Andres Vega
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Andres Vega has a total of 30 co-authors. Here are the top co-authors by number of shared publications:
Thomas Pertsch
Institute of Applied Physics Abbe Center of Photonics Friedrich Schiller University Jena Albert-Einstein-Str. 15 07745 Jena Germany
8 shared publicationsFrank Setzpfandt
Institute of Applied Physics Abbe Center of Photonics Friedrich Schiller University Jena Albert-Einstein-Str. 15 07745 Jena Germany
7 shared publications- Frank Setzpfandt
Institute of Applied Physics, Abbe Center of Photonics, Friedrich Schiller University Jena 1 , Albert-Einstein-Straße 15, 07745 Jena
4 shared publications Sina Saravi
Institute of Applied Physics Abbe Center of Photonics Friedrich Schiller University Jena Albert-Einstein-Str. 15 07745 Jena Germany
4 shared publications- Andrey A.. Sukhorukov
Australian National University
3 shared publications - Elkin A. Santos
Institute of Applied Physics Abbe Center of Photonics Friedrich Schiller University Jena Albert-Einstein-Str. 15 07745 Jena Germany
3 shared publications
Latest Publications
- Open Access
- 1 April 2024
- Published by AIP Publishing in APL Photonics
- Vol. 9 (4)
Nonlocal quantum differentiation between polarization objects using entanglement
For a wide range of applications, a fast, non-destructive, remote, and sensitive identification of samples with predefined characteristics is preferred instead of their full characterization. In this work, we report on the experimental implementation of a nonlocal quantum measurement scheme, which allows for differentiation among samples out of a predefined set of transparent and birefringent objects in a distant optical channel. The measurement is enabled by application of polarization-entangled photon pairs and is based on remote state preparation. On an example set of more than 80 objects characterized by different Mueller matrices, we show that only two coincidence measurements are already sufficient for successful discrimination. The number of measurements needed for sample differentiation is significantly decreased compared to a comprehensive polarimetric analysis. Our results demonstrate the potential of this polarization detection method for polarimetric applications in biomedical diagnostics, remote sensing, and other classification/detection tasks.
- 1 April 2024
- Published by AIP Publishing in APL Photonics
- Vol. 9 (4)
Open AccessNonlocal quantum differentiation between polarization objects using entanglement
For a wide range of applications, a fast, non-destructive, remote, and sensitive identification of samples with predefined characteristics is preferred instead of their full characterization. In this work, we report on the experimental implementation of a nonlocal quantum measurement scheme, which allows for differentiation among samples out of a predefined set of transparent and birefringent objects in a distant optical channel. The measurement is enabled by application of polarization-entangled photon pairs and is based on remote state preparation. On an example set of more than 80 objects characterized by different Mueller matrices, we show that only two coincidence measurements are already sufficient for successful discrimination. The number of measurements needed for sample differentiation is significantly decreased compared to a comprehensive polarimetric analysis. Our results demonstrate the potential of this polarization detection method for polarimetric applications in biomedical diagnostics, remote sensing, and other classification/detection tasks.
- 20 November 2023
- Published by American Physical Society (APS) in Physical Review A
- Vol. 108 (5) , 052610
Experimental analysis of image resolution of quantum imaging with undetected light through position correlations
Image resolution of quantum imaging with undetected photons is governed by the spatial correlations existing between the photons of a photon pair that has been generated in a nonlinear process. These correlations allow for obtaining an image of an object with light that never interacted with that object. Depending on the imaging configuration, either position or momentum correlations are exploited. We hereby experimentally analyze how the crystal length and pump waist affect the image resolution when using position correlations of photons that have been generated via spontaneous parametric down conversion in a nonlinear interferometer. Our results support existing theoretical models for the dependency of the resolution on the crystal length. In addition, we probe the resolution of our quantum imaging scheme for varying pump waists over one order of magnitude. This analysis reveals the intricate dependency of the resolution on the strength of the correlations within the biphoton states for parameter combinations in which the crystal lengths are much larger than the involved photon wavelengths. We extend the existing models in this parameter regime to properly take nontrivial effects of finite pump waists into account and demonstrate that they match the experimental results.
- 20 November 2023
- Published by American Physical Society (APS) in Physical Review A
- Vol. 108 (5) , 052610
Experimental analysis of image resolution of quantum imaging with undetected light through position correlations
Image resolution of quantum imaging with undetected photons is governed by the spatial correlations existing between the photons of a photon pair that has been generated in a nonlinear process. These correlations allow for obtaining an image of an object with light that never interacted with that object. Depending on the imaging configuration, either position or momentum correlations are exploited. We hereby experimentally analyze how the crystal length and pump waist affect the image resolution when using position correlations of photons that have been generated via spontaneous parametric down conversion in a nonlinear interferometer. Our results support existing theoretical models for the dependency of the resolution on the crystal length. In addition, we probe the resolution of our quantum imaging scheme for varying pump waists over one order of magnitude. This analysis reveals the intricate dependency of the resolution on the strength of the correlations within the biphoton states for parameter combinations in which the crystal lengths are much larger than the involved photon wavelengths. We extend the existing models in this parameter regime to properly take nontrivial effects of finite pump waists into account and demonstrate that they match the experimental results.
- Open Access
Pinhole quantum ghost imaging
We propose a quantum ghost imaging scheme based on biphotons, that, by using a collimated pump beam of the right size for biphoton generation, obviates the need for lenses to achieve imaging. The scheme is found to be analogous to the classical pinhole camera, where we show that the equivalent to the classical pinhole size depends mainly on the width of the pump beam, but also on the thickness of the nonlinear crystal and the wavelengths of the biphoton.
Open AccessPinhole quantum ghost imaging
We propose a quantum ghost imaging scheme based on biphotons, that, by using a collimated pump beam of the right size for biphoton generation, obviates the need for lenses to achieve imaging. The scheme is found to be analogous to the classical pinhole camera, where we show that the equivalent to the classical pinhole size depends mainly on the width of the pump beam, but also on the thickness of the nonlinear crystal and the wavelengths of the biphoton.
- Open Access
- 30 September 2022
- Published by American Physical Society (APS) in Physical Review Research
- Vol. 4 (3) , 033252
Fundamental resolution limit of quantum imaging with undetected photons
Quantum imaging with undetected photons relies on the principle of induced coherence without induced emission and uses two sources of photon pairs with a signal- and an idler photon. Each pair shares strong quantum correlations in both position and momentum, which allows us to image an object illuminated with idler photons by just measuring signal photons that never interact with the object. In this work, we theoretically investigate the transverse resolution of this nonlocal imaging scheme through a general formalism that treats propagating photons beyond the commonly used paraxial approximation. We hereby prove that the resolution of quantum imaging with undetected photons is fundamentally diffraction limited to the longer wavelength of the signal and idler pairs. Moreover, we conclude that this result is also valid for other nonlocal two-photon imaging schemes.
- 30 September 2022
- Published by American Physical Society (APS) in Physical Review Research
- Vol. 4 (3) , 033252
Open AccessFundamental resolution limit of quantum imaging with undetected photons
Quantum imaging with undetected photons relies on the principle of induced coherence without induced emission and uses two sources of photon pairs with a signal- and an idler photon. Each pair shares strong quantum correlations in both position and momentum, which allows us to image an object illuminated with idler photons by just measuring signal photons that never interact with the object. In this work, we theoretically investigate the transverse resolution of this nonlocal imaging scheme through a general formalism that treats propagating photons beyond the commonly used paraxial approximation. We hereby prove that the resolution of quantum imaging with undetected photons is fundamentally diffraction limited to the longer wavelength of the signal and idler pairs. Moreover, we conclude that this result is also valid for other nonlocal two-photon imaging schemes.
- Open Access
Fundamental resolution limit of quantum imaging with undetected photons
Quantum imaging with undetected photons relies on the principle of induced coherence without induced emission and uses two sources of photon-pairs with a signal- and an idler photon. Each pair shares strong quantum correlations in both position and momentum, which allows to image an object illuminated with idler photons by just measuring signal photons that never interact with the object. In this work, we theoretically investigate the transverse resolution of this non-local imaging scheme through a general formalism that treats propagating photons beyond the commonly used paraxial approximation. We hereby prove that the resolution of quantum imaging with undetected photons is fundamentally diffraction limited to the longer wavelength of the signal and idler pairs. Moreover, we conclude that this result is also valid for other non-local two-photon imaging schemes.
Open AccessFundamental resolution limit of quantum imaging with undetected photons
Quantum imaging with undetected photons relies on the principle of induced coherence without induced emission and uses two sources of photon-pairs with a signal- and an idler photon. Each pair shares strong quantum correlations in both position and momentum, which allows to image an object illuminated with idler photons by just measuring signal photons that never interact with the object. In this work, we theoretically investigate the transverse resolution of this non-local imaging scheme through a general formalism that treats propagating photons beyond the commonly used paraxial approximation. We hereby prove that the resolution of quantum imaging with undetected photons is fundamentally diffraction limited to the longer wavelength of the signal and idler pairs. Moreover, we conclude that this result is also valid for other non-local two-photon imaging schemes.
- 13 December 2021
- Published by AIP Publishing in Applied Physics Letters
- Vol. 119 (24) , 244001
Mid-infrared photon pair generation in AgGaS2
We demonstrate nondegenerate photon pair generation by spontaneous parametric downconversion in a silver gallium sulfide AgGaS2 crystal. By tuning the pump wavelength, we achieve phase matching over a large spectral range. This allows to generate idler photons in the mid-infrared spectral range above a 6 μm wavelength with corresponding signal photons in the visible. Also, we show photon pair generation with broad spectral bandwidth. These results are a valuable step toward the development of quantum imaging and sensing techniques in the mid-infrared.
- 13 December 2021
- Published by AIP Publishing in Applied Physics Letters
- Vol. 119 (24) , 244001
Mid-infrared photon pair generation in AgGaS2
We demonstrate nondegenerate photon pair generation by spontaneous parametric downconversion in a silver gallium sulfide AgGaS2 crystal. By tuning the pump wavelength, we achieve phase matching over a large spectral range. This allows to generate idler photons in the mid-infrared spectral range above a 6 μm wavelength with corresponding signal photons in the visible. Also, we show photon pair generation with broad spectral bandwidth. These results are a valuable step toward the development of quantum imaging and sensing techniques in the mid-infrared.
- 13 December 2021
- Published by American Physical Society (APS) in Physical Review Applied
- Vol. 16 (6) , 064032
Metasurface-Assisted Quantum Ghost Discrimination of Polarization Objects
We develop a concept of metasurface-assisted ghost imaging for nonlocal discrimination between a set of polarization objects. The specially designed metasurfaces are incorporated in the imaging system to perform parallel state transformations in general elliptical bases of quantum-entangled or classically correlated photons. Then, only four or fewer correlation measurements between multiple metasurface outputs and a simple polarization-insensitive bucket detector after the object can allow for the identification of fully or partially transparent polarization elements and their arbitrary orientation angles. The approach can find applications for real-time and low-light imaging across diverse spectral regions in dynamic environments.
- 13 December 2021
- Published by American Physical Society (APS) in Physical Review Applied
- Vol. 16 (6) , 064032
Metasurface-Assisted Quantum Ghost Discrimination of Polarization Objects
We develop a concept of metasurface-assisted ghost imaging for nonlocal discrimination between a set of polarization objects. The specially designed metasurfaces are incorporated in the imaging system to perform parallel state transformations in general elliptical bases of quantum-entangled or classically correlated photons. Then, only four or fewer correlation measurements between multiple metasurface outputs and a simple polarization-insensitive bucket detector after the object can allow for the identification of fully or partially transparent polarization elements and their arbitrary orientation angles. The approach can find applications for real-time and low-light imaging across diverse spectral regions in dynamic environments.
- 1 January 2021
- Published by Optica Publishing Group
- p. Th4A.4
Resolution of two-color quantum imaging with undetected photons
We analyze the diffraction-limited resolution of quantum imaging with un-detected photons with non-degenerate photon-pairs. We find that the resolution is half of the longest of both wavelengths and is achieved using sources with sub-wavelength thicknesses.
- 1 January 2021
- Published by Optica Publishing Group
- p. Th4A.4
Resolution of two-color quantum imaging with undetected photons
We analyze the diffraction-limited resolution of quantum imaging with un-detected photons with non-degenerate photon-pairs. We find that the resolution is half of the longest of both wavelengths and is achieved using sources with sub-wavelength thicknesses.
- 31 August 2020
- Published by AIP Publishing in Applied Physics Letters
- Vol. 117 (9) , 094003
Pinhole quantum ghost imaging
We propose a quantum ghost imaging scheme based on biphotons, which, by using a collimated pump beam of the right size for biphoton generation, obviates the need for lenses to achieve imaging. The scheme is found to be analogous to the classical pinhole camera, where we show that the equivalent to the classical pinhole size depends not only mainly on the width of the pump beam but also on the thickness of the nonlinear crystal and the wavelengths of the biphoton.
- 31 August 2020
- Published by AIP Publishing in Applied Physics Letters
- Vol. 117 (9) , 094003
Pinhole quantum ghost imaging
We propose a quantum ghost imaging scheme based on biphotons, which, by using a collimated pump beam of the right size for biphoton generation, obviates the need for lenses to achieve imaging. The scheme is found to be analogous to the classical pinhole camera, where we show that the equivalent to the classical pinhole size depends not only mainly on the width of the pump beam but also on the thickness of the nonlinear crystal and the wavelengths of the biphoton.
- 1 January 2020
- Published by Optica Publishing Group
- p. FM1C.7
Discerning Polarization Objects using Non-local Measurements with Metasurfaces
We present an original non-local ghost measurement scheme with polarization-entangled photons, where nanostructured dielectric metasurfaces enable discrimination between a set of objects with different polarization characteristics, including fully or partially transparent birefringent elements.
- 1 January 2020
- Published by Optica Publishing Group
- p. FM1C.7
Discerning Polarization Objects using Non-local Measurements with Metasurfaces
We present an original non-local ghost measurement scheme with polarization-entangled photons, where nanostructured dielectric metasurfaces enable discrimination between a set of objects with different polarization characteristics, including fully or partially transparent birefringent elements.