Tushar Srivastava
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Tushar Srivastava has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Sasidhar Kondaraju
School of Mechanical Sciences, Indian Institute of Technology Bhubaneswar, Argul, Odisha 752050, India
2 shared publications - Gunjan Varshney
JSS University, Noida, Uttar Pradesh, India
1 shared publication Riya Tohangar
J.S.S. Academy of Technical Education Noida, Noida, U.P., India
1 shared publication- Santosh Kumar Jena
School of Mechanical Sciences, Indian Institute of Technology Bhubaneswar , Khordha, Odisha 752050
1 shared publication - Shreya Gupta
Department of Physics, Indian Institute of Technology Delhi, New Delhi 110016, India
1 shared publication - Supreet Singh Bahga
Indian Institute of Technology Delhi
1 shared publication
Latest Publications
- 1 February 2023
- Published by AIP Publishing in Physics of Fluids
- Vol. 35 (2)
Effect of channel width on droplet generation inside T-junction microchannel
In a T-junction microchannel, channel geometry plays a major role that affects the physics behind droplet generation. The effect of channel width on droplet size and frequency in a T-junction microchannel is investigated in the present study. The current work is an extension of our previous work, where a model was developed to predict the size of the droplets generated in a T-junction microchannel when both the continuous and dispersed phase channels have equal widths. In the present work, we extended the model to account for the varying width ratio between the dispersed and continuous phase channels. We performed in-house experiments by varying the channel width and viscosity ratios between the fluids to study the size of the droplets generated and to validate the proposed scaling law. We further investigated the effect of channel geometry on the frequency of droplet generation in the T-junction microchannels. The experimental results show that the droplet length increases with an increase in the width of the continuous phase channel. On the other hand, the droplet production frequency decreases with an increase in the width of the continuous phase channel. With variations in the width of the dispersed phase channel, similar behavior in droplet sizes and the frequency of droplet production is observed. The analysis of this study provides new insight into the effect of channel width on the droplet length and frequency. Overall, this research intends to provide a thorough understanding of the design of microchannels based on the geometry and manipulation of droplets with varying widths.
- 1 February 2023
- Published by AIP Publishing in Physics of Fluids
- Vol. 35 (2)
Effect of channel width on droplet generation inside T-junction microchannel
In a T-junction microchannel, channel geometry plays a major role that affects the physics behind droplet generation. The effect of channel width on droplet size and frequency in a T-junction microchannel is investigated in the present study. The current work is an extension of our previous work, where a model was developed to predict the size of the droplets generated in a T-junction microchannel when both the continuous and dispersed phase channels have equal widths. In the present work, we extended the model to account for the varying width ratio between the dispersed and continuous phase channels. We performed in-house experiments by varying the channel width and viscosity ratios between the fluids to study the size of the droplets generated and to validate the proposed scaling law. We further investigated the effect of channel geometry on the frequency of droplet generation in the T-junction microchannels. The experimental results show that the droplet length increases with an increase in the width of the continuous phase channel. On the other hand, the droplet production frequency decreases with an increase in the width of the continuous phase channel. With variations in the width of the dispersed phase channel, similar behavior in droplet sizes and the frequency of droplet production is observed. The analysis of this study provides new insight into the effect of channel width on the droplet length and frequency. Overall, this research intends to provide a thorough understanding of the design of microchannels based on the geometry and manipulation of droplets with varying widths.
- 11 November 2022
- Published by Bentham Science Publishers Ltd. in Recent Patents on Engineering
- Vol. 17, 1
WITHDRAWN: Design of Smart Temperature Monitoring and Automatic Sanitizer Dispenser
As it is very difficult for organizations and public places in COVID era to measure and keep record of their body temperature and sanitize every individual. We have experienced that due to lethargic nature the guards or any individual responsible for this task doesn’t perform it properly and are not bothered of taking temperature. This would lead to a huge wave of spreading the chain of COVID patients at the national level. So, our proposed design of device will be setup in front of entry doors and will get adjusted itself to the height of the customer approaching such that the temperature sensor will be exactly in front of the face. And it will also encourage the customer to bring hand forward to take the sanitizer. Background-- The design was created in reference with many other existing designs but it has advanced and uses upgraded version of technologies. It encourages individuals to put their hand forward for sanitization and restricts the entry of the individuals incase their temperature is found to be more than the normal temperature. Method-- The design will automatically measure the temperature and sanitize the individual passing through it. As the person approaches the device, the base sensor senses the presence of the individual and the belt and gear system gets activated and places the forehead near to the temperature sensor. If the temperature is found to be normal then the device will encourage the individual to put their hand forward to take the sanitizer. Results-- Simulation work has been done on TinkerCAD online software, the results and circuit-diagram have been shown. The simulation diagram explains the working of the Smart Temperature Monitoring and Automatic Sanitizer Dispenser. Conclusion-- The proposed design is very efficient and is capable of reducing human intervention. Our device acts as an assistant to the organization for maintaining the Covid protocols thereby reducing the risk of spread of the virus
- 11 November 2022
- Published by Bentham Science Publishers Ltd. in Recent Patents on Engineering
- Vol. 17, 1
WITHDRAWN: Design of Smart Temperature Monitoring and Automatic Sanitizer Dispenser
As it is very difficult for organizations and public places in COVID era to measure and keep record of their body temperature and sanitize every individual. We have experienced that due to lethargic nature the guards or any individual responsible for this task doesn’t perform it properly and are not bothered of taking temperature. This would lead to a huge wave of spreading the chain of COVID patients at the national level. So, our proposed design of device will be setup in front of entry doors and will get adjusted itself to the height of the customer approaching such that the temperature sensor will be exactly in front of the face. And it will also encourage the customer to bring hand forward to take the sanitizer. Background-- The design was created in reference with many other existing designs but it has advanced and uses upgraded version of technologies. It encourages individuals to put their hand forward for sanitization and restricts the entry of the individuals incase their temperature is found to be more than the normal temperature. Method-- The design will automatically measure the temperature and sanitize the individual passing through it. As the person approaches the device, the base sensor senses the presence of the individual and the belt and gear system gets activated and places the forehead near to the temperature sensor. If the temperature is found to be normal then the device will encourage the individual to put their hand forward to take the sanitizer. Results-- Simulation work has been done on TinkerCAD online software, the results and circuit-diagram have been shown. The simulation diagram explains the working of the Smart Temperature Monitoring and Automatic Sanitizer Dispenser. Conclusion-- The proposed design is very efficient and is capable of reducing human intervention. Our device acts as an assistant to the organization for maintaining the Covid protocols thereby reducing the risk of spread of the virus
- 1 September 2020
- Published by AIP Publishing in Physics of Fluids
- Vol. 32 (9) , 092103
Analytical model for predicting maximum spread of droplet impinging on solid surfaces
In the present study, we develop a theoretical approach to predict the maximum spread of a liquid droplet on a dry solid surface. By using the dynamics of the gas layer entrapped underneath the droplet during initial stages of spreading, we determine the initial spread velocity of the droplet. The predicted spread velocity is used to model viscous dissipation and spread time of the droplet, post-impact. We also reformulate the surface energy of the droplet at the maximum spread to account for the presence of a rim formed at the periphery of the droplet. Incorporating the renewed terms into an energy conservation equation, the maximum spread of the droplet is predicted. The constructed model is validated with both the in-house experiments and the literature performed for various liquids and surfaces. The study also examines the existing scaling laws available to predict the maximum spread in inertial and viscous regimes and compares them with the model. Results reveal that the proposed model effectively predicts maximum spread values even at a low Weber number, despite variations in wettability values. The scaling laws were found to be inefficient in predicting the maximum spread for water at a low Weber number as they do not account for the effect of the surface wettability.
- 1 September 2020
- Published by AIP Publishing in Physics of Fluids
- Vol. 32 (9) , 092103
Analytical model for predicting maximum spread of droplet impinging on solid surfaces
In the present study, we develop a theoretical approach to predict the maximum spread of a liquid droplet on a dry solid surface. By using the dynamics of the gas layer entrapped underneath the droplet during initial stages of spreading, we determine the initial spread velocity of the droplet. The predicted spread velocity is used to model viscous dissipation and spread time of the droplet, post-impact. We also reformulate the surface energy of the droplet at the maximum spread to account for the presence of a rim formed at the periphery of the droplet. Incorporating the renewed terms into an energy conservation equation, the maximum spread of the droplet is predicted. The constructed model is validated with both the in-house experiments and the literature performed for various liquids and surfaces. The study also examines the existing scaling laws available to predict the maximum spread in inertial and viscous regimes and compares them with the model. Results reveal that the proposed model effectively predicts maximum spread values even at a low Weber number, despite variations in wettability values. The scaling laws were found to be inefficient in predicting the maximum spread for water at a low Weber number as they do not account for the effect of the surface wettability.