-state free precession (bSSFP) sequences, optimized for temporal resolution with similar spatial resolution, was performed using a 3.0-T MRI scanner on 10 fingers and 12 ankles from healthy individuals during active motion. Image quality criteria were evaluated on each time frame and compared between these two sequences. Signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were determined and compared from regions of interest placed on cortical bone, tendon, fat, and muscle. Visualization of anatomical structures and overall image quality appreciation were rated by two radiologists using a 0–10 grading scale. Results: Mean CNR was significantly higher with bSSFP sequence compared to RF-spoiled sequence. The grading score was in the range of 5–9.3 and was significantly higher with RF-spoiled sequence for bone and joint evaluation and overall image appreciation on the two joints. The standard deviation for SNR, CNR, and grading score during motion was smaller with RF-spoiled sequence for both the joints. The inter-reader reliability was excellent (>0.75) for evaluating anatomical structures in both sequences. Conclusion: A RF-spoiled real-time sequence is recommended for the in vivo clinical evaluation of distal joints on a 3.0-T MRI scanner.


  • Open Access

    Quantitative and qualitative optimisation of dosimetry in computed tomography explorations of the temporal bone using two iterative reconstruction algorithms

    by Olivier Legeas, David Bourhis, Marc Garetier, Adele Pennaneach, Philippe Meriot, Julien Ognard, Douraied Ben Salem


  • Efficacy of Chest CT for COVID-19 Pneumonia Diagnosis in France

    by Guillaume Herpe, Mathieu Lederlin, Mathieu Naudin, Mickaël Ohana, Kathia Chaumoitre, Jules Gregory, Valérie Vilgrain, Cornelia Anna Freitag, Constance De Margerie-Mellon, Violaine Flory, et al.

    Background The role and performance of chest CT in the diagnosis of the coronavirus disease 2019 (COVID-19) pandemic remains under active investigation. Purpose To evaluate the French national expe...


  • Open Access

    Dynamic MRI for articulating joint evaluation on 1.5 T and 3.0 T scanners: setup, protocols, and real-time sequences

    by Marc Garetier, Bhushan Borotikar, Karim Makki, Sylvain Brochard, François Rousseau, Douraïed Ben Salem

    Dynamic magnetic resonance imaging (MRI) is a non-invasive method that can be used to increase the understanding of the pathomechanics of joints. Various types of real-time gradient echo sequences used for dynamic MRI acquisition of joints include balanced steady-state free precession sequence, radiofrequency-spoiled sequence, and ultra-fast gradient echo sequence. Due to their short repetition time and echo time, these sequences provide high temporal resolution, a good signal-to-noise ratio and spatial resolution, and soft tissue contrast. The prerequisites of the evaluation of joints with dynamic MRI include suitable patient installation and optimal positioning of the joint in the coil to allow joint movement, sometimes with dedicated coil support. There are currently few recommendations in the literature regarding appropriate protocol, sequence standardizations, and diagnostic criteria for the use of real-time dynamic MRI to evaluate joints. This article summarizes the technical parameters of these sequences from various manufacturers on 1.5 T and 3.0 T MRI scanners. We have reviewed pertinent details of the patient and coil positioning for dynamic MRI of various joints. The indications and limitations of dynamic MRI of joints are discussed.


  • Postmortem computed tomography findings in suicide victims

    by M. Garetier, L. Deloire, F. Dédouit, E. Dumousset, C. Saccardy, D. Ben Salem


  • Mésocôlon descendant persistant

    by R. Cadieu, M. Garetier, F. Ropars, V. Tissot, S. Chinellato, J. Rousset

  • MR imaging findings of superficial venous aneurysm of the hand

    by M. Garetier, J.C. Moynot, C. Andro, A. Vicard, J. Rousset


  • Value of spontaneous hyperdensity of cerebral venous thrombosis on helical CT

    by Marc Garetier, Jean Rousset, Ernesto Pearson, Valentin Tissot, Jean-Christophe Gentric, Emmanuel Nowak, Jean-Christophe Ferre, Serge Timsit, Douraied Ben Salem

    Background Excluding a cerebral venous thrombosis (CVT) through imaging is a frequent request in the emergency setting. This assessment often starts by an unenhanced brain computed tomography (CT). Purpose Re-evaluate the value of spontaneous hyperdensity of CVT on helical unenhanced brain CT. Methods Multicentric retrospective study on CVT probability based on visual assessment of spontaneous hyperdensity of cerebral venous system, performed by four blinded radiologists, individually then collectively, on a population including 14 helical unenhanced brain CTs with CVT and 102 unenhanced brain CTs without CVT (all confirmed by CT or magnetic resonance [MR] venography). Exclusion criteria: no DICOM image, symptoms >15 days, CVT indirect signs on unenhanced CT. A fifth radiologist set 768 regions of interest to measure and to compare the density within the normal venous sinuses and the CVTs. Results After consensus reading, sensitivity of this sign for CVT diagnosis was 100%, specificity 95.1%, and negative predictive value (NPV) 100%, with high individual NPV (99–100%). Area under the receiver-operating characteristic curve was 0.992 after consensus (0.976–0.986 individually). The spontaneous density was significantly different (P 70 HU reported only within the CVTs, except for the horizontal part of the superior sagittal sinus (hSSS). Conclusion The dense triangle sign on helical unenhanced brain CT has an excellent NPV to exclude a sinus thrombosis during the first 2 weeks. However, we believe that visual assessment of spontaneous hyperdensity is not sufficient for the diagnosis of CVT, with possible false-positive of the hSSS on unenhanced CT.