HHHaegin Han

Haegin Han

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Haegin Han has a total of 70 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Physics-informed machine learning-based dose calculation for patients undergoing fluoroscopically guided interventional procedures

    by Haegin Han, Keith T Griffin, Monjoy Saha, A Kyle Jones, Steven D Mann, Kevin A Wunderle, Donald L Miller, Nina Petoussi-Henss, David Sutton, Choonsik Lee

    Objective. To develop and evaluate a physics-informed machine-learning framework for rapid organ-dose estimation in fluoroscopically guided interventional procedures without requiring patient-specific imaging. Approach. We used 385 adult radiation dose structured reports (RDSRs) from three procedure types—bilateral carotid angiography, percutaneous biliary drainage, and liver chemoembolization—comprising more than 50 000 irradiation events. A body-size-matched computational phantom was selected using patient sex, height, and weight. RDSR-derived beam parameters and engineered descriptors of beam-organ geometry and attenuation were used to train organ-specific XGBoost models for localized organs and a multi-output multilayer perceptron model for four distributed tissues. Monte Carlo (MC)-derived dose coefficients from NCIRF3 were used as target values. Main results. In the held-out test set of 12 683 irradiation events, 49.4% and 84.8% of XGBoost-based localized-organ estimates were within ±5% and ±20% of the MC-derived values, respectively. The corresponding proportions were 88.2% and 98.0% for the distributed-tissue estimates and 87.6% and 98.3% for detriment-weighted dose. The median relative prediction error across organs and tissues was 0.37% (interquartile range, −3.68% to 4.99%). A reliability score was developed to support uncertainty-aware interpretation. The framework required approximately 0.3 s per irradiation event, corresponding to an approximately 290-fold acceleration relative to conventional MC simulation under the benchmark conditions. Significance. The proposed image-free framework enables rapid organ-dose estimation when patient imaging is unavailable and may support large retrospective epidemiological studies and uncertainty-aware dose monitoring. Because development and validation were limited to three procedure types and relied on reconstructed phantom-beam geometry, external validation is required before application to other procedures or high-precision individual clinical decisions.

  • Open Access

    HARMONIC organ dose calculation framework for cardiac fluoroscopy

    by Jérémie Dabin, Mahmoud Abdelrahman, David Borrego, Haegin Han, Choonsik Lee, Richard W Harbron, Vadim Chumak, Angeliki Karambatsakidou, Serge Dreuil, I Thierry-Chef

    The HARMONIC study (health effects of cardiac fluoroscopy and modern radiotherapy in paediatrics) aims, among other objectives, to investigate the relationship between ionising radiation and cancer incidence in children treated by cardiac fluoroscopy procedures (HARMONIC-Cardio). This requires estimation of organ doses for a large patient cohort. A framework for accurate dose calculation was developed, and used to create a software tool for rapid dose estimates. Organ doses were calculated with MCNP6.2 Monte Carlo particle transport code. Eight realistic, anthropomorphic phantoms were used representing newborn, 1, 5, 10, 15 year old and adult patients. Only male phantoms were used for patients younger than 15; male and female for older patients). A large range of technical parameters was covered in the simulations, including 11 primary beam angles and seven secondary angles, four levels of beam filtration, three tube voltages and three field sizes. The absorbed dose was computed for 32 organs and tissues. The calculated organ doses were normalised to the air kerma-area product (PKA), a common modality-specific dose index, resulting in PKA-to-organ-dose conversion coefficients. These coefficients were extended by interpolation. Organ dose conversion coefficients were calculated for 22,176 exposure configurations and interpolated to a total of 2,667,600. The coefficients for 15 organs of interest for radiation protection and effective dose were embedded in HARMONIC-CardioDose: a software tool that enables users to estimate organ doses for virtually any exposure scenario within the simulation range. The program is in the form of a Python script or an executable file, and uses a simple Excel document for inputting technical parameters necessary for calculations. HARMONIC-CardioDose is a validated software tool for rapid estimate of organ doses for paediatric and adult patients undergoing interventional cardiology procedures. The tool is freely available to the medical and research community for supporting patient dosimetry

  • ICRP pregnant-female mesh-type reference computational phantoms part 2: development of maternal phantoms

    by Bangho Shin, Suhyeon Kim, Chansoo Choi, Hyeonil Kim, Yeon Soo Yeom, Beom Sun Chung, Thang Tat Nguyen, Wesley E Bolch, Sungho Moon, Haegin Han, et al.

    Objective. In the present study, the pregnant-female mesh-type reference computational phantoms (MRCPs) of the International Commission on Radiological Protection (ICRP) were fully developed in the tetrahedral-mesh format by constructing the maternal phantoms for 8-, 10-, 15-, 20-, 25-, 30-, 35-, and 38 week fetal ages. Approach. The reference blood-inclusive organ dataset (masses, elemental compositions, and densities) and the anthropometric data (rib cage dimensions, spinal curvature and pelvic inclination angle, breast dimensions, and anthropometric parameters) were established, which were then used to develop the maternal phantoms. During the development process, the pregnant-female MRCPs were fully developed by installing the mesh-type fetal phantoms in the maternal uterus considering the shape and position of the fetus. Main results. The dosimetric impact of the phantoms, in terms of fetal dose from maternal radionuclide intake, was investigated by calculating the photon specific absorbed fractions (SAFs) for some selected maternal organs as source regions and the entire fetal phantom as a target region. The results showed that the SAFs for the older fetus were larger than those for the younger fetus when the source-target distance is long, and the opposite trend is observed when the distance is short. These results were observed due to the growth of the fetus. Significance. The pregnant-female MRCPs will serve as the only ICRP reference phantoms representing the pregnant women and fetuses. The comprehensive SAFs dataset will be computed to calculate the ICRP reference dose coefficients for fetal members of the public.


  • Open Access

    Dose coefficients of mesh-type reference Korean phantoms (MRKPs) for idealized external exposure geometries of photons and electrons

    by Sungho Moon, Chansoo Choi, Bangho Shin, Gahee Son, Haegin Han, Hyeonil Kim, Suhyeon Kim, Jaehyo Kim, Yumin Lee, Jong Hwi Jeong, et al.


  • Open Access

    Towards accurate dose assessment for emergency industrial radiography source retrieval operations: A preliminary study of 4D Monte Carlo dose calculations

    by Sungho Moon, Haegin Han, Chansoo Choi, Bangho Shin, Gahee Son, Hyeonil Kim, Suhyeon Kim, Jaehyo Kim, In Gyu Yoon, Kyung Hwan Lee, et al.


  • MPPD: A User-Friendly Posture Deformation Program for Mesh-Type Computational Phantoms

    by Haegin Han, Jaehyo Kim, Sungho Moon, Gahee Son, Bangho Shin, Hyeonil Kim, Suhyeon Kim, Chansoo Choi, Chan Hyeong Kim

    Recently, the International Commission on Radiological Protection (ICRP) released adult Mesh-type Reference Computational Phantoms (MRCPs), which have great advantage in high deformability. Previous studies have exploited their high deformability to investigate the dosimetric influence of varying statures and postures, demonstrating significant variations in radiation doses. However, the previous studies are constrained by their inability to consider both stature and posture concurrently and by the limited range of postures analyzed. In the present study, a computer program named MPPD (Mesh-type Phantom Posture Deformer) was developed, a user-friendly graphical user interface that enables users to adjust the posture of adult MRCPs and corresponding library phantoms. The MPPD program was applied to deform five adult male phantoms of different statures into sitting and kneeling postures, showcasing its rapid computational speed and minimal RAM usage. The effectiveness of the MPPD program for dose calculation was also investigated by computing the detriment-weighted doses for MPPD-deformed adult male MRCPs, which showed good agreement with dose values for existing posture-deformed phantoms of the previous study. Furthermore, as an application of the MPPD program, the combined dosimetric impact of stature and posture was investigated, which is the inaugural effort to estimate doses by considering these factors concurrently. The result showed that the impact of stature and posture on radiation doses could largely vary depending on the radiation source, highlighting the importance of simultaneous consideration of stature and posture for accurate dose estimation.


  • Open Access

    Pediatric phantom library constructed from ICRP mesh-type reference computational phantoms (MRCPs)

    by Suhyeon Kim, Bangho Shin, Chansoo Choi, Hyeonil Kim, Sangseok Ha, Beom Sun Chung, Haegin Han, Sungho Moon, Gahee Son, Jaehyo Kim, et al.


  • Open Access

    Photon dose response functions for accurate skeletal dosimetry for Korean and Asian populations

    by Bangho Shin, Chansoo Choi, Rui Qiu, Suhyeon Kim, Hyeonil Kim, Sungho Moon, Gahee Son, Jaehyo Kim, Haegin Han, Yeon Soo Yeom, et al.


  • Open Access

    TET2DICOM-GUI: Graphical User Interface Based TET2DICOM Program to Convert Tetrahedral-Mesh-Phantom to DICOM-RT Dataset

    by Se Hyung Lee, Bo-Wi Cheon, Chul Hee Min, Haegin Han, Chan Hyeong Kim, Min Cheol Han, Seonghoon Kim

    Se Hyung Lee, Bo-Wi Cheon, Chul Hee Min, Haegin Han, Chan Hyeong Kim, Min Cheol Han, Seonghoon Kim. Progress in Medical Physics 2022;33:172-9. https://doi.org/10.14316/pmp.2022.33.4.172