EPEloisa Aparecida Carlesse Paloco

Eloisa Aparecida Carlesse Paloco

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Eloisa Aparecida Carlesse Paloco has a total of 29 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Effect of GSE Addition in GICs on Its Adhesion to Bovine Dentin

    by Allan Inácio Ferreira Piauilino, Sandrine Bittencourt Berger, Eloisa Aparecida Carlesse Paloco, Vitória Fraga Fogaça Melo e Silva, Murilo Baena Lopes, Delise Pellizzaro, Andreza Maria Fábio Aranha, Ricardo Danil Guiraldo

    Objectives: The aim of the present study was to evaluate microshear bond strength between bovine dentin and glass ionomer cement (GIC) modified with the addition of grape seed extract (GSE). Materials and Methods: Twenty‐four crowns of bovine incisor teeth were fixed with self‐curing acrylic resin, leaving the buccal surface of the teeth exposed. The enamel surface was removed with SiC abrasive paper, exposing the dentin. Four transparent cylindrical matrices (1 mm high and 0.75 mm in internal diameter) were placed on the dentin surfaces of each tooth. The control groups were composed of the GICs Maxxion R and the GC Gold Label 9 R used in the proportion recommended by the manufacturers. For the experimental groups, GSE was added to the GIC liquid in the form of 10% glycolic extract. The set was stored at an absolute humidity of 37°C for 24 h. After storage, matrices were removed, and specimens were submitted to the microshear bond test. Statistical Analysis: Data were submitted to two‐way ANOVA and Tukey’s test ( α = 0.05). Results: The mean bond strength values did not exhibit statistically significant differences for different groups. For the independent factor material, the average bond strength values were significantly higher for GIC GC Gold Label 9 R (6.15 MPa) when compared to Maxxion R (3.93 MPa). Conclusion: The incorporation of GSE into GIC did not negatively interfere with the adhesive properties of the GIC; the prevalence of the adhesive failure pattern was observed in all tested groups.

  • Open Access

    Effect of Amelogenin Solution in the Microhardness of Remineralized Enamel and Shear Bond Strength of Orthodontic Brackets

    by Guilherme Genovez-Júnior, Sandrine Bittencourt Berger, Lucineide Lima dos Santos, Eloisa Aparecida Carlesse Paloco, Murilo Baena Lopes, Débora Fernandes Giuliangeli, Júlia Graciela Monteiro dos Santos, Ricardo Danil Guiraldo

    Objectives. To evaluate the microhardness of tooth enamel remineralized with enamel matrix protein solution as well as the shear bond strength of orthodontic brackets bonded to this surface. Materials and Methods. In total, 24 human premolars were selected and divided into 3 experimental groups (n=8): SEsound enamel, DEdemineralized enamel, and TEdemineralized enamel treated with amelogenin solution. Samples from DE and TE groups were subjected to pH cycling to induce initial artificial caries lesion. TE group was treated with amelogenin solution. Samples were placed in artificial saliva for 7 days. Knoop microhardness was measured before any intervention (T0), after pH cycling (T1) and after amelogenin solution treatment application (T2). Twenty-four hours after ceramic orthodontic brackets were bonded, samples were subjected to shear test in a universal testing machine. Microhardness and shear measurement distributions were subjected to KolmogorovSmirnov normality test, which was followed by parametric tests (α=0.05): 2-way analysis of variance (factors: enamel condition×treatment) and Tukey posttest for all three groups (SE, DE, and TE) in T0 and T2 for microhardness; analysis of variance and Tukeys test, for shear bond strength test. Results. Means recorded for Knoop microhardness in T2, for the SE (366.7 KHN) and TE (342.8 KHN) groups, were significantly higher than those recorded for the DE group (263.5 KHN). The shear bond strength of the SE (15.44MPa) and TE (14.84MPa) groups statistically differed from that of the DE group (11.95MPa). Conclusion. In vitro demineralized enamel treatment with amelogenin solution was capable of taking samples hardness back to levels similar to those observed for sound enamel. The shear bond strength on the enamel subjected to this treatment was similar to that observed for healthy enamel and higher than that observed for demineralized enamel.


  • Open Access

    Evaluation of enamel roughness after the removal of brackets bonded with different materials: In vivo study

    by Rodrigo Vieira Caixeta, Sandrine Bittencourt Berger, Murilo Baena Lopes, Eloisa Aparecida Carlesse Paloco, Élcio Mário Faria-Júnior, Edwin Fernando Ruiz Contreras, Alcides Gonini-Júnior, Ricardo Danil Guiraldo

    The aims of this in vivo study were to evaluate the effect of bonding with resin-modified glass ionomer cement (RMGIC) and to assess enamel surface roughness before and after the removal of brackets bonded with composite or RMGIC from the maxillary central incisors. Fifteen orthodontic patients were selected for the study. For each patient, the teeth were rinsed and dried, and brackets were bonded with composite (Transbond XT) and RMGIC (Vitremer Core Buildup/Restorative). At the conclusion of orthodontic treatment, their brackets were removed. Dental replicas were made of epoxy resin in initial conditions (before bonded) and after polishing with an aluminum oxide disc system. Adhesive remnant index (ARI) and surface roughness was measured on the dental replicas and data were evaluated statistically by Mann-Whitney and paired t-test, respectively. No bracket debonding occurred during patients’ treatment periods. It was verified that the ARI values of the two maxillary central incisors were similar (p = 0.665). For both bonding materials, the ARI value of 3 was predominant. After polishing, surface roughness was similar in the composite and RMGIC groups (0.245 μm and 0.248 μm, respectively; p = 0.07). In both groups, enamel surface roughness values were significantly lower after polishing compared with the initial condition (p < 0.001). RMGIC promoted efficiency in cementing brackets without fail during treatment; the choice of composite or RMGIC materials was not a factor that influenced the roughness of the enamel surface, however, polishing led to smoother surfaces than those found at the beginning of the treatment.


  • Open Access

    Procedimentos Restauradores e Cuidados com a Saúde Bucal em Indivíduos com Fissura Lábio-Palatina

    by Ricardo Danil Guiraldo, Sandrine Bittencourt Berger, Mateus Rodrigues Tonetto, Eloisa Aparecida Carlesse Paloco, Allan Inácio Ferreira Piauilino, Arilson Nunes Ferreira De Matos, Andrei Rosa, Thais Maria Freire Fernandes

    Fissura labial e/ou palatina é a forma congênita mais frequente anomalia ocorrendo na região craniofacial, as quais são defeitos orofaciais inatos não sindrômicos, que incluem uma variedade de doenças que afetam a face e a cavidade bucal. O objetivo neste estudo foi realizar um artigo técnico visando esclarecer os procedimentos restauradores e cuidados com a saúde bucal em indivíduos com fissura lábio-palatina. Crianças com fissura lábio-palatina apresentam significativo risco de cárie nos incisivos decíduos, além disso, têm mais superfícies cariadas/restauradas na dentição decídua do que crianças não fissuradas. Assim, deve-se promover o ensinamento de técnicas de higiene bucal para controle desta. Procedimentos restauradores, assim como tratamentos endodônticos são realizados em pacientes com fissura lábio-palatina assim como em pacientes sem fissuras. Para realização dos tratamentos dentários convencionais nas crianças com fissura não tratadas cirurgicamente, o uso de isolamento absoluto tem uma especial importância, pois previne o desconforto causado pelo fluxo constante de água dos instrumentos rotativos e pela presença de resíduos de materiais que podem entrar nas vias aéreas e serem aspirados e/ou deglutidos. Portanto, procedimentos restauradores devem ser realizados em indivíduos com fissura lábio-palatina similarmente a indivíduos que não tenham fissura, entretanto, cuidados tais como isolamento absoluto devem ser tomados e a prevenção é fator fundamental nestes indivíduos. Palavras-chaves: Fenda Labial. Fissura Palatina. Cárie Dentária. Reparação de Restauração Dentária. Abstract Cleft lip and / or palate is the most common congenital anomaly occurring in the craniofacial region, which are non-syndromic inborn orofacial defects, which include a variety of diseases that affect the face and oral cavity. The objective of this study was to carry out a technical article to clarify the restorative procedures and oral health care in individuals with cleft lip and palate. Children with cleft lip and palate have a significant risk of caries in the primary incisors, in addition, they have more decayed/restored surfaces in the primary dentition than non-cleft children. Thus, the teaching of oral hygiene techniques to control it should be promoted. Restorative procedures, as well as endodontic treatments are performed in patients with cleft lip and palate as well as in patients without clefts. To perform conventional dental treatments on children with cleft not treated surgically, the use of absolute isolation is of special importance, as it prevents discomfort caused by the constant water flow from rotating instruments and the presence of material residues that may enter the airways and be aspirated and/or swallowed. Therefore, restorative procedures must be performed in individuals with cleft lip and palate similarly to individuals who do not have cleft, however, care such as absolute isolation must be taken, and prevention is a fundamental factor in these individuals. Keywords: Cleft Lip. Cleft Palate. Dental Carie. Dental Cavity. Dental Restoration Repair.

  • Open Access

    Effect of Protein-Based Treatment on Chemical Composition, Hardness and Bond Strength of Remineralized Enamel

    by Guilherme Genovez-Júnior, Eloisa Aparecida Carlesse Paloco, Sandrine Bittencourt Berger, Alejandra Hortencia Miranda González, Murilo Baena Lopes, Daniele Cristina Amânicio, Ricardo Danil Guiraldo

    This study evaluated the chemical composition and microhardness of human enamel treated with an Enamel Matrix Derivative (EMD) solution, and the bond strength between composite resin and this enamel. Thirty human enamel samples were randomly divided into three groups: Untouched Enamel (UE), Demineralized Enamel (DE) and Demineralized Enamel Treated with EMD (ET). DE and ET groups were subjected to acid challenge and ET treated with EMD (EMD was directly applied over conditioned enamel and left for 15 min). Samples from each group (n=4) had chemical composition assessed through to attenuated total reflectance Fourier transform infrared (ATR-FTIR). Knoop microhardness of enamel samples from each group (n=10) was measured. For the microshear bond strength, the samples were etched for 30 s, and the adhesive was applied and cured for 10 s. Two matrixes were placed on the samples, filled with Filtek Z350 XT composite and cured for 20 s, each. The matrix was removed, and the microshear bond strength of each group (n=10) was tested. Data were subjected to Kruskal-Wallis test (for microhardness), to analysis of variance and to Tukey’s test (for microshear bond strength); (α=0.05). FTIR results have shown phosphate (hydroxyapatite indicator) in 900-1200 cm-1 bands in the UE and ET groups, which were different from the DE group. Microhardness and microshear analyses recorded higher statistical values for the UE and ET groups than for DE. EMD application to demineralized enamel seems to have remineralized the enamel; thus, the microhardness and bond strength was similar between UE and ET groups.


  • Open Access

    Avaliação da rugosidade de fios de NiTi quando expostos à solução fluoretada

    by Lucineide Lima dos Santos, Eloisa Aparecida Carlesse Paloco, Sandrine Bittencourt Berger, Flaviana Alves Dias, Débora Fernandes Giuliangeli, Júlia Graciela Monteiro dos Santos, Lucia Gloria Diana Aguilar Pizzurno, Ricardo Danil Guiraldo

    There is a concern about the nickel-titanium (NiTi-)-based wires due their content and potential release of nickel, mainly when they are exposed to fluoride. Therefore, the aim of this study was to evaluate the roughness of NiTi-based wires used in orthodontic treatment when exposed to fluoridated solution. The wires were divided in groups according their composition (Flexy NiTi Super Elastic, Flexy NiTi Thermal 35°, Flexy NiTi Copper e Flexy Blue-Ti), time (0 day – T0, 7 days – T1, 14 days – T2, and 28 days – T3) and immersion (artificial saliva solution or artificial saliva containing fluoride). To the roughness assay, straight sections (24 mm) of each wire were used, under constant speed of 0.25 mm/s, measurement length of 2.5 mm and cut-off value of 0.25 mm. The value of surface roughness was obtained by the average of three measurements of each wire. To check data normality the Kolmogorov-Smirnov test was applied, followed by analysis of variance to compare the difference between time and Student t-test to compare the difference of time to each group and intergroup. There was no statistically significant difference of the roughness intra- and intergroup between different composition, time nor immersion. The use of 0.2% fluoride once a week did not cause significant changes in the surface characteristics of studied wires.


  • Open Access

    Influência da data de validade na estabilidade dimensional dos elastômeros

    by Ricardo Danil Guiraldo, Sandrine Bittencourt Berger, Eloisa Aparecida Carlesse Paloco, Alexandre dos Reis Freitas, Murilo Baena Lopes, Rodrigo Ribeiro de Carvalho, Gabriela Fleury Seixas, Mário Alexandre Coelho Sinhoreti

    Os materiais de impressão são utilizados na confecção de modelos em diferentes áreas da odontologia, com ênfase na reabilitação oral com próteses fixas e removíveis ou dentaduras. O objetivo foi comparar a estabilidade dimensional de impressões baseadas em elastômeros de polivinilsiloxano (Express) e poliéter (Impregum Soft) realizadas 2 anos após sua data de validade com impressões que não ultrapassaram esse período. As impressões foram realizadas sobre matriz com moldeira metálica; eles foram removidos após a polimerização e divididos em 4 grupos (n = 5). A estabilidade dimensional foi avaliada por microscopia óptica na linha de 20 µm com comprimento de 25 mm (padrão ISO 4823). Os valores de estabilidade dimensional (%) foram submetidos a ANOVA two-way (material x data de validade) e teste de Tukey (α = 0,05). Com base na análise da data de validade como fator independente (p = 0,017), os valores médios de estabilidade dimensional registrados para a impressão de elastômero 2 anos após a data de expiração (99,89%) foram estatisticamente inferiores aos valores registrados para o não expirado (99,92%) As alterações decorrentes do uso dos elastômeros 2 anos após o seu vencimento não afetam a estabilidade dimensional das próteses decorrentes dessas impressões.

  • Open Access

    Does Pigment Incorporation into Regular Composite Resins for Posterior Buildups Alter Their Bond Strength?

    by Flaviana Alves Dias, Maria Verônica Rodrigues Conto, Ricardo Danil Guiraldo, Omar Geha, Eloisa Aparecida Carlesse Paloco, Thais Maria Freire Fernandes, Sandrine Bittencourt Berger

    Posterior build-ups are auxiliary devices to orthodontic treatment which are made with resin-based or glass ionomer composites. Their removal requires care to protect the tooth surface, therefore, pigmented materials are preferred for a better visualization. This study proposed a pigmentation experimental technique of a regular composite resin, evaluating the microshear bond strength test (µ-SBT) of this experimental pigmented resin and comparing with a blue-colored polyacid-modified composite resin, used for posterior buildups. Forty-eight buccal and lingual surfaces of human teeth were used and randomly divided into 4 groups (n=12). The groups were divided into: C (control), regular composite resin; P, regular composite resin pigmented; UBL, Ultra Band Lok™; OB, Ortho Bite™. The composites were bonded using a matrix to obtain microcylinders and prepared for each experimental groups. The samples were then stored in distilled water for 24h at 37°C followed by a µ-SBT. The types of bond failures were evaluated using a stereoscopic magnifying glass (10×). The data were analyzed by ANOVA with Fisher post hoc and Dunnett´s test. Means of µ-SBT± standard deviation (MPa) were: C (39.98a±13.0), P (40.09a± 14.3); UBL (33.26ab±8.6); OB (28.70b±5.5). The most prevalent type of failure was adhesive (80.4%). Further, was not observed a statistically significant correlation between the bond strength values and failure patterns. The pigmentation of a commercially available resin did not alter the µ-SBT and exhibited similar adhesiveness as a polyacid-modified composite resin.