Mohammad Rafie Khorgami
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Mohammad Rafie Khorgami has a total of 101 co-authors. Here are the top co-authors by number of shared publications:
Negar Omidi
Cardiac Primary Prevention Research Center, Cardiovascular Disease Research Institute, Tehran Heart Center (THC), Tehran University of Medical Sciences, Tehran, Iran
4 shared publications- Negar Omidi
Cardiac Primary Prevention Research Center, Cardiovascular Diseases Research Institute, Tehran University of Medical Sciences, Tehran, Iran
3 shared publications Avisa Tabib
Rajaie Cardiovascular Medical and Research Center, Iran University of Medical Sciences, Tehran, Iran
2 shared publicationsBahareh Kazem Borji
Rajaie Cardiovascular Medical and Research Center, Iran University of Medical Sciences, Tehran, Iran
2 shared publicationsGhasem Hajianfar
Rajaie Cardiovascular Medical and Research Center, Iran University of Medical Sciences, Tehran, Iran
2 shared publications- Golnaz Houshmand
Cardiovascular Imaging Research Center, Rajaie Cardiovascular Institute, Tehran, Iran
2 shared publications
Latest Publications
- Open Access
- 1 January 2026
- Published by Wiley in Cardiology Research and Practice
- Vol. 2026 (1) , 3131535
Applicability of Stress Cardiac Magnetic Resonance Imaging in Patients With Cardiac Implantable Devices: A Systematic Review
Purpose: The utilization of stress perfusion cardiac magnetic resonance (CMR) in patients with cardiac implantable electronic devices (CIEDs) is still limited. Methods: The study was registered in the Prospective Register of Systematic Reviews (PROSPERO) with ID CRD42023457308. PubMed, Scopus, Embase, Web of Science, ProQuest, and CINAHL databases were searched using the Mesh and related terms of CMR imaging, stress, and CIEDs. Results: Out of the 1695 papers we found, eight met our inclusion criteria. We reviewed the included studies and provided a concluding remark concerning (a) image quality; (b) CMR compatibility, scanner, and safety; (c) device protocols and exclusion criteria; (d) vasodilator choices, effects, and safety; and (e) clinical outcomes. Conclusion: This study has demonstrated a positive trend in the utilization of stress CMR in MR‐conditional devices. However, the review has identified multiple research gaps that warrant further investigation.
- 1 January 2026
- Published by Wiley in Cardiology Research and Practice
- Vol. 2026 (1) , 3131535
Open AccessApplicability of Stress Cardiac Magnetic Resonance Imaging in Patients With Cardiac Implantable Devices: A Systematic Review
Purpose: The utilization of stress perfusion cardiac magnetic resonance (CMR) in patients with cardiac implantable electronic devices (CIEDs) is still limited. Methods: The study was registered in the Prospective Register of Systematic Reviews (PROSPERO) with ID CRD42023457308. PubMed, Scopus, Embase, Web of Science, ProQuest, and CINAHL databases were searched using the Mesh and related terms of CMR imaging, stress, and CIEDs. Results: Out of the 1695 papers we found, eight met our inclusion criteria. We reviewed the included studies and provided a concluding remark concerning (a) image quality; (b) CMR compatibility, scanner, and safety; (c) device protocols and exclusion criteria; (d) vasodilator choices, effects, and safety; and (e) clinical outcomes. Conclusion: This study has demonstrated a positive trend in the utilization of stress CMR in MR‐conditional devices. However, the review has identified multiple research gaps that warrant further investigation.
- Open Access
- 1 January 2026
- Published by Wiley in Cardiology Research and Practice
- Vol. 2026 (1)
The Trace of c.3747_3748insGG Variation of the MYBPC3 Gene in the Family With Atrioventricular Canal Defect
Background: Atrioventricular canal defect (AVCD) is a congenital heart disease often associated with genetic changes, with a broad spectrum of anatomical patterns. Aim: We present a novel likely pathogenic variant of MYBPC3 in a proband with AVCD. Methods: A clinical and genetic evaluation was conducted on a one‐year‐old Iranian girl referred to our center with cardiac structural abnormalities and her family. Transthoracic echocardiography (TTE) and cardiac computed tomography (CT) were employed for clinical evaluation, and whole exome sequencing (WES), polymerase chain reaction (PCR), and Sanger sequencing were utilized for genetic analysis. Results: TTE revealed a ventricular and atrial septal defect (ASD), along with pulmonary hypertension (PH). The proband was diagnosed with AVCD through cardiac CT. WES identified a novel heterozygous MYBPC3 (NM_000256.3): c.3747_3748insGG; p.(Ile1250Glyfs∗82). Segregation analysis confirmed the presence of the same variant in the proband’s father, who was diagnosed with hypertrophic cardiomyopathy (HCM). Conclusion: We presented the first case of AVCD associated with a novel MYBPC3 variant, expanding the spectrum of cardiac anomalies linked to MYBPC3 mutations. The findings highlight the complexity and variable expression of MYBPC3 within affected family members.
- 1 January 2026
- Published by Wiley in Cardiology Research and Practice
- Vol. 2026 (1)
Open AccessThe Trace of c.3747_3748insGG Variation of the MYBPC3 Gene in the Family With Atrioventricular Canal Defect
Background: Atrioventricular canal defect (AVCD) is a congenital heart disease often associated with genetic changes, with a broad spectrum of anatomical patterns. Aim: We present a novel likely pathogenic variant of MYBPC3 in a proband with AVCD. Methods: A clinical and genetic evaluation was conducted on a one‐year‐old Iranian girl referred to our center with cardiac structural abnormalities and her family. Transthoracic echocardiography (TTE) and cardiac computed tomography (CT) were employed for clinical evaluation, and whole exome sequencing (WES), polymerase chain reaction (PCR), and Sanger sequencing were utilized for genetic analysis. Results: TTE revealed a ventricular and atrial septal defect (ASD), along with pulmonary hypertension (PH). The proband was diagnosed with AVCD through cardiac CT. WES identified a novel heterozygous MYBPC3 (NM_000256.3): c.3747_3748insGG; p.(Ile1250Glyfs∗82). Segregation analysis confirmed the presence of the same variant in the proband’s father, who was diagnosed with hypertrophic cardiomyopathy (HCM). Conclusion: We presented the first case of AVCD associated with a novel MYBPC3 variant, expanding the spectrum of cardiac anomalies linked to MYBPC3 mutations. The findings highlight the complexity and variable expression of MYBPC3 within affected family members.
- 17 October 2023
- Published by Springer Nature in Cardiovascular Engineering and Technology
- Vol. 14 (6) , 786-800
Comparison of Machine Learning Algorithms Using Manual/Automated Features on 12-Lead Signal Electrocardiogram Classification: A Large Cohort Study on Students Aged Between 6 to 18 Years Old
Propose An electrocardiogram (ECG) has been extensively used to detect rhythm disturbances. We sought to determine the accuracy of different machine learning in distinguishing abnormal ECGs from normal ones in children who were examined using a resting 12-Lead ECG machine, and we also compared the manual and automated measurement using the modular ECG Analysis System (MEANS) algorithm of ECG features. Methods Altogether, 10745 ECGs were recorded for students aged 6 to 18. Manual and automatic ECG features were extracted for each participant. Features were normalized using Z-score normalization and went through the student’s t-test and chi-squared test to measure their relevance. We applied the Boruta algorithm for feature selection and then implemented eight classifier algorithms. The dataset was split into training (80%) and test (20%) partitions. The performance of the classifiers was evaluated on the test data (unseen data) by 1000 bootstrap, and sensitivity (SEN), specificity (SPE), AUC, and accuracy (ACC) were reported. Results In univariate analysis, the highest performance was heart rate and RR interval in the manual dataset and heart rate in an automated dataset with AUC of 0.72 and 0.71, respectively. The best classifiers in the manual dataset were random forest (RF) and quadratic-discriminant-analysis (QDA) with AUC, ACC, SEN, and SPE equal to 0.93, 0.98, 0.69, 0.99, and 0.90, 0.95, 0.75, 0.96, respectively. In the automated dataset, QDA (AUC: 0.89, ACC:0.92, SEN:0.71, SPE:0.93) and stack learning (SL) (AUC:0.89, ACC:0.96, SEN:0.61, SPE:0.99) reached best performances. Conclusion This study demonstrated that the manual measurement of 12-Lead ECG features had better performance than the automated measurement (MEANS algorithm), but some classifiers had promising results in discriminating between normal and abnormal cases. Further studies can help us evaluate the applicability and efficacy of machine-learning approaches for distinguishing abnormal ECGs in community-based investigations in both adults and children.
- 17 October 2023
- Published by Springer Nature in Cardiovascular Engineering and Technology
- Vol. 14 (6) , 786-800
Comparison of Machine Learning Algorithms Using Manual/Automated Features on 12-Lead Signal Electrocardiogram Classification: A Large Cohort Study on Students Aged Between 6 to 18 Years Old
Propose An electrocardiogram (ECG) has been extensively used to detect rhythm disturbances. We sought to determine the accuracy of different machine learning in distinguishing abnormal ECGs from normal ones in children who were examined using a resting 12-Lead ECG machine, and we also compared the manual and automated measurement using the modular ECG Analysis System (MEANS) algorithm of ECG features. Methods Altogether, 10745 ECGs were recorded for students aged 6 to 18. Manual and automatic ECG features were extracted for each participant. Features were normalized using Z-score normalization and went through the student’s t-test and chi-squared test to measure their relevance. We applied the Boruta algorithm for feature selection and then implemented eight classifier algorithms. The dataset was split into training (80%) and test (20%) partitions. The performance of the classifiers was evaluated on the test data (unseen data) by 1000 bootstrap, and sensitivity (SEN), specificity (SPE), AUC, and accuracy (ACC) were reported. Results In univariate analysis, the highest performance was heart rate and RR interval in the manual dataset and heart rate in an automated dataset with AUC of 0.72 and 0.71, respectively. The best classifiers in the manual dataset were random forest (RF) and quadratic-discriminant-analysis (QDA) with AUC, ACC, SEN, and SPE equal to 0.93, 0.98, 0.69, 0.99, and 0.90, 0.95, 0.75, 0.96, respectively. In the automated dataset, QDA (AUC: 0.89, ACC:0.92, SEN:0.71, SPE:0.93) and stack learning (SL) (AUC:0.89, ACC:0.96, SEN:0.61, SPE:0.99) reached best performances. Conclusion This study demonstrated that the manual measurement of 12-Lead ECG features had better performance than the automated measurement (MEANS algorithm), but some classifiers had promising results in discriminating between normal and abnormal cases. Further studies can help us evaluate the applicability and efficacy of machine-learning approaches for distinguishing abnormal ECGs in community-based investigations in both adults and children.
- 3 August 2023
- Published by Springer Nature in Heart Failure Reviews
- Vol. 28 (6) , 1357-1382
Cost-effectiveness of cardiovascular magnetic resonance imaging compared to common strategies in the diagnosis of coronary artery disease: a systematic review
Cardiovascular magnetic resonance imaging (CMR) has established exceptional diagnostic utility and prognostic value in coronary artery disease (CAD). An assessment of the current evidence on the cost-effectiveness of CMR in patients referred for the investigation of CAD is essential for developing an economic model to evaluate the cost-effectiveness of CMR in CAD. We conducted a comprehensive search of multiple electronic databases, including PubMed, Scopus, Web of Science core collection, Embase, National Health Service Economic Evaluation Database (NHS EED), and health technology assessment, to identify relevant literature. After removing duplicates and screening the title/abstract, a total of 13 articles were deemed eligible for full-text assessment. We included studies that reported one or more of the following outcomes: incremental cost-effectiveness ratio (ICER), cost per quality-adjusted life year (QALYs), cost per life year gained, sensitivity and specificity rate as the primary outcome, and health utility measures or health-related quality of life as the secondary outcome. The quality of the included studies was assessed using the CHEERS 2022 guidelines. The findings of this study demonstrate that in patients undergoing urgent percutaneous coronary intervention, CMR over a one-year and lifetime horizon leads to higher quality-adjusted life years (QALYs) compared to current strategies in cases of multivessel disease. The systematic review indicates that the CMR-based strategy is more cost-effective when compared to standard methods such as single-photon emission computed tomography (SPECT), coronary computed tomography angiography (CCTA), and coronary angiography (CA) (CMR = $19,273, SPECT = $19,578, CCTA = $19,886, and immediate CA = $20,929). The results also suggest that the CMR strategy can serve as a cost-effective gatekeeping tool for patients at risk of obstructive CAD. A CMR-based strategy for managing patients with suspected CAD is more cost-effective compared to both invasive and non-invasive strategies, particularly in real-world patient populations with a low to intermediate prevalence of the disease.
- 3 August 2023
- Published by Springer Nature in Heart Failure Reviews
- Vol. 28 (6) , 1357-1382
Cost-effectiveness of cardiovascular magnetic resonance imaging compared to common strategies in the diagnosis of coronary artery disease: a systematic review
Cardiovascular magnetic resonance imaging (CMR) has established exceptional diagnostic utility and prognostic value in coronary artery disease (CAD). An assessment of the current evidence on the cost-effectiveness of CMR in patients referred for the investigation of CAD is essential for developing an economic model to evaluate the cost-effectiveness of CMR in CAD. We conducted a comprehensive search of multiple electronic databases, including PubMed, Scopus, Web of Science core collection, Embase, National Health Service Economic Evaluation Database (NHS EED), and health technology assessment, to identify relevant literature. After removing duplicates and screening the title/abstract, a total of 13 articles were deemed eligible for full-text assessment. We included studies that reported one or more of the following outcomes: incremental cost-effectiveness ratio (ICER), cost per quality-adjusted life year (QALYs), cost per life year gained, sensitivity and specificity rate as the primary outcome, and health utility measures or health-related quality of life as the secondary outcome. The quality of the included studies was assessed using the CHEERS 2022 guidelines. The findings of this study demonstrate that in patients undergoing urgent percutaneous coronary intervention, CMR over a one-year and lifetime horizon leads to higher quality-adjusted life years (QALYs) compared to current strategies in cases of multivessel disease. The systematic review indicates that the CMR-based strategy is more cost-effective when compared to standard methods such as single-photon emission computed tomography (SPECT), coronary computed tomography angiography (CCTA), and coronary angiography (CA) (CMR = $19,273, SPECT = $19,578, CCTA = $19,886, and immediate CA = $20,929). The results also suggest that the CMR strategy can serve as a cost-effective gatekeeping tool for patients at risk of obstructive CAD. A CMR-based strategy for managing patients with suspected CAD is more cost-effective compared to both invasive and non-invasive strategies, particularly in real-world patient populations with a low to intermediate prevalence of the disease.
- Open Access
- 21 April 2022
- Published by Springer Nature in Research Square
Electrocardiogram Signal Classification Using Manual/Automated Features and Machine Learning Algorithms: A Large Cohort Study on Students Aging from 6 to 18 Years Old
Cardiac rhythm abnormalities are one of the main cardiovascular diseases leading to morbidity and mortalities. Electrocardiogram (ECG), since its introduction, has been extensively used for the detection of rhythm disturbances The differentiation of abnormal ECG from normal one is the cornerstone of public health programs. The interpretation of ECGs by physicians is a time-consuming process that is not free of faults. In this study we sought to determine the accuracy of different machine learning models in distinguishing abnormal ECGs from normal ones in a large sample of in-house data sets of children’s who were examined using resting ECG machine during a community-based study. Altogether, 10745 ECGs were recorded for student aging from 6 to 18 years old. Manual and automatic ECG features were extracted for each participant. Features were normalized using Z-score normalization and went through the student’s t-test and chi-squared test to measure their relevance. All p-values were corrected with Benjamini-Hochberg (BH) method and were reported as q-value. We applied Boruta algorithm for feature selection and then implemented 8 different classifiers, including eXtreme Gradient Boosting (XGB), Support Vector Machine (SVM), Quadratic Discriminant Analysis (QDA); Random Forest (RF), Decision Tree (DT), K-nearest neighbors (KNN), Logistic Regression (LR), and Stack Learning (SL) for classification purpose. The dataset was split into training (80%) and test (20%) partitions. Hyper-parameter optimization of classifiers was performed on selected features by 10-fold cross validation and random search. Optimal models were made on training dataset and performance of the models was evaluated on the test data (unseen data) by 1000 bootstrap. We also reported mean ± SD and 95% confidence interval (CI) for each model. The performance of models was evaluated by sensitivity (SEN), specificity (SPE), AUC, and accuracy (ACC). In univariate analysis, the highest performance feature was heart rate and RR interval in the manual dataset with an AUC of 0.72, followed by heart rate in automated dataset with an AUC of 0.71. We also found QT in both of datasets had an AUC of 0.68. The Boruta method selected 15 and 16 features in the manual and the automated datasets, respectively. The best models in the manual dataset were RF and QDA model with AUC, ACC, SEN, SPE equal to 0.93,0.98, 0.69, 0.99 and 0.90, 0.95, 0.75, 0.96, respectively. In the automated dataset, QDA (AUC: 0.89, ACC: 0.92, SEN: 0.71, SPE: 0.93), and SL (AUC: 0.89, ACC: 0.96, SEN: 0.61, SPE: 0.99) reached best performances. This study demonstrated that the manual measurement of ECG features had better performance than the automated measurement but automated measurement in some model had promising result in discriminating normal and abnormal cases.
- 21 April 2022
- Published by Springer Nature in Research Square
Open AccessElectrocardiogram Signal Classification Using Manual/Automated Features and Machine Learning Algorithms: A Large Cohort Study on Students Aging from 6 to 18 Years Old
Cardiac rhythm abnormalities are one of the main cardiovascular diseases leading to morbidity and mortalities. Electrocardiogram (ECG), since its introduction, has been extensively used for the detection of rhythm disturbances The differentiation of abnormal ECG from normal one is the cornerstone of public health programs. The interpretation of ECGs by physicians is a time-consuming process that is not free of faults. In this study we sought to determine the accuracy of different machine learning models in distinguishing abnormal ECGs from normal ones in a large sample of in-house data sets of children’s who were examined using resting ECG machine during a community-based study. Altogether, 10745 ECGs were recorded for student aging from 6 to 18 years old. Manual and automatic ECG features were extracted for each participant. Features were normalized using Z-score normalization and went through the student’s t-test and chi-squared test to measure their relevance. All p-values were corrected with Benjamini-Hochberg (BH) method and were reported as q-value. We applied Boruta algorithm for feature selection and then implemented 8 different classifiers, including eXtreme Gradient Boosting (XGB), Support Vector Machine (SVM), Quadratic Discriminant Analysis (QDA); Random Forest (RF), Decision Tree (DT), K-nearest neighbors (KNN), Logistic Regression (LR), and Stack Learning (SL) for classification purpose. The dataset was split into training (80%) and test (20%) partitions. Hyper-parameter optimization of classifiers was performed on selected features by 10-fold cross validation and random search. Optimal models were made on training dataset and performance of the models was evaluated on the test data (unseen data) by 1000 bootstrap. We also reported mean ± SD and 95% confidence interval (CI) for each model. The performance of models was evaluated by sensitivity (SEN), specificity (SPE), AUC, and accuracy (ACC). In univariate analysis, the highest performance feature was heart rate and RR interval in the manual dataset with an AUC of 0.72, followed by heart rate in automated dataset with an AUC of 0.71. We also found QT in both of datasets had an AUC of 0.68. The Boruta method selected 15 and 16 features in the manual and the automated datasets, respectively. The best models in the manual dataset were RF and QDA model with AUC, ACC, SEN, SPE equal to 0.93,0.98, 0.69, 0.99 and 0.90, 0.95, 0.75, 0.96, respectively. In the automated dataset, QDA (AUC: 0.89, ACC: 0.92, SEN: 0.71, SPE: 0.93), and SL (AUC: 0.89, ACC: 0.96, SEN: 0.61, SPE: 0.99) reached best performances. This study demonstrated that the manual measurement of ECG features had better performance than the automated measurement but automated measurement in some model had promising result in discriminating normal and abnormal cases.
- Open Access
- 11 January 2022
- Published by Ubiquity Press, Ltd. in Global Heart
- Vol. 17 (1) , 39
Prevalence of Structural Heart Diseases Detected by Handheld Echocardiographic Device in School-Age Children in Iran: The SHED LIGHT Study
Structural heart disease (SHD) has great impacts on healthcare systems, creating further public health concerns. Proper data are scant regarding the magnitude of the affected population by SHD. This study aimed to determine the prevalence of SHD among children and adolescents in an Iranian population. In this population-based study, a multistage cluster-random sampling was used to choose schools from the Tehran urban area. All students were examined using a handheld Vscan device by echocardiographer, and the results were concurrently supervised and interpreted by cardiologists. All the major findings were reevaluated in hospital clinics. Of 15,130 students (6–18 years, 52.2% boys) who were examined, the prevalence of individuals with congenital heart disease (CHD) and cardiomyopathy was 152 (10.046 per 1,000 persons) and 9 (0.595 per 1,000 persons), respectively. The prevalence of definite and borderline rheumatic heart disease (RHD) was 30 (2 per 1,000 persons) and 113 (7.5 per 1,000 persons), correspondingly. Non-rheumatic valvular heart disease (VHD) was also detected in 465 (30.7 per 1,000 persons) students. Of all the pathologies, only 39 (25.6%) cases with CHD and 1 (0.007%) cases with RHD had already been diagnosed. Parental consanguinity was the strongest predictor of CHD and SHD (odds ratio [OR]: 1.907, 95% CI, 1.358 to 2.680; P < 0.001 and OR, 1.855, 95% CI, 1.334 to 2.579; P < 0.001, respectively). The female sex (OR, 1.262, 95% CI, 1.013 to 1.573; P = 0.038) and fathers’ low literacy (OR, 1.872, 95% CI, 1.068 to 3.281; P = 0.029) were the strongest predictors of non-rheumatic VHD and RHD, correspondingly. The implementation of echocardiographic examinations for detecting SHD among young population is feasible which detected SHD prevalence in our population comparable to previous reports. Further studies are required to delineate its economic aspects for community-based screening.
- 11 January 2022
- Published by Ubiquity Press, Ltd. in Global Heart
- Vol. 17 (1) , 39
Open AccessPrevalence of Structural Heart Diseases Detected by Handheld Echocardiographic Device in School-Age Children in Iran: The SHED LIGHT Study
Structural heart disease (SHD) has great impacts on healthcare systems, creating further public health concerns. Proper data are scant regarding the magnitude of the affected population by SHD. This study aimed to determine the prevalence of SHD among children and adolescents in an Iranian population. In this population-based study, a multistage cluster-random sampling was used to choose schools from the Tehran urban area. All students were examined using a handheld Vscan device by echocardiographer, and the results were concurrently supervised and interpreted by cardiologists. All the major findings were reevaluated in hospital clinics. Of 15,130 students (6–18 years, 52.2% boys) who were examined, the prevalence of individuals with congenital heart disease (CHD) and cardiomyopathy was 152 (10.046 per 1,000 persons) and 9 (0.595 per 1,000 persons), respectively. The prevalence of definite and borderline rheumatic heart disease (RHD) was 30 (2 per 1,000 persons) and 113 (7.5 per 1,000 persons), correspondingly. Non-rheumatic valvular heart disease (VHD) was also detected in 465 (30.7 per 1,000 persons) students. Of all the pathologies, only 39 (25.6%) cases with CHD and 1 (0.007%) cases with RHD had already been diagnosed. Parental consanguinity was the strongest predictor of CHD and SHD (odds ratio [OR]: 1.907, 95% CI, 1.358 to 2.680; P < 0.001 and OR, 1.855, 95% CI, 1.334 to 2.579; P < 0.001, respectively). The female sex (OR, 1.262, 95% CI, 1.013 to 1.573; P = 0.038) and fathers’ low literacy (OR, 1.872, 95% CI, 1.068 to 3.281; P = 0.029) were the strongest predictors of non-rheumatic VHD and RHD, correspondingly. The implementation of echocardiographic examinations for detecting SHD among young population is feasible which detected SHD prevalence in our population comparable to previous reports. Further studies are required to delineate its economic aspects for community-based screening.
- Open Access
- 1 January 2022
- Published by Elsevier in Revista Portuguesa de Cardiologia
- Vol. 41 (1) , 43-47
Electrocardiographic indices and pregnancy: A focus on changes between first and third trimesters
- 1 January 2022
- Published by Elsevier in Revista Portuguesa de Cardiologia
- Vol. 41 (1) , 43-47
Open AccessElectrocardiographic indices and pregnancy: A focus on changes between first and third trimesters
- Open Access
- 1 June 2021
- Published by Elsevier in IJC Heart & Vasculature
- Vol. 34, 100805
Effects of methylphenidate on blood pressure, QT-interval, and cardiac output in ADHD diagnosed children: A three months’ follow-up study
- 1 June 2021
- Published by Elsevier in IJC Heart & Vasculature
- Vol. 34, 100805
Open AccessEffects of methylphenidate on blood pressure, QT-interval, and cardiac output in ADHD diagnosed children: A three months’ follow-up study
- Open Access
- 20 May 2021
- Published by Maad Rayan Publishing Company in Journal of Cardiovascular and Thoracic Research
- Vol. 13 (2) , 156-161
Percutaneous Balloon Pulmonary Valvuloplasty of Critical Pulmonary Stenosis and severe pulmonary stenosis in Neonates and Early Infancy: A Challenge in the Cyanotic
Introduction: Pulmonary stenosis with an intact ventricular septum (PS-IVS) is one of the common causes of cyanotic heart disease in neonates with diverse morphologies as well as management and treatment protocols. The aim of this study was to evaluate short and midterm results of balloon pulmonary valvuloplasty (BPV) for this disorder. Methods: Between 2012 and 2016, Totally 45 neonates and infants under 6 months old were evaluated.The patients had a minimum right-to-left ventricular pressure ratio of 1, right-to-left shunting at the patent foramen ovale or atrial septal defect level, and tricuspid valve Z-scores higher than -4. Results: Immediately after the procedure, the right ventricular pressure dropped to the normal values in 8 (20%) patients. The immediate procedural success rate was seen in 42 (93.3%) cases: the right-to-left ventricular pressure ratio dropped to below 50% or the level of O2 saturation rose above 75%. Of three cases unresponsive to BPV, two of them underwent patent ductus arteriosus (PDA) stenting and one procedural death occurred. At 6 months’ follow-up, of 42 patients, this pressure was still with in the normal range in 36 (80%) infants, while it had returned to high values in 9 (20%) patients and necessitated repeat valvuloplasty. After BPV, severe pulmonary valve regurgitation was observed in14.2% patients; the condition was more common when high-profile noncompliant balloons were used. Conclusion: Balloon pulmonary valvuloplasty in infants with PS-IVS confers acceptable results insofar as it improves echocardiographic parameters and hemodynamic changes at short- and midterm followups.Balloon selection with sizes more than 1.2 of the diameter of the pulmonary valve annulus and the use of noncompliant high-pressure balloons results in higher degrees of pulmonary regurgitation.
- 20 May 2021
- Published by Maad Rayan Publishing Company in Journal of Cardiovascular and Thoracic Research
- Vol. 13 (2) , 156-161
Open AccessPercutaneous Balloon Pulmonary Valvuloplasty of Critical Pulmonary Stenosis and severe pulmonary stenosis in Neonates and Early Infancy: A Challenge in the Cyanotic
Introduction: Pulmonary stenosis with an intact ventricular septum (PS-IVS) is one of the common causes of cyanotic heart disease in neonates with diverse morphologies as well as management and treatment protocols. The aim of this study was to evaluate short and midterm results of balloon pulmonary valvuloplasty (BPV) for this disorder. Methods: Between 2012 and 2016, Totally 45 neonates and infants under 6 months old were evaluated.The patients had a minimum right-to-left ventricular pressure ratio of 1, right-to-left shunting at the patent foramen ovale or atrial septal defect level, and tricuspid valve Z-scores higher than -4. Results: Immediately after the procedure, the right ventricular pressure dropped to the normal values in 8 (20%) patients. The immediate procedural success rate was seen in 42 (93.3%) cases: the right-to-left ventricular pressure ratio dropped to below 50% or the level of O2 saturation rose above 75%. Of three cases unresponsive to BPV, two of them underwent patent ductus arteriosus (PDA) stenting and one procedural death occurred. At 6 months’ follow-up, of 42 patients, this pressure was still with in the normal range in 36 (80%) infants, while it had returned to high values in 9 (20%) patients and necessitated repeat valvuloplasty. After BPV, severe pulmonary valve regurgitation was observed in14.2% patients; the condition was more common when high-profile noncompliant balloons were used. Conclusion: Balloon pulmonary valvuloplasty in infants with PS-IVS confers acceptable results insofar as it improves echocardiographic parameters and hemodynamic changes at short- and midterm followups.Balloon selection with sizes more than 1.2 of the diameter of the pulmonary valve annulus and the use of noncompliant high-pressure balloons results in higher degrees of pulmonary regurgitation.
- Open Access
- 16 December 2020
- Published by Brieflands in Archives of Pediatric Infectious Diseases
- Vol. 9 (3)
Left Atrial Myxoma Misdiagnosis as Infective Endocarditis: A Case Report
Introduction: Myxomas, as primary cardiac tumors, are rare neoplasms manifesting with constitutional, obstructive, and embolic symptoms. Systemic signs and symptoms make infective endocarditis one of the most common differential diagnoses. Nonspecific systemic signs and symptoms of myxomas can cause great challenges in management and treatment. Case Presentation: A 21-month-old boy was admitted to our center with a high-grade fever and gastrointestinal symptoms, but no significant respiratory complaints were noted. A history of lower limb pain and morning claudication was also present. The patient had leukocytosis with an elevated erythrocyte sedimentation rate (ESR) of two months' duration. Other acute phase reactants were detected despite previous antibiotic therapy; however, his blood culture result was negative. In echocardiography, multiple masses were seen in the left atrium near the mitral valve apparatus. The diagnosis of infective endocarditis was made, and intravenous antibiotics were prescribed for up to two weeks. He then underwent surgery because of poor response to medical treatment and renal complications. During surgery, a small mass was seen in the left atrium, and two other masses were within the mitral chordae. The histopathology report confirmed atrial myxoma. Shortly after surgical resection of the tumors, the patient's symptoms improved, and inflammatory indices returned to normal. Conclusions: Constitutional manifestations of myxoma render it reasonable to consider it as a differential diagnosis of infective endocarditis. Obtaining a complete clinical history and using imaging tools are necessary for the correct diagnosis and prevention of complications of inappropriate treatment.
- 16 December 2020
- Published by Brieflands in Archives of Pediatric Infectious Diseases
- Vol. 9 (3)
Open AccessLeft Atrial Myxoma Misdiagnosis as Infective Endocarditis: A Case Report
Introduction: Myxomas, as primary cardiac tumors, are rare neoplasms manifesting with constitutional, obstructive, and embolic symptoms. Systemic signs and symptoms make infective endocarditis one of the most common differential diagnoses. Nonspecific systemic signs and symptoms of myxomas can cause great challenges in management and treatment. Case Presentation: A 21-month-old boy was admitted to our center with a high-grade fever and gastrointestinal symptoms, but no significant respiratory complaints were noted. A history of lower limb pain and morning claudication was also present. The patient had leukocytosis with an elevated erythrocyte sedimentation rate (ESR) of two months' duration. Other acute phase reactants were detected despite previous antibiotic therapy; however, his blood culture result was negative. In echocardiography, multiple masses were seen in the left atrium near the mitral valve apparatus. The diagnosis of infective endocarditis was made, and intravenous antibiotics were prescribed for up to two weeks. He then underwent surgery because of poor response to medical treatment and renal complications. During surgery, a small mass was seen in the left atrium, and two other masses were within the mitral chordae. The histopathology report confirmed atrial myxoma. Shortly after surgical resection of the tumors, the patient's symptoms improved, and inflammatory indices returned to normal. Conclusions: Constitutional manifestations of myxoma render it reasonable to consider it as a differential diagnosis of infective endocarditis. Obtaining a complete clinical history and using imaging tools are necessary for the correct diagnosis and prevention of complications of inappropriate treatment.