Hong Jiang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Hong Jiang has a total of 559 co-authors. Here are the top co-authors by number of shared publications:
Liping Zhou
50 shared publications- Lilei Yu
Wuhan University
47 shared publications Xiaoya Zhou
41 shared publicationsBing Huang
Department of Cardiology, Renmin Hospital of Wuhan University , Wuhan
39 shared publicationsSongyun Wang
39 shared publicationsZhuo Wang
34 shared publications
Latest Publications
- Open Access
- 3 November 2026
- Published by MDPI AG in Biomedicines
- Vol. 14 (11) , 2533
CCL4 Enhances Left Stellate Ganglion Sympathetic Activity and Aggravates Ventricular Arrhythmias After Myocardial Ischemia Reperfusion
Background: Excessive left stellate ganglion (LSG) activity contributes to ventricular arrhythmias (VAs) after myocardial ischemia reperfusion (I/R). C-C motif chemokine ligand 4 (CCL4) is an inflammatory chemokine involved in neuroimmune signaling. However, whether CCL4 contributes to LSG activation and VAs after myocardial I/R remains unclear. Methods: We enrolled 98 patients with acute myocardial infarction undergoing emergency percutaneous coronary intervention (PCI) and assessed circulating CCL4, norepinephrine (NE), heart rate variability, and 24-h VAs. In beagles, CCL4 or CCL4 plus a neutralizing antibody was locally microinjected into the LSG before myocardial I/R. LSG neural activity and function, myocardial sympathetic and inflammatory indices, ventricular electrophysiology, and VAs were evaluated. C-C chemokine receptor type 5 (CCR5) expression and localization, together with local immune inflammatory changes, were assessed within the LSG. Results: Patients who developed VAs during post-PCI monitoring had higher circulating CCL4 levels both before PCI and at 1 h after PCI reperfusion, and the increase in CCL4 from pre-PCI to 1 h post-PCI was significantly greater. CCL4 at 1 h post-PCI correlated with sympathetic-related indices and 24-h ventricular premature beat burden, and remained independently associated with VAs after multivariable adjustment. In beagles, myocardial I/R increased endogenous CCL4 mRNA expression in the LSG. Local CCL4 administration enhanced LSG neural activity and function, increased myocardial TH-positive area and pro-inflammatory cytokine mRNA expression, shortened effective refractory period and action potential duration at 90% repolarization, and promoted VAs, whereas CCL4 neutralization attenuated these effects. CCR5 partially colocalized with tyrosine hydroxylase-positive sympathetic neurons. CCR5 expression and c-Fos activation were increased after I/R and further enhanced by CCL4. CCL4 also increased the numbers of Iba1-, CD3-, and CD11c-positive cells and inflammatory responses within the LSG. Conclusions: Clinically, circulating CCL4 was associated with VAs after PCI. In the canine I/R model, local CCL4 administration enhanced LSG sympathetic activity and ventricular arrhythmia susceptibility, potentially involving CCR5-related and local inflammatory processes.
- 3 November 2026
- Published by MDPI AG in Biomedicines
- Vol. 14 (11) , 2533
Open AccessCCL4 Enhances Left Stellate Ganglion Sympathetic Activity and Aggravates Ventricular Arrhythmias After Myocardial Ischemia Reperfusion
Background: Excessive left stellate ganglion (LSG) activity contributes to ventricular arrhythmias (VAs) after myocardial ischemia reperfusion (I/R). C-C motif chemokine ligand 4 (CCL4) is an inflammatory chemokine involved in neuroimmune signaling. However, whether CCL4 contributes to LSG activation and VAs after myocardial I/R remains unclear. Methods: We enrolled 98 patients with acute myocardial infarction undergoing emergency percutaneous coronary intervention (PCI) and assessed circulating CCL4, norepinephrine (NE), heart rate variability, and 24-h VAs. In beagles, CCL4 or CCL4 plus a neutralizing antibody was locally microinjected into the LSG before myocardial I/R. LSG neural activity and function, myocardial sympathetic and inflammatory indices, ventricular electrophysiology, and VAs were evaluated. C-C chemokine receptor type 5 (CCR5) expression and localization, together with local immune inflammatory changes, were assessed within the LSG. Results: Patients who developed VAs during post-PCI monitoring had higher circulating CCL4 levels both before PCI and at 1 h after PCI reperfusion, and the increase in CCL4 from pre-PCI to 1 h post-PCI was significantly greater. CCL4 at 1 h post-PCI correlated with sympathetic-related indices and 24-h ventricular premature beat burden, and remained independently associated with VAs after multivariable adjustment. In beagles, myocardial I/R increased endogenous CCL4 mRNA expression in the LSG. Local CCL4 administration enhanced LSG neural activity and function, increased myocardial TH-positive area and pro-inflammatory cytokine mRNA expression, shortened effective refractory period and action potential duration at 90% repolarization, and promoted VAs, whereas CCL4 neutralization attenuated these effects. CCR5 partially colocalized with tyrosine hydroxylase-positive sympathetic neurons. CCR5 expression and c-Fos activation were increased after I/R and further enhanced by CCL4. CCL4 also increased the numbers of Iba1-, CD3-, and CD11c-positive cells and inflammatory responses within the LSG. Conclusions: Clinically, circulating CCL4 was associated with VAs after PCI. In the canine I/R model, local CCL4 administration enhanced LSG sympathetic activity and ventricular arrhythmia susceptibility, potentially involving CCR5-related and local inflammatory processes.
- Open Access
- 30 October 2026
- Published by Elsevier in JACC: Asia
Low-Intensity Focused Ultrasound Modulation of Stellate Ganglion Attenuates Post-STEMI Ventricular Arrhythmias
- 30 October 2026
- Published by Elsevier in JACC: Asia
Open AccessLow-Intensity Focused Ultrasound Modulation of Stellate Ganglion Attenuates Post-STEMI Ventricular Arrhythmias
- 26 March 2026
- Published by Elsevier in JACC: Cardiovascular Interventions
- Vol. 19 (8) , 943-957
Drug-Coated Balloon Angioplasty vs Drug-Eluting Stents in Noncomplex Coronary Bifurcation Lesions
- 26 March 2026
- Published by Elsevier in JACC: Cardiovascular Interventions
- Vol. 19 (8) , 943-957
Drug-Coated Balloon Angioplasty vs Drug-Eluting Stents in Noncomplex Coronary Bifurcation Lesions
- Open Access
- 24 February 2026
- Published by Elsevier in Materials Today Bio
- Vol. 37, 102952
Ultrasound-activated dual-targeted liposomes for visualized precise neuromodulation against myocardial ischemia-reperfusion injury
- 24 February 2026
- Published by Elsevier in Materials Today Bio
- Vol. 37, 102952
Open AccessUltrasound-activated dual-targeted liposomes for visualized precise neuromodulation against myocardial ischemia-reperfusion injury
- Open Access
- 18 February 2026
- Published by Frontiers Media SA in Frontiers in Physiology
- Vol. 16, 1702254
Asmeton minimizes dry cough and diaphragmatic contraction during pulsed-field ablation of atrial fibrillation: a clinical prospective randomized study
Purpose: Pulsed-field ablation (PFA) is a novel ablation modality with promising outcomes for atrial fibrillation therapy. However, PFA might lead to dry cough and diaphragmatic contraction, especially under conscious sedation. We aim to explore a novel approach to reduce dry cough and diaphragmatic contraction during PFA procedures performed under conscious sedation. Methods: A total of 16 patients who underwent PFA pulmonary vein isolation under conscious sedation were divided into the asmeton (with preprocedure asmeton) and control groups. A scoring system was developed to assess dry cough and diaphragmatic contraction. Results: A total of 608 ablations and 893 ablations were performed in the control and asmeton groups, respectively. The dry cough score ( P = 0.045) in all pulmonary veins was significantly reduced by 73.1% in the asmeton group in comparison with the control group. The proportion of medium-to-high dry cough incidences decreased from 12.2 ± 10.4% in the control group to 1.8 ± 3.7% in the asmeton group ( P = 0.027). The diaphragmatic contraction score in the asmeton group was 37.5% lower than that in the control group, and the proportion of severe diaphragmatic contraction incidences was significantly reduced from 2.8 ± 8.4% in the control group to 0.0 ± 0.0% in the asmeton group ( P = 0.006). Conclusion: Asmeton might eliminate moderate-to-severe dry cough and reduce the severity of diaphragmatic contraction during pulmonary vein isolation under conscious sedation ablation.
- 18 February 2026
- Published by Frontiers Media SA in Frontiers in Physiology
- Vol. 16, 1702254
Open AccessAsmeton minimizes dry cough and diaphragmatic contraction during pulsed-field ablation of atrial fibrillation: a clinical prospective randomized study
Purpose: Pulsed-field ablation (PFA) is a novel ablation modality with promising outcomes for atrial fibrillation therapy. However, PFA might lead to dry cough and diaphragmatic contraction, especially under conscious sedation. We aim to explore a novel approach to reduce dry cough and diaphragmatic contraction during PFA procedures performed under conscious sedation. Methods: A total of 16 patients who underwent PFA pulmonary vein isolation under conscious sedation were divided into the asmeton (with preprocedure asmeton) and control groups. A scoring system was developed to assess dry cough and diaphragmatic contraction. Results: A total of 608 ablations and 893 ablations were performed in the control and asmeton groups, respectively. The dry cough score ( P = 0.045) in all pulmonary veins was significantly reduced by 73.1% in the asmeton group in comparison with the control group. The proportion of medium-to-high dry cough incidences decreased from 12.2 ± 10.4% in the control group to 1.8 ± 3.7% in the asmeton group ( P = 0.027). The diaphragmatic contraction score in the asmeton group was 37.5% lower than that in the control group, and the proportion of severe diaphragmatic contraction incidences was significantly reduced from 2.8 ± 8.4% in the control group to 0.0 ± 0.0% in the asmeton group ( P = 0.006). Conclusion: Asmeton might eliminate moderate-to-severe dry cough and reduce the severity of diaphragmatic contraction during pulmonary vein isolation under conscious sedation ablation.
- 6 October 2025
- Published by Wiley in Catheterization and Cardiovascular Interventions
- Vol. 106 (7) , 3574-3582
One‐Year Outcomes of Novel Transcatheter Edge‐to‐Edge Mitral Repair System in Patients With Functional Mitral Regurgitation
Background: Transcatheter edge‐to‐edge repair (TEER) improves outcomes in patients with heart failure and moderate‐to‐severe functional mitral regurgitation (FMR) who remain symptomatic despite the use of maximal doses of guideline‐directed medical therapy (GDMT). The SQ‐Kyrin‐M system is a novel TEER device designed for FMR treatment. Aims: This multicenter, prospective, single‐arm study (ClinicalTrials.gov number: NCT05988450) evaluates the safety and efficacy of the SQ‐Kyrin‐M system in severe symptomatic FMR. Methods: A total of 125 eligible patients (mean age 65.5 ± 8.1 years) with heart failure and moderate‐to‐severe or severe FMR who remained symptomatic despite the use of maximal doses of GDMT were involved in the analysis. The primary endpoint was the composite rate of all‐cause mortality and heart failure hospitalization at 1 year post‐intervention. Independent assessments were conducted by an echocardiography core laboratory (ECL) and a clinical events committee (CEC). Results: At 1 year, the primary endpoint rate was 16.0% (20/125), and the composite major adverse event rate was 10.4%. Mitral regurgitation was reduced to ≤ 2+ in 94.2% of patients, with significant left ventricular reverse remodeling (LVEDV reduction: 33.8 ± 55.4 mL, p < 0.001). Patient‐reported outcomes improved significantly, with Kansas City Cardiomyopathy Questionnaire (KCCQ) scores increasing by 15.9 ± 18.8 points ( p < 0.001) and 6‐minute walk distance (6MWD) improving by 46.7 ± 90.7 m ( p < 0.001). The proportion of patients in New York Heart Association (NYHA) class I/II increased from 30.4% to 84.4% ( p < 0.001). Conclusions: The SQ‐Kyrin‐M transcatheter mitral valve repair system bolsters the evidence supporting the safety and efficacy of TEER interventions for FMR patients.
- 6 October 2025
- Published by Wiley in Catheterization and Cardiovascular Interventions
- Vol. 106 (7) , 3574-3582
One‐Year Outcomes of Novel Transcatheter Edge‐to‐Edge Mitral Repair System in Patients With Functional Mitral Regurgitation
Background: Transcatheter edge‐to‐edge repair (TEER) improves outcomes in patients with heart failure and moderate‐to‐severe functional mitral regurgitation (FMR) who remain symptomatic despite the use of maximal doses of guideline‐directed medical therapy (GDMT). The SQ‐Kyrin‐M system is a novel TEER device designed for FMR treatment. Aims: This multicenter, prospective, single‐arm study (ClinicalTrials.gov number: NCT05988450) evaluates the safety and efficacy of the SQ‐Kyrin‐M system in severe symptomatic FMR. Methods: A total of 125 eligible patients (mean age 65.5 ± 8.1 years) with heart failure and moderate‐to‐severe or severe FMR who remained symptomatic despite the use of maximal doses of GDMT were involved in the analysis. The primary endpoint was the composite rate of all‐cause mortality and heart failure hospitalization at 1 year post‐intervention. Independent assessments were conducted by an echocardiography core laboratory (ECL) and a clinical events committee (CEC). Results: At 1 year, the primary endpoint rate was 16.0% (20/125), and the composite major adverse event rate was 10.4%. Mitral regurgitation was reduced to ≤ 2+ in 94.2% of patients, with significant left ventricular reverse remodeling (LVEDV reduction: 33.8 ± 55.4 mL, p < 0.001). Patient‐reported outcomes improved significantly, with Kansas City Cardiomyopathy Questionnaire (KCCQ) scores increasing by 15.9 ± 18.8 points ( p < 0.001) and 6‐minute walk distance (6MWD) improving by 46.7 ± 90.7 m ( p < 0.001). The proportion of patients in New York Heart Association (NYHA) class I/II increased from 30.4% to 84.4% ( p < 0.001). Conclusions: The SQ‐Kyrin‐M transcatheter mitral valve repair system bolsters the evidence supporting the safety and efficacy of TEER interventions for FMR patients.
- Open Access
- 21 August 2025
- Published by Elsevier in Ultrasonics Sonochemistry
- Vol. 121, 107524
Ultrasound-responsive diagnostic and therapeutic micro-/nanoplatforms for biomedical applications and clinical translation
- 21 August 2025
- Published by Elsevier in Ultrasonics Sonochemistry
- Vol. 121, 107524
Open AccessUltrasound-responsive diagnostic and therapeutic micro-/nanoplatforms for biomedical applications and clinical translation
- Top Cited PapersOpen Access
- 2 August 2025
- Published by Springer Nature in Nature Communications
- Vol. 16 (1) , 1-11
KNN-based frequency-adjustable ferroelectric heterojunction and biomedical applications
High-performance lead-free K0.5Na0.5NbO3 piezoelectric ceramics present a practical alternative to lead-containing counterparts by effectively reducing potential environmental hazards. This advancement is particularly relevant to the development of ferroelectric heterojunction devices for biomedical applications. Here, we design and fabricate a frequency-adjustable ferroelectric heterojunction based on the developed K0.5Na0.5NbO3 piezoelectric ceramics with a high piezoelectric coefficient (d 33 = 680 pC/N). By leveraging flexible encapsulation, the heterojunction achieves miniaturization (φ = 13.3 mm, h = 2.28 mm) and suitability for implantation. After penetrating the rat skull, the ultrasound generated by the heterojunction at a frequency of 3 MHz reaches a focal depth of about 7.9 mm, a focal width of approximately 480 μm at −6 dB, and millimeter-scale continuous focal tuning (1.5 mm) within a narrow frequency range (2.7–3.3 MHz). Additionally, the implanted heterojunction enables long-term and high-precision transcranial neuromodulation, and consequently yields therapeutic effects in a myocardial infarction animal model. Collectively, this study highlights a viable strategy for developing and applying lead-free ferroelectric heterojunctions, expanding their potential in brain modulation, and providing new insights into clinical treatments of myocardial infarction.
- 2 August 2025
- Published by Springer Nature in Nature Communications
- Vol. 16 (1) , 1-11
Top Cited PapersOpen AccessKNN-based frequency-adjustable ferroelectric heterojunction and biomedical applications
High-performance lead-free K0.5Na0.5NbO3 piezoelectric ceramics present a practical alternative to lead-containing counterparts by effectively reducing potential environmental hazards. This advancement is particularly relevant to the development of ferroelectric heterojunction devices for biomedical applications. Here, we design and fabricate a frequency-adjustable ferroelectric heterojunction based on the developed K0.5Na0.5NbO3 piezoelectric ceramics with a high piezoelectric coefficient (d 33 = 680 pC/N). By leveraging flexible encapsulation, the heterojunction achieves miniaturization (φ = 13.3 mm, h = 2.28 mm) and suitability for implantation. After penetrating the rat skull, the ultrasound generated by the heterojunction at a frequency of 3 MHz reaches a focal depth of about 7.9 mm, a focal width of approximately 480 μm at −6 dB, and millimeter-scale continuous focal tuning (1.5 mm) within a narrow frequency range (2.7–3.3 MHz). Additionally, the implanted heterojunction enables long-term and high-precision transcranial neuromodulation, and consequently yields therapeutic effects in a myocardial infarction animal model. Collectively, this study highlights a viable strategy for developing and applying lead-free ferroelectric heterojunctions, expanding their potential in brain modulation, and providing new insights into clinical treatments of myocardial infarction.