Ahmed A. Holiel
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Ahmed A. Holiel has a total of 79 co-authors. Here are the top co-authors by number of shared publications:
- Carlos Enrique Cuevas-Suárez
Dental Materials Laboratory, Academic Area of Dentistry Autonomous University of Hidalgo State San Agustín Tlaxiaca Mexico
9 shared publications - Rim Bourgi
Department of Biomaterials and Bioengineering, INSERM UMR_S 1121, University of Strasbourg, 67000 Strasbourg, France
7 shared publications - Naji Kharouf
Department of Biomaterials and Bioengineering, INSERM UMR_S 1121, University of Strasbourg, 67000 Strasbourg, France
6 shared publications - Louis Hardan
Department of Restorative and Esthetic Dentistry, Faculty of Dental Medicine, Saint-Joseph University of Beirut, Beirut 1107 2180, Lebanon
5 shared publications Eman M. Sedek
Dental Biomaterials Department, Faculty of Dentistry, Alexandria University, Alexandria, Egypt
4 shared publications- Nicolas Nassar
Department of Orthodontics, Faculty of Dental Medicine, Saint-Joseph University of Beirut, Beirut 1107 2180, Lebanon
4 shared publications
Latest Publications
- 29 October 2026
- Published by Wiley in Journal of Esthetic and Restorative Dentistry
Substrate‐Driven Adhesive Strategies for Durable Bonding to Coronal and Radicular Dentin Following Endodontic Procedures: A Systematic Review of In Vitro Evidence
Objectives: To evaluate substrate‐directed strategies affecting the durability of adhesive bonding to coronal and radicular dentin following endodontic procedures based on in vitro evidence. Materials and Methods: A systematic search (PubMed, Scopus, Web of Science, EMBASE) identified in vitro studies assessing bond strength to human permanent coronal or radicular dentin following documented endodontic intervention. Eligible studies evaluated radicular dentin for fiber‐post bonding or coronal/pulp‐chamber dentin for direct restorative bonding under artificial aging conditions. Data on dentin pretreatment, adhesive systems, resin cements, and bond strength outcomes were extracted. Risk of bias was evaluated using ROBDEMat. Due to methodological heterogeneity, a narrative synthesis was performed. Results: Twenty‐four studies were included (21 fiber post; 3 coronal dentin). Risk of bias was low in 42%, moderate in 54%, and high in 4% of studies. In radicular dentin, chlorhexidine (CHX), ethanol wet bonding, EDTA conditioning, and collagen cross‐linkers (carbodiimide (EDC) and dimethyl sulfoxide (DMSO)) generally improved aged bond durability, particularly in cervical regions. Ultrasonic and laser‐assisted activation enhanced smear layer removal and interfacial adaptation. Resin cement performance varied with substrate condition, with 10‐MDP–containing systems showing superior stability. Limited coronal/pulp‐chamber evidence suggested potential benefits of short‐term CHX and mild chelating/acidic pretreatments, with more consistent aging performance observed for two‐step self‐etch approaches in selected experimental conditions. Conclusions: Bond durability following endodontic procedures is strongly substrate dependent. Stable adhesion is promoted by collagen preservation, optimized smear layer management, and chemically interactive adhesive systems. However, substantial heterogeneity among in vitro studies, together with the exclusively in vitro nature of the evidence, limits direct comparability and precludes clinical standardization. Clinical Significance: Substrate‐directed pretreatment strategies, when combined with appropriate adhesive selection, may enhance the longevity of bonded restorations following endodontic procedures by reducing degradation at the resin–dentin interface.
- 29 October 2026
- Published by Wiley in Journal of Esthetic and Restorative Dentistry
Substrate‐Driven Adhesive Strategies for Durable Bonding to Coronal and Radicular Dentin Following Endodontic Procedures: A Systematic Review of In Vitro Evidence
Objectives: To evaluate substrate‐directed strategies affecting the durability of adhesive bonding to coronal and radicular dentin following endodontic procedures based on in vitro evidence. Materials and Methods: A systematic search (PubMed, Scopus, Web of Science, EMBASE) identified in vitro studies assessing bond strength to human permanent coronal or radicular dentin following documented endodontic intervention. Eligible studies evaluated radicular dentin for fiber‐post bonding or coronal/pulp‐chamber dentin for direct restorative bonding under artificial aging conditions. Data on dentin pretreatment, adhesive systems, resin cements, and bond strength outcomes were extracted. Risk of bias was evaluated using ROBDEMat. Due to methodological heterogeneity, a narrative synthesis was performed. Results: Twenty‐four studies were included (21 fiber post; 3 coronal dentin). Risk of bias was low in 42%, moderate in 54%, and high in 4% of studies. In radicular dentin, chlorhexidine (CHX), ethanol wet bonding, EDTA conditioning, and collagen cross‐linkers (carbodiimide (EDC) and dimethyl sulfoxide (DMSO)) generally improved aged bond durability, particularly in cervical regions. Ultrasonic and laser‐assisted activation enhanced smear layer removal and interfacial adaptation. Resin cement performance varied with substrate condition, with 10‐MDP–containing systems showing superior stability. Limited coronal/pulp‐chamber evidence suggested potential benefits of short‐term CHX and mild chelating/acidic pretreatments, with more consistent aging performance observed for two‐step self‐etch approaches in selected experimental conditions. Conclusions: Bond durability following endodontic procedures is strongly substrate dependent. Stable adhesion is promoted by collagen preservation, optimized smear layer management, and chemically interactive adhesive systems. However, substantial heterogeneity among in vitro studies, together with the exclusively in vitro nature of the evidence, limits direct comparability and precludes clinical standardization. Clinical Significance: Substrate‐directed pretreatment strategies, when combined with appropriate adhesive selection, may enhance the longevity of bonded restorations following endodontic procedures by reducing degradation at the resin–dentin interface.
- Open Access
- 23 June 2026
- Published by SAGE Publications in Biomedical Engineering and Computational Biology
- Vol. 17
Accuracy and Functional Performance of Artificial Intelligence-Based Automated Crown Design Systems: A Systematic Review and Meta-Analysis
Objectives: Artificial intelligence (AI)-driven automated crown design is rapidly transforming digital restorative dentistry by enabling anatomically precise and functionally integrated crowns. This systematic review and meta-analysis critically evaluate whether AI-assisted crown design systems, including machine learning (ML), deep learning (DL), generative adversarial networks (GANs), and diffusion models, produce restorations with comparable or superior morphological accuracy, occlusal integration, internal fit, and workflow efficiency relative to computer-aided design (CAD) or technician-driven workflows. Methods: A comprehensive search of MEDLINE (PubMed), Scopus, Web of Science, Embase, and Cochrane Library was conducted for studies published through 17 March 2026. Eligible studies included in vitro, in silico, and clinical investigations comparing AI-based crown design systems with conventional workflows. Primary outcomes were morphological accuracy root-mean-square (RMS) deviation, cusp morphology, volumetric/linear deviation, occlusal contact fidelity, and internal fit; secondary outcomes included marginal adaptation and restoration design time. Risk of bias was assessed using validated tools, and meta-analyses were conducted using random-effects models with standardized mean differences (SMDs). Results: Seventeen studies met the inclusion criteria, of which 13 were included in the quantitative synthesis. AI-based systems achieved clinically acceptable morphological accuracy, internal fit, and occlusal contact reproduction (RMS deviation: SMD = −0.15, 95% CI −1.04 to 0.74). Workflow efficiency improved significantly, with reductions in design time of 25-50% and enhanced precision in chamfer and marginal gaps (p < 0.001). DL and GAN-based platforms consistently produced crowns within clinically acceptable deviation ranges (<100–200 μm). Integration of patient-specific occlusal and mandibular dynamics further enhanced functional occlusal prediction. Expert technician refinement remained beneficial in anatomically complex cases. Conclusions: AI-assisted crown design demonstrates promising potential for providing reproducible, morphologically accurate, and functionally integrated restorations while potentially enhancing workflow efficiency. This review underscores the potential of AI systems to standardize restorative outcomes and reduce operator dependency, while combined human-AI workflows may enhance performance in complex cases. However, the current evidence is derived predominantly from in vitro and computational studies, with limited prospective clinical validation, limited integration of patient-specific dynamic occlusal data, and insufficient long-term follow-up evidence. Therefore, the findings should be interpreted cautiously and not considered definitive evidence of clinical superiority over conventional workflows. Standardized clinical protocols and prospective trials are required to confirm long-term efficacy.
- 23 June 2026
- Published by SAGE Publications in Biomedical Engineering and Computational Biology
- Vol. 17
Open AccessAccuracy and Functional Performance of Artificial Intelligence-Based Automated Crown Design Systems: A Systematic Review and Meta-Analysis
Objectives: Artificial intelligence (AI)-driven automated crown design is rapidly transforming digital restorative dentistry by enabling anatomically precise and functionally integrated crowns. This systematic review and meta-analysis critically evaluate whether AI-assisted crown design systems, including machine learning (ML), deep learning (DL), generative adversarial networks (GANs), and diffusion models, produce restorations with comparable or superior morphological accuracy, occlusal integration, internal fit, and workflow efficiency relative to computer-aided design (CAD) or technician-driven workflows. Methods: A comprehensive search of MEDLINE (PubMed), Scopus, Web of Science, Embase, and Cochrane Library was conducted for studies published through 17 March 2026. Eligible studies included in vitro, in silico, and clinical investigations comparing AI-based crown design systems with conventional workflows. Primary outcomes were morphological accuracy root-mean-square (RMS) deviation, cusp morphology, volumetric/linear deviation, occlusal contact fidelity, and internal fit; secondary outcomes included marginal adaptation and restoration design time. Risk of bias was assessed using validated tools, and meta-analyses were conducted using random-effects models with standardized mean differences (SMDs). Results: Seventeen studies met the inclusion criteria, of which 13 were included in the quantitative synthesis. AI-based systems achieved clinically acceptable morphological accuracy, internal fit, and occlusal contact reproduction (RMS deviation: SMD = −0.15, 95% CI −1.04 to 0.74). Workflow efficiency improved significantly, with reductions in design time of 25-50% and enhanced precision in chamfer and marginal gaps (p < 0.001). DL and GAN-based platforms consistently produced crowns within clinically acceptable deviation ranges (<100–200 μm). Integration of patient-specific occlusal and mandibular dynamics further enhanced functional occlusal prediction. Expert technician refinement remained beneficial in anatomically complex cases. Conclusions: AI-assisted crown design demonstrates promising potential for providing reproducible, morphologically accurate, and functionally integrated restorations while potentially enhancing workflow efficiency. This review underscores the potential of AI systems to standardize restorative outcomes and reduce operator dependency, while combined human-AI workflows may enhance performance in complex cases. However, the current evidence is derived predominantly from in vitro and computational studies, with limited prospective clinical validation, limited integration of patient-specific dynamic occlusal data, and insufficient long-term follow-up evidence. Therefore, the findings should be interpreted cautiously and not considered definitive evidence of clinical superiority over conventional workflows. Standardized clinical protocols and prospective trials are required to confirm long-term efficacy.
- Open Access
- 14 May 2026
- Published by Elsevier in Dentistry Review
- Vol. 6 (2)
Polyethylene fiber reinforcement in resin composite restorations: A systematic review of clinical trials
- 14 May 2026
- Published by Elsevier in Dentistry Review
- Vol. 6 (2)
Open AccessPolyethylene fiber reinforcement in resin composite restorations: A systematic review of clinical trials
- Open Access
- 28 February 2026
- Published by Korean Academy of Conservative Dentistry in Restorative Dentistry & Endodontics
- Vol. 51 (1) , e12
Bonding and fractographic characterization of universal adhesives applied to dentin in multimode strategies: an in vitro study
Bonding and fractographic characterization of universal adhesives applied to dentin in multimode strategies: an in vitro study
- 28 February 2026
- Published by Korean Academy of Conservative Dentistry in Restorative Dentistry & Endodontics
- Vol. 51 (1) , e12
Open AccessBonding and fractographic characterization of universal adhesives applied to dentin in multimode strategies: an in vitro study
Bonding and fractographic characterization of universal adhesives applied to dentin in multimode strategies: an in vitro study
- Open Access
- 27 February 2026
- Published by MDPI AG in Clinics and Practice
- Vol. 16 (3) , 51
Enamel Integrity and Residual Composite Following Clear Aligner Attachment Removal: A Systematic Review
Objectives: This systematic review evaluated enamel surface alterations and residual composite following the removal of clear aligner attachments, with particular emphasis on the influence of removal techniques, instrument selection, operator experience, and the use of magnification on enamel preservation and cleaning efficiency. Methods: A comprehensive electronic search was performed in PubMed, Scopus, Embase, Web of Science, and Scielo up to October 2025. In vitro, ex vivo, and clinical studies assessing enamel loss, residual composite, surface roughness, or removal time after clear aligner attachment removal were included. Study selection, data extraction, and methodological assessment followed the PRISMA 2020 guidelines and Cochrane Handbook recommendations. Risk of bias was evaluated using a modified Joanna Briggs Institute checklist for laboratory-based studies. Due to substantial methodological heterogeneity, a narrative synthesis was conducted. Results: Of 656 identified records, three in vitro/ex vivo studies were assessed for eligibility. Reported enamel loss ranged from approximately 15 µm to more than 50 µm, depending on the removal protocol and visualization conditions. Residual composite covered approximately 20–40% of the treated enamel surface. Multi-step protocols combining tungsten carbide burs with silicone polishers under magnification demonstrated the most favorable balance between composite removal efficiency and enamel preservation. Fiberglass burs were associated with smoother enamel surfaces but increased enamel loss, whereas one-step polishing systems (OneGloss, Enhance, SM104) resulted in reduced surface roughness and shorter procedural time. The use of magnification loupes (≥2.5×) consistently improved removal precision and reduced residual composite. Meta-analysis was not feasible due to heterogeneity in outcome measures and testing methodologies. Overall risk of bias was deemed acceptable. Conclusions: Based on the limited number of available in vitro/ex vivo studies, removal of clear aligner attachments appears to be associated with measurable enamel loss and residual composite, largely influenced by the instruments and visualization aids used. Sequential carbide–silicone polishing protocols performed under magnification appear promising based on limited in vitro/ex vivo evidence, demonstrating a favorable balance between composite removal and enamel preservation under controlled laboratory conditions. However, given the scarcity of evidence and absence of clinical trials, these findings cannot be directly extrapolated to routine clinical practice. Further well-designed studies are required before definitive clinical recommendations can be established.
- 27 February 2026
- Published by MDPI AG in Clinics and Practice
- Vol. 16 (3) , 51
Open AccessEnamel Integrity and Residual Composite Following Clear Aligner Attachment Removal: A Systematic Review
Objectives: This systematic review evaluated enamel surface alterations and residual composite following the removal of clear aligner attachments, with particular emphasis on the influence of removal techniques, instrument selection, operator experience, and the use of magnification on enamel preservation and cleaning efficiency. Methods: A comprehensive electronic search was performed in PubMed, Scopus, Embase, Web of Science, and Scielo up to October 2025. In vitro, ex vivo, and clinical studies assessing enamel loss, residual composite, surface roughness, or removal time after clear aligner attachment removal were included. Study selection, data extraction, and methodological assessment followed the PRISMA 2020 guidelines and Cochrane Handbook recommendations. Risk of bias was evaluated using a modified Joanna Briggs Institute checklist for laboratory-based studies. Due to substantial methodological heterogeneity, a narrative synthesis was conducted. Results: Of 656 identified records, three in vitro/ex vivo studies were assessed for eligibility. Reported enamel loss ranged from approximately 15 µm to more than 50 µm, depending on the removal protocol and visualization conditions. Residual composite covered approximately 20–40% of the treated enamel surface. Multi-step protocols combining tungsten carbide burs with silicone polishers under magnification demonstrated the most favorable balance between composite removal efficiency and enamel preservation. Fiberglass burs were associated with smoother enamel surfaces but increased enamel loss, whereas one-step polishing systems (OneGloss, Enhance, SM104) resulted in reduced surface roughness and shorter procedural time. The use of magnification loupes (≥2.5×) consistently improved removal precision and reduced residual composite. Meta-analysis was not feasible due to heterogeneity in outcome measures and testing methodologies. Overall risk of bias was deemed acceptable. Conclusions: Based on the limited number of available in vitro/ex vivo studies, removal of clear aligner attachments appears to be associated with measurable enamel loss and residual composite, largely influenced by the instruments and visualization aids used. Sequential carbide–silicone polishing protocols performed under magnification appear promising based on limited in vitro/ex vivo evidence, demonstrating a favorable balance between composite removal and enamel preservation under controlled laboratory conditions. However, given the scarcity of evidence and absence of clinical trials, these findings cannot be directly extrapolated to routine clinical practice. Further well-designed studies are required before definitive clinical recommendations can be established.
- Open Access
- 3 February 2026
- Published by Wiley in Clinical and Experimental Dental Research
- Vol. 12 (1) , e70299
Atraumatic Versus Silver‐Modified Atraumatic Restorative Treatment in Primary Molars: A Randomized Clinical Trial on Minimally Invasive Caries Management and Oral Health‐Related Quality of Life
Objectives: To compare the 6‐month clinical success of atraumatic restorative treatment (ART) and silver‐modified atraumatic restorative treatment (SMART) in primary molars of children with early childhood caries (ECC), and to assess the impact of these treatments on oral health‐related quality of life (OHRQoL). Materials and Methods: A randomized controlled split‐mouth trial included 32 children (aged 3–7 years) with 68 primary molars exhibiting active dentin carious lesions (ICDAS II scores 4 or 5). Each child received one ART restoration using high‐viscosity glass ionomer cement and one SMART restoration with silver diamine fluoride, followed by HVGIC in the same session. Clinical success was assessed after 6 months, using modified ART criteria. Parents completed the Arabic version of the Early Childhood Oral Health Impact Scale (A‐ECOHIS) at baseline and after 6 months to assess changes in OHRQoL. Data analysis included chi‐square, Fisher's exact test, Student's t ‐test with effect sizes reported, and a significance level set at 95%. Results: Of the 68 restorations (34 ART, 34 SMART), 6‐month success rates were 67.6% for ART and 70.5% for SMART, with no statistically significant difference ( p = 0.66). SMART showed slightly better caries arrest. Class I restorations had higher success rates than Class II for both techniques. Failures were mainly due to wear and marginal integrity loss. Mean ECOHIS scores improved from 16.9 at baseline to 10.13 at 6 months, though the change was not statistically significant ( p = 0.125). Conclusion: SMART and ART techniques showed similar short‐term clinical outcomes, with SMART showing a minor, nonsignificant advantage in caries management. Failures in ART were more often linked to active caries and pulp involvement, suggesting that SMART may enhance caries arrest. Placement of both restorations did not significantly affect OHRQoL. Clinical Significance: Incorporating SDF may improve caries arrest and the effectiveness of GIC restorations in primary molars. Trial Registration: ClinicalTrials.gov identifier: NCT07023939.
- 3 February 2026
- Published by Wiley in Clinical and Experimental Dental Research
- Vol. 12 (1) , e70299
Open AccessAtraumatic Versus Silver‐Modified Atraumatic Restorative Treatment in Primary Molars: A Randomized Clinical Trial on Minimally Invasive Caries Management and Oral Health‐Related Quality of Life
Objectives: To compare the 6‐month clinical success of atraumatic restorative treatment (ART) and silver‐modified atraumatic restorative treatment (SMART) in primary molars of children with early childhood caries (ECC), and to assess the impact of these treatments on oral health‐related quality of life (OHRQoL). Materials and Methods: A randomized controlled split‐mouth trial included 32 children (aged 3–7 years) with 68 primary molars exhibiting active dentin carious lesions (ICDAS II scores 4 or 5). Each child received one ART restoration using high‐viscosity glass ionomer cement and one SMART restoration with silver diamine fluoride, followed by HVGIC in the same session. Clinical success was assessed after 6 months, using modified ART criteria. Parents completed the Arabic version of the Early Childhood Oral Health Impact Scale (A‐ECOHIS) at baseline and after 6 months to assess changes in OHRQoL. Data analysis included chi‐square, Fisher's exact test, Student's t ‐test with effect sizes reported, and a significance level set at 95%. Results: Of the 68 restorations (34 ART, 34 SMART), 6‐month success rates were 67.6% for ART and 70.5% for SMART, with no statistically significant difference ( p = 0.66). SMART showed slightly better caries arrest. Class I restorations had higher success rates than Class II for both techniques. Failures were mainly due to wear and marginal integrity loss. Mean ECOHIS scores improved from 16.9 at baseline to 10.13 at 6 months, though the change was not statistically significant ( p = 0.125). Conclusion: SMART and ART techniques showed similar short‐term clinical outcomes, with SMART showing a minor, nonsignificant advantage in caries management. Failures in ART were more often linked to active caries and pulp involvement, suggesting that SMART may enhance caries arrest. Placement of both restorations did not significantly affect OHRQoL. Clinical Significance: Incorporating SDF may improve caries arrest and the effectiveness of GIC restorations in primary molars. Trial Registration: ClinicalTrials.gov identifier: NCT07023939.
- Open Access
- 9 January 2026
- Published by MDPI AG in Journal of Composites Science
- Vol. 10 (1) , 39
A Systematic Review and Meta-Analysis on the Clinical Performance and Longevity of Bioactive Composite Resin Restorations
Background: Bioactive composite resins combine the esthetic and mechanical properties of resin composites with therapeutic functions such as ion release, remineralization, and caries inhibition. While in vitro studies suggest promising bioactivity, their clinical performance in permanent teeth remains uncertain. Objective: This systematic review and meta-analysis critically appraised randomized controlled trials and prospective clinical studies to determine whether bioactive composites offer superior clinical performance compared to conventional resin composites and glass ionomer-based materials. Methods: Electronic databases (PubMed/MEDLINE, Scopus, Web of Science, Google Scholar) were searched for eligible studies (2018–2025). Clinical outcomes assessed restoration survival, marginal integrity, secondary caries, postoperative sensitivity, and esthetic outcomes (color match). Data were pooled using a random-effects model, and risk of bias was assessed with Cochrane criteria. Results: Twenty-two trials met the inclusion criteria. No significant differences were found between bioactive and control restorations for survival/retention (RD = 0.01; 95% CI, –0.01 to 0.03), marginal adaptation (RD = 0.02; 95% CI, –0.02 to 0.06), secondary caries (RD = 0.01; 95% CI, –0.01 to 0.03), or postoperative sensitivity (RD = 0.01; 95% CI, –0.02 to 0.04), with negligible heterogeneity (I2 = 0–4%). For color match, glass ionomer restorations showed significantly poorer outcomes (RD = –0.23; 95% CI, –0.31 to –0.14; p < 0.00001; I2 = 98%), while conventional resin composites had a slight but significant advantage over bioactive composites (RD = 0.07; 95% CI, 0.02 to 0.12; p = 0.003; I2 = 76%). Most studies presented moderate risk of bias and short-term follow-up (<36 months). Conclusions: Current evidence indicates that bioactive composites perform comparably, but not superior, to conventional restoratives in permanent teeth. The discrepancy between laboratory bioactivity and clinical effectiveness highlights the need for long-term, well-designed clinical trials with standardized outcome reporting.
- 9 January 2026
- Published by MDPI AG in Journal of Composites Science
- Vol. 10 (1) , 39
Open AccessA Systematic Review and Meta-Analysis on the Clinical Performance and Longevity of Bioactive Composite Resin Restorations
Background: Bioactive composite resins combine the esthetic and mechanical properties of resin composites with therapeutic functions such as ion release, remineralization, and caries inhibition. While in vitro studies suggest promising bioactivity, their clinical performance in permanent teeth remains uncertain. Objective: This systematic review and meta-analysis critically appraised randomized controlled trials and prospective clinical studies to determine whether bioactive composites offer superior clinical performance compared to conventional resin composites and glass ionomer-based materials. Methods: Electronic databases (PubMed/MEDLINE, Scopus, Web of Science, Google Scholar) were searched for eligible studies (2018–2025). Clinical outcomes assessed restoration survival, marginal integrity, secondary caries, postoperative sensitivity, and esthetic outcomes (color match). Data were pooled using a random-effects model, and risk of bias was assessed with Cochrane criteria. Results: Twenty-two trials met the inclusion criteria. No significant differences were found between bioactive and control restorations for survival/retention (RD = 0.01; 95% CI, –0.01 to 0.03), marginal adaptation (RD = 0.02; 95% CI, –0.02 to 0.06), secondary caries (RD = 0.01; 95% CI, –0.01 to 0.03), or postoperative sensitivity (RD = 0.01; 95% CI, –0.02 to 0.04), with negligible heterogeneity (I2 = 0–4%). For color match, glass ionomer restorations showed significantly poorer outcomes (RD = –0.23; 95% CI, –0.31 to –0.14; p < 0.00001; I2 = 98%), while conventional resin composites had a slight but significant advantage over bioactive composites (RD = 0.07; 95% CI, 0.02 to 0.12; p = 0.003; I2 = 76%). Most studies presented moderate risk of bias and short-term follow-up (<36 months). Conclusions: Current evidence indicates that bioactive composites perform comparably, but not superior, to conventional restoratives in permanent teeth. The discrepancy between laboratory bioactivity and clinical effectiveness highlights the need for long-term, well-designed clinical trials with standardized outcome reporting.
- Open Access
- 6 January 2026
- Published by MDPI AG in Journal of Composites Science
- Vol. 10 (1) , 26
Microbial Adhesion on 3D-Printed Composite Polymers Used for Orthodontic Clear Aligners: A Systematic Review and Meta-Analysis of In Vitro Evidence
Objectives: This systematic review and meta-analysis aimed to evaluate microbial adhesion and biofilm formation on additively manufactured composite-based orthodontic clear aligners compared with thermoformed aligners and other conventional polymeric materials. The influence of material composition, surface roughness, post-processing parameters, and cleaning protocols on microbial colonization was also assessed. Methods: A comprehensive search of PubMed, EMBASE, Scopus, Web of Science, and the Cochrane Library was conducted up to September 2025. Only in vitro studies investigating microbial adhesion, biofilm biomass, or microbiome changes on three-dimensional (3D)-printed aligner composites were included. Primary outcomes consisted of colony-forming units (CFU), optical density (OD) from crystal violet assays, viable microbial counts, and surface roughness. Risk of bias was assessed using the RoBDEMAT tool. Data were narratively synthesized, and a random-effects meta-analysis was performed for comparable datasets. Results: Five studies fulfilled the inclusion criteria, of which two in vitro studies were eligible for meta-analysis. Microbial adhesion and biofilm accumulation were influenced by the manufacturing technique, composite resin formulation, and surface characteristics. Certain additively manufactured aligners exhibited smoother surfaces and reduced bacterial adhesion compared with thermoformed controls, whereas others with increased surface roughness showed higher biofilm accumulation. Incorporating bioactive additives such as chitosan nanoparticles reduced Streptococcus mutans biofilm formation without compromising material properties. The meta-analysis, based on two in vitro studies, demonstrated higher OD values for bacterial biofilm on 3D-printed aligners compared with thermoformed aligners, indicating increased biofilm biomass (p < 0.05), but not necessarily viable bacterial load. Conclusions: Microbial adhesion and biofilm formation on 3D-printed composite clear aligners are governed by resin composition, additive manufacturing parameters, post-curing processes, and surface finishing. Although certain 3D-printed materials display antibacterial potential, the limited number of studies restricts the generalizability of these findings. Clinical Significance: Optimizing composite formulations for 3D printing, alongside careful post-curing and surface finishing, may help reduce microbial colonization. Further research is required before translating these findings into definitive clinical recommendations for clear aligner therapy.
- 6 January 2026
- Published by MDPI AG in Journal of Composites Science
- Vol. 10 (1) , 26
Open AccessMicrobial Adhesion on 3D-Printed Composite Polymers Used for Orthodontic Clear Aligners: A Systematic Review and Meta-Analysis of In Vitro Evidence
Objectives: This systematic review and meta-analysis aimed to evaluate microbial adhesion and biofilm formation on additively manufactured composite-based orthodontic clear aligners compared with thermoformed aligners and other conventional polymeric materials. The influence of material composition, surface roughness, post-processing parameters, and cleaning protocols on microbial colonization was also assessed. Methods: A comprehensive search of PubMed, EMBASE, Scopus, Web of Science, and the Cochrane Library was conducted up to September 2025. Only in vitro studies investigating microbial adhesion, biofilm biomass, or microbiome changes on three-dimensional (3D)-printed aligner composites were included. Primary outcomes consisted of colony-forming units (CFU), optical density (OD) from crystal violet assays, viable microbial counts, and surface roughness. Risk of bias was assessed using the RoBDEMAT tool. Data were narratively synthesized, and a random-effects meta-analysis was performed for comparable datasets. Results: Five studies fulfilled the inclusion criteria, of which two in vitro studies were eligible for meta-analysis. Microbial adhesion and biofilm accumulation were influenced by the manufacturing technique, composite resin formulation, and surface characteristics. Certain additively manufactured aligners exhibited smoother surfaces and reduced bacterial adhesion compared with thermoformed controls, whereas others with increased surface roughness showed higher biofilm accumulation. Incorporating bioactive additives such as chitosan nanoparticles reduced Streptococcus mutans biofilm formation without compromising material properties. The meta-analysis, based on two in vitro studies, demonstrated higher OD values for bacterial biofilm on 3D-printed aligners compared with thermoformed aligners, indicating increased biofilm biomass (p < 0.05), but not necessarily viable bacterial load. Conclusions: Microbial adhesion and biofilm formation on 3D-printed composite clear aligners are governed by resin composition, additive manufacturing parameters, post-curing processes, and surface finishing. Although certain 3D-printed materials display antibacterial potential, the limited number of studies restricts the generalizability of these findings. Clinical Significance: Optimizing composite formulations for 3D printing, alongside careful post-curing and surface finishing, may help reduce microbial colonization. Further research is required before translating these findings into definitive clinical recommendations for clear aligner therapy.