Kirsty A. Paton
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Kirsty A. Paton has a total of 115 co-authors. Here are the top co-authors by number of shared publications:
- Julian Heymes
Paul Scherrer Institut, Forschungsstrasse 111, 5232 Villigen, Switzerland
7 shared publications - Patrick Sieberer
Paul Scherrer Institut, Forschungsstrasse 111, 5232 Villigen, Switzerland
7 shared publications - Anna Bergamaschi
Paul Scherrer Institute
6 shared publications - Dominic Greiffenberg
Paul Scherrer Institut, Forschungsstrasse 111, 5232 Villigen, Switzerland
6 shared publications - Erik Fröjdh
PSI Center for Photon Science, Paul Scherrer Institut, Forschungsstrasse 111, 5232 Villigen PSI, Switzerland
6 shared publications - Xiangyu Xie
University of Science and Technology of China
6 shared publications
Latest Publications
- Open Access
- 1 December 2025
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 20 (12) , C12007
A 1 Megapixel charge integrating hybrid pixel detector for electron diffraction
Electrons have emerged as an important complement to X-rays in crystallography, particularly for compounds that present challenges in growing crystals sufficiently large for synchrotron radiation (5–10 µm) or laboratory diffractometers (∼50 µm). Given the nature of electron-matter interactions, electron diffraction (ED) provides a way to experimentally determine the electrostatic potential of compounds. To fully harness the power of ED, we have integrated a fast, low-noise and radiation-hard 1 Megapixel JUNGFRAU detector with a modern JEOL transmission electron microscope (TEM). JUNGFRAU is a charge-integrating hybrid pixel detector, with a dynamic range of 120 MeV/pixel/frame and a maximum frame rate of 2.2 kHz in continuous mode. It can detect up to 1.3 million 200 keV electrons per pixel per second before saturation. To handle the resulting 5 GB/s raw data stream (fiberoptic; 4×10 Gbps), our system features an FPGA-based backend, Jungfraujoch , which converts raw ADC values into deposited energy and enables on-the-fly frame summation. Additionally, we developed a software package with an intuitive graphical user interface that integrates detector and microscope control. This solution provides partly automated data acquisition and post-processing, with data stored in compressed HDF5 files with comprehensive metadata. This work assesses the performance of JUNGFRAU across multiple electron energies by analyzing energy deposition and pixel spread. The complete data pipeline — from detector to user interface — is validated through an ED experiment yielding structural insights.
- 1 December 2025
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 20 (12) , C12007
Open AccessA 1 Megapixel charge integrating hybrid pixel detector for electron diffraction
Electrons have emerged as an important complement to X-rays in crystallography, particularly for compounds that present challenges in growing crystals sufficiently large for synchrotron radiation (5–10 µm) or laboratory diffractometers (∼50 µm). Given the nature of electron-matter interactions, electron diffraction (ED) provides a way to experimentally determine the electrostatic potential of compounds. To fully harness the power of ED, we have integrated a fast, low-noise and radiation-hard 1 Megapixel JUNGFRAU detector with a modern JEOL transmission electron microscope (TEM). JUNGFRAU is a charge-integrating hybrid pixel detector, with a dynamic range of 120 MeV/pixel/frame and a maximum frame rate of 2.2 kHz in continuous mode. It can detect up to 1.3 million 200 keV electrons per pixel per second before saturation. To handle the resulting 5 GB/s raw data stream (fiberoptic; 4×10 Gbps), our system features an FPGA-based backend, Jungfraujoch , which converts raw ADC values into deposited energy and enables on-the-fly frame summation. Additionally, we developed a software package with an intuitive graphical user interface that integrates detector and microscope control. This solution provides partly automated data acquisition and post-processing, with data stored in compressed HDF5 files with comprehensive metadata. This work assesses the performance of JUNGFRAU across multiple electron energies by analyzing energy deposition and pixel spread. The complete data pipeline — from detector to user interface — is validated through an ED experiment yielding structural insights.
- Open Access
- 29 July 2025
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 1081
Optimization and validation of charge transport simulation for hybrid pixel detectors incorporating the repulsion effect
- 29 July 2025
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 1081
Open AccessOptimization and validation of charge transport simulation for hybrid pixel detectors incorporating the repulsion effect
- Open Access
- 10 June 2025
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 1080
First results of the ADC-SAR-05 prototype towards On-chip digitization of the JUNGFRAU charge-integrating X-ray pixel detector
- 10 June 2025
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 1080
Open AccessFirst results of the ADC-SAR-05 prototype towards On-chip digitization of the JUNGFRAU charge-integrating X-ray pixel detector
- Open Access
Investigating the Impact of Sensor Layout on Radiation Hardness in 25 µm Pitch Hybrid Pixel Detectors for 4th Generation Synchrotron Light Sources
With the evolution of synchrotron light sources to fourth generation (diffraction-limited storage rings), the brilliance is increased by several orders of magnitude compared to third generation facilities. For example, the Swiss Light Source (SLS) has been upgraded to SLS 2.0, promising a horizontal emittance reduced by a factor of 40, and a brilliance up to two orders of magnitude (three at higher energies). A key challenge arising from the increased flux is the heightened accumulated dose in silicon sensors, which leads to a significant increase in radiation damage. This translates into an increase of both noise and dark current, as well as a reduction in the dynamic range for long exposure times, thus affecting the performance of the detector, in particular, for charge-integrating detectors. We have designed sensors with a 4 × 4 mm2 pixel array featuring 16 design variations of 25 µm pitch pixels with different implant and metal sizes and tested them bump-bonded to MÖNCH 0.3, a charge integrating hybrid pixel detector readout ASIC. Following a first assessment of the functionality and performance of the different pixel designs, the assembly has been irradiated with X-rays. The variation in the tested parameters was characterized at different accumulated doses up to 100 kGy at the sensor entrance window side. The annealing dynamics at room temperature have also been measured. The results show that the default pixel design is currently not optimal and can benefit from layout changes (reduction in the inter-pixel gap area with full metal coverage of the implant). Further studies on the metal coverage over large implants could be conducted. The layout changes are, however, not sufficient for future full-sized sensors, requiring improved radiation hardness and long-term stability, and additional strategies such as focusing on detector cooling and changes in sensor technologies would be required.
Open AccessInvestigating the Impact of Sensor Layout on Radiation Hardness in 25 µm Pitch Hybrid Pixel Detectors for 4th Generation Synchrotron Light Sources
With the evolution of synchrotron light sources to fourth generation (diffraction-limited storage rings), the brilliance is increased by several orders of magnitude compared to third generation facilities. For example, the Swiss Light Source (SLS) has been upgraded to SLS 2.0, promising a horizontal emittance reduced by a factor of 40, and a brilliance up to two orders of magnitude (three at higher energies). A key challenge arising from the increased flux is the heightened accumulated dose in silicon sensors, which leads to a significant increase in radiation damage. This translates into an increase of both noise and dark current, as well as a reduction in the dynamic range for long exposure times, thus affecting the performance of the detector, in particular, for charge-integrating detectors. We have designed sensors with a 4 × 4 mm2 pixel array featuring 16 design variations of 25 µm pitch pixels with different implant and metal sizes and tested them bump-bonded to MÖNCH 0.3, a charge integrating hybrid pixel detector readout ASIC. Following a first assessment of the functionality and performance of the different pixel designs, the assembly has been irradiated with X-rays. The variation in the tested parameters was characterized at different accumulated doses up to 100 kGy at the sensor entrance window side. The annealing dynamics at room temperature have also been measured. The results show that the default pixel design is currently not optimal and can benefit from layout changes (reduction in the inter-pixel gap area with full metal coverage of the implant). Further studies on the metal coverage over large implants could be conducted. The layout changes are, however, not sufficient for future full-sized sensors, requiring improved radiation hardness and long-term stability, and additional strategies such as focusing on detector cooling and changes in sensor technologies would be required.
- Open Access
- 1 October 2024
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 19 (10) , C10007
Optimizing charge transport simulation for hybrid pixel detectors
To enhance the spatial resolution of the MÖNCH 25 µm pitch hybrid pixel detector, deep learning models have been trained using both simulation and measurement data. Challenges arise when comparing simulation-based deep learning models to measurement-based models for electrons, as the spatial resolution achieved through simulations is notably inferior to that from measurements. Discrepancies are also observed when directly comparing X-ray simulations with measurements, particularly in the spectral output of single pixels. These observations collectively suggest that current simulations require optimization. To address this, the dynamics of charge carriers within the silicon sensor have been studied using Monte Carlo simulations, aiming to refine the charge transport modeling. The simulation encompasses the initial generation of the charge cloud, charge cloud drift, charge diffusion and repulsion, and electronic noise. The simulation results were validated with measurements from the MÖNCH detector for X-rays, and the agreement between measurements and simulations was significantly improved by accounting for the charge repulsion.
- 1 October 2024
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 19 (10) , C10007
Open AccessOptimizing charge transport simulation for hybrid pixel detectors
To enhance the spatial resolution of the MÖNCH 25 µm pitch hybrid pixel detector, deep learning models have been trained using both simulation and measurement data. Challenges arise when comparing simulation-based deep learning models to measurement-based models for electrons, as the spatial resolution achieved through simulations is notably inferior to that from measurements. Discrepancies are also observed when directly comparing X-ray simulations with measurements, particularly in the spectral output of single pixels. These observations collectively suggest that current simulations require optimization. To address this, the dynamics of charge carriers within the silicon sensor have been studied using Monte Carlo simulations, aiming to refine the charge transport modeling. The simulation encompasses the initial generation of the charge cloud, charge cloud drift, charge diffusion and repulsion, and electronic noise. The simulation results were validated with measurements from the MÖNCH detector for X-rays, and the agreement between measurements and simulations was significantly improved by accounting for the charge repulsion.
- Open Access
Quantum Efficiency Measurement and Modeling of Silicon Sensors Optimized for Soft X-ray Detection
Hybrid pixel detectors have become indispensable at synchrotron and X-ray free-electron laser facilities thanks to their large dynamic range, high frame rate, low noise, and large area. However, at energies below 3 keV, the detector performance is often limited because of the poor quantum efficiency of the sensor and the difficulty in achieving single-photon resolution due to the low signal-to-noise ratio. In this paper, we address the quantum efficiency of silicon sensors by refining the design of the entrance window, mainly by passivating the silicon surface and optimizing the dopant profile of the n+ region. We present the measurement of the quantum efficiency in the soft X-ray energy range for silicon sensors with several process variations in the fabrication of planar sensors with thin entrance windows. The quantum efficiency for 250 eV photons is increased from almost 0.5% for a standard sensor to up to 62% as a consequence of these developments, comparable to the quantum efficiency of backside-illuminated scientific CMOS sensors. Finally, we discuss the influence of the various process parameters on quantum efficiency and present a strategy for further improvement.Open AccessQuantum Efficiency Measurement and Modeling of Silicon Sensors Optimized for Soft X-ray Detection
Hybrid pixel detectors have become indispensable at synchrotron and X-ray free-electron laser facilities thanks to their large dynamic range, high frame rate, low noise, and large area. However, at energies below 3 keV, the detector performance is often limited because of the poor quantum efficiency of the sensor and the difficulty in achieving single-photon resolution due to the low signal-to-noise ratio. In this paper, we address the quantum efficiency of silicon sensors by refining the design of the entrance window, mainly by passivating the silicon surface and optimizing the dopant profile of the n+ region. We present the measurement of the quantum efficiency in the soft X-ray energy range for silicon sensors with several process variations in the fabrication of planar sensors with thin entrance windows. The quantum efficiency for 250 eV photons is increased from almost 0.5% for a standard sensor to up to 62% as a consequence of these developments, comparable to the quantum efficiency of backside-illuminated scientific CMOS sensors. Finally, we discuss the influence of the various process parameters on quantum efficiency and present a strategy for further improvement. - Open Access
- 1 August 2021
- Published by Elsevier in Ultramicroscopy
- Vol. 227, 113298
Quantifying the performance of a hybrid pixel detector with GaAs:Cr sensor for transmission electron microscopy
- 1 August 2021
- Published by Elsevier in Ultramicroscopy
- Vol. 227, 113298
Open AccessQuantifying the performance of a hybrid pixel detector with GaAs:Cr sensor for transmission electron microscopy
- Open Access
- 4 September 2020
- Published by Oxford University Press (OUP) in Microscopy and Microanalysis
- Vol. 26 (5) , 944-963
Fast Pixelated Detectors in Scanning Transmission Electron Microscopy. Part II: Post-Acquisition Data Processing, Visualization, and Structural Characterization
Fast pixelated detectors incorporating direct electron detection (DED) technology are increasingly being regarded as universal detectors for scanning transmission electron microscopy (STEM), capable of imaging under multiple modes of operation. However, several issues remain around the post-acquisition processing and visualization of the often very large multidimensional STEM datasets produced by them. We discuss these issues and present open source software libraries to enable efficient processing and visualization of such datasets. Throughout, we provide examples of the analysis methodologies presented, utilizing data from a 256 × 256 pixel Medipix3 hybrid DED detector, with a particular focus on the STEM characterization of the structural properties of materials. These include the techniques of virtual detector imaging; higher-order Laue zone analysis; nanobeam electron diffraction; and scanning precession electron diffraction. In the latter, we demonstrate a nanoscale lattice parameter mapping with a fractional precision ≤6 × 10−4 (0.06%).
- 4 September 2020
- Published by Oxford University Press (OUP) in Microscopy and Microanalysis
- Vol. 26 (5) , 944-963
Open AccessFast Pixelated Detectors in Scanning Transmission Electron Microscopy. Part II: Post-Acquisition Data Processing, Visualization, and Structural Characterization
Fast pixelated detectors incorporating direct electron detection (DED) technology are increasingly being regarded as universal detectors for scanning transmission electron microscopy (STEM), capable of imaging under multiple modes of operation. However, several issues remain around the post-acquisition processing and visualization of the often very large multidimensional STEM datasets produced by them. We discuss these issues and present open source software libraries to enable efficient processing and visualization of such datasets. Throughout, we provide examples of the analysis methodologies presented, utilizing data from a 256 × 256 pixel Medipix3 hybrid DED detector, with a particular focus on the STEM characterization of the structural properties of materials. These include the techniques of virtual detector imaging; higher-order Laue zone analysis; nanobeam electron diffraction; and scanning precession electron diffraction. In the latter, we demonstrate a nanoscale lattice parameter mapping with a fractional precision ≤6 × 10−4 (0.06%).
- Open Access
- 6 July 2020
- Published by Oxford University Press (OUP) in Microscopy and Microanalysis
- Vol. 26 (4) , 653-666
Fast Pixelated Detectors in Scanning Transmission Electron Microscopy. Part I: Data Acquisition, Live Processing, and Storage
The use of fast pixelated detectors and direct electron detection technology is revolutionizing many aspects of scanning transmission electron microscopy (STEM). The widespread adoption of these new technologies is impeded by the technical challenges associated with them. These include issues related to hardware control, and the acquisition, real-time processing and visualization, and storage of data from such detectors. We discuss these problems and present software solutions for them, with a view to making the benefits of new detectors in the context of STEM more accessible. Throughout, we provide examples of the application of the technologies presented, using data from a Medipix3 direct electron detector. Most of our software are available under an open source licence, permitting transparency of the implemented algorithms, and allowing the community to freely use and further improve upon them.
- 6 July 2020
- Published by Oxford University Press (OUP) in Microscopy and Microanalysis
- Vol. 26 (4) , 653-666
Open AccessFast Pixelated Detectors in Scanning Transmission Electron Microscopy. Part I: Data Acquisition, Live Processing, and Storage
The use of fast pixelated detectors and direct electron detection technology is revolutionizing many aspects of scanning transmission electron microscopy (STEM). The widespread adoption of these new technologies is impeded by the technical challenges associated with them. These include issues related to hardware control, and the acquisition, real-time processing and visualization, and storage of data from such detectors. We discuss these problems and present software solutions for them, with a view to making the benefits of new detectors in the context of STEM more accessible. Throughout, we provide examples of the application of the technologies presented, using data from a Medipix3 direct electron detector. Most of our software are available under an open source licence, permitting transparency of the implemented algorithms, and allowing the community to freely use and further improve upon them.