JNJessica H. Nguyen

Jessica H. Nguyen

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Jessica H. Nguyen has a total of 21 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Capturing fine-grained details for video-based automation of suturing skills assessment

    by Andrew J. Hung, Richard Bao, Idris O. Sunmola, De-An Huang, Jessica H. Nguyen, Anima Anandkumar

    Objectives Manually-collected suturing technical skill scores are strong predictors of continence recovery after robotic radical prostatectomy. Herein, we automate suturing technical skill scoring through computer vision (CV) methods as a scalable method to provide feedback. Methods Twenty-two surgeons completed a suturing exercise three times on the Mimic™ Flex VR simulator. Instrument kinematic data (XYZ coordinates of each instrument and pose) were captured at 30 Hz. After standardized training, three human raters manually video segmented suturing task into four sub-stitch phases (Needle handling, Needle targeting, Needle driving, Needle withdrawal) and labeled the corresponding technical skill domains (Needle positioning, Needle entry, Needle driving, and Needle withdrawal). The CV framework extracted RGB features and optical flow frames using a pre-trained AlexNet. Additional CV strategies including auxiliary supervision (using kinematic data during training only) and attention mechanisms were implemented to improve performance. Results This study included data from 15 expert surgeons (median caseload 300 [IQR 165–750]) and 7 training surgeons (0 [IQR 0–8]). In all, 226 virtual sutures were captured. Automated assessments for Needle positioning performed best with the simplest approach (1 s video; AUC 0.749). Remaining skill domains exhibited improvements with the implementation of auxiliary supervision and attention mechanisms when deployed separately (AUC 0.604–0.794). All techniques combined produced the best performance, particularly for Needle driving and Needle withdrawal (AUC 0.959 and 0.879, respectively). Conclusions This study demonstrated the best performance of automated suturing technical skills assessment to date using advanced CV techniques. Future work will determine if a “human in the loop” is necessary to verify surgeon evaluations.


  • Virtual Reality vs Dry Laboratory Models: Comparing Automated Performance Metrics and Cognitive Workload During Robotic Simulation Training

    by Andrew Cowan, Jian Chen, Samuel Mingo, Sharath S. Reddy, Runzhuo Ma, Sandra Marshall, Jessica H. Nguyen, Andrew J. Hung

    Background This study compares surgical performance during analogous vesico-urethral anastomosis (VUA) tasks in two robotic training environments, virtual reality (VR) and dry-lab (DL), in order to investigate transferability of skills assessment across the two platforms. Utilizing computer-generated performance metrics and pupillary data we evaluated the two environments’ ability to distinguish surgical expertise and ultimately whether performance in the VR simulation correlates to performance on the live robot in the dry-lab. Materials and Methods Experts (≥ 300 cases) and trainees (<300) performed analogous VUAs during VR and dry-lab sessions on a da Vinci robotic console. 22 metrics were generated in each environment (kinematic metrics, tissue metrics, biometrics). The dry-lab included 18 previously validated automated performance metrics (APMs) (kinematics, events metrics) and were captured by an Intuitive systems data recorder. In both settings, Tobii Pro Glasses 2 recorded task-evoked pupillary response (reported as Index of Cognitive Activity [ICA]) to indicate cognitive workload, analyzed by EyeTracking Cognitive Workload Software. Pearson Correlation, Mann-Whitney and Independent t-tests were used for the comparative analyses. Results Our study included 6 experts (median caseload 1300 [interquartile range 400-3000]) and 11 trainees (25 [0-250]). 8/9 metrics directly comparable between VR and DL showed significant positive correlation (r≥0.554, p≤0.032). 5/22 VR metrics distinguished expertise including: task time (p=0.031), clutch usage (p=0.040), unnecessary needle piercings (p=0.026) and suspected injury to endopelvic fascia (p=0.040). This contrasts with 14/22 APMs in dry-lab (p≤0.038) including: linear velocities of all three instruments (p≤0.038) and dominant-hand instrument wrist articulation (p=0.013). Trainees experienced higher cognitive workload (ICA) in both environments when compared to experts (p<0.036). Conclusions A majority of performance metrics between VR and dry-lab exhibited moderate to strong correlations, showing transferability of skills across the platforms. Comparing training environments, APMs during dry-lab tasks are better able to distinguish expertise than VR-generated metrics.


  • Efficiency and Accuracy of Robotic Surgical Performance Decayed Among Urologists During COVID-19 Shutdown

    by Balint Der, Daniel Sanford, Ryan Hakim, Erik Vanstrum, Jessica H. Nguyen, Andrew J. Hung

    N/A - Letters to editor format


  • Open Access

    A deep‐learning model using automated performance metrics and clinical features to predict urinary continence recovery after robot‐assisted radical prostatectomy

    by Andrew J. Hung, Jian Chen, Saum Ghodoussipour, Paul J. Oh, Zequn Liu, Jessica Nguyen, Sanjay Purushotham, Inderbir S. Gill, Yan Liu

    Objectives: To predict urinary continence recovery after robot‐assisted radical prostatectomy ( RARP ) using a deep learning ( DL ) model, which was then used to evaluate surgeon's historical patient outcomes. Subjects and Methods: Robotic surgical automated performance metrics ( APM s) during RARP , and patient clinicopathological and continence data were captured prospectively from 100 contemporary RARP s. We used a DL model (DeepSurv) to predict postoperative urinary continence. Model features were ranked based on their importance in prediction. We stratified eight surgeons based on the five top‐ranked features. The top four surgeons were categorized in ‘Group 1/ APM s’, while the remaining four were categorized in ‘Group 2/APMs’. A separate historical cohort of RARP s (January 2015 to August 2016) performed by these two surgeon groups was then used for comparison. Concordance index ( C ‐index) and mean absolute error ( MAE ) were used to measure the model's prediction performance. Outcomes of historical cases were compared using the Kruskal–Wallis, chi‐squared and Fisher's exact tests. Results: Continence was attained in 79 patients (79%) after a median of 126 days. The DL model achieved a C ‐index of 0.6 and an MAE of 85.9 in predicting continence. APM s were ranked higher by the model than clinicopathological features. In the historical cohort, patients in Group 1/ APM s had superior rates of urinary continence at 3 and 6 months postoperatively (47.5 vs 36.7%, P = 0.034, and 68.3 vs 59.2%, P = 0.047, respectively). Conclusion: Using APM s and clinicopathological data, the DeepSurv DL model was able to predict continence after RARP . In this feasibility study, surgeons with more efficient APM s achieved higher continence rates at 3 and 6 months after RARP .