Timothy P. Turkstra
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Timothy P. Turkstra has a total of 4 co-authors. Here are the top co-authors by number of shared publications:
Alexander W. Pavlosky
Department of Family Medicine, Schulich School of Medicine & Dentistry, University of Western Ontario, London, Canada
1 shared publicationDaniel C. Turkstra
Department of Mechanical Engineering, University of Ottawa, Ottawa, Canada
1 shared publication- Philip M. Jones
Departments of Anesthesia & Perioperative Medicine and Epidemiology & Biostatistics, University of Western Ontario, London, Canada
1 shared publication William D. Regan
Western University, London, Canada
1 shared publication
Latest Publications
- 28 September 2021
- Published by Springer Nature in Canadian Journal of Anesthesia/Journal canadien d'anesthésie
- Vol. 69 (1) , 177-178
Provider/patient conflict: is it time to reconsider the contraindication for videolaryngoscope use in a bleeding/soiled airway?
- 28 September 2021
- Published by Springer Nature in Canadian Journal of Anesthesia/Journal canadien d'anesthésie
- Vol. 69 (1) , 177-178
Provider/patient conflict: is it time to reconsider the contraindication for videolaryngoscope use in a bleeding/soiled airway?
- Open Access
- 19 August 2020
- Published by Springer Nature in Canadian Journal of Anesthesia/Journal canadien d'anesthésie
- Vol. 67 (11) , 1515-1523
Simultaneous en bloc endotracheal tube insertion with GlideScope® Titanium™ video laryngoscope use: a randomized-controlled trial
Purpose Intubation-associated trauma with the GlideScope is rare, but when it occurs, it is likely due to advancing the endotracheal tube (ETT) blindly between the direct view of the oropharynx and the video view of the glottis. It is also occasionally difficult to advance the ETT to the glottic aperture despite a good view of the glottis on the monitor. One technique to potentially address both issues is to introduce the ETT en bloc with the GlideScope, thus visualizing the ETT tip throughout its entire path. We hypothesized that this en bloc technique could be faster and potentially easier than the standard technique. Methods Fifty patients with normal-appearing airways who required orotracheal intubation for elective surgery were randomly allocated to intubation with either the en bloc or the standard (GlideScope-first-then-ETT) technique. A three-dimensional printed clip was utilized to secure the ETT to the GlideScope during en bloc insertion. The primary outcome was time to intubation, defined from mask removal to first end-tidal carbon dioxide detection, recorded by a blinded observer. Secondary outcomes were subjective ease of intubation (100-mm visual analogue scale [VAS], 0 = easy; 100 = difficult), number of intubation attempts/failures, and incidence of oropharyngeal trauma (bleeding). Results The median [interquartile range (IQR)] intubation time was 36 [31–42] sec with the en bloc technique vs 41 [37–50] sec with the standard technique (difference in medians, 5 sec; 95% confidence interval [CI], 2 to 11; P = 0.008). The median [IQR] ease of intubation VAS was 11 [9–21] mm with the en bloc technique, and 15 [11–24] mm with the standard technique (difference in medians, 4 mm; 95% CI, −2 to 8; P = 0.19). Laryngoscopic grade and number of intubation attempts were similar between the groups; there was no oropharyngeal trauma noted. Conclusion In this study of video laryngoscopy, intubation was slightly faster with the en bloc technique than with the standard GlideScope intubation technique, although the clinical importance of this difference is unknown. Trial registration www.clinicaltrials.gov (NCT02787629); registered 1 June 2016.
- 19 August 2020
- Published by Springer Nature in Canadian Journal of Anesthesia/Journal canadien d'anesthésie
- Vol. 67 (11) , 1515-1523
Open AccessSimultaneous en bloc endotracheal tube insertion with GlideScope® Titanium™ video laryngoscope use: a randomized-controlled trial
Purpose Intubation-associated trauma with the GlideScope is rare, but when it occurs, it is likely due to advancing the endotracheal tube (ETT) blindly between the direct view of the oropharynx and the video view of the glottis. It is also occasionally difficult to advance the ETT to the glottic aperture despite a good view of the glottis on the monitor. One technique to potentially address both issues is to introduce the ETT en bloc with the GlideScope, thus visualizing the ETT tip throughout its entire path. We hypothesized that this en bloc technique could be faster and potentially easier than the standard technique. Methods Fifty patients with normal-appearing airways who required orotracheal intubation for elective surgery were randomly allocated to intubation with either the en bloc or the standard (GlideScope-first-then-ETT) technique. A three-dimensional printed clip was utilized to secure the ETT to the GlideScope during en bloc insertion. The primary outcome was time to intubation, defined from mask removal to first end-tidal carbon dioxide detection, recorded by a blinded observer. Secondary outcomes were subjective ease of intubation (100-mm visual analogue scale [VAS], 0 = easy; 100 = difficult), number of intubation attempts/failures, and incidence of oropharyngeal trauma (bleeding). Results The median [interquartile range (IQR)] intubation time was 36 [31–42] sec with the en bloc technique vs 41 [37–50] sec with the standard technique (difference in medians, 5 sec; 95% confidence interval [CI], 2 to 11; P = 0.008). The median [IQR] ease of intubation VAS was 11 [9–21] mm with the en bloc technique, and 15 [11–24] mm with the standard technique (difference in medians, 4 mm; 95% CI, −2 to 8; P = 0.19). Laryngoscopic grade and number of intubation attempts were similar between the groups; there was no oropharyngeal trauma noted. Conclusion In this study of video laryngoscopy, intubation was slightly faster with the en bloc technique than with the standard GlideScope intubation technique, although the clinical importance of this difference is unknown. Trial registration www.clinicaltrials.gov (NCT02787629); registered 1 June 2016.