AGAmit Goyal

Amit Goyal

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Amit Goyal has a total of 257 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Electrode–Modiolar Distance as a Determinant of Cochlear Implant Performance: A Systematic Review and Meta‐Analysis

    by Nidhin Das K, Vidhu Sharma, Siddharth Manoj, Amit Goyal

    Objective: To quantify the relationship between electrode–modiolar distance (EMD) and cochlear implant (CI) performance across speech/perceptual, electrophysiological and programming outcomes and to characterize the dose–response effect of EMD. Methods: A systematic search of PubMed/MEDLINE, Embase, Scopus, Web of Science and Cochrane CENTRAL was conducted in accordance with PRISMA guidelines. Human studies reporting CT‐ or CBCT‐derived EMD and CI outcomes were included. Effect sizes were transformed to odds ratios (ORs) and pooled using random‐effects models. Subgroup, sensitivity and dose–response analyses were performed. Heterogeneity was assessed using I 2 , and publication bias was evaluated using funnel plots and Egger's test. Results: Twenty‐one studies comprising approximately 1181 implanted ears were included. Reduced EMD was associated with significantly higher odds of favourable CI outcomes (pooled OR = 2.16, 95% CI: 1.89–2.45; p < 0.001; I 2 = 0%). Consistent effects were observed for speech/perceptual outcomes (OR = 2.23), electrophysiological measures (OR = 2.80 after sensitivity adjustment) and programming parameters (OR = 1.72). Dose–response modelling demonstrated a monotonic gradient, with each 1 mm increase in EMD associated with a 20%–30% reduction in the odds of favourable outcomes (OR per mm ≈0.72; p < 0.001). No significant publication bias was detected (Egger's p = 0.056). Conclusion: Electrode–modiolar proximity is a strong and consistent determinant of CI performance with a clear dose–response relationship, supporting its role as a clinically actionable imaging biomarker for optimizing electrode selection, surgical strategy and individualized programming. Trial Registration: PROSPERO: CRD420261380236

  • Outcomes of anatomy based planning in cochlear implantation: a meta-analysis of advancing precision otologic medicine

    by Nidhin Das K., Vidhu Sharma, Amit Goyal

    Objective To evaluate the impact of anatomy-based planning (ABP) and individualized electrode array selection on cochlear implant outcomes, and to compare the effectiveness of precision-guided approaches versus conventional clinician-driven programming strategies. Data sources Systematic searches of PubMed, Web of Science, Scopus, and Embase were conducted for studies published between January 2000 and June 2025. Review methods This meta-analysis followed PRISMA 2020 guidelines. Eleven studies involving 291 post-lingually deafened adults were included. Only studies utilizing anatomy-based planning tools with quantifiable auditory and speech outcomes were analyzed. Data synthesis was performed using a fixed-effects model, and subgroup analyses were conducted based on surgical approach and outcome type. Results All included studies demonstrated superior outcomes with ABP compared to conventional planning, with odds ratios ranging from 1.5 to 7.0. Pooled analysis revealed significant benefits in both speech-related (OR = 1.93, 95% CI: 1.56–2.40) and auditory/music-related outcomes (OR = 2.38, 95% CI: 1.98–2.86). Subgroup analysis confirmed consistent advantages of ABP across both round window and cochleostomy approaches. No study reported adverse intraoperative events directly attributable to ABP. Individualized electrode array selection based on cochlear duct length and angular insertion depth improved frequency-place alignment and auditory perception. Conclusion Anatomy-based planning significantly enhances cochlear implantation outcomes by optimizing electrode positioning, minimizing frequency-place mismatch, and improving speech and auditory performance. The integration of precision imaging and individualized planning tools represents a promising step toward personalized otologic surgery. Level of evidence Level III (Meta-analysis of non-randomized and randomized controlled trials).

  • Unburdening the Heart: Structural and Functional Cardiac Changes Post Parathyroidectomy for Primary Hyperparathyroidism

    by B. Sathishkumar, Siddharth Manoj, Vidhu Sharma, Madhukar Mittal, Ravindra Kumar Shukla, Surender Deora, Bikram Choudhury, Amit Goyal, Kapil Soni

  • Factors influencing outcomes in endoscopic management of post intubation tracheal stenosis with montgomery t tube placement

    by Siddharth Manoj, Vidhu Sharma, Rishabh Mehta, Nidhin Das K., Rashmi Hansdah, Kapil Soni, Bikram Choudhury, Amit Goyal

    Background Post-intubation tracheal stenosis (PITS) is a common late complication of prolonged endotracheal intubation or tracheostomy, leading to progressive airway obstruction. Endoscopic management with Montgomery T-tube placement provides a less invasive alternative to tracheal resection. This study evaluates clinical factors influencing outcomes following endoscopic treatment with T-tube stenting. Methodology A retrospective chart review was conducted on patients with PITS managed at the Department of Otorhinolaryngology, AIIMS Jodhpur, between January 2019 and December 2023. Patients undergoing endoscopic management followed by Montgomery T-tube insertion, and completing at least 6 months postdecannulation follow-up, were included. Pre-operative assessment included Fibreoptic Laryngoscopy, CT imaging, and voice evaluation (VHI-10 and VRQOL). Outcome measures included need for repeated interventions, successful decannulation, and voice improvement. Results Of 27 patients who underwent T-tube placement, 18 met the inclusion criteria of complete follow-up, 17 achieved successful decannulation and formed the final study cohort. Nine of these (52%) required repeated procedures. Significant predictors for repeated interventions were length of stenosis (p < 0.001) and percentage of stenosis (p = 0.01). ROC analysis showed high predictive ability for stenosis length (AUC 0.889) and percentage (AUC 0.819), with cut-off values of >17 mm and >72.5% respectively. Voice outcomes significantly improved at 6 months postdecannulation (p < 0.001). Conclusion Endoscopic management with Montgomery T-tube provides effective airway restoration and voice improvement in PITS. Stenosis length and severity are key predictors of the need for repeat interventions. Proper patient counselling, compliance, and careful consideration are essential for favourable outcomes.


  • Hearing Status Amongst Medical Trainees Using Personal Listening Devices - A Concern or an Overlooked Hazard to Hearing Health?

    by Siddharth Manoj, Bikram Choudhury, Swathi Krishna, Rashmi Hansdah, Vidhu Sharma, Kapil Soni, Amit Goyal

    Objectives: Increased use of personal listening devices such as headphones and earphones can lead to noise-induced hearing loss, especially with prolonged use and high volume. This study aimed to assess hearing status among medical trainees and its relationship with unsafe personal listening device usage. Methods: Cross-sectional study was conducted among 177 medical trainees at a medical college in Western Rajasthan. An online questionnaire assessed personal listening device usage patterns, and hearing status was evaluated. Results: Most preferred in-the-ear personal listening devices (78 per cent) at moderately loud volume (61.6 per cent) for more than 1 hour daily (58.2 per cent). Although 54.2 per cent reported slight hearing loss in at least one ear, no significant association was found between hearing loss and personal listening device type, volume or duration. However, hearing loss was significantly higher in males than females. Conclusion: Contrary to earlier studies, no significant relationship was observed between personal listening device usage patterns and hearing loss, highlighting the need for larger studies using standardised sound exposure assessments.

  • Assessment of effectiveness of cantilever versus spreader grafts in functional septorhinoplasty: an interventional cohort study

    by Shruthi Gs, Kapil Soni, Swathi Krishna M, Vidhu Sharma, Bikram Choudhury, Amit Goyal, Ullas Raghavan

    Objectives: This study aims to compare the effectiveness of the spreader grafts and cantilever grafts in correcting the narrow internal nasal valve in patients undergoing functional septorhinoplasty. Methods: This ambispective interventional cohort study, involving 50 patients who underwent septorhinoplasty between December 2020 and November 2023 at our tertiary-care referral hospital, with 25 receiving spreader grafts (control group) and 25 undergoing surgery with cantilever grafts. Results: The results showed a significant improvement in nasal airflow in both groups post-operatively, with the cantilever graft group showing a slightly higher improvement than the spreader graft group, although not statistically significant ( p = 0.062). Conclusions: Septorhinoplasty is a surgical procedure that aims to improve both the aesthetic appearance of the nose and nasal function. While spreader grafts are considered a standard technique for aesthetic improvement, the balanced cantilever graft offers a promising alternative for functional enhancement, particularly in patients with a narrow internal nasal valve.

  • Open Access

    Skull base defects: outcomes and reconstruction from a tertiary center in India

    by Palak Gupta, Srinivas Chadaram, Vidhu Sharma, Kapil Soni, Bikram Choudhury, Amit Goyal

    Background: Skull base defects, accidental or planned during tumor resections, present significant reconstructive challenges. Effective repair prevents cerebrospinal fluid (CSF) leaks, meningitis, and pneumocephalus.Methods: This retrospective observational study analyzed 26 patients with anterior or lateral skull base defects treated between 2018 and 2024 at a tertiary care center in Western India. Both planned iatrogenic and accidental intraoperative defects were included. Patient demographics, surgical approach, defect characteristics, reconstruction techniques, and postoperative outcomes were recorded. All patients underwent multilayered repair with tailored perioperative management, including selective lumbar drainage.Results: Among 26 patients, 14 (53.8%) had anterior and 12 (46.2%) had lateral skull base defects. Intraoperative CSF leak occurred in 11 patients (42.3%). Defects were repaired using combinations of autologous tissue (fat, fascia lata, muscle), allogenic grafts (DuraGen), and vascularized flaps. Seven patients (26.9%) required lumbar drains. All reconstructions were successful with no secondary failures. However, two major complications were observed: one case of pneumocephalus and one of postoperative vision loss following ossifying fibroma excision. No postoperative meningitis or recurrent CSF leaks were noted.Conclusion: Meticulous multilayered repair strategies and structured perioperative protocols provide excellent outcomes in skull base defect reconstruction. Differentiating between planned and accidental iatrogenic defects allows for better preoperative planning and individualized management. Despite a 100% repair success rate, rare but serious complications such as vision loss highlight the need for careful surgical technique near critical neurovascular structures.

  • Unveiling the impact of dengue fever on hearing health: a case control study

    by Kapil Soni, Yash Agrawal, Swathi Krishna M, Gopal Bohra, Amit Goyal, Vidhu Sharma

    Background: Dengue fever, a mosquito-borne viral illness, has varied systemic manifestations, but its auditory effects remain underexplored. The objective of this study was to assess the association between dengue infection and hearing loss. Methods: A prospective case-control study was conducted on 79 patients—40 dengue-positive (NS1 antigen confirmed) and 39 with other febrile illnesses. All participants underwent otological examination and pure tone audiometry. Results: Hearing loss was observed in 15.2 per cent of dengue patients, with none in controls ( p < 0.001). The odds ratio for hearing loss in dengue was 34.6 (95 per cent confidence interval: 1.97–610). Dengue patients exhibited significantly elevated air and bone conduction thresholds ( p < 0.001). Lower platelet counts and higher C-reactive protein levels correlated with hearing loss, suggesting vascular and inflammatory mechanisms. Conclusion: Dengue fever may be associated with reversible sensorineural hearing loss, likely due to microvascular and inflammatory injury to the cochlea. Early audiological screening is recommended in dengue cases.