JIJunya Itou

Junya Itou

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Junya Itou has a total of 26 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Postoperative alignment and patients reported outcome measures improvement after high tibial osteotomy: a significant interaction with osteoarthritis severity

    by Junya Itou, Masafumi Itoh, Umito Kuwashima, Taketoshi Oda, Ken Okazaki

    Purpose Optimal postoperative alignment in high tibial osteotomy (HTO) remains controversial due to inconsistent target definitions and limited evidence supporting osteoarthritis (OA) severity–based strategies. This study evaluated clinical outcomes across postoperative weight-bearing line (WBL) categories stratified by OA severity, hypothesizing that overcorrection would be detrimental in early OA but not in advanced OA. Methods This retrospective single-center study included 181 knees that underwent open-wedge or closed-wedge HTO between 2017 and 2023 with a minimum 2-year follow-up. Knees were classified as early OA (Kellgren–Lawrence [KL] ≤ 2) or advanced OA (KL ≥ 3). The corrective angle was defined as the planned angular change required to shift the mechanical axis to the target postoperative alignment, determined by aiming for a postoperative %WBL of 62.5% on double-limb standing full-length radiographs. Overcorrection was defined as %WBL ≥ 70%. Clinical and radiographic outcomes were assessed at baseline and final follow-up. Multivariable regression models identified factors associated with changes (Δ) in Forgotten Joint Score-12 (FJS-12) and Knee Injury and Osteoarthritis Outcome Score (KOOS), and logistic regression evaluated achievement of minimum clinically important difference (MCID) and patient acceptable symptom state (PASS). Each knee was treated as an independent observational unit. Results Early OA (n = 112) and advanced OA (n = 69) showed comparable baseline characteristics. In early OA, postoperative alignment was significantly associated with ΔFJS‑12 and ΔKOOS Sports. Compared with optimal alignment, overcorrection was associated with smaller improvement in ΔFJS‑12 (β = −10.49, 95% CI − 20.46 to − 0.53) and ΔKOOS Sports, whereas undercorrection did not demonstrate a statistically significant association with postoperative improvement. Overcorrection also reduced the likelihood of achieving MCID and PASS in early OA. In advanced OA, postoperative alignment was not associated with PROM improvements or MCID/PASS achievement. Conclusions Overcorrection was associated with significantly poorer improvement in FJS-12 and KOOS Sports in early OA, whereas postoperative alignment was not associated with differences in PROM improvements in advanced OA. Level of evidence IV.

  • Open Access

    Radiolucent lines after robotic-assisted surface-matching kinematically aligned UKA: short-term incidence and lack of association with tibial alignment

    by Junya Itou, Ayano Kuwasawa, Kotaro Nihei, Ken Okazaki

    Purpose This study investigated the clinical outcomes of robotic-assisted unicompartmental knee arthroplasty (UKA) performed using a surface-matching kinematic technique that restores native joint morphology without alignment constraints. The primary aim was to determine the incidence and distribution of radiolucent lines (RLLs), and the secondary aim was to evaluate short-term revision rates and clinical outcomes. Methods This retrospective cohort study reviewed 242 medial UKAs performed between November 2021 and August 2023 by the same high‑volume surgeon using a surface‑matching technique. Radiographic parameters and patient‑reported outcome measures (PROMs) obtained before and 1 year after surgery were assessed, with radiographic evaluation performed independently of the clinical outcome assessment. A cemented JOURNEY II Uni implant was used in all cases, with intraoperative surface mapping used to guide kinematic placement of components without alignment constraints. Results RLLs were seen in 21.9% of knees, exclusively on the tibial side and mainly in the most medial (zone 1: 14.8%, 95% confidence interval [CI] 10.9–19.9) and posterior regions (zone 9: 15.3%, 95% CI 11.3–20.3). A larger tibial component was the only independent predictor of RLLs (odds ratio 1.54, 95% CI 1.27–1.88; p = 0.04). All PROMs improved, with no differences between knees with and without RLLs. No revisions, infections, or major complications occurred during the short‑term (1‑year) follow‑up. Conclusions In kinematically aligned UKA performed with a surface‑matching technique without restricting tibial varus or posterior slope, RLLs appeared in 21.9% of cases and were concentrated medially on the anteroposterior view and posteriorly on the lateral view. Tibial component size was the only independent risk factor. Short‑term clinical outcomes improved similarly regardless of RLL presence. Level of evidence Level IV.

  • Open Access

    Transverse incisions improve scar outcomes in anterolateral supine approach total hip arthroplasty: a patient observer scar assessment scale-based study

    by Yujiro Kuramitsu, Junya Itou, Yutaro Munakata, Ken Okazaki

    Background: This study compared transverse and longitudinal skin incisions in anterolateral supine (ALS) total hip arthroplasty (THA), focusing on cosmetic and sensory outcomes using the Patient Observer Scar Assessment Scale (POSAS). Methods: A retrospective analysis was conducted on 132 hips that underwent primary ALS THA performed by a single surgeon between 2019 and 2024. Longitudinal incisions were used until December 2022, and transverse incisions aligned with relaxed skin tension lines were used thereafter. POSAS 3.0 was used to evaluate scar quality across satisfaction, appearance, and sensory domains. Results: Baseline characteristics were similar between groups, except for follow-up duration and incision length. No significant differences were found in POSAS scores. However, regression analysis revealed that transverse incision significantly improved satisfaction ( P = 0.04) and appearance ( P < 0.05). Sensory scores were significantly affected by follow-up duration ( P < 0.001). Conclusion: Transverse incisions in ALS THA may enhance cosmetic satisfaction without compromising sensory outcomes. These findings support the potential role of personalized incision planning for improving patient-reported outcomes following THA.

  • The CPAK classification in three‐dimensional measurements is consistent with those in two-dimensional measurements

    by Junya Itou, Imrane Gazali, Hemant Pandit, Ken Okazaki, Daniele Ascani, Geert Peersman

    Purpose This study aimed to evaluate whether the coronal plane alignment of the knee (CPAK) classification between three-dimensional (3D) measurement using computed tomography (CT) and two-dimensional (2D) measurement using long leg radiographs (LLR) match. Methods A retrospective radiographic study compared pre-operative CT and LLR measurements in 69 patients undergoing primary total knee arthroplasty. The arithmetic hip–knee–ankle angle (aHKA), joint line obliquity (JLO), and CPAK types were calculated. A match in the CPAK classification was defined as “complete agreement” and agreement was considered partial if the CPAK was located in an adjacent column. If the discrepancy was more than one column, then it was recorded as no agreement. Results The mean aHKA was − 0.6° ± 4.4° in 3D measurement and − 1.1° ± 4.3° in 2D measurement (p = 0.42). The mean JLO was 174.2° ± 3.5° in 3D measurement and 175.2° ± 3.6° in 2D measurement (p = 0.07). There was no statistically significant difference in either aHKA or JLO obtained by the two measurement methods, each within 1°. However, the complete agreement was confirmed in only 60.8% of cases. After incorporating even partial agreements including neighboring columns, the agreement rate was 91.2%. The disagreement was noticed in 8.8% of the cases. Conclusion The 3D measurement method enables aHKA and JLO calculations similar to those of 2D measurements. However, complete agreement with the CPAK classification in all cases was not obtained. On the other hand, 2D measurement has the advantage that JLO can be easily appreciated and remais more intuitive for surgeons. Level of evidence III.


  • Open Access

    Saddle‐shaped rotating knee prosthesis outperforms low contact stress knee: A short‐term retrospective comparative study

    by Masafumi Itoh, Junya Itou, Umito Kuwashima, Ken Okazaki

    Purpose: This retrospective comparative study aimed to compare the native patellar alignment and clinical outcomes of the Rotating Concave–Convex (ROCC) knee, which features a saddle‐shaped rotating platform (RP) insert and a deep trochlea, versus the low contact stress (LCS) knee, which has favourable long‐term outcomes and features an anatomically shaped trochlea and a cruciate‐sacrificing RP insert. We hypothesized that the deeper trochlea of the ROCC would further stabilize the native patella, resulting in superior clinical outcomes compared to LCS‐RP.Methods: Consecutive patients who underwent patellar‐nonresurfacing primary total knee arthroplasty (TKA) using ROCC or LCS‐RP were retrospectively reviewed. Patients with over 1‐year post‐TKA follow‐up were included. Patients with neurologic disorders affecting knee function or additional ipsilateral knee surgery before evaluation were excluded. Patellar alignment was evaluated using the patella tilting angle (PTA), patella shift (PS), and the ratio of patella fitting depth into the trochlea (F) on axial radiographs. Primary and secondary outcomes were evaluated using the patellar score assessing patellofemoral function and Knee Injury and Osteoarthritis Outcome Score. Multiple regression analyses were performed with primary and secondary outcomes as dependent variables.Results: The analysis included 113 ROCC knees and 94 LCS‐RP knees (median follow‐up: 25 months, follow‐up rate: 92.3%). For ROCC and LCS‐RP, respectively, the mean PTA was 0.3 (3.2)° and 4.3 (2.9)°; PS was 0.5 (1.8) and 2.0 (2.5) mm; and F was 29.6 (8.1)% and 21.4 (6.5)% (all p < 0.001). On multivariate analysis, ROCC positively affected both primary and secondary outcomes (p = 0.004 and 0.0003–0.02, respectively).Conclusion: At short‐term follow‐up, ROCC stabilized the patella further horizontally, centrally, and deeply into the trochlea, thus outperforming LCS‐RP clinically. Orthopaedic surgeons should consider these potential advantages when selecting TKA models, especially those featuring cruciate‐sacrificing RP mechanisms in patellar‐nonresurfacing procedures.Level of Evidence: III. Retrospective comparative study.


  • Open Access

    Large angular correction of arithmetic coronal alignment is associated with residual lateral laxity after total knee arthroplasty in varus knees for Japanese patients

    by Junya Itou, Umito Kuwashima, Masafumi Itoh, Ken Okazaki

    Purpose: One of the most common types of coronal plane alignment of the knee (CPAK) is type I, which is characterised by varus alignment and apex distal joint line obliquity. The purpose of this study was to evaluate the association of changes in arithmetic hip–knee–ankle angle (aHKA) with both postoperative joint laxity and patient‐reported outcome measures (PROMs) in patients with CPAK type I following mechanical alignment (MA) total knee arthroplasty (TKA).Methods: Of 111 consecutive knees in 92 patients with osteoarthritis who underwent primary TKA, 80 knees (72.0%) with CPAK type I phenotype preoperatively were evaluated. All TKAs were performed to achieve neutral MA by a medial stabilising gap balancing technique. Pre‐ to postoperative change in aHKA was defined as ΔaHKA. The 80 CPAK type I knees were divided into a larger ΔaHKA group (>7°) and a smaller ΔaHKA group (≤7°). PROMs, including the Knee Society Score and Forgotten Joint Score‐12, were assessed before and 2 years after surgery. Pre‐ and postoperative joint laxity was assessed using a Telos arthrometer.Results: Twenty‐two knees showed a larger ΔaHKA, and postoperative lateral joint laxity in varus stress was significantly greater in these patients than in those with a smaller ΔaHKA (6.8° vs. 4.5°, p = 0.006). There were no significant differences between the groups in PROMs (p = n.s.).Conclusions: Postoperative lateral laxity was associated with larger aHKA changes than smaller aHKA changes in CPAK type I knees after TKA. However, no statistically significant differences in PROMs were found according to the amount of change in aHKA.Level of Evidence: Level III.


  • Open Access

    Incidence and Distribution of Deep Vein Thrombosis Following Total Hip Arthroplasty Using an Anterolateral Supine Approach

    by Junya Itou, Yutaro Munakata, Yujiro Kuramitsu, Hiromi Madarame, Ken Okazaki

    Purpose: Venous thromboembolism (VTE) is a potential major complication in patients undergoing total hip arthroplasty (THA). However, the incidence of VTE following THA using anterolateral supine approach (ALS) has not been reported. The purpose of this study was to investigate the incidence of perioperative VTE and the distribution and characteristics of deep vein thrombosis (DVT) following ALS THA. Patients and Methods: This retrospective single-arm study analyzed the 182 consecutive hips of 164 patients who underwent primary ALS THA. Pharmacological prophylaxis consisted of enoxaparin 20 mg twice daily for approximately 6 days starting 24 h postoperatively until duplex ultrasonography was performed to determine whether postoperative DVT was present. DVT was assessed by whole-leg Doppler ultrasound, and the location and characteristics of any thrombus were recorded. If pulmonary thromboembolism was suspected, contrast-enhanced computed tomography was performed. Results: The overall incidence of VTE was 9.9% for DVT (18/182 hips) and 0.5% for pulmonary thromboembolism (1/182 hips). Most DVTs were in the soleal vein on the affected side and showed isoechoic or hypoechoic echogenicity. All thrombi were non-floating. Conclusion: Following ALS THA with standard pharmacological prophylaxis and an early weight-bearing protocol, the incidence of perioperative DVT was approximately 10%, mostly occurring in the lower leg.