Yongshun Liu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Yongshun Liu has a total of 42 co-authors. Here are the top co-authors by number of shared publications:
- Yihui Wu
Changchun Institute of Optics, Fine Mechanics and Physics, Chinese Academy of Sciences
5 shared publications - Xin Feng
State Key Laboratory of Applied Optics, Changchun Institute of Optics, Fine Mechanics and Physics, Chinese Academy of Sciences, Changchun 130033, China
3 shared publications - Gaoge Lian
State Key Laboratory of Applied Optics, Changchun Institute of Optics, Fine Mechanics and Physics (CIOMP), Chinese Academy of Sciences, Changchun 130033, China
2 shared publications - Huaming Xing
State Key Laboratory of Applied Optics, Changchun Institute of Optics, Fine Mechanics and Physics (CIOMP), Chinese Academy of Sciences, Changchun 130033, China
2 shared publications - Junhu Zhang
The First Hospital of Jilin University
2 shared publications - Junyu Dong
State Key Laboratory of Applied Optics, Changchun Institute of Optics, Fine Mechanics and Physics, Chinese Academy of Sciences, Changchun 130033, China
2 shared publications
Latest Publications
- Open Access
- 31 July 2023
- Published by MDPI AG in Micromachines
- Vol. 14 (8) , 1548
Double-Glued Multi-Focal Bionic Compound Eye Camera
Compound eye cameras are a vital component of bionics. Compound eye lenses are currently used in light field cameras, monitoring imaging, medical endoscopes, and other fields. However, the resolution of the compound eye lens is still low at the moment, which has an impact on the application scene. Photolithography and negative pressure molding were used to create a double-glued multi-focal bionic compound eye camera in this study. The compound eye camera has 83 microlenses, with ommatidium diameters ranging from 400 μm to 660 μm, and a 92.3 degree field-of-view angle. The double-gluing structure significantly improves the optical performance of the compound eye lens, and the spatial resolution of the ommatidium is 57.00 lp mm−1. Additionally, the measurement of speed is investigated. This double-glue compound eye camera has numerous potential applications in the military, machine vision, and other fields.
- 31 July 2023
- Published by MDPI AG in Micromachines
- Vol. 14 (8) , 1548
Open AccessDouble-Glued Multi-Focal Bionic Compound Eye Camera
Compound eye cameras are a vital component of bionics. Compound eye lenses are currently used in light field cameras, monitoring imaging, medical endoscopes, and other fields. However, the resolution of the compound eye lens is still low at the moment, which has an impact on the application scene. Photolithography and negative pressure molding were used to create a double-glued multi-focal bionic compound eye camera in this study. The compound eye camera has 83 microlenses, with ommatidium diameters ranging from 400 μm to 660 μm, and a 92.3 degree field-of-view angle. The double-gluing structure significantly improves the optical performance of the compound eye lens, and the spatial resolution of the ommatidium is 57.00 lp mm−1. Additionally, the measurement of speed is investigated. This double-glue compound eye camera has numerous potential applications in the military, machine vision, and other fields.
- 1 March 2023
- Published by Elsevier in Acta Biomaterialia
- Vol. 161, 144-153
Hierarchical hydrogel microarrays fabricated based on a microfluidic printing platform for high-throughput screening of stem cell lineage specification
- 1 March 2023
- Published by Elsevier in Acta Biomaterialia
- Vol. 161, 144-153
Hierarchical hydrogel microarrays fabricated based on a microfluidic printing platform for high-throughput screening of stem cell lineage specification
- Open Access
- 10 February 2023
- Published by MDPI AG in Micromachines
- Vol. 14 (2) , 420
A Meniscus Multifocusing Compound Eye Camera Based on Negative Pressure Forming Technology
To meet the challenge of preparing a high-resolution compound eye, this paper proposes a multi-focal-length meniscus compound eye based on MEMS negative pressure molding technology. The aperture is increased, a large field of view angle of 101.14° is obtained, and the ommatidia radius of each stage is gradually increased from 250 μm to 440 μm. A meniscus structure is used to improve the imaging quality of the marginal compound eye so that its resolution can reach 36.00 lp/mm. The prepared microlenses have a uniform shape and a smooth surface, and both panoramic image stitching and moving object tracking are achieved. This technology has great potential for application in many fields, including automatic driving, machine vision, and medical endoscopy.
- 10 February 2023
- Published by MDPI AG in Micromachines
- Vol. 14 (2) , 420
Open AccessA Meniscus Multifocusing Compound Eye Camera Based on Negative Pressure Forming Technology
To meet the challenge of preparing a high-resolution compound eye, this paper proposes a multi-focal-length meniscus compound eye based on MEMS negative pressure molding technology. The aperture is increased, a large field of view angle of 101.14° is obtained, and the ommatidia radius of each stage is gradually increased from 250 μm to 440 μm. A meniscus structure is used to improve the imaging quality of the marginal compound eye so that its resolution can reach 36.00 lp/mm. The prepared microlenses have a uniform shape and a smooth surface, and both panoramic image stitching and moving object tracking are achieved. This technology has great potential for application in many fields, including automatic driving, machine vision, and medical endoscopy.
- Open Access
- 20 October 2022
- Published by Springer Nature in Research Square
High-resolution Meniscus Multi-Focusing Compound Eye by negative pressure forming technology
Aiming at the problem of preparing high-resolution compound eye, this paper proposes a multi-focal length meniscus compound eye based on MEMS negative pressure molding technology. The aperture is increased while the large field angle of view of 101.14° is obtained, and the ommatidia radius of each stage is gradually increased from 250 µm to 440 µm. A meniscus structure is used to improve the imaging quality of the marginal compound eye, so that the resolution of the compound eye can reach 36.00 lp/mm. The prepared microlenses have a uniform shape and a smooth surface, and we realize panoramic image stitching and moving object tracking. The related technologies have great application potential in the fields of automatic driving, machine vision, medical endoscopy, etc.
- 20 October 2022
- Published by Springer Nature in Research Square
Open AccessHigh-resolution Meniscus Multi-Focusing Compound Eye by negative pressure forming technology
Aiming at the problem of preparing high-resolution compound eye, this paper proposes a multi-focal length meniscus compound eye based on MEMS negative pressure molding technology. The aperture is increased while the large field angle of view of 101.14° is obtained, and the ommatidia radius of each stage is gradually increased from 250 µm to 440 µm. A meniscus structure is used to improve the imaging quality of the marginal compound eye, so that the resolution of the compound eye can reach 36.00 lp/mm. The prepared microlenses have a uniform shape and a smooth surface, and we realize panoramic image stitching and moving object tracking. The related technologies have great application potential in the fields of automatic driving, machine vision, medical endoscopy, etc.
- 30 April 2021
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 21 (11) , 2129-2141
Cell-sorting centrifugal microfluidic chip with a flow rectifier
We propose herein a centrifugal microfluidic chip with a flow rectifier that transforms the centrifugal non-steady flow into locally steady flow with continuous flow for size-based cell sorting.
- 30 April 2021
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 21 (11) , 2129-2141
Cell-sorting centrifugal microfluidic chip with a flow rectifier
We propose herein a centrifugal microfluidic chip with a flow rectifier that transforms the centrifugal non-steady flow into locally steady flow with continuous flow for size-based cell sorting.
- Open Access
- 21 March 2021
- Published by MDPI AG in Micromachines
- Vol. 12 (3) , 331
Design and Integration of the Single-Lens Curved Multi-Focusing Compound Eye Camera
Compared with a traditional optical system, the single-lens curved compound eye imaging system has superior optical performance, such as a large field of view (FOV), small size, and high portability. However, defocus and low resolution hinder the further development of single-lens curved compound eye imaging systems. In this study, the design of a nonuniform curved compound eye with multiple focal lengths was used to solve the defocus problem. A two-step gas-assisted process, which was combined with photolithography, soft photolithography, and ultraviolet curing, was proposed for fabricating the ommatidia with a large numerical aperture precisely. Ommatidia with high resolution were fabricated and arranged in five rings. Based on the imaging experimental results, it was demonstrated that the high-resolution and small-volume single-lens curved compound eye imaging system has significant advantages in large-field imaging and rapid recognition.
- 21 March 2021
- Published by MDPI AG in Micromachines
- Vol. 12 (3) , 331
Open AccessDesign and Integration of the Single-Lens Curved Multi-Focusing Compound Eye Camera
Compared with a traditional optical system, the single-lens curved compound eye imaging system has superior optical performance, such as a large field of view (FOV), small size, and high portability. However, defocus and low resolution hinder the further development of single-lens curved compound eye imaging systems. In this study, the design of a nonuniform curved compound eye with multiple focal lengths was used to solve the defocus problem. A two-step gas-assisted process, which was combined with photolithography, soft photolithography, and ultraviolet curing, was proposed for fabricating the ommatidia with a large numerical aperture precisely. Ommatidia with high resolution were fabricated and arranged in five rings. Based on the imaging experimental results, it was demonstrated that the high-resolution and small-volume single-lens curved compound eye imaging system has significant advantages in large-field imaging and rapid recognition.
- Open Access
- 16 September 2020
- Published by MDPI AG in Micromachines
- Vol. 11 (9) , 854
Fabrication and Characterization of Curved Compound Eyes Based on Multifocal Microlenses
Curved compound eyes have generated great interest owing to the wide field of view but the application of devices is hindered for the lack of proper detectors. One-lens curved compound eyes with multi-focal microlenses provide a solution for wide field imaging integrated in a commercial photo-detector. However, it is still a challenge for manufacturing this kind of compound eye. In this paper, a rapid and accurate method is proposed by a combination of photolithography, hot embossing, soft photolithography, and gas-assisted deformation techniques. Microlens arrays with different focal lengths were firstly obtained on a polymer, and then the planar structure was converted to the curved surface. A total of 581 compound eyes with diameters ranging from 152.8 µm to 240.9 µm were successfully obtained on one curved surface within a few hours, and the field of view of the compound eyes exceeded 108°. To verify the characteristics of the fabricated compound eyes, morphology deviation was measured by a probe profile and a scanning electron microscope. The optical performance and imaging capability were also tested and analyzed. As a result, the ommatidia made up of microlenses showed not only high accuracy in morphology, but also imaging uniformity on a focal plane. This flexible massive fabrication of compound eyes indicates great potential for miniaturized imaging systems.
- 16 September 2020
- Published by MDPI AG in Micromachines
- Vol. 11 (9) , 854
Open AccessFabrication and Characterization of Curved Compound Eyes Based on Multifocal Microlenses
Curved compound eyes have generated great interest owing to the wide field of view but the application of devices is hindered for the lack of proper detectors. One-lens curved compound eyes with multi-focal microlenses provide a solution for wide field imaging integrated in a commercial photo-detector. However, it is still a challenge for manufacturing this kind of compound eye. In this paper, a rapid and accurate method is proposed by a combination of photolithography, hot embossing, soft photolithography, and gas-assisted deformation techniques. Microlens arrays with different focal lengths were firstly obtained on a polymer, and then the planar structure was converted to the curved surface. A total of 581 compound eyes with diameters ranging from 152.8 µm to 240.9 µm were successfully obtained on one curved surface within a few hours, and the field of view of the compound eyes exceeded 108°. To verify the characteristics of the fabricated compound eyes, morphology deviation was measured by a probe profile and a scanning electron microscope. The optical performance and imaging capability were also tested and analyzed. As a result, the ommatidia made up of microlenses showed not only high accuracy in morphology, but also imaging uniformity on a focal plane. This flexible massive fabrication of compound eyes indicates great potential for miniaturized imaging systems.
- 3 September 2019
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 19 (20) , 3368-3374
Pressure-controlled microfluidic sub-picoliter ultramicro-volume syringes based on integrated micro-nanostructure arrays
Ultramicro-volume syringes are fabricated in microchannels. The minimum of available droplet volume is in increments as low as 0.5 pL with 96% accuracy. Specifically, controllable synthesis of nanocrystals could be produced in a lab-on-chip platform.
- 3 September 2019
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 19 (20) , 3368-3374
Pressure-controlled microfluidic sub-picoliter ultramicro-volume syringes based on integrated micro-nanostructure arrays
Ultramicro-volume syringes are fabricated in microchannels. The minimum of available droplet volume is in increments as low as 0.5 pL with 96% accuracy. Specifically, controllable synthesis of nanocrystals could be produced in a lab-on-chip platform.
- Open Access
- 1 September 2016
- Published by University of South Florida Libraries in International Journal of Speleology
- Vol. 45 (3) , 219-229
Tube coalescence in the Jingfudong lava tube and implications for lava flow hazard of Tengchong Volcanism
Tube-fed structure occurs as a general phenomenon in Tengchong basic lavas, such as lava tubes, lava plugs and tube-related collapse depressions. We deduced the development of Laoguipo lava flows, which is the longest lava tube (Jingfudong lava tube) evolved in Tengchong volcanic area. Following the detailed documentation of the tube morphology of the Jingfudong lava tube, we propose that the Jingfudong lava tube was formed through vertical coalescence of at least three tubes. The coalescence and bifurcation process are re-constructed by interpretation of tube floor continuity, the distribution of remnant tubes and the scales of lava tube branches (shapes of cross sections). Keywords Tengchong volcanism; Laoguipo volcano; field investigation; lava tube; tube coalescence
- 1 September 2016
- Published by University of South Florida Libraries in International Journal of Speleology
- Vol. 45 (3) , 219-229
Open AccessTube coalescence in the Jingfudong lava tube and implications for lava flow hazard of Tengchong Volcanism
Tube-fed structure occurs as a general phenomenon in Tengchong basic lavas, such as lava tubes, lava plugs and tube-related collapse depressions. We deduced the development of Laoguipo lava flows, which is the longest lava tube (Jingfudong lava tube) evolved in Tengchong volcanic area. Following the detailed documentation of the tube morphology of the Jingfudong lava tube, we propose that the Jingfudong lava tube was formed through vertical coalescence of at least three tubes. The coalescence and bifurcation process are re-constructed by interpretation of tube floor continuity, the distribution of remnant tubes and the scales of lava tube branches (shapes of cross sections). Keywords Tengchong volcanism; Laoguipo volcano; field investigation; lava tube; tube coalescence