Shuai Zhang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Shuai Zhang has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
Chang Wang
Department of Gynecology, The Affiliated Hospital of Qingdao University, Qingdao, Shandong Province, People’s Republic of China
1 shared publicationHai-Yang Yu
Department of Radiology, The Affiliated Hospital of Qingdao University, Qingdao, Shandong Province, People’s Republic of China
1 shared publication- Hao Hong
Department of Biotechnology, Beijing Institute of Radiation Medicine, Beijing, People’s Republic of China
1 shared publication Hongjuan Yang
Department of Gynecology, The Affiliated Hospital of Qingdao University, Qingdao, Shandong, China (mainland)
1 shared publicationJin-Wen Jiao
Department of Gynecology, The Affiliated Hospital of Qingdao University, Qingdao, Shandong Province, People’s Republic of China
1 shared publicationJinwen Jiao
Department of Gynecology, The Affiliated Hospital of Qingdao University, Qingdao, Shandong, China (mainland)
1 shared publication
Latest Publications
- Open Access
- 1 January 2021
- Published by Taylor & Francis in Cancer Management and Research
- Vol. ume 13, 329-336
MDCT-Based Radiomics Features for the Differentiation of Serous Borderline Ovarian Tumors and Serous Malignant Ovarian Tumors
Objective: To investigate whether multidetector computed tomography (MDCT)-based radiomics features can discriminate between serous borderline ovarian tumors (SBOTs) and serous malignant ovarian tumors (SMOTs). Patients and Methods: Eighty patients with SBOTs and 102 patients with SMOTs, confirmed by pathology (training set: n = 127; validation set: n = 55) from December 2017 to June 2020, were enrolled in this study. The interclass correlation coefficient (ICC) and least absolute shrinkage and selection operator (LASSO) regression were applied to select radiomics parameters derived from MDCT images on the arterial phase (AP), venous phase (VP), and equilibrium phase (EP). Receiver operating characteristic (ROC) analysis of each selected parameter was carried out. Heat maps were created to illustrate the distribution of the radiomics parameters. Three models incorporating selected radiomics parameters generated by support vector machine (SVM) classifiers in each phase were analyzed by ROC and compared using the DeLong test. Results: The most predictive features selected by ICC and LASSO regression between SBOTs and SMOTs included 9 radiomics parameters on AP, VP, and EP each. Three models on AP, VP, and EP incorporating the selected features generated by SVM classifiers produced AUCs of 0.80 (accuracy, 0.75; sensitivity, 0.74; specificity, 0.75), 0.86 (accuracy, 0.78; sensitivity, 0.80; specificity, 0.75), and 0.73 (accuracy, 0.69; sensitivity, 0.71; specificity, 0.67), respectively. There were no significant differences in the AUCs among the three models (AP vs. VP, P = 0.199; AP vs. EP, P = 0.260; VP vs. EP, P = 0.793). Conclusion: MDCT-based radiomics features could be used as biomarkers for the differentiation of SBOTs and SMOTs.
- 1 January 2021
- Published by Taylor & Francis in Cancer Management and Research
- Vol. ume 13, 329-336
Open AccessMDCT-Based Radiomics Features for the Differentiation of Serous Borderline Ovarian Tumors and Serous Malignant Ovarian Tumors
Objective: To investigate whether multidetector computed tomography (MDCT)-based radiomics features can discriminate between serous borderline ovarian tumors (SBOTs) and serous malignant ovarian tumors (SMOTs). Patients and Methods: Eighty patients with SBOTs and 102 patients with SMOTs, confirmed by pathology (training set: n = 127; validation set: n = 55) from December 2017 to June 2020, were enrolled in this study. The interclass correlation coefficient (ICC) and least absolute shrinkage and selection operator (LASSO) regression were applied to select radiomics parameters derived from MDCT images on the arterial phase (AP), venous phase (VP), and equilibrium phase (EP). Receiver operating characteristic (ROC) analysis of each selected parameter was carried out. Heat maps were created to illustrate the distribution of the radiomics parameters. Three models incorporating selected radiomics parameters generated by support vector machine (SVM) classifiers in each phase were analyzed by ROC and compared using the DeLong test. Results: The most predictive features selected by ICC and LASSO regression between SBOTs and SMOTs included 9 radiomics parameters on AP, VP, and EP each. Three models on AP, VP, and EP incorporating the selected features generated by SVM classifiers produced AUCs of 0.80 (accuracy, 0.75; sensitivity, 0.74; specificity, 0.75), 0.86 (accuracy, 0.78; sensitivity, 0.80; specificity, 0.75), and 0.73 (accuracy, 0.69; sensitivity, 0.71; specificity, 0.67), respectively. There were no significant differences in the AUCs among the three models (AP vs. VP, P = 0.199; AP vs. EP, P = 0.260; VP vs. EP, P = 0.793). Conclusion: MDCT-based radiomics features could be used as biomarkers for the differentiation of SBOTs and SMOTs.
- 17 August 2020
- Published by International Scientific Information, Inc. in Medical Science Monitor
- Vol. 26, e924497-1-e924497-9
Evaluation of Ovarian Tumors with Multidetector Computed Tomography and Tumor Markers: Differentiation of Stage I Serous Borderline Tumors and Stage I Serous Malignant Tumors Presenting as Solid-Cystic Mass
Background: The aim of this study was to determine multidetector computed tomography (MDCT) features and tumor markers for differentiating stage I serous borderline ovarian tumors (SBOTs) from stage I serous malignant ovarian tumors (SMOTs). Material/Methods: In total, 48 patients with stage I SBOTs and 54 patients with stage I SMOTs who underwent MDCT and tumor markers analysis were analyzed. MDCT features included location, shape, margins, texture, papillary projections, vascular abnormalities, size, and attenuation value. Tumor markers included serum cancer antigen 125 (CA125), carbohydrate antigen 19-9 (CA19-9), carcinoembryonic antigen (CEA), and human epididymis protein 4 (HE4). Parameters of clinical characteristic, MDCT features, and tumor markers were compared using a chi-square test and Mann-Whitney U tests. A binary logistic regression analysis was performed to detect predictors for SMOTs. A receiver operating characteristic (ROC) curve analysis was used to assess the potential diagnostic value of the quantitative parameters. Kappa and intraclass correlation coefficients were used to evaluate interobserver reproducibility for MDCT features. Results: Median ages between patients with SBOTs and SMOTs were significantly different. Compared with SBOTs, vascular abnormalities were significantly more common in SMOTs. CA125, HE4, the maximum thickness of the wall, the maximum thickness of the septa, and the maximum diameter of the solid portions were significantly higher in patients with SMOTs. A binary logistic regression analysis revealed that age, vascular abnormalities, and the maximum diameter of the solid portion were independent factors of SMOTs. ROC analysis was used to assess the potential diagnostic value for predicting SMOTs. Moderate or good interobserver reproducibility for MDCT features were identified. Conclusions: Age, vascular abnormalities, and the maximum diameter of the solid portion were independent factors for differentiating SBOTs from SMOTs. The combined analysis of age, vascular abnormalities, and the maximum diameter of the solid portion may allow better differentiation between SBOTs and SMOTs.
- 17 August 2020
- Published by International Scientific Information, Inc. in Medical Science Monitor
- Vol. 26, e924497-1-e924497-9
Evaluation of Ovarian Tumors with Multidetector Computed Tomography and Tumor Markers: Differentiation of Stage I Serous Borderline Tumors and Stage I Serous Malignant Tumors Presenting as Solid-Cystic Mass
Background: The aim of this study was to determine multidetector computed tomography (MDCT) features and tumor markers for differentiating stage I serous borderline ovarian tumors (SBOTs) from stage I serous malignant ovarian tumors (SMOTs). Material/Methods: In total, 48 patients with stage I SBOTs and 54 patients with stage I SMOTs who underwent MDCT and tumor markers analysis were analyzed. MDCT features included location, shape, margins, texture, papillary projections, vascular abnormalities, size, and attenuation value. Tumor markers included serum cancer antigen 125 (CA125), carbohydrate antigen 19-9 (CA19-9), carcinoembryonic antigen (CEA), and human epididymis protein 4 (HE4). Parameters of clinical characteristic, MDCT features, and tumor markers were compared using a chi-square test and Mann-Whitney U tests. A binary logistic regression analysis was performed to detect predictors for SMOTs. A receiver operating characteristic (ROC) curve analysis was used to assess the potential diagnostic value of the quantitative parameters. Kappa and intraclass correlation coefficients were used to evaluate interobserver reproducibility for MDCT features. Results: Median ages between patients with SBOTs and SMOTs were significantly different. Compared with SBOTs, vascular abnormalities were significantly more common in SMOTs. CA125, HE4, the maximum thickness of the wall, the maximum thickness of the septa, and the maximum diameter of the solid portions were significantly higher in patients with SMOTs. A binary logistic regression analysis revealed that age, vascular abnormalities, and the maximum diameter of the solid portion were independent factors of SMOTs. ROC analysis was used to assess the potential diagnostic value for predicting SMOTs. Moderate or good interobserver reproducibility for MDCT features were identified. Conclusions: Age, vascular abnormalities, and the maximum diameter of the solid portion were independent factors for differentiating SBOTs from SMOTs. The combined analysis of age, vascular abnormalities, and the maximum diameter of the solid portion may allow better differentiation between SBOTs and SMOTs.