ABAida Bustam

Aida Bustam

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Aida Bustam has a total of 41 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • The Safety and Interventions for Redirecting Non‐Urgent Patients From Emergency Departments to Primary Care Services: A Scoping Review

    by Walaa Alsulami, Aidawati Bustam, Adina Abdullah, Jazlan Jamaludin, Siti Nurkamilla Ramdzan

    Background: Emergency departments (EDs) experience overcrowding, resulting in delayed care for life‐threatening conditions, increased healthcare costs, and prolonged waiting times. Non‐urgent patients contribute to ED overcrowding, and redirecting these patients to primary care (PC) is a strategy to reduce pressure on emergency services. However, the safety and procedural components of redirection have not been comprehensively described due to limited evidence. This scoping review aimed to identify the safety outcomes and intervention components associated with redirecting non‐urgent patients from EDs to PC. Methods: Five electronic databases were searched. Eligible studies included non‐urgent patients presenting to EDs who were redirected to PC, reported safety outcomes, and described redirection procedures. Two reviewers independently conducted title and abstract screening and full‐text screening using Rayyan.ai and assessed study quality. Safety outcomes included return visits, hospitalisation, death, and adverse events, which were compared across studies. Redirection procedures were identified using the Innovation domain of the Consolidated Framework for Implementation Research (CFIR). Main Results: Nine studies met the inclusion criteria, including eight observational studies and one randomised controlled trial. The highest reported safety outcomes were a 9.7% return rate, a 1.7% hospitalisation rate, and a 0.07% mortality rate. Most reported components across all studies included documentation of chief complaints, patient registration, measurement of vital signs, and triage. Studies reporting zero hospitalisations and deaths included multiple constructs within the CFIR Innovation domain. Conclusion: Redirecting non‐urgent patients from EDs to PC appears safe and acceptable when clear criteria are implemented; however, evidence remains limited.

  • Predicting plasma leakage in adult patients with dengue using clinical and laboratory markers at the time of emergency department presentation

    by Yung Ban Cheng, Aida Bustam, Khadijah Poh, Muhaimin Noor Azhar, Mohd Hafyzuddin Md Yusuf

    Plasma leakage is a key pathophysiological feature of severe dengue and typically precedes clinical deterioration. However, current diagnostic criteria rely on warning signs that often appear after leakage has begun. To identify early clinical and laboratory predictors of ultrasound-confirmed plasma leakage in adult dengue patients and evaluate their association with adverse clinical outcomes. A retrospective cohort study of 507 adult patients with laboratory-confirmed dengue admitted to a tertiary Malaysian hospital between January 2022 and December 2023. Plasma leakage was defined by third-space fluid accumulation detected on point-of-care ultrasound. Multivariate logistic regression identified independent predictors from demographic, clinical, and laboratory variables measured at presentation. Ninety-nine patients (19.5%) developed plasma leakage. Independent predictors included older age (OR 1.042, 95% CI: 1.013-1.071), higher BMI (OR 1.615, 95% CI: 1.255-2.079), smoking (OR 2.955, 95% CI: 1.217-7.176), mucosal bleeding (OR 5.994, 95% CI: 1.152-31.185), elevated haematocrit (OR 1.613, 95% CI: 1.271-2.046), raised AST (OR 1.022, 95% CI: 1.011-1.033), low albumin (OR 0.850, 95% CI: 0.748-0.966), and elevated lactate (OR 29.668, 95% CI: 12.020-73.229). A lactate cut-off of ≥1.45 mmol/L yielded 96.0% sensitivity and 98.3% negative predictive value. These predictors were significantly associated with ICU admission, severe dengue, and prolonged hospital stay. These findings support the use of objective, readily available markers to guide emergency department triage and decision-making where imaging is limited. The association between smoking and plasma leakage is a novel finding warranting further investigation.

  • Open Access

    Correlation between venous excess ultrasound and acute kidney injury in patients with sepsis: A pilot study

    by Muhamed Hanizar Hajanajumudin, Muhaimin Noor Azhar, Aida Bustam, Aliyah Zambri, Khadijah Poh

    OBJECTIVES: Venous congestion is increasingly recognized as a contributor to acute kidney injury (AKI) in critically ill patients. The venous excess ultrasound (VExUS) score has been proposed to assess systemic venous congestion, but its role in emergency department (ED) sepsis remains underexplored. This pilot study investigated the association between VExUS scores, development of AKI, and other outcomes in septic ED patients. METHODS: This was a prospective observational pilot study conducted from July 2023 to December 2023 in a university-affiliated tertiary ED. Adult patients with sepsis and an inferior vena cava diameter ≥2 cm after initial resuscitation were enrolled. VExUS was assessed at enrolment. The primary outcome was AKI within 72 h based on the Kidney Disease Improving Global Outcomes criteria. Secondary outcomes included mortality, organ dysfunction scores, and other outcomes. Associations were analyzed using Kendall’s tau-b correlation and group comparisons with Mann–Whitney U -test. RESULTS: Thirty-one patients were included, mean age 64.2 years. VExUS scores were Grade 1 in 64.5%, Grade 2 in 25.8%, and Grade 3 in 9.7%. Median VExUS scores did not differ between patients with and without AKI (2.0 [2.0–3.0] vs. 2.0 [2.0–3.0], P = 0.729), died and survived at 28 days (2.0 [2.0–2.25] vs. 2.0 [2.0–3.0], P = 0.419) or 60 days (2.0 [2.0–3.0] vs. 2.0 [2.0–3.0], P = 0.693). VExUS showed moderate correlations with creatinine (τ = 0.392, P = 0.004), sequential organ failure assessment (τ =0.267, P = 0.041), and inotrope requirements (τ = 0.299, P = 0.041). CONCLUSION: In septic ED patients, VExUS was not associated with AKI or mortality but correlated with markers of organ dysfunction.


  • Utility of the neutrophil-to-lymphocyte ratio in predicting plasma leakage amongst adults with dengue fever

    by Cheng Yung Ban, Aida Bustam, Muhaimin Noor Azhar, Khadijah Poh

    Plasma leakage is a hallmark of severe dengue and a major contributor to morbidity and mortality, yet early identification remains difficult, particularly in resource-limited settings. This single-centre retrospective study evaluated the diagnostic accuracy of the neutrophil-to-lymphocyte ratio (NLR) in predicting plasma leakage amongst 507 adults with laboratory-confirmed dengue admitted between January 2022 and December 2023. Plasma leakage was defined sonographically. We assessed NLR trends from illness days 1 to 11 and constructed a bivariate plot of absolute neutrophil and lymphocyte counts to visualise immune dynamics. Ninety-nine patients (19.5%) developed plasma leakage. NLR values differed significantly between groups on days 2–8. Admission NLR showed modest performance (AUROC 0.626), with high sensitivity (87.9%) but low specificity (33.8%). The highest accuracy occurred on day 2 (AUROC 0.923). Whilst NLR alone is insufficient as a diagnostic tool, early phase measurements and visual frameworks of immune cell trajectories may enhance risk stratification for plasma leakage in dengue. Graphical Abstract


  • Development and Validation of the Dengue Simplified Severity Score Based on the Marois Severity Score for Predicting Severe Dengue in the Emergency Department

    by Kaur Dhesi Preetvinder, Khadijah Poh, Aida Bustam, Aliyah Zambri, Muhaimin Noor Azhar

    Objective: To validate and simplify Marois Severity Score (MSS) for improved usability in the emergency department (ED) setting, and to compare its predictive accuracy with a newly developed Dengue Simplified Severity Score (D‐SSS). Methods: This retrospective, observational study included adult patients presenting with laboratory‐confirmed dengue to Universiti Malaya Medical Centre ED from January 2023 to December 2023. D‐SSS was developed by modifying MSS. The scoring system incorporated age, hypertension, mucosal bleeding, thrombocytopenia, and elevated ALT levels. D‐SSS and MSS were evaluated for accuracy in predicting severe dengue according to the World Health Organisation 2009 classification using receiver operating characteristic (ROC) analysis. Results: Of 507 eligible patients, 350 were analysed. D‐SSS, with a cut‐off value of 2.5, demonstrated 80.0% (95% CI: 51.91, 95.67) sensitivity and 75.5% (95% CI: 70.55, 80.03) specificity in predicting severe dengue. Its discriminative ability (AUC: 0.856) was numerically higher but not statistically different from MSS (AUC: 0.782; p = 0.335, DeLong's test). Conclusions: D‐SSS provides an accurate and more practical tool for predicting severe dengue in the ED. Its simplified design enhances applicability, facilitating earlier intervention and potentially improving patient outcomes.


  • Open Access

    Correlation of UCH-L1 and GFAP in predicting severity of traumatic brain injury in an Asian population

    by Khadijah Poh, Rozaida Poh Yuen Ying, Suzita Mohd Noor, Aida Bustam, Anwar Norazit, Aliyah Zambri, Muhaimin Noor Azhar

    The application of biomarkers in TBI management remains underutilised with paucity of data in Asian populations. This study investigated the correlation between UCH-L1 and GFAP with TBI severity and patient outcomes in a Malaysian tertiary centre. The study was conducted at Universiti Malaya Medical Centre in Kuala Lumpur, Malaysia, from February 1, 2017, to November 30, 2019. GFAP and UCH-L1 were measured in 61 TBI cases and 19 controls. Correlations between biomarkers and TBI severity, as well as patient outcomes, were assessed using Spearman's rank correlation coefficient. GFAP/UCHL1 showed significant correlation with Marshall CT classification (r=0.437, p<0.001), Glasgow Coma Scale on arrival (r=-0.444, p<0.001), and Acute Physiology and Chronic Health Evaluation II (APACHEII) score (r=0.501, p<0.001). GFAP demonstrated fair-to-good accuracy in predicting TBI severity and outcomes. A consistent cut-off value of 0.01845 ng/mL for GFAP and 0.01960 for GFAP/UCHL1 predicted TBI severity, with high sensitivity (72.2-100%) and acceptable specificity (38.8-80.0%). GFAP and GFAP/UCHL1 showed promising utility in predicting TBI severity and patient outcomes in the Asian population. The findings underscore the potential clinical significance of biomarker assessment in TBI management, though further validation in larger cohorts is warranted.

  • Open Access

    Accuracy of smartphone camera urine photo colorimetry as indicators of dehydration

    by Aida Bustam, Khadijah Poh, Siew Shuin Soo, Fathmath Sausan Naseem, Mohd Hafyzuddin Md Yusuf, Naseeha Ubaidi Hishamudin, Muhaimin Noor Azhar

    Objective: Direct urine color assessment has been shown to correlate with hydration status. However, this method is subject to inter- and intra-observer variability. Digital image colorimetry provides a more objective method. This study evaluated the diagnostic accuracy of urine photo colorimetry using different smartphones under different lighting conditions, and determined the optimal cut-off value to predict clinical dehydration. Methods: The urine samples were photographed in a customized photo box, under five simulated lighting conditions, using five smartphones. The images were analyzed using Adobe Photoshop to obtain Red, Green, and Blue (RGB) values. The correlation between RGB values and urine laboratory parameters were determined. The optimal cut-off value to predict dehydration was determined using area under the receiver operating characteristic curve. Results: A total of 56 patients were included in the data analysis. Images captured using five different smartphones under five lighting conditions produced a dataset of 1400 images. The study found a statistically significant correlation between Blue and Green values with urine osmolality, sodium, urine specific gravity, protein, and ketones. The diagnostic accuracy of the Blue value for predicting dehydration were “good” to “excellent” across all phones under all lighting conditions with sensitivity >90% at cut-off Blue value of 170. Conclusions: Smartphone-based urine colorimetry is a highly sensitive tool in predicting dehydration.


  • Open Access

    Improving the reliability of smartphone-based urine colorimetry using a colour card calibration method

    by Muhaimin Noor Azhar, Aida Bustam, Fathmath Sausan Naseem, Soo Siew Shuin, Mohd Hafyzuddin Md Yusuf, Naseeha Ubaidi Hishamudin, Khadijah Poh

    Objective: Urine colorimetry using a digital image–based colorimetry is potentially an accessible hydration assessment method. This study evaluated the agreement between urine colorimetry values measured with different smartphone brands under various lighting conditions in patients with dengue fever. Methods: The urine samples were photographed in a customized photo box, under five simulated lighting conditions, using five smartphones. These images were analyzed using Adobe Photoshop to obtain urine Red, Green and Blue (RGB) values with and without colour correction. A commercially available colour calibration card was used for colour correction. Using intraclass correlation coefficient (ICC), inter-phone and intra-phone agreements of urine RGB values were analyzed. Results: Without colour correction, the various smartphones produced the highest agreement for Blue and Green values under the ‘daylight’ lighting condition. With colour correction, ICC values showed ‘exceptional’ inter-phone and intra-phone agreement for the Blue and Green values (ICC > 0.9). Red values showed ‘poor’ (ICC < 0.5) agreement with and without colour correction in all lighting conditions. Out of the five phones compared in this study, Phone 4 produced the lowest intra-phone agreement. Conclusions: Colour calibration using photo colour cards improved the reliability of smartphone-based urine colorimetry, making this a promising point-of-care hydration assessment tool using the ubiquitous smartphone.


  • Non-rebreather mask and low-flow nasal cannula vs high-flow nasal cannula in severe COVID−19 pneumonia in the emergency department

    by Muhammad Khidir Mohd Kamil, Khadijah Poh Yuen Yoong, Abdul Muhaimin Noor Azhar, Aida Bustam, Ahmad Hariz Abdullah, Mohd Hafyzuddin Md Yusuf, Aliyah Zambri, Ahmad Zulkarnain Ahmad Zahedi, Hidayah Shafie


  • Open Access

    COVID-19 aerosol box as protection from droplet and aerosol contaminations in healthcare workers performing airway intubation: a randomised cross-over simulation study

    by Muhaimin Noor Azhar, Aida Bustam, Khadijah Poh, Ahmad Zulkarnain Ahmad Zahedi, Mohd Zahir Amin Mohd Nazri, Mohammad Aizuddin Azizah Ariffin, Mohd Hafyzuddin Md Yusuf, Aliyah Zambri, Johnathan Y O Chong, Anhar Kamarudin, et al.

    Background Concerns over high transmission risk of SARS-CoV-2 have led to innovation and usage of an aerosol box to protect healthcare workers during airway intubation in patients with COVID-19. Its efficacy as a barrier protection in addition to the use of a standard personal protective equipment (PPE) is not fully known. We performed a simulated study to investigate the relationship between aerosol box usage during intubation and contaminations on healthcare workers pre-doffing and post-doffing of PPE. Methods This was a randomised cross-over study conducted between 9 April to 5 May 2020 in the ED of University Malaya Medical Centre. Postgraduate Emergency Medicine trainees performed video laryngoscope-assisted intubation on an airway manikin with and without an aerosol box in a random order. Contamination was simulated by nebulised Glo Germ. Primary outcome was number of contaminated front and back body regions pre-doffing and post-doffing of PPE of the intubator and assistant. Secondary outcomes were intubation time, Cormack-Lehane score, number of intubation attempts and participants’ feedback. Results Thirty-six trainees completed the study interventions. The number of contaminated front and back body regions pre-doffing of PPE was significantly higher without the aerosol box (all p valuesConclusions An aerosol box may significantly reduce exposure to contaminations but with increased intubation time and reduced operator’s mobility and visibility. Furthermore, the difference in degree of contamination between using and not using an aerosol box could be offset by proper doffing of PPE.