André Henrique Dias
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
André Henrique Dias has a total of 62 co-authors. Here are the top co-authors by number of shared publications:
- Lars Christian Gormsen
Department of Nuclear Medicine and PET Centre (L.C.G.), Aarhus University Hospital, Denmark
9 shared publications - Ole Lajord Munk
Department of Nuclear Medicine, Aarhus University Hospital, Aarhus, Denmark; Department of Clinical Medicine, Aarhus University, Aarhus, Denmark
9 shared publications Lars C. Gormsen
Nuklearmedicin, Aarhus Universitetshospita
3 shared publicationsOle L. Munk
Nuklearmedicin, Aarhus Universitetshospita
3 shared publications- Flemming Littrup Andersen
Department of Clinical Physiology and Nuclear Medicine, Rigshospitalet, Copenhagen, Denmark; Department of Clinical Medicine, University of Copenhagen, Copenhagen, Denmark
2 shared publications - Jorun Holm
Department of Nuclear Medicine, Odense University Hospital, 5000 Odense, Denmark
2 shared publications
Latest Publications
- Open Access
- 12 May 2026
- Published by Elsevier in European Journal of Surgical Oncology
- Vol. 52 (7) , 111878
Prognostic value of the SENTIREC-endo algorithm integrating sentinel lymph node and FDG-PET/CT in staging high-risk endometrial cancer
- 12 May 2026
- Published by Elsevier in European Journal of Surgical Oncology
- Vol. 52 (7) , 111878
Open AccessPrognostic value of the SENTIREC-endo algorithm integrating sentinel lymph node and FDG-PET/CT in staging high-risk endometrial cancer
- Open Access
- 6 May 2026
- Published by Elsevier in Seminars in Nuclear Medicine
- Vol. 56 (4) , 709-718
Positron emission tomography imaging of inflammation and infection in children: an update
- 6 May 2026
- Published by Elsevier in Seminars in Nuclear Medicine
- Vol. 56 (4) , 709-718
Open AccessPositron emission tomography imaging of inflammation and infection in children: an update
- Open Access
- 30 March 2026
- Published by Danish Medical Association in Ugeskrift for Læger
- Vol. 188 (14) , 1-4
Helkrops, long-axial field-of-view-PET/CT – hvad er det?
- 30 March 2026
- Published by Danish Medical Association in Ugeskrift for Læger
- Vol. 188 (14) , 1-4
Open AccessHelkrops, long-axial field-of-view-PET/CT – hvad er det?
- Open Access
Diagnostic Accuracy and Interrater Agreement of FDG-PET/CT Lymph Node Staging in High-Risk Endometrial Cancer: The SENTIREC-Endo Study
Background/Objectives: The SENTIREC-endo study identified a safe sentinel lymph node mapping algorithm combined with PET-positive node dissection, matching radical pelvic and paraaortic lymphadenectomy in high-risk endometrial cancer. The present study evaluated the diagnostic accuracy of FDG-PET/CT for lymph node metastases in the same population based on location, size, and Standardised Uptake Value (SUV), in addition to assessing interrater agreement across three Danish centres. Methods: This prospective multicentre study included women with high-risk endometrial cancer from the Danish SENTIREC study database (2017–2023). All patients underwent preoperative FDG-PET/CT. Diagnostic accuracy was evaluated against a pathology-confirmed reference standard. Interrater agreement was evaluated between trained specialists in Nuclear Medicine. Results: Among 227 patients, 52 patients (23%) had lymph node metastases. FDG-PET/CT identified lymph node metastases with 56% sensitivity (95% CI: 42–68) and 91% specificity (95% CI: 86–94). Positive and negative predictive values were 64% and 87%, respectively. Specificity for paraaortic nodes was high (97%), though sensitivity remained limited (56%). Lymph node size and SUVmax had moderate diagnostic value (AUC-ROC ~0.7). Interrater proportion of agreement was 95% and Cohen’s Kappa κ = 0.84 (95% CI: 0.73–0.94), the latter of which was ‘almost perfect’. Conclusions: FDG-PET/CT had limited sensitivity in lymph node staging in high-risk EC, and the diagnostic accuracy of FDG-PET/CT remains complementary to the sentinel node procedure. Due to its high specificity and strong interrater reliability, FDG-PET/CT is recommended for clinical implementation in combination with the sensitive sentinel node biopsy for the targeted dissection of PET-positive lymph nodes, particularly in paraaortic regions.
Open AccessDiagnostic Accuracy and Interrater Agreement of FDG-PET/CT Lymph Node Staging in High-Risk Endometrial Cancer: The SENTIREC-Endo Study
Background/Objectives: The SENTIREC-endo study identified a safe sentinel lymph node mapping algorithm combined with PET-positive node dissection, matching radical pelvic and paraaortic lymphadenectomy in high-risk endometrial cancer. The present study evaluated the diagnostic accuracy of FDG-PET/CT for lymph node metastases in the same population based on location, size, and Standardised Uptake Value (SUV), in addition to assessing interrater agreement across three Danish centres. Methods: This prospective multicentre study included women with high-risk endometrial cancer from the Danish SENTIREC study database (2017–2023). All patients underwent preoperative FDG-PET/CT. Diagnostic accuracy was evaluated against a pathology-confirmed reference standard. Interrater agreement was evaluated between trained specialists in Nuclear Medicine. Results: Among 227 patients, 52 patients (23%) had lymph node metastases. FDG-PET/CT identified lymph node metastases with 56% sensitivity (95% CI: 42–68) and 91% specificity (95% CI: 86–94). Positive and negative predictive values were 64% and 87%, respectively. Specificity for paraaortic nodes was high (97%), though sensitivity remained limited (56%). Lymph node size and SUVmax had moderate diagnostic value (AUC-ROC ~0.7). Interrater proportion of agreement was 95% and Cohen’s Kappa κ = 0.84 (95% CI: 0.73–0.94), the latter of which was ‘almost perfect’. Conclusions: FDG-PET/CT had limited sensitivity in lymph node staging in high-risk EC, and the diagnostic accuracy of FDG-PET/CT remains complementary to the sentinel node procedure. Due to its high specificity and strong interrater reliability, FDG-PET/CT is recommended for clinical implementation in combination with the sensitive sentinel node biopsy for the targeted dissection of PET-positive lymph nodes, particularly in paraaortic regions.
- Open Access
- 12 May 2025
- Published by Springer Nature in EJNMMI Research
- Vol. 15 (1) , 1-11
Test-retest repeatability of quantitative organ and tissue uptake using 20-minute dynamic multiparametric whole-body [18F]FDG PET/CT in patients with type 2 diabetes
Recently developed dynamic whole-body PET/CT (D-WB PET/CT) protocols allow for measurements of potentially more precise metabolic parameters than the commonly used semiquantitative SUV. Most notable is the metabolic rate of FDG uptake (MRFDG), which reflects quantitative glucose uptake into tissues and organs. However, data on the reproducibility of MRFDG measurements are scarce, particularly in patients with perturbed glucose homeostasis such as type 2 diabetes. We therefore aimed to evaluate the test-retest repeatability of both MRFDG and SUV in these patients. Fifteen participants (mean age 71 ± 7 years; 2 females) with type 2 diabetes underwent a short 20-minute [18F]FDG D-WB PET/CT after 6 h fasting on two consecutive days. Both SUV and MRFDG images were reconstructed from D-WB PET/CT data obtained 60–80 min post-injection of [18F]FDG. MRFDG and SUV data were measured in organs and tissues, and repeatability was assessed with Bland-Altman analysis, intraclass correlation coefficients (ICC), repeatability coefficients (RPC) and coefficients of variation (wCV). There was high repeatability of both SUVmean and MRFDG−mean in all measured organs (ICC range: 0.65–0.95 for SUVmean and 0.66–0.94 for MRFDG−mean). SUVmean generally demonstrated higher reliability (ICC) and lower variability (%RPC and %wCV) when compared to MRFDG−mean. However, MRFDG test-retest variation was < 19% in most analysed tissues, demonstrating that MRFDG may be used as a precise marker of treatment response. This study demonstrates that MRFDG calculated from D-WB PET/CT exhibit high repeatability, comparable to SUVs across most organs in patients with type 2 diabetes.
- 12 May 2025
- Published by Springer Nature in EJNMMI Research
- Vol. 15 (1) , 1-11
Open AccessTest-retest repeatability of quantitative organ and tissue uptake using 20-minute dynamic multiparametric whole-body [18F]FDG PET/CT in patients with type 2 diabetes
Recently developed dynamic whole-body PET/CT (D-WB PET/CT) protocols allow for measurements of potentially more precise metabolic parameters than the commonly used semiquantitative SUV. Most notable is the metabolic rate of FDG uptake (MRFDG), which reflects quantitative glucose uptake into tissues and organs. However, data on the reproducibility of MRFDG measurements are scarce, particularly in patients with perturbed glucose homeostasis such as type 2 diabetes. We therefore aimed to evaluate the test-retest repeatability of both MRFDG and SUV in these patients. Fifteen participants (mean age 71 ± 7 years; 2 females) with type 2 diabetes underwent a short 20-minute [18F]FDG D-WB PET/CT after 6 h fasting on two consecutive days. Both SUV and MRFDG images were reconstructed from D-WB PET/CT data obtained 60–80 min post-injection of [18F]FDG. MRFDG and SUV data were measured in organs and tissues, and repeatability was assessed with Bland-Altman analysis, intraclass correlation coefficients (ICC), repeatability coefficients (RPC) and coefficients of variation (wCV). There was high repeatability of both SUVmean and MRFDG−mean in all measured organs (ICC range: 0.65–0.95 for SUVmean and 0.66–0.94 for MRFDG−mean). SUVmean generally demonstrated higher reliability (ICC) and lower variability (%RPC and %wCV) when compared to MRFDG−mean. However, MRFDG test-retest variation was < 19% in most analysed tissues, demonstrating that MRFDG may be used as a precise marker of treatment response. This study demonstrates that MRFDG calculated from D-WB PET/CT exhibit high repeatability, comparable to SUVs across most organs in patients with type 2 diabetes.
- 20 March 2025
- Published by Springer Nature in European Journal of Nuclear Medicine and Molecular Imaging
- Vol. 52 (9) , 3364-3365
Takayasu’s arteritis imaged by a LAFOV PET/CT system: better resolution leads to greater diagnostic certainty
- 20 March 2025
- Published by Springer Nature in European Journal of Nuclear Medicine and Molecular Imaging
- Vol. 52 (9) , 3364-3365
Takayasu’s arteritis imaged by a LAFOV PET/CT system: better resolution leads to greater diagnostic certainty
- 14 December 2024
- Published by Springer Nature in European Journal of Nuclear Medicine and Molecular Imaging
- Vol. 52 (7) , 2249-2250
Rare mesenteric vein thrombophlebitis: a case for high-sensitivity long axial field-of view PET/CT imaging
- 14 December 2024
- Published by Springer Nature in European Journal of Nuclear Medicine and Molecular Imaging
- Vol. 52 (7) , 2249-2250
Rare mesenteric vein thrombophlebitis: a case for high-sensitivity long axial field-of view PET/CT imaging
- 14 December 2024
- Published by Springer Nature in European Journal of Nuclear Medicine and Molecular Imaging
- Vol. 52 (5) , 1924-1936
Validation and clinical impact of motion-free PET imaging using data-driven respiratory gating and elastic PET-CT registration
Purpose Clinical whole-body (WB) PET images can be compensated for respiratory motion using data-driven gating (DDG). However, PET DDG images may still exhibit motion artefacts at the diaphragm if the CT is acquired in a different respiratory phase than the PET image. This study evaluates the combined use of PET DDG and a deep-learning model (AIR-PETCT) for elastic registration of CT (WarpCT) to the non attenuation- and non scatter-corrected PET image (PET NAC), enabling improved PET reconstruction. Methods The validation cohort included 20 patients referred for clinical FDG PET/CT, undergoing two CT scans: a free respiration CTfree and an end-expiration breath-hold CTex. AIR-PETCT registered each CT to the PET NAC and PET DDG NAC images. The image quality of PET and PET DDG images reconstructed using CTs and WarpCTs was evaluated by three blinded readers. Additionally, a clinical impact cohort of 20 patients with significant “banana” artefacts from FDG, PSMA, and DOTATOC scans was assessed for image quality and tumor-to-background ratios. Results AIR-PETCT was robust and generated consistent WarpCTs when registering different CTs to the same PET NAC. The use of WarpCT instead of CT consistently led to equivalent or improved PET image quality. The algorithm significantly reduced “banana” artefacts and improved lesion-to-background ratios around the diaphragm. The blinded clinicians clearly preferred PET DDG images reconstructed using WarpCT. Conclusion AIR-PETCT effectively reduces respiratory motion artefacts from PET images, while improving lesion contrast. The combination of PET DDG and WarpCT holds promise for clinical application, improving PET image evaluation and diagnostic confidence.
- 14 December 2024
- Published by Springer Nature in European Journal of Nuclear Medicine and Molecular Imaging
- Vol. 52 (5) , 1924-1936
Validation and clinical impact of motion-free PET imaging using data-driven respiratory gating and elastic PET-CT registration
Purpose Clinical whole-body (WB) PET images can be compensated for respiratory motion using data-driven gating (DDG). However, PET DDG images may still exhibit motion artefacts at the diaphragm if the CT is acquired in a different respiratory phase than the PET image. This study evaluates the combined use of PET DDG and a deep-learning model (AIR-PETCT) for elastic registration of CT (WarpCT) to the non attenuation- and non scatter-corrected PET image (PET NAC), enabling improved PET reconstruction. Methods The validation cohort included 20 patients referred for clinical FDG PET/CT, undergoing two CT scans: a free respiration CTfree and an end-expiration breath-hold CTex. AIR-PETCT registered each CT to the PET NAC and PET DDG NAC images. The image quality of PET and PET DDG images reconstructed using CTs and WarpCTs was evaluated by three blinded readers. Additionally, a clinical impact cohort of 20 patients with significant “banana” artefacts from FDG, PSMA, and DOTATOC scans was assessed for image quality and tumor-to-background ratios. Results AIR-PETCT was robust and generated consistent WarpCTs when registering different CTs to the same PET NAC. The use of WarpCT instead of CT consistently led to equivalent or improved PET image quality. The algorithm significantly reduced “banana” artefacts and improved lesion-to-background ratios around the diaphragm. The blinded clinicians clearly preferred PET DDG images reconstructed using WarpCT. Conclusion AIR-PETCT effectively reduces respiratory motion artefacts from PET images, while improving lesion contrast. The combination of PET DDG and WarpCT holds promise for clinical application, improving PET image evaluation and diagnostic confidence.
- Open Access
- 13 November 2024
- Published by Elsevier in Seminars in Nuclear Medicine
- Vol. 55 (1) , 76-85
Long Axial Field-of-View PET/CT: New Opportunities for Pediatric Imaging
- 13 November 2024
- Published by Elsevier in Seminars in Nuclear Medicine
- Vol. 55 (1) , 76-85
Open AccessLong Axial Field-of-View PET/CT: New Opportunities for Pediatric Imaging
- 13 June 2024
- Published by Springer Nature in European Journal of Nuclear Medicine and Molecular Imaging
- Vol. 51 (12) , 3802-3804
First-in-human whole-body PET/CT imaging with the optimized ketone tracer [11C]β-hydroxybutyrate using a long axial field-of-view scanner
- 13 June 2024
- Published by Springer Nature in European Journal of Nuclear Medicine and Molecular Imaging
- Vol. 51 (12) , 3802-3804
First-in-human whole-body PET/CT imaging with the optimized ketone tracer [11C]β-hydroxybutyrate using a long axial field-of-view scanner