Rainer Bischoff
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Rainer Bischoff has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
Meik Stoll
French-German Research Institute of Saint-Louis (ISL),Saint-Louis,France,68301
2 shared publicationsRalf Himmelsbach
French-German Research Institute of Saint-Louis (ISL), Saint Louis, France
2 shared publicationsSigo Scharnholz
French-German Research Institute of Saint-Louis (ISL),Saint-Louis,France,68301
2 shared publicationsI.A. Shemyakin
Inst. of High Current Electron., Russian Acad. of Sci., Tomsk, Russia
1 shared publicationI.J. Petzenhauser
Department of Physics, University of Erlangen‐Nuremberg Erlangen Germany
1 shared publicationK. Frank
Department of Physics, University of Erlangen‐Nuremberg Erlangen Germany
1 shared publication
Latest Publications
- 19 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Plasma Science
- Vol. 54 (4) , 1377-1381
Transformer-Coupled LC Inversion Generators With Voltage-Inverted and Bipolar Output Signals
The transformer-coupled LC-inversion generator (TCLCG) stands out due to its requirement of only one closing switch for voltage multiplication, independent of the number of stages. LTSPICE simulations and experiments have demonstrated the feasibility of two novel TCLCG circuit configurations that enable the inversion of the first half-cycle of the oscillating output voltage signal with respect to the polarity of the charging voltage, distinguishing them from conventional TCLCG designs. In the first solution, this is accomplished by modifying the wiring of the last-stage transformer. In the second solution, the first-stage transformer is modified, and an additional inductance is added at the generator output to earth ground. Here, the odd-numbered capacitors facilitate rapid voltage multiplication, while the even-numbered capacitors already have the correct inverted polarity. Consequently, the development of a bipolar TCLCG became feasible, consisting of a conventional noninverting and an inverting generator branch in parallel, both controlled by a single closing switch. A six-stage bipolar TCLCG, comprising matched three-stage noninverting and inverting generator branches with synchronized oscillation frequencies, achieved a peak differential voltage of 183 kV across a resistive load of 447 k $\Omega $ at a charging voltage of 21.6 kV. The contributions from the two generator branches summed almost perfectly, with an average loss of 1.2%. The rise time of the generator’s differential output signal was 25 ns. The achieved peak-to-peak differential voltage reached 301 kV. Potential applications include the control of symmetrically designed antennas.
- 19 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Plasma Science
- Vol. 54 (4) , 1377-1381
Transformer-Coupled LC Inversion Generators With Voltage-Inverted and Bipolar Output Signals
The transformer-coupled LC-inversion generator (TCLCG) stands out due to its requirement of only one closing switch for voltage multiplication, independent of the number of stages. LTSPICE simulations and experiments have demonstrated the feasibility of two novel TCLCG circuit configurations that enable the inversion of the first half-cycle of the oscillating output voltage signal with respect to the polarity of the charging voltage, distinguishing them from conventional TCLCG designs. In the first solution, this is accomplished by modifying the wiring of the last-stage transformer. In the second solution, the first-stage transformer is modified, and an additional inductance is added at the generator output to earth ground. Here, the odd-numbered capacitors facilitate rapid voltage multiplication, while the even-numbered capacitors already have the correct inverted polarity. Consequently, the development of a bipolar TCLCG became feasible, consisting of a conventional noninverting and an inverting generator branch in parallel, both controlled by a single closing switch. A six-stage bipolar TCLCG, comprising matched three-stage noninverting and inverting generator branches with synchronized oscillation frequencies, achieved a peak differential voltage of 183 kV across a resistive load of 447 k $\Omega $ at a charging voltage of 21.6 kV. The contributions from the two generator branches summed almost perfectly, with an average loss of 1.2%. The rise time of the generator’s differential output signal was 25 ns. The achieved peak-to-peak differential voltage reached 301 kV. Potential applications include the control of symmetrically designed antennas.
- 28 July 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Plasma Science
- Vol. PP (00933813) , 1-6
Investigation of a Novel Circuit Topology for Fast Transformer-Coupled LC Inversion Generators
A novel solution for the electrical connection of transformer-coupled LC inversion generators (TCLCGs) is presented and evaluated in terms of performance relative to the conventional “textbook” circuit topology through experimental and simulation-based analyses. The solution, henceforth referred to as the modified alternative circuit, is based on the alternative circuit for a TCLCG with parallel connection of the transformer and identical even-numbered capacitors. The novel solution distinguished by the complete elimination of the even-numbered storage capacitors in the circuit, without any adverse effects on the generator’s efficiency. This significantly reduces the rise time of the output signal by increasing the associated LC resonant circuit $f_{2n} \sim (L_{TL,n} \cdot C_{\text {par}})^{-1/2}$ , where only parasitic capacitances, which on the generator size and geometry effectively need to be considered. These are typically on the order of tens of picofarads. Three variants of the TCLCG in the modified alternative circuit with varying energy storage capabilities and appropriately sized transformers were constructed and tested. The experimental results were compared with LTSPICE simulations using the Chan model to describe the nonlinear behavior of the transformers. High-frequency-compatible 4C65 ferrite toroidal cores from Ferroxcube were used by default for the transformer.
- 28 July 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Plasma Science
- Vol. PP (00933813) , 1-6
Investigation of a Novel Circuit Topology for Fast Transformer-Coupled LC Inversion Generators
A novel solution for the electrical connection of transformer-coupled LC inversion generators (TCLCGs) is presented and evaluated in terms of performance relative to the conventional “textbook” circuit topology through experimental and simulation-based analyses. The solution, henceforth referred to as the modified alternative circuit, is based on the alternative circuit for a TCLCG with parallel connection of the transformer and identical even-numbered capacitors. The novel solution distinguished by the complete elimination of the even-numbered storage capacitors in the circuit, without any adverse effects on the generator’s efficiency. This significantly reduces the rise time of the output signal by increasing the associated LC resonant circuit $f_{2n} \sim (L_{TL,n} \cdot C_{\text {par}})^{-1/2}$ , where only parasitic capacitances, which on the generator size and geometry effectively need to be considered. These are typically on the order of tens of picofarads. Three variants of the TCLCG in the modified alternative circuit with varying energy storage capabilities and appropriately sized transformers were constructed and tested. The experimental results were compared with LTSPICE simulations using the Chan model to describe the nonlinear behavior of the transformers. High-frequency-compatible 4C65 ferrite toroidal cores from Ferroxcube were used by default for the transformer.
- 7 September 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Plasma Science
- Vol. 51 (10) , 2781-2787
Investigations on a Semiconductor Switching Array Based on COTS SiC MOSFET Devices
We report on the development of a switching array based on commercially off-the-shelf (COTS) silicon-carbide (SiC) MOSFET devices. In the first step, preparatory investigations for series and parallel arrangement of the SiC MOSFETs were carried out. A switching module consisting of ten SiC MOSFETs of type C3M0075120K by Wolfspeed in series with an inductive galvanic isolation between the gate driver and SiC MOSFETs was designed and built. Each one of the ten SiC MOSFETs has its own gate control circuit to minimize turn-on time. It was successfully tested up to a switching voltage of 10.0 kV, reaching a current turn-on time of 20 ns at a drain current of 39.7 A. The studies on parallel arrangement dealt with the question of how many SiC MOSFETs per gate driver constitute a good compromise between switching speed and technological complexity. The realized switch consisted of 12 Wolfspeed C3M0075120K SiC MOSFETs in parallel, grouped in units of four per gate driver. The switch was successfully tested up to a charging voltage of 0.81 kV on a resistive load of 0.8 $\Omega $ . The resulting switch current was 1.01 kA; the turn-on time was 11 ns. The next step was the development of a test board, which could be equipped with up to 12 MOSFETs in series and 12 MOSFETs in parallel. Hence, the maximum possible number of SiC MOSFETs would be 144, arranged in a (12 $\times$ 12) array. The principle of implementation of the inductive galvanic isolation, now placed between the gate control circuit and gate driver, and of the dedicated power supply solution for the gate driver will be discussed. Equipped with 40 Wolfspeed C3M0075120K SiC MOSFETs in a (10 $\times$ 4) array, a drain current of 416 A was switched at 10.4-kV charging voltage. The current rise time was 42 ns. Furthermore, the scalability to higher switching voltages was investigated. Two test boards were stacked to a 20-kV switching module, which required further adaptation of the power supply of the gate driver. The switch was tested up to 20.9 kV. The turn-on time was 17 ns at a drain current of 20 A. Finally, a second 20-kV switching module was built, and the now available two modules were used as closing switches for a two-stage semiconductor Marx generator. The Marx reached an output voltage of 28 kV and a voltage rise time of 27 ns at a load current of 60 A.
- 7 September 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Plasma Science
- Vol. 51 (10) , 2781-2787
Investigations on a Semiconductor Switching Array Based on COTS SiC MOSFET Devices
We report on the development of a switching array based on commercially off-the-shelf (COTS) silicon-carbide (SiC) MOSFET devices. In the first step, preparatory investigations for series and parallel arrangement of the SiC MOSFETs were carried out. A switching module consisting of ten SiC MOSFETs of type C3M0075120K by Wolfspeed in series with an inductive galvanic isolation between the gate driver and SiC MOSFETs was designed and built. Each one of the ten SiC MOSFETs has its own gate control circuit to minimize turn-on time. It was successfully tested up to a switching voltage of 10.0 kV, reaching a current turn-on time of 20 ns at a drain current of 39.7 A. The studies on parallel arrangement dealt with the question of how many SiC MOSFETs per gate driver constitute a good compromise between switching speed and technological complexity. The realized switch consisted of 12 Wolfspeed C3M0075120K SiC MOSFETs in parallel, grouped in units of four per gate driver. The switch was successfully tested up to a charging voltage of 0.81 kV on a resistive load of 0.8 $\Omega $ . The resulting switch current was 1.01 kA; the turn-on time was 11 ns. The next step was the development of a test board, which could be equipped with up to 12 MOSFETs in series and 12 MOSFETs in parallel. Hence, the maximum possible number of SiC MOSFETs would be 144, arranged in a (12 $\times$ 12) array. The principle of implementation of the inductive galvanic isolation, now placed between the gate control circuit and gate driver, and of the dedicated power supply solution for the gate driver will be discussed. Equipped with 40 Wolfspeed C3M0075120K SiC MOSFETs in a (10 $\times$ 4) array, a drain current of 416 A was switched at 10.4-kV charging voltage. The current rise time was 42 ns. Furthermore, the scalability to higher switching voltages was investigated. Two test boards were stacked to a 20-kV switching module, which required further adaptation of the power supply of the gate driver. The switch was tested up to 20.9 kV. The turn-on time was 17 ns at a drain current of 20 A. Finally, a second 20-kV switching module was built, and the now available two modules were used as closing switches for a two-stage semiconductor Marx generator. The Marx reached an output voltage of 28 kV and a voltage rise time of 27 ns at a load current of 60 A.
- 7 September 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Plasma Science
- Vol. 48 (10) , 3424-3428
An Alternative Circuitry for a Transformer-Coupled LC Inversion Generator
A new alternative circuitry for the transformer-coupled LC inversion generator (TCLCG) is presented. In principle, a TCLCG consists of one in-phase 1:1 transformer and two capacitors per elementary stage. First, the two capacitors will be charged via the primary winding of the transformer in opposite polarity. Afterward, voltage multiplication is being achieved by a closing switch which shortcuts the two capacitors. The odd-numbered capacitor discharges slowly through the primary inductance of the transformer, whereas the even-numbered capacitor discharges fastly through only the leakage inductance of the transformer and, thus, inverts. However, one of the main drawbacks of the classical ``textbook'' TCLCG circuitry is caused by the fact that connection of the transformers of the higher generator stages is done through the transformers of the lower stages. Consequently, compensation techniques must be applied, i.e., adjustment of the even capacitors and/or transformer inductance values, in order to ensure effective voltage multiplication by means of constructive superposition of each stage. This limits the maximum practical generator stage number and rise time. In the alternative TCLCG circuit principle, the connections to the primary and secondary inputs of the transformers of the higher stages are being done directly from the closing switch. Now, the transformers are in parallel to each other, not in series as in the classical TCLCG circuitry. As a result, the even-numbered capacitors see the same leakage inductance and compensation techniques are no longer necessary. The first experimental verification was done by direct comparison of the classical circuitry and alternative circuitry for two compact two-stage TCLCGs with identical transformers and capacitances. The results showed that the alternative circuitry leads to a fast generator rise time of 25 ns, about 38% faster than the classical circuitry, while still reaching the same generator efficiency of 67%. Additionally, rise time proved to stay constant at 25 ns even if adding the third stage to the TCLCG with the new alternative geometry. This version was still 46% faster than an optimized classical three-stage TCLCG using the asymmetric compensation method.
- 7 September 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Plasma Science
- Vol. 48 (10) , 3424-3428
An Alternative Circuitry for a Transformer-Coupled LC Inversion Generator
A new alternative circuitry for the transformer-coupled LC inversion generator (TCLCG) is presented. In principle, a TCLCG consists of one in-phase 1:1 transformer and two capacitors per elementary stage. First, the two capacitors will be charged via the primary winding of the transformer in opposite polarity. Afterward, voltage multiplication is being achieved by a closing switch which shortcuts the two capacitors. The odd-numbered capacitor discharges slowly through the primary inductance of the transformer, whereas the even-numbered capacitor discharges fastly through only the leakage inductance of the transformer and, thus, inverts. However, one of the main drawbacks of the classical ``textbook'' TCLCG circuitry is caused by the fact that connection of the transformers of the higher generator stages is done through the transformers of the lower stages. Consequently, compensation techniques must be applied, i.e., adjustment of the even capacitors and/or transformer inductance values, in order to ensure effective voltage multiplication by means of constructive superposition of each stage. This limits the maximum practical generator stage number and rise time. In the alternative TCLCG circuit principle, the connections to the primary and secondary inputs of the transformers of the higher stages are being done directly from the closing switch. Now, the transformers are in parallel to each other, not in series as in the classical TCLCG circuitry. As a result, the even-numbered capacitors see the same leakage inductance and compensation techniques are no longer necessary. The first experimental verification was done by direct comparison of the classical circuitry and alternative circuitry for two compact two-stage TCLCGs with identical transformers and capacitances. The results showed that the alternative circuitry leads to a fast generator rise time of 25 ns, about 38% faster than the classical circuitry, while still reaching the same generator efficiency of 67%. Additionally, rise time proved to stay constant at 25 ns even if adding the third stage to the TCLCG with the new alternative geometry. This version was still 46% faster than an optimized classical three-stage TCLCG using the asymmetric compensation method.
- 1 June 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 200-203
Investigation of a fast high-repetitive 10-kV SiC-MOSFET switching module
We report on the development of a 10-kV SiC MOSFET-based switching module, which can be easily scaled-up because of the principle of a serial connection of the SiC MOSFETs. In detail, the switching module consists of two circuit boards, each one featuring five Wolfspeed 1200-V C2M0080120D SiC MOSFETs, that are getting stacked in order to minimize the area of the current loop between high voltage and ground connector and as a result the inductance of the structure. The gate control of each SiC MOSFET is connected to a separate high-speed gate driver circuit, which is being triggered optically. The DC voltage supply of the components of each of the gate driver circuit is battery powered. As an overvoltage protection for the SiC MOSFETs and the optical receivers, the switching module uses transient voltage suppression (TVS) diodes. The turn-on time was experimentally determined to t on = 21 ns at a switching voltage of V SW = 10 kV and an average drain current of I D = 38.5 A. A first successful test in burst-mode with a burst of 10 cycles at a pulse repetition frequency of f rep = 5 MHz was carried out. Planned usage of gate-boosting techniques for a further speeding-up of the turn-on behavior will be discussed.
- 1 June 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 200-203
Investigation of a fast high-repetitive 10-kV SiC-MOSFET switching module
We report on the development of a 10-kV SiC MOSFET-based switching module, which can be easily scaled-up because of the principle of a serial connection of the SiC MOSFETs. In detail, the switching module consists of two circuit boards, each one featuring five Wolfspeed 1200-V C2M0080120D SiC MOSFETs, that are getting stacked in order to minimize the area of the current loop between high voltage and ground connector and as a result the inductance of the structure. The gate control of each SiC MOSFET is connected to a separate high-speed gate driver circuit, which is being triggered optically. The DC voltage supply of the components of each of the gate driver circuit is battery powered. As an overvoltage protection for the SiC MOSFETs and the optical receivers, the switching module uses transient voltage suppression (TVS) diodes. The turn-on time was experimentally determined to t on = 21 ns at a switching voltage of V SW = 10 kV and an average drain current of I D = 38.5 A. A first successful test in burst-mode with a burst of 10 cycles at a pulse repetition frequency of f rep = 5 MHz was carried out. Planned usage of gate-boosting techniques for a further speeding-up of the turn-on behavior will be discussed.
- 5 October 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Plasma Science
- Vol. 45 (10) , 2618-2622
Fast Semiconductor Switching Modules for Transformer-Coupled LC Inversion Generators
The recent availability of fast high-power semiconductor switches makes the transformer coupled LC inversion generator (TCLCG) topology a very promising candidate for the realization of reliable, multi-kHz repetition rate pulse generators with an output voltage in the range of 200 kV and more. Usage of 1:1 transformers instead of closing switches in each generator stage reduces the total number of switches inside the TCLCG to only one, independent of the numbers of stages. Thus, problem of synchronization as in Marx-generators or classical LC inversion generators can be omitted. In principle, capacitors are initially charged to the charging voltage, whereas the odd-numbered of each stage are charged with the opposite polarity to the even-numbered capacitors. Fast voltage inversion of the even-numbered capacitors leads to efficient voltage multiplication provided the semiconductor switching module will be sufficiently fast to minimize switching losses. For initial investigations, a special asymmetrically compensated three-stage test TCLCG was designed and set up. Three high-voltage semiconductor switching modules were experimentally tested in detail; two 20-kV high-voltage switching modules consisting of a series arrangement of 15 Si-based insulated gate bipolar transistors or 15 SiC-based MOSFETs, with in each case 1700-V breakdown voltage, and a fast experimental 10-kV thyristor switching module with kilo ampere current carrying capability. The achievable output signal rise time and generator efficiency for different electrical loads (resistive, capacitive, or inductive) are discussed.
- 5 October 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Plasma Science
- Vol. 45 (10) , 2618-2622
Fast Semiconductor Switching Modules for Transformer-Coupled LC Inversion Generators
The recent availability of fast high-power semiconductor switches makes the transformer coupled LC inversion generator (TCLCG) topology a very promising candidate for the realization of reliable, multi-kHz repetition rate pulse generators with an output voltage in the range of 200 kV and more. Usage of 1:1 transformers instead of closing switches in each generator stage reduces the total number of switches inside the TCLCG to only one, independent of the numbers of stages. Thus, problem of synchronization as in Marx-generators or classical LC inversion generators can be omitted. In principle, capacitors are initially charged to the charging voltage, whereas the odd-numbered of each stage are charged with the opposite polarity to the even-numbered capacitors. Fast voltage inversion of the even-numbered capacitors leads to efficient voltage multiplication provided the semiconductor switching module will be sufficiently fast to minimize switching losses. For initial investigations, a special asymmetrically compensated three-stage test TCLCG was designed and set up. Three high-voltage semiconductor switching modules were experimentally tested in detail; two 20-kV high-voltage switching modules consisting of a series arrangement of 15 Si-based insulated gate bipolar transistors or 15 SiC-based MOSFETs, with in each case 1700-V breakdown voltage, and a fast experimental 10-kV thyristor switching module with kilo ampere current carrying capability. The achievable output signal rise time and generator efficiency for different electrical loads (resistive, capacitive, or inductive) are discussed.
- 17 October 2005
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Plasma Science
- Vol. 33 (5) , 1648-1653
Temporal structure of the fast electron beam generated in the pseudospark discharge with external triggering
This paper deals with the investigation of the fast electron beams that form in the high-current pseudospark discharge at different stages of its development. Three short-duration peak of the beam current at the discharge axis have been revealed. The physical reasons for the appearance of these peaks of the beam are discussed. The main idea of the proposed physical mechanism is that the electrons are accelerated in a double electric layer, which forms between the hollow cathode plasma and the near-anode plasma.
- 17 October 2005
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Plasma Science
- Vol. 33 (5) , 1648-1653
Temporal structure of the fast electron beam generated in the pseudospark discharge with external triggering
This paper deals with the investigation of the fast electron beams that form in the high-current pseudospark discharge at different stages of its development. Three short-duration peak of the beam current at the discharge axis have been revealed. The physical reasons for the appearance of these peaks of the beam are discussed. The main idea of the proposed physical mechanism is that the electrons are accelerated in a double electric layer, which forms between the hollow cathode plasma and the near-anode plasma.