Arsenii Trush
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Arsenii Trush has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
Stanislav Pospíšil
Institute of Theoretical and Applied Mechanics
2 shared publications- Stanislav Pospíšil
ÚTAM AV ČR, v.v.i.
2 shared publications - Hrvoje Kozmar
University of Zagreb
1 shared publication Jan Kočí
Czech Technical University
1 shared publication- Jan Kočí
Department of Materials Engineering and Chemistry, Faculty of Civil Engineering, Czech Technical University in Prague, Thákurova 7, 166 29 Prague, Czech Republic
1 shared publication - Jiří Maděra
Department of Materials Engineering and Chemistry, Faculty of Civil Engineering, Czech Technical University in Prague, Thákurova 7, 166 29 Prague, Czech Republic
1 shared publication
Latest Publications
- Open Access
Analysis of the Effect of Relative Humidity on the Convective Heat Transfer Coefficient Using Full-Scale Experiments in a Climatic Wind Tunnel
The effect of relative humidity on the convective heat exchange between a solid surface and an ambient air stream is analyzed in this study. In the experimental part, a unique closed-circuit climatic wind tunnel is utilized, allowing full-scale experiments to be conducted with full control over the environmental parameters defining the experimental boundary conditions. The experimental configuration, which includes a specific design of a specimen to promote a controlled heat flow through the specimen body, might bring new insights into the field of energy-related calculations or prediction of building energy consumption. The novelty of this work lies in the implementation of relative humidity as an independent factor within thermal modelling, which might contribute to increasing the accuracy of building energy simulation models. The computational analysis of experimental results indicates relative humidity as an important parameter, which can affect the convective heat transfer coefficient by up to 37%. The major effects have been observed after exceeding a relative humidity of 50–55%.
Open AccessAnalysis of the Effect of Relative Humidity on the Convective Heat Transfer Coefficient Using Full-Scale Experiments in a Climatic Wind Tunnel
The effect of relative humidity on the convective heat exchange between a solid surface and an ambient air stream is analyzed in this study. In the experimental part, a unique closed-circuit climatic wind tunnel is utilized, allowing full-scale experiments to be conducted with full control over the environmental parameters defining the experimental boundary conditions. The experimental configuration, which includes a specific design of a specimen to promote a controlled heat flow through the specimen body, might bring new insights into the field of energy-related calculations or prediction of building energy consumption. The novelty of this work lies in the implementation of relative humidity as an independent factor within thermal modelling, which might contribute to increasing the accuracy of building energy simulation models. The computational analysis of experimental results indicates relative humidity as an important parameter, which can affect the convective heat transfer coefficient by up to 37%. The major effects have been observed after exceeding a relative humidity of 50–55%.
- 1 October 2017
- Published by American Society of Civil Engineers (ASCE) in Journal of Bridge Engineering
- Vol. 22 (10)
Wind-Tunnel Experiments on Vortex-Induced Vibration of Rough Bridge Cables
Surface roughness, ice accretion, and atmospheric turbulence are important issues because they can considerably alter the aerodynamic characteristics of bridge cables. The present study describes wind-tunnel experiments on vortex-induced vibrations of rough bridge cables characterized with various surface roughness and performed at various levels of atmospheric turbulence. Three different cable models were used: a smooth cylinder to represent dry cables, a helical strand cable, and a cable with modeled ice accretion. The studied parameters include the critical velocity and amplitude of vortex-induced vibration and parameter sensitivity to changes in flow turbulence and cable surface roughness. The results obtained indicate that cable roughness and turbulence of the flow have significant influences on the dynamic response of bridge cables. The experimental results indicate that the vortex-induced vibration was largest for the ice-accreted bridge cable.
- 1 October 2017
- Published by American Society of Civil Engineers (ASCE) in Journal of Bridge Engineering
- Vol. 22 (10)
Wind-Tunnel Experiments on Vortex-Induced Vibration of Rough Bridge Cables
Surface roughness, ice accretion, and atmospheric turbulence are important issues because they can considerably alter the aerodynamic characteristics of bridge cables. The present study describes wind-tunnel experiments on vortex-induced vibrations of rough bridge cables characterized with various surface roughness and performed at various levels of atmospheric turbulence. Three different cable models were used: a smooth cylinder to represent dry cables, a helical strand cable, and a cable with modeled ice accretion. The studied parameters include the critical velocity and amplitude of vortex-induced vibration and parameter sensitivity to changes in flow turbulence and cable surface roughness. The results obtained indicate that cable roughness and turbulence of the flow have significant influences on the dynamic response of bridge cables. The experimental results indicate that the vortex-induced vibration was largest for the ice-accreted bridge cable.