COCan Ozturker

Can Ozturker

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Can Ozturker has a total of 23 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Çocuk Sağlığı İzleminde Görmenin Değerlendirilmesi

    by Gökçen Cerrah, Gonca Keskindemirci, Can Öztürker, Emine Gökçay

  • Septum-sparing minimally invasive technique for levator advancement surgery in aponeurotic ptosis

    by Selva Nur Cukurova Kartal, Can Ozturker, Kemal Turgay Ozbilen

    Purpose To evaluate the outcome of small incision levator advancement with septum-sparing technique and compare it with standard levator advancement. Methods The surgical findings and clinical data of patients with aponeurotic ptosis who underwent small incision or standard levator advancement surgery in our clinic between 2018 and 2020 were analyzed retrospectively. For both groups; age, gender, systemic and ophthalmic comorbidities, levator function, preoperative and postoperative margin-reflex distance, change in margin-reflex distance after surgery, symmetry between the eyes, follow-up time, perioperative and postoperative complications (under/overcorrection, contour irregularity, lagophthalmos) were all evaluated and recorded. Results The study included 82 eyes, 46 from 31 patients in Group I who had small incision surgery, and 36 from 26 patients in Group II who had standard levator surgery. There was no statistically significant difference in surgical success between the two groups (80% and 81% respectively, p = 0.692). The levator function and preoperative margin-reflex distance correlated positively with surgical success. Conclusion Small incision levator advancement is a less invasive procedure than standard levator advancement because of the smaller skin incision and preservation of orbital septum integrity, but it requires good knowledge of eyelid anatomy and experience in eyelid surgery. In patients with aponeurotic ptosis, this surgery can be performed as a safe and effective surgical technique with a similar success rate as standard levator advancement.

  • Open Access

    Surgical Repair of Orbital Blow-Out Fractures: Outcomes and Complications

    by Can Öztürker

    The purpose of this study is to evaluate the demographics of patients with orbital blow-out fractures, as well as the success and complications of surgical repair with porous polyethylene membrane sheet implants through transconjunctival technique and to compare the results to previously published studies. This retrospective study included 57 patients diagnosed with orbital blow-out fractures referred to our clinic between 2018 and 2022. Seventeen patients (29.8%) underwent orbital fracture repair through a transconjunctival technique employing porous polyethylene membrane sheets. The indications for surgery were enophthalmos >2 mm and persistent ocular motility restriction, diplopia, and strabismus. The success criteria were <2 mm of enophthalmos and complete correction of eye motility, diplopia, and strabismus. The study group consisted of ten females and 47 males with a mean age of 31.12 years. The most common cause of injury was assaults (50.9%), followed by falls (38.6%), traffic accidents (5.3%), and accidental impacts (5.3%). The inferior wall (61.4%) was the most common fracture site, followed by the medial wall (21.1%) and a combination of the inferior and medial walls (21.1%). The surgically treated group showed a significant improvement in ocular motility restriction (88.2–23.5%, p=0.002), diplopia (70.6–23.5%, p=0.008), and enophthalmos (1.41 mm to 0.82 mm, p=0.012) after surgery. The surgery was successful in ten of 17 cases (58.8%), and the success rate was higher in patients who were treated early (77.8% vs. 37.5%), but the difference was not statistically significant (p=0.092). Orbital blow-out fracture repair using porous polyethylene membrane sheets through a transconjunctival approach is a safe and effective surgical technique for orbital blow-out fracture repair. Although patients who had early surgery had a higher success rate in our study group, larger study groups are needed to assess the effect of surgical timing on success.


  • Open Access

    A Comparison of Transcanalicular, Endonasal, and External Dacryocystorhinostomy in Functional Epiphora: A Minimum Two-Year Follow-Up Study

    by Can Ozturker, Bayasgalan Purevdorj, Gamze Ozturk Karabulut, Gamal Seif, Korhan Fazil, Yasser Anwar Khan, Pelin Kaynak

    Purpose. To compare the outcomes of transcanalicular diode laser-assisted dacryocystorhinostomy (TCL-DCR), nonendoscopic endonasal dacryocystorhinostomy (NEN-DCR), and external dacryocystorhinostomy (EXT-DCR) as first-line treatments for functional epiphora. Methods. This multicenter, retrospective, case-control study included 135 eyes of 135 patients with functional epiphora (86 females and 49 males). Functional epiphora was diagnosed based on a patent lacrimal system with a delay in the fluorescein dye disappearance test (FDDT) or dacryoscintigraphy (DSG) and no ocular surface or eyelid abnormalities. The patients were treated with TCL-DCR (20082011) or Ext-DCR (20052008, 20112017) at Beyoglu Eye Research Hospital (Istanbul, Turkey) and NEN-DCR at Carrot Eye Surgery Clinic affiliated with the McMaster University (Hamilton, ON, Canada) (20102016). Success was defined as the absence of epiphora and the normalization of an earlier delayed FDDT after surgery. Results. The TCL-DCR, NEN-DCR, and EXT-DCR groups consisted of 38, 47, and 50 eyes with 25.9, 44.2, and 45.9 months of follow-up. The success rate for TCL-DCR was 65.8, 70.2 for NEN-DCR, and 84.0 for EXT-DCR. During the follow-up period, 13.2 of TCL-DCR cases and 6.4 of NEN-DCR cases developed an anatomic obstruction of the lacrimal system. Conclusion. The EXT-DCR group had a higher success rate in the management of functional epiphora than the NEN-DCR and TCL-DCR groups and was significantly safer in terms of an iatrogenic anatomic block of the lacrimal system.


  • An algorithm for Botulinum toxin A injection for upper eyelid retraction associated with thyroid eye disease: Long-term results

    by Gamze Ozturk Karabulut, Korhan Fazil, Basak Saracoglu Yilmaz, Can Ozturker, Zehra Karaağaç Günaydın, Muhittin Taskapili, Pelin Kaynak

    Dear Editor, We thank Farwana and colleagues for their response related to our publication that reiterates the potential risks of Botulinum toxin A (BTA) due to diffusion into superior rectus and o...


  • An algorithm for Botulinum toxin A injection for upper eyelid retraction associated with thyroid eye disease: long-term results

    by Gamze Ozturk Karabulut, Korhan Fazil, Basak Saracoglu Yilmaz, Can Ozturker, Zehra Karaağaç Günaydın, Muhittin Taskapili, Pelin Kaynak

    To evaluate the efficacy and complications of transconjunctival Botulinum toxin A injections performed according to an algorithm, for the management of upper eyelid retraction associated with thyro...


  • Corneal biomechanical properties in thyroid eye disease

    by Gamze Ozturk Karabulut, Pelin Kaynak, Cıgdem Altan, Can Ozturker, Ebru Funda Aksoy, Ahmet Demirok, Omer Faruk Yılmaz

    The purpose of this study is to investigate the effect of thyroid eye disease (TED) on the measurement of corneal biomechanical properties and the relationship between these parameters and disease manifestations. A total of 54 eyes of 27 individuals with TED and 52 eyes of 30 healthy control participants were enrolled. Thyroid ophthalmopathy activity was defined using the VISA (vision, inflammation, strabismus, and appearance/exposure) classification for TED. The intraocular pressure (IOP) measurement with Goldmann applanation tonometer (GAT), axial length (AL), keratometry, and central corneal thickness (CCT) measurements were taken from each patient. Corneal biomechanical properties, including corneal hysteresis (CH) and corneal resistance factor (CRF) and noncontact IOP measurements, Goldmann‐correlated IOP (IOP g ) and corneal‐compensated IOP (IOP cc ) were measured with the Ocular Response Analyzer (ORA) using the standard technique. Parameters such as best corrected visual acuity, axial length, central corneal thickness, and corneal curvature were not statistically significant between the two groups ( p > 0.05). IOP measured with GAT was higher in participants with TED ( p < 0.001). The CH of TED patients was significantly lower than that of the control group. There was no significant difference in the corneal resistance factor between groups. However, IOP g and IOP cc were significantly higher in TED patients. CH and VISA grading of TED patients showed a negative correlation ( p = 0.007). In conclusion, TED affects the corneal biomechanical properties by decreasing CH. IOP with GAT and IOPg is found to be increased in these patients. As the severity of TED increases, CH decreases in these patients.