JAJinsu An

Jinsu An

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Jinsu An has a total of 16 co-authors. Here are the top co-authors by number of shared publications:

  • Hyung-Sik Kim

    Department of Mechatronics Engineering, School of ICT Convergence Engineering, College of Science & Technology Konkuk University Chungju‐si Chungcheongbuk‐do Republic of Korea

    5 shared publications
  • Mi-Hyun Choi

    Biomedical Engineering, Research Institute of Biomedical Engineering, School of ICT Convergence Engineering, College of Science and Technology, Konkuk University, Chungju, South Korea

    3 shared publications
  • Soon-Cheol Chung

    Department of Biomedical Engineering, College of Science & Technology, Konkuk University, Chungju-si 27478, Republic of Korea

    3 shared publications
  • Je-Hyeop Lee

    Department of Biomedical Engineering, BK21+ Research Institute of Biomedical Engineering, School of ICT Convergence Engineering, College of Science & Technology, Konkuk University, Chungju 27478, Korea

    2 shared publications
  • Jeong-Han Yi

    Konkuk University

    2 shared publications
  • Ji-Hun Jo

    Department of Biomedical Engineering, BK21+ Research Institute of Biomedical Engineering, School of ICT Convergence Engineering, College of Science & Technology, Konkuk University, Chungju 27478, Korea

    2 shared publications

Latest Publications

  • Open Access

    Development of Multimodal Stimulator for Studying Human Tactile Perception and Cognitive Functions: Preliminary Results

    by Soon-Cheol Chung, Jinsu An, Kyu-Beom Kim, Mi-Hyun Choi, Hyung-Sik Kim

    Humans mostly perceive tactile sensations in daily life as a combination of warmth, vibration, and pressure. To understand the complex tactile perception and cognitive processes, in this study, we aimed to develop a multimodal stimulator and investigate changes in neuronal activity. An actuator that can display warmth (W), vibration (V), and pressure (P) on the distal region of the index finger has been developed. Preliminary experiments were conducted with nine subjects. Electroencephalograms were measured for six tactile stimuli—three single stimuli (W, V, and P) and three combination stimuli (W + V, V + P, and W + V + P)—and event-related desynchronization/synchronization (ERD/S) analysis were performed. The actuator can present all kinds of stimuli in the same location and control stimulation parameters quantitatively. For all experiments, there was an ERD in the α and β bands about 0.5 s after stimulation followed by ERS was observed in the C3 area. The change in the peak-to-peak value was the largest for warmth and the smallest for pressure. In contrast, in the duration of the ERD, W was the shortest and P was the longest. As stimulus presented simultaneously, the ERD became longer in both the alpha and beta bands. In the beta band, the peak of ERD became larger. The developed system was confirmed to be capable of providing valid tactile stimulation, inducing appropriate neuronal activation, and enabling multimodal tactile research.


  • Open Access

    Tissue Ablation Using Irreversible Electrolytic Electroporation with Reduced Voltage

    by Ki-Han Kim, Jinsu An, Young-Jin Park, Jung-Hoon Park, Hong Bae Kim, Jeong-Han Yi, Hyung-Sik Kim

    Thermal tissue ablation may damage surrounding healthy tissue and cause pain. In this study, tissue ablation with the sequential application of electrical energy-inducing irreversible electroporation (IRE) and electrolysis (EL) (IRE + EL = IREEL) was investigated. An IREEL device was designed to control five output pulse parameters: voltage level (VL), pulse width (PW), pulse interval (PI), pulse number (PN), and pulse tail time (PTT). IREEL experiments were conducted on vegetable tissue. The results indicated that by increasing the VL and PTT, the ablation area increased, whereas the impedance was reduced significantly. Almost no ablation area was observed when only EL or IRE at 500 V and 1000 V, respectively, were applied. The ablation area observed with IRE alone at 1500 V was defined as 100%. In the case of IREEL at 500 V and 1000 V, ablation was induced even with the use of micro-second level PTT, and ablation areas of 91% and 186% were achieved, respectively. For IREEL at a voltage of 1500 V, the ablation area expanded to 209% and the maximum temperature was 48.7 °C, whereas the temperature did not exceed 30 °C under other conditions. A change in pH was also observed in an agar-gel phantom experiment which was conducted to examine and confirm whether IREEL induced electrolysis. IREEL was able induce ablation at low voltages owing to the synergistic effect of applying IRE and EL sequentially. Moreover, the ablation areas at high voltages could be increased compared to the areas observed when IRE and EL were applied independently.


  • Open Access

    Determining Obstruction in Endotracheal Tubes Using Physical Respiratory Signals

    by Hyunkyoo Kang, Jin-Kyung Park, Jinsu An, Jeong-Han Yi, Hyung-Sik Kim

    This study proposes a method for determining obstruction of the endotracheal tube (ET) and its degree and location. Respiratory signals were acquired using a three sensor (microphone, pressure, and flow) integrated sensor connector. Obstruction classification involved pre-processing and feature extraction. During pre-processing, one cycle of the respiratory signal was extracted using respiratory cycle extraction and phase segmentation. The signal was then divided into three phases: (i) inspiratory phase, (ii) expiratory phase, and (iii) between both the phases, where the intrapulmonary pressure increased, decreased, and remained constant, respectively. In the feature extraction process, the results were quantified using absolute value average and texture analyses. Artificial ET tubes were fabricated to simulate the presence of foreign substances in the ET tube; they had different degrees of obstruction (0%, 20%, 40%, and 50%) and obstruction positions (Sections 1, 2, and 3). The experiment was performed by connecting the sensor connector and artificial ET tube between the ventilator and test lung. Respiratory signals were obtained in 10 cases by cross connecting the artificial ET tubes. The degree and location of obstruction were classified according to the average absolute value and texture analyses of the flow data. The obstruction can be determined through the texture analysis results using the combined microphone and flow sensor data. The proposed method is simple in configuration, can be readily used in existing setups, and can be operated regardless of surrounding noise.


  • Open Access

    Development of a Tactile Actuator with Non-Contact and Trans-Object Characteristics Using a Time-Varying Magnetic Field

    by Hyung-Sik Kim, Ji-Hun Jo, Je-Hyeop Lee, Jin-Ju Jung, Jin-Su An, Mi-Hyun Choi, Soon-Cheol Chung

    A non-contact tactile stimulation system using a time-varying magnetic field was developed. The system comprises a control unit, power unit, output unit, and actuator. The control unit adjusts stimulation parameters, particularly the signal intensity and frequency. The power unit produces high voltages for generating the magnetic field, whereas the output unit transmits the energy generated according to the signal from the control unit to the actuator. A spiral coil actuator generates the magnetic field. To validate the effectiveness of the system, preliminary experiments on 10 male adults without neurological disorders (23.2 ± 3.05 years) were conducted. Magnetic field stimuli were presented to the right palm of the subjects at three different frequencies (10, 30, and 50 Hz), and corresponding electroencephalogram (EEG) signals were measured simultaneously. Event-related potential (ERP) analysis showed that N100 and P300 components were identified in somatosensory areas. Subjective evaluations revealed that feelings such as “tingling,” “trembling,” “tapping,” and “percussing” were induced. Moreover, as the stimulus frequency changes, differences may occur in induced feeling. The system uses a time-varying magnetic field, which not only induces tactile stimulation without contact but also has trans-object characteristics that can present tactile sensations, even when there is an obstacle between an actuator and skin.


  • Open Access

    Comparison of Neural Activation Area in Primary Somatosensory Cortex and Brodmann Area 3 According to Finger and Phalange High-Frequency Vibration Stimulation

    by Hyung-Sik Kim, Ji-Hun Jo, Je-Hyeop Lee, Jin-Ju Jung, Ki-Han Kim, Jin-Su An, Ye-Jin Kim, Mi-Hyun Choi, Soon-Cheol Chung

    In this study, we measured neuronal activation in the primary somatosensory area (S1) and Brodmann area 3 (BA3) using 3T functional magnetic resonance imaging (fMRI) while presenting a 250-Hz high-frequency vibrational stimulus to each of three phalanges (distal, intermediate, and proximal) of four fingers of the right hand (index, middle, ring, and little). We compared the nerve activation area between each finger and each phalange. Ten healthy male college students (26.6 ± 2.5 years old) participated in this study. One session consisted of three blocks: a rest (30 s), stimulation (30 s), and response phase (9 s). In the rest phase, the vibrational stimulus was not presented. In the stimulation phase, the vibrational stimulation was presented at any one of the three phalanges of the selected finger. In the response phase, subjects were instructed to press a button corresponding to the phalange that they thought had received the vibration. The subtraction method was used to extract the activation area. The activation area in the S1 was the largest when the little finger was stimulated (for the finger comparison), and largest when the second phalange was stimulated (for the phalange comparison). The BA3 showed similar trends, and there was no statistically significant difference.